Open Access. Powered by Scholars. Published by Universities.®

Other Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Fire Protection Engineering: Culminating Experience Project Reports

Life Safety

Articles 1 - 21 of 21

Full-Text Articles in Other Engineering

Fire Protection Engineering For Building A, Ai Choong Loh Jun 2023

Fire Protection Engineering For Building A, Ai Choong Loh

Fire Protection Engineering: Culminating Experience Project Reports

Building A is a 9-storey mixed used development in Singapore to be completed in 2028. Fire safety provisions of Building A shall be in accordance with Singapore Fire Code 2018.

The report has analyzed the fire safety provisions in the area of structural fire protection provision, means of escape provision, automatic water suppression system provision, automatic fire detection and alarm system provision, engineering smoke control system provision, flammability assessment as well as performance based assessment.

Generally, building A complied to the prescriptive requirements of automatic water suppression system provision, automatic fire detection and alarm system, structural fire provision and means …


Fire Protection And Life Safety Analysis Of The Illinois Department Of Transportation (Idot) District Six Headquarters Building, Karl Mallinger Jun 2023

Fire Protection And Life Safety Analysis Of The Illinois Department Of Transportation (Idot) District Six Headquarters Building, Karl Mallinger

Fire Protection Engineering: Culminating Experience Project Reports

Enclosed in this report is a comprehensive analysis of the fire protection and life safety components of the Illinois Department of Transportation (IDOT) District Six Headquarters building. The original building was constructed in 1972 and renovation operations were recently completed in 2022. The building is four stories in height with an aggregate floor area of approximately 69,300 square feet. The building functions as an office space for IDOT staff, therefore the majority of floor space is used as open office and private office space. The business spaces are supported by assembly spaces such as conference and break rooms on each …


Fire And Life Safety Evaluation Of An Assisted Living And Memory Care Center, Sarah Chandonait Jun 2023

Fire And Life Safety Evaluation Of An Assisted Living And Memory Care Center, Sarah Chandonait

Fire Protection Engineering: Culminating Experience Project Reports

This culminating project has been submitted as part of the graduate program in Fire Protection Engineering at Cal Poly. It documents an Assisted Living and Memory Care Center’s compliance with applicable fire safety prescriptions contained in the 2019 California Building and Fire Codes (CBC and CFC). Performance-based methods incorporating deterministic design fires were then used to verify that the final building design and operating procedures met the life safety needs of its unique occupants.

The building under analysis was a 45,000 sq. ft, two-story, 58-bed residential care facility for the elderly. Occupants were all 60 years or older without acute …


Analysis Of Scramento State University Union, Zachary Schuler Jun 2023

Analysis Of Scramento State University Union, Zachary Schuler

Fire Protection Engineering: Culminating Experience Project Reports

Sacramento State Union is a centrally located building with a large occupant load during the school year. This building is a 239,000-square-foot three-story structure built originally back in 1975. This original building was constructed using waffle slab construction. Additions in 1996 and 2016 were built using steel beam and girder construction to meet the total square footage we have today. This mixed-use occupancy is not only a congregation point, but many events are held in this building as well.

In this analysis of the building, fire life safety systems are reviewed and determined if they not only meet the minimum …


Grange Insurance Audubon Center-Fire Protection Life Safety Report, Gabriel Levy Jun 2022

Grange Insurance Audubon Center-Fire Protection Life Safety Report, Gabriel Levy

Fire Protection Engineering: Culminating Experience Project Reports

This technical approach narrative presents the intent and methodology of the Fire Protection and Life Safety systems for the Grange Insurance Audubon Center located at 505 W Whittier St. Columbus OH 43215. The primary goal of the structure is to provide life and property protection in a fire scenario while taking into account the costs of implementing the criterion and risks associated with the facility. This will be achieved through the appropriate application of requirements listed in the 2015 International Building Code (IBC) and the International Fire Code (IFC) as adopted by the City of Columbus, Ohio, and any reference …


