Fire Protection Engineering: Culminating Experience Project Reports

Egress

Articles 1 - 16 of 16

Full-Text Articles in Other Engineering

Office Building In Moffett Park District, Cody Williams Jun 2023

Office Building In Moffett Park District, Cody Williams

Fire Protection Engineering: Culminating Experience Project Reports

The objective of this review is to analyze and evaluate the fire safety of a 5-story office building located in the Moffett Park District in Sunnyvale, California. The building is constructed largely of mass timber and classified as a Type IIIA building used primarily as office space. The first section of the report focuses on the building’s defining characteristics and use cases. The second portion of the report presents a comprehensive review of egress design, fire alarm systems, fire suppression systems, structural design, implementation of mass timber elements, and flammability requirements. The results of the analysis show that the building …


Fire Protection And Life Safety Analysis Of The Illinois Department Of Transportation (Idot) District Six Headquarters Building, Karl Mallinger Jun 2023

Fire Protection And Life Safety Analysis Of The Illinois Department Of Transportation (Idot) District Six Headquarters Building, Karl Mallinger

Fire Protection Engineering: Culminating Experience Project Reports

Enclosed in this report is a comprehensive analysis of the fire protection and life safety components of the Illinois Department of Transportation (IDOT) District Six Headquarters building. The original building was constructed in 1972 and renovation operations were recently completed in 2022. The building is four stories in height with an aggregate floor area of approximately 69,300 square feet. The building functions as an office space for IDOT staff, therefore the majority of floor space is used as open office and private office space. The business spaces are supported by assembly spaces such as conference and break rooms on each …


Analysis Of Scramento State University Union, Zachary Schuler Jun 2023

Analysis Of Scramento State University Union, Zachary Schuler

Fire Protection Engineering: Culminating Experience Project Reports

Sacramento State Union is a centrally located building with a large occupant load during the school year. This building is a 239,000-square-foot three-story structure built originally back in 1975. This original building was constructed using waffle slab construction. Additions in 1996 and 2016 were built using steel beam and girder construction to meet the total square footage we have today. This mixed-use occupancy is not only a congregation point, but many events are held in this building as well.

In this analysis of the building, fire life safety systems are reviewed and determined if they not only meet the minimum …


Building San Francisco, Ca, Kevin Nguyen Jun 2023

Building San Francisco, Ca, Kevin Nguyen

Fire Protection Engineering: Culminating Experience Project Reports

The objective of this report is to conduct a thorough analysis and evaluation of the existing fire life safety and fire protection systems in place at the Building located in San Francisco, California. The building is classified as a Type II-A building and serves predominantly as office space. The building is six stories tall with a total gross area of approximately 97,170 SF.

The initial portion of this report concentrates on a thorough prescriptive-based analysis, which provides an evaluation of the egress design, fire alarm system, communication systems, fire suppression system, structural and construction design, smoke control, and flammability requirements. …


Fire Protection And Life Safety Analysis Of The 2704-Hv Hanford Building, Guillermo Rodriguez Jun 2023

Fire Protection And Life Safety Analysis Of The 2704-Hv Hanford Building, Guillermo Rodriguez

Fire Protection Engineering: Culminating Experience Project Reports

This report analyzes multiple aspects of fire protection and life safety design for the 2704-HV Building located at the Hanford Nuclear Reservation Site in Washington State. The analysis contained within focuses on both prescriptive and performance-based designs for the fire systems within the structure. The 2704-HV building is a two-story office building containing approximately 90 individual full-office spaces on each floor along with approximately 60 individual cubicle office spaces on each floor. There are various other types of gathering spaces within the 2704-HV layout including: conference rooms, showers, kitchen and dining areas, training rooms, and lobbies.

The 2704-HV building was …


Fire Protection And Life Safety Analysis Of A University Conference Center, Amanda Beck Larkin Jun 2022

Fire Protection And Life Safety Analysis Of A University Conference Center, Amanda Beck Larkin

Fire Protection Engineering: Culminating Experience Project Reports

This project report analyzes various aspects of fire protection and life safety design for a University Conference Center, for both prescriptive and performance-based designs. The University Conference Center is a ten-story, high-rise building comprised of various gathering spaces, ranging from small conference rooms to large assembly spaces with auditorium-style seating. The building has a large two-story podium with basement below, with a smaller floor plate, ten-story tower offset to one side.

