Open Access. Powered by Scholars. Published by Universities.®
Articles 1 - 13 of 13
Full-Text Articles in Other Engineering
Fire Protection Analysis Of A K-12 Classroom Building, Raymond Yip
Fire Protection Analysis Of A K-12 Classroom Building, Raymond Yip
Fire Protection Engineering: Culminating Experience Project Reports
The report evaluates the fire protection features of a K-12 classroom building (Bldg. B) in San Bernardino County, California. Bldg. B is a two-story Type V-A light timber frame construction. At the time of this report’s composition, Bldg. B is undergoing modernization construction. The fire protection analysis of this building consists of prescriptive and performance portions.
The prescriptive analysis verifies the compliance of building egress, passive, and active protection features with the 2019 edition of California Codes of Regulations Title 24 (Title 24) and Title 24-adopted National Fire Protection Association (NFPA) standards. The analysis comprises of four sections: egress, structural …
Fire And Life Safety Evaluation Of An Assisted Living And Memory Care Center, Sarah Chandonait
Fire And Life Safety Evaluation Of An Assisted Living And Memory Care Center, Sarah Chandonait
Fire Protection Engineering: Culminating Experience Project Reports
This culminating project has been submitted as part of the graduate program in Fire Protection Engineering at Cal Poly. It documents an Assisted Living and Memory Care Center’s compliance with applicable fire safety prescriptions contained in the 2019 California Building and Fire Codes (CBC and CFC). Performance-based methods incorporating deterministic design fires were then used to verify that the final building design and operating procedures met the life safety needs of its unique occupants.
The building under analysis was a 45,000 sq. ft, two-story, 58-bed residential care facility for the elderly. Occupants were all 60 years or older without acute …
Fire Protection And Life Safety Analysis Of The Adult Education Facility, William K.W. Bridges
Fire Protection And Life Safety Analysis Of The Adult Education Facility, William K.W. Bridges
Fire Protection Engineering: Culminating Experience Project Reports
The objective of this report is to provide an analysis of an existing building’s prescriptive-based and performance-based design methods. The intention is to provide the building owner with a working assessment of the building’s current life safety situation, as well as providing recommendations to improve the overall life safety and property protection of the selected building. This report is developed following the writing style and structure to meet the requirement for the Master of Science Degree in Fire Protection Engineering from California Polytechnic State University. The analysis includes an evaluation of the building owner’s fire and safety program for the …
Warren Baker Center For Science And Mathematics- Fire Protection And Life Safety Analysis, Logan Honeycutt
Warren Baker Center For Science And Mathematics- Fire Protection And Life Safety Analysis, Logan Honeycutt
Fire Protection Engineering: Culminating Experience Project Reports
This report covers an analysis of the fire protection features within the Warren Baker Center for Science and Mathematics Building. This document first discusses the prescriptive requirements for the building as determined by applicable code. The items to be discussed, as they relate to prescriptive requirements, include the means of egress and relatable components, fire resistive construction, fire alarm system, fire sprinkler system, and smoke control system. All components were analyzed and compared to each applicable code to assess whether these specific fire protection systems were designed correctly.
In addition to an analysis of the prescriptive measures in this facility, …
Fire Protection Analysis Project – 9220 Zanzibar Lane Maple Grove, Mn, Brian Vandal
Fire Protection Analysis Project – 9220 Zanzibar Lane Maple Grove, Mn, Brian Vandal
Fire Protection Engineering: Culminating Experience Project Reports
This report contains an analysis of the life safety and fire protection features of a four-story apartment building in Maple Grove, Minnesota. The report is a part of the final project intended to meet the requirements for the Culminating Experience of the California Polytechnic Master of Science Fire Protection Engineering Program.
The apartment building chosen for the analysis is a mixed-use four-story wood-framed structure. The first floor of this structure includes office space for building management, a meeting space, and various electrical and mechanical spaces as well as apartments. There are exit stairways on each end of the structure extending …
Bonderson Engineering Center, Hannah Curry
Bonderson Engineering Center, Hannah Curry
Fire Protection Engineering: Culminating Experience Project Reports
As part of the requirements for receiving a Master of Science in Fire Protection Engineering from California Polytechnic State University at San Luis Obispo, a Fire and Life Safety Analysis of the Bonderson Engineering Projects Center located on the Cal Poly San Luis Obispo campus is performed. The analysis consists of both a prescriptive and a performance-based analysis.