Fire Protection And Life Safety Analysis Of The Adult Education Facility, William K.W. Bridges Jun 2022

Fire Protection And Life Safety Analysis Of The Adult Education Facility, William K.W. Bridges

Fire Protection Engineering: Culminating Experience Project Reports

The objective of this report is to provide an analysis of an existing building’s prescriptive-based and performance-based design methods. The intention is to provide the building owner with a working assessment of the building’s current life safety situation, as well as providing recommendations to improve the overall life safety and property protection of the selected building. This report is developed following the writing style and structure to meet the requirement for the Master of Science Degree in Fire Protection Engineering from California Polytechnic State University. The analysis includes an evaluation of the building owner’s fire and safety program for the …


Fire Protection And Life Safety Analysis Of A University Conference Center, Amanda Beck Larkin Jun 2022

Fire Protection And Life Safety Analysis Of A University Conference Center, Amanda Beck Larkin

Fire Protection Engineering: Culminating Experience Project Reports

This project report analyzes various aspects of fire protection and life safety design for a University Conference Center, for both prescriptive and performance-based designs. The University Conference Center is a ten-story, high-rise building comprised of various gathering spaces, ranging from small conference rooms to large assembly spaces with auditorium-style seating. The building has a large two-story podium with basement below, with a smaller floor plate, ten-story tower offset to one side.

In the prescriptive analysis, no deficiencies were noted in the water-based suppression or fire resistance analysis. The building construction type, height, area, number of stories, wall and structural ratings, …


Bonderson Engineering Center, Hannah Curry Sep 2021

Bonderson Engineering Center, Hannah Curry

Fire Protection Engineering: Culminating Experience Project Reports

As part of the requirements for receiving a Master of Science in Fire Protection Engineering from California Polytechnic State University at San Luis Obispo, a Fire and Life Safety Analysis of the Bonderson Engineering Projects Center located on the Cal Poly San Luis Obispo campus is performed. The analysis consists of both a prescriptive and a performance-based analysis.

The prescriptive analysis focuses on reviewing the as-built conditions within the Bonderson Engineering Projects Center for compliance with the current edition of applicable codes and standards. The analysis is performed using the 2018 Edition of the International Building Code (IBC) and the …


Fire Protection And Life Safety Analysis: Canyon Vista Dining Renovation- University Of California San Diego, Paul Ian Jungco Cabasag Jun 2021

Fire Protection And Life Safety Analysis: Canyon Vista Dining Renovation- University Of California San Diego, Paul Ian Jungco Cabasag

Fire Protection Engineering: Culminating Experience Project Reports

The Canyon Vista Dining project is a renovation of an existing two-story dining facility located in the Warren College area of the University of California San Diego campus for the owners, Housing, Dining and Hospitality. The renovation scope of work comprised a new dining experience with a better diversity of food options and indoor and outdoor seating, which upgraded the first floor, second floor, and mechanical penthouse. In the course of the design and construction, the prescriptive, performance, wildfire, and due diligence design results were utilized during discussions with design team and building permit approval. The project construction was completed …


The Spheres, Justin Milne Jun 2019

The Spheres, Justin Milne

Fire Protection Engineering: Culminating Experience Project Reports

The Spheres, an architectural masterpiece surrounded by a high-rise building complex, is in the heart of South Lake Union in Seattle, Washington. The Spheres building pushes limitations in building design on all levels. With hexecontahedron panels tessellated over the façade of its three spherical glass glaze greenhouse globes, the design affords futuristic personality, alongside energy efficacy while sustaining life within the building. While building innovations within The Spheres are certainly notable within all disciplines of Architecture, Engineering, and Construction, the contents of this report refer to fire protection engineering and code consulting elements.

In meeting The Spheres' required fire safety …


University Student Services Center, Ivan Orlando Mendoza Jun 2018

University Student Services Center, Ivan Orlando Mendoza

Fire Protection Engineering: Culminating Experience Project Reports

The building was found to be generally compliant with the requirements set forth in the codes and standards, any discrepancies are addressed within the report in their respective sections. The prescriptive-based analysis was performed using the appropriate NFPA standards, the Life Safety Code (LSC) and the International Building Code (IBC).

