Fire Protection And Life Safety Analysis Of The Illinois Department Of Transportation (Idot) District Six Headquarters Building, Karl Mallinger Jun 2023

Fire Protection And Life Safety Analysis Of The Illinois Department Of Transportation (Idot) District Six Headquarters Building, Karl Mallinger

Fire Protection Engineering: Culminating Experience Project Reports

Enclosed in this report is a comprehensive analysis of the fire protection and life safety components of the Illinois Department of Transportation (IDOT) District Six Headquarters building. The original building was constructed in 1972 and renovation operations were recently completed in 2022. The building is four stories in height with an aggregate floor area of approximately 69,300 square feet. The building functions as an office space for IDOT staff, therefore the majority of floor space is used as open office and private office space. The business spaces are supported by assembly spaces such as conference and break rooms on each …


Fire Protection And Life Safety Analysis Of The 2704-Hv Hanford Building, Guillermo Rodriguez Jun 2023

Fire Protection And Life Safety Analysis Of The 2704-Hv Hanford Building, Guillermo Rodriguez

Fire Protection Engineering: Culminating Experience Project Reports

This report analyzes multiple aspects of fire protection and life safety design for the 2704-HV Building located at the Hanford Nuclear Reservation Site in Washington State. The analysis contained within focuses on both prescriptive and performance-based designs for the fire systems within the structure. The 2704-HV building is a two-story office building containing approximately 90 individual full-office spaces on each floor along with approximately 60 individual cubicle office spaces on each floor. There are various other types of gathering spaces within the 2704-HV layout including: conference rooms, showers, kitchen and dining areas, training rooms, and lobbies.

The 2704-HV building was …


Fire Protection And Life Safety Analysis Of A University Conference Center, Amanda Beck Larkin Jun 2022

Fire Protection And Life Safety Analysis Of A University Conference Center, Amanda Beck Larkin

Fire Protection Engineering: Culminating Experience Project Reports

This project report analyzes various aspects of fire protection and life safety design for a University Conference Center, for both prescriptive and performance-based designs. The University Conference Center is a ten-story, high-rise building comprised of various gathering spaces, ranging from small conference rooms to large assembly spaces with auditorium-style seating. The building has a large two-story podium with basement below, with a smaller floor plate, ten-story tower offset to one side.

In the prescriptive analysis, no deficiencies were noted in the water-based suppression or fire resistance analysis. The building construction type, height, area, number of stories, wall and structural ratings, …


Second Baptist Church, Cypress Campus, David Kalinec Jun 2020

Second Baptist Church, Cypress Campus, David Kalinec

Fire Protection Engineering: Culminating Experience Project Reports

This report was created as part of the Master of Science Fire Protection Engineering degree program at California Polytechnic State University at San Luis Obispo. This project summarized the covered subjects during the course of each quarter of the program. The site chosen for this project is Second Baptist Church, Cypress Campus, located in Cypress, TX. This building was chosen because Churches are mixed use buildings that include assembly occupancies and large occupant loads.

A prescriptive-based code evaluation was performed on the building according to the 2012 editions of the international building code and fire code, adopted at the time …


Orfalea College Of Business Fire Safety Analysis, Garth Ornelas Mar 2017

Orfalea College Of Business Fire Safety Analysis, Garth Ornelas

Fire Protection Engineering: Culminating Experience Project Reports

The following report discusses the fire and life safety factors for the Orfalea College of Business Building located on the main campus of California Polytechnic State University in San Luis Obispo. The building functions are primarily administrative and academic in nature, with various lecture halls, offices, and labs located throughout the building. The Business Building was constructed in 1989 following the 1985 Uniform Building Code (UBC). For the purposes of this report, the building will be evaluated using the 2015 International Building Code, NFPA Life Safety Code Handbook (Thirteenth Edition), SFPE Handbook (4th and 5th Editions), and the NFPA handbooks …


Building X- Fire Protection System And Life Safety Evaluation, Anthony W. Sublett Jun 2016

Building X- Fire Protection System And Life Safety Evaluation, Anthony W. Sublett

Fire Protection Engineering: Culminating Experience Project Reports

The fire protection and life safety systems for Building X were evaluated for compliance in accordance with applicable nuclear power plant non-power block regulatory requirements, NEIL, INPO, IBC, and NFPA design requirements, codes, and standards. Building X is a one-story building with two internal balconies with 10 occupants per balcony, which is made of non-combustible materials that also has a partial basement with concrete walls (is normally unoccupied), which houses potable water pumps and piping for the facility. Building X falls under the definition of mixed occupancy per the International Building Code (IBC) and the Life Safety Code (LSC). Since …


Westside Christian High School, Michael Stewart Jun 2014

Westside Christian High School, Michael Stewart

Fire Protection Engineering: Culminating Experience Project Reports

The building I have chosen to use as the model for exemplifying the components of a wet fire suppression system is Westside Christian High School (WCHS). This building completed construction in January of 2014 and is located at: 8200 SW Pfaffle Street Tigard, Oregon 97223. The existing structure was previously owned and occupied by City Bible Church who will now lease space from the High school during and after construction. The renovations include the addition of space for music, art classes, fitness center, gym, science labs, and others. The renovations will also be widening existing rooms and hallways. The core …