The prescriptive analysis focuses on reviewing the as-built conditions within the Bonderson Engineering Projects Center for compliance with the current edition of applicable codes and standards. The analysis is performed using the 2018 Edition of the International Building Code (IBC) and the …
Fire Protection And Life Safety Analysis: Canyon Vista Dining Renovation- University Of California San Diego, Paul Ian Jungco Cabasag
Fire Protection And Life Safety Analysis: Canyon Vista Dining Renovation- University Of California San Diego, Paul Ian Jungco Cabasag
Fire Protection Engineering: Culminating Experience Project Reports
The Canyon Vista Dining project is a renovation of an existing two-story dining facility located in the Warren College area of the University of California San Diego campus for the owners, Housing, Dining and Hospitality. The renovation scope of work comprised a new dining experience with a better diversity of food options and indoor and outdoor seating, which upgraded the first floor, second floor, and mechanical penthouse. In the course of the design and construction, the prescriptive, performance, wildfire, and due diligence design results were utilized during discussions with design team and building permit approval. The project construction was completed …
Fire Protection Analysis Of Johnson Controls Office Building, Derek Driscoll
Fire Protection Analysis Of Johnson Controls Office Building, Derek Driscoll
Fire Protection Engineering: Culminating Experience Project Reports
This project report contains a fire and life safety analysis of the Johnson Controls Office Building. The building is located in Los Angeles, California. The building is a mixed use occupancy with office spaces, meeting rooms, training rooms, and a warehouse for storing fire sprinkler and fire alarm materials. The building is one level with a mezzanine. It is attached to another building and separated by fire barrier so that they are considered separate buildings. This report contains a prescriptive analysis and a performance-based design analysis of the building.
The prescriptive code requirements were determined based on the 2019 edition …
Fire Protection And Life Safety Analysis Of A Chicago Hotel, Thomas Hampton
Fire Protection And Life Safety Analysis Of A Chicago Hotel, Thomas Hampton
Fire Protection Engineering: Culminating Experience Project Reports
The following report contains an analysis of the life safety and fire protection features of a Chicago Hotel. The report is intended to meet the requirements for the Culminating Experience of the Cal Poly Master of Science Fire Protection Engineering Program.
The Chicago Hotel building chosen for the analysis is a mixed-use 7-story hotel. On the 1st, 2nd, and 7th floors of the building are spaces for mercantile and restaurant tenants as well as other spaces necessary for the operation of the building such as back of house space for the hotel, storage, employee locker rooms, hotel and retail lobbies, …
Cal Poly Engineering Iv Building, Kai Liu
Cal Poly Engineering Iv Building, Kai Liu
Fire Protection Engineering: Culminating Experience Project Reports
This report analyzes the fire protection systems of Engineering IV building at California Polytechnic State University, San Luis Obispo. It is a cumulative project of the Fire Protection Engineering Program at Cal Poly. The report consists of a prescriptive analysis and a performance-based design analysis. The building contains dry laboratories, classrooms, offices, and administrative spaces. The building is a three-story structure. There is an atrium that connects the first floor to the third floor. However, the building has a horizontal enclosure to separate the connection between the second floor and the third floor.
The prescriptive analysis is based on the …
Office High Rise Building- Fire Protection And Life Safety Analysis, Fabio Renato Zocal Mazza
Office High Rise Building- Fire Protection And Life Safety Analysis, Fabio Renato Zocal Mazza
Fire Protection Engineering: Culminating Experience Project Reports
This project developed the traditional prescriptive-based design analysis of the fire protection features of an existing office high rise building in the city of Sao Paulo, in Brazil. The analysis was then complemented by performance-based analysis of the building. The building is a high rise office located in a metropolitan area, provided also with underground car parking garages and a small theater. The fire protection analysis was conducted based on the local Sao Paulo state fire codes, mainly the Sao Paulo State enactment (Decreto Nº56.819/2011) and Sao Paulo Fire Department Technical Instructions; and, in addition to the local codes, the …
Fire And Life Safety Evaluation & Analysis- Bonderson Engineering Projects Center, Garrett Brown
Fire And Life Safety Evaluation & Analysis- Bonderson Engineering Projects Center, Garrett Brown
Fire Protection Engineering: Culminating Experience Project Reports
A Fire and Life Safety Analysis of the Bonderson Engineering Projects Center, (BEPC) Building 197 on the California Polytechnic State University, San Luis Obispo (Cal Poly) Campus is performed. Both prescriptive and performance based methods and metrics are utilized to evaluate the facility with respect to current fire and building standards and codes. Prescriptive fire protection features and systems analyzed include: building construction type and design, structural fire protection features and requirements, occupancy classification and egress analysis, fire detection, alarm, and communication systems, and fire suppression systems The prescriptive based design requirements largely met the code and installation requirements with …
Fire Protection Analysis Of The Bonderson Engineering Projects Center, John Cote
Fire Protection Analysis Of The Bonderson Engineering Projects Center, John Cote
Fire Protection Engineering: Culminating Experience Project Reports
A Fire and Life Safety Analysis of the Bonderson Engineering Projects Center (BEPC) located on the Cal Poly campus is performed. Prescriptive and Performance Based approaches are used to evaluate the BEPC for compliance with the current fire and building code requirements. The fire protection systems and features of the BEPC analyzed include the following: Egress Systems, Fire Detection, Alarm, and Communications Systems, Fire Suppression Systems, and Structural Fire Protection Systems. Prescriptive analyses are performed to determine if the as-built design meets the requirements of the code. Performance-Based analyses are performed to provide insight to the prescriptive design utilized in …