The building is three storied and has an overall gross floor area of 101,579 sq ft. It is classified as a mixed occupancy use with a calculated total occupant load of 2,866 occupants and is being evaluated as a Type II-B structure as defined in the IBC. It is protected …


Monticello Office Building- Fire And Life Safety Analysis, Mark James Masciarelli Jun 2016

Monticello Office Building- Fire And Life Safety Analysis, Mark James Masciarelli

Fire Protection Engineering: Culminating Experience Project Reports

A Fire and Life Safety analysis was performed on the existing Monticello Office Building located in Delaware, USA. The Monticello Office Building is a mixed use building that contains office space to support a population of 700 people, dining facilities to accommodate approximately 400 people, and a conference area for up to 125 people. The building is composed of two major components; a five (5) story office wing and a one (1) and two (2) story amenities wing that mainly houses the food service, dining, kitchen, retail and conference areas. A prescriptive analysis of this building was performed to determine …


Centennial Station- Evaluation, Brandon Huffman Jun 2016

Centennial Station- Evaluation, Brandon Huffman

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of this analysis is for completion of FPE 596 Culminating Experience in Fire Protection Engineering course in the Fire Protection Engineering Program at California Polytechnic State University. This analysis has been compiled using previous design courses evaluating the egress analysis, suppression design, alarm and detection design, smoke control system design, and structural fire protection. The context of the courses studied both prescriptive and performance based design approaches.

The building chosen for the analysis is Centennial Station located approximately 15 miles south of Denver, Colorado at 12154 East Easter Avenue, Englewood, CO 80112. The facility was designed specifically for …


Technical Area 3 - 40; Physics Building- Fire And Life Safety Analysis, Parker Fellows Mar 2016

Technical Area 3 - 40; Physics Building- Fire And Life Safety Analysis, Parker Fellows

Fire Protection Engineering: Culminating Experience Project Reports

A Fire Protection Engineering Analysis was performed on TA‐3‐0040, Physics Building at the Los Alamos National Laboratory in Los Alamos, New Mexico. The goal of the analysis has two parts; first, to examine the buildings fire protection features from a code based prescriptive analysis and second, to examine the building and fire protection features using a performance based design analysis.

Building 40 is a 2 story structure approximately 187,000 square feet. The building was constructed in the mid‐1950s with a first floor, basement, partial sub‐basement, and various mezzanines. Originally, this building was constructed as a non‐combustible type IIB structure according …


Fire And Life Safety Evaluation & Analysis- Bonderson Engineering Projects Center, Garrett Brown Mar 2015

Fire And Life Safety Evaluation & Analysis- Bonderson Engineering Projects Center, Garrett Brown

Fire Protection Engineering: Culminating Experience Project Reports

A Fire and Life Safety Analysis of the Bonderson Engineering Projects Center, (BEPC) Building 197 on the California Polytechnic State University, San Luis Obispo (Cal Poly) Campus is performed. Both prescriptive and performance based methods and metrics are utilized to evaluate the facility with respect to current fire and building standards and codes. Prescriptive fire protection features and systems analyzed include: building construction type and design, structural fire protection features and requirements, occupancy classification and egress analysis, fire detection, alarm, and communication systems, and fire suppression systems The prescriptive based design requirements largely met the code and installation requirements with …


Laboratory Building- Sandia National Laboratories, Albuquerque, Nm, Joshua Herrera Mar 2015

Laboratory Building- Sandia National Laboratories, Albuquerque, Nm, Joshua Herrera

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of the culminating report was to perform a prescriptive-based and performance-based analysis on the fire and life safety systems in the laboratory building at Sandia National Laboratories (SNL). The prescriptive-based analysis determined if the laboratory building met applicable code requirements for life safety systems. The performance-based analysis conducted a series of fire scenarios to ensure the fire and life safety systems provided adequate egress time for occupants in the event of a fire. The prescriptive-based analysis was based on the Life Safety Code (LSC) and International Building Code (IBC). The laboratory building is a mixed occupancy building. The …


Fire And Life Safety Analysis Of The Bonderson Engineering Projects Center, Brian Sackett Jun 2014

Fire And Life Safety Analysis Of The Bonderson Engineering Projects Center, Brian Sackett

Fire Protection Engineering: Culminating Experience Project Reports

As part of the requirements for the Degree of Masters of Science in Fire Protection Engineering from California Polytechnic State University, San Luis Obispo, a prescriptive and performance based design analysis was conducted for the Bonderson Engineering Projects Center building (Cal Poly campus). The purpose of this analysis was to review the Bonderson Engineering Projects Center’s compliance with applicable and recognized fire and building codes with regards to its fire protection systems and features. The fire protection systems and features analyzed in this report include: 1) Egress Systems, 2) Structural Fire Protection, 3) Fire Detection and Alarm Systems, 4) Fire …


Fire And Life Safety Report- Agricultural Sciences Building- Cal Poly, Jonathan Schram Jun 2014

Fire And Life Safety Report- Agricultural Sciences Building- Cal Poly, Jonathan Schram

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of this fire and life safety analysis is to provide a conclusion on whether the Agricultural Sciences Building (ASB) meets fire safety goals. The primary fire safety goal is to provide building occupants a safe environment during fire conditions. This goal can be achieved by protecting the occupants not intimate with the initial fire development and improving survivability of those occupants intimate with the initial fire development. A prescriptive-based design approach and a performance-based design approach are used to evaluate building safety. The prescriptive-based approach is used to evaluate the building's structural fire protection systems, fire detection and …


Fire Protection Analysis Of Campus Building, Mackenzie Hill Jun 2013

Fire Protection Analysis Of Campus Building, Mackenzie Hill

Fire Protection Engineering: Culminating Experience Project Reports

A prescriptive and performance based analysis has been conducted on a College Campus Building in Southern California. This building is still in the approvals process and has been designed to meet the design standards in the 2010 California Building Code (CBC) and relevant NFPA codes. The building is proposed to be the center of operations as well as having administration facilities for the College. It will house an administrative office, production and support facilities. The project is three stories and includes a balcony that does not qualify as a story. The top floor is greater than 30 feet from grade …


Fire Protection Analysis Of The Bonderson Engineering Projects Center, John Cote Jun 2013

Fire Protection Analysis Of The Bonderson Engineering Projects Center, John Cote

Fire Protection Engineering: Culminating Experience Project Reports

A Fire and Life Safety Analysis of the Bonderson Engineering Projects Center (BEPC) located on the Cal Poly campus is performed. Prescriptive and Performance Based approaches are used to evaluate the BEPC for compliance with the current fire and building code requirements. The fire protection systems and features of the BEPC analyzed include the following: Egress Systems, Fire Detection, Alarm, and Communications Systems, Fire Suppression Systems, and Structural Fire Protection Systems. Prescriptive analyses are performed to determine if the as-built design meets the requirements of the code. Performance-Based analyses are performed to provide insight to the prescriptive design utilized in …


Fire Protection Analysis Of A Fresno Elementary School, Garen Lencioni Jun 2013

Fire Protection Analysis Of A Fresno Elementary School, Garen Lencioni

Fire Protection Engineering: Culminating Experience Project Reports

This report details the fire and life safety analysis of a Fresno Elementary School. Both prescriptive and performance based analysis were used to determine compliance with the building codes and fire codes which the building was constructed under. The prescriptive analyses included evaluation of the egress system, structural fire protection requirements, fire detection and alarm system and fire suppression systems. The prescriptive analyses were done to show the code requirements and how the building complies with them. The performance analyses were done to analyze the performance of the building in the event of a fire scenario. Three fire scenarios were …