In the prescriptive analysis, no deficiencies were noted in the water-based suppression or fire resistance analysis. The building construction type, height, area, number of stories, wall and structural ratings, …


Fire Protection Analysis Project – 9220 Zanzibar Lane Maple Grove, Mn, Brian Vandal Jun 2022

Fire Protection Analysis Project – 9220 Zanzibar Lane Maple Grove, Mn, Brian Vandal

Fire Protection Engineering: Culminating Experience Project Reports

This report contains an analysis of the life safety and fire protection features of a four-story apartment building in Maple Grove, Minnesota. The report is a part of the final project intended to meet the requirements for the Culminating Experience of the California Polytechnic Master of Science Fire Protection Engineering Program.

The apartment building chosen for the analysis is a mixed-use four-story wood-framed structure. The first floor of this structure includes office space for building management, a meeting space, and various electrical and mechanical spaces as well as apartments. There are exit stairways on each end of the structure extending …


Research Laboratory: Fire, Explosion, And Life Safety Analysis, Dennis A. Tuma Jun 2020

Research Laboratory: Fire, Explosion, And Life Safety Analysis, Dennis A. Tuma

Fire Protection Engineering: Culminating Experience Project Reports

This culminating report is a fire, explosion, and life safety evaluation of a Research Laboratory ("Laboratory") where significant quantities of flammable, combustible, and hazardous materials are used and stored. The report's initial portion provides a prescriptive-based analysis using applicable sections of the 2016 California Building Standard Codes and National Fire Protection Association (NFPA) standards. Because of the unique challenges to hazardous laboratory spaces, the prescriptive- based analysis includes both a review of codes applicable to all occupancies (e.g., egress, fire-resistance, building area), and codes applicable to Group H and L occupancies (e.g., electrical area classification maps, control areas). Unfortunately, detailed …


Recreation Center- Cal Poly- Fire And Life Safety Analysis, Hao Yan Jun 2017

Recreation Center- Cal Poly- Fire And Life Safety Analysis, Hao Yan

Fire Protection Engineering: Culminating Experience Project Reports

This report discusses the fire and life safety analysis of the existing fire protection features installed in the Recreation Center building on the California Polytechnic State University. The analysis is conducted using two different approaches, the prescriptive analysis of the building and the performance-based design analysis.

The prescriptive analysis approach will examine installed fire protection features and systems in accordance with the International Building Code, such as structural fire protection, water-based suppression system, alarm and detection system, egress system, smoke control, and fire safety management plan. The egress system failed when the old gym area was used as a fixed …


Analysis Of Costco, San Francisco, Ian Levine Jun 2016

Analysis Of Costco, San Francisco, Ian Levine

Fire Protection Engineering: Culminating Experience Project Reports

This report provides an in-depth analysis of the fire safety systems and design considerations of the Costco store located at 450 10th Street in San Francisco, California, satisfying the requirements for completion of the FPE 596 – Culminating Experience in Fire Protection Engineering academic series. The building is introduced, followed by an analysis of the building structure, alarm and detection, egress, and sprinkler systems are designed based on prescriptive code. These systems are then analyzed from a performance based perspective to gain understanding of how the systems will respond to a challenging design fire. Their response is used to determine …


Fire And Life Safety Analysis- Building 310- The Landing, Tyler Paller Mar 2015

Fire And Life Safety Analysis- Building 310- The Landing, Tyler Paller

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of this report is to analyze Building 310 with regards to fire and life safety. Analysis was done both prescriptively and from a performance based design standpoint. The prescriptive based analysis includes review of the building’s design with regards to egress, fire alarm systems, suppression systems, and structural fire protection. The building was reviewed against current NFPA codes and the International Building Code to examine compliance. The performance-based analysis consists of two different fire scenarios that were examined. The goal was to show that the building met safety criteria and does not pose undue risk to occupants. This …


Fire Protection And Life Safety Evaluation- Houston Community College- San Jacinto Building, Will Clay Jun 2014

Fire Protection And Life Safety Evaluation- Houston Community College- San Jacinto Building, Will Clay

Fire Protection Engineering: Culminating Experience Project Reports

This report evaluates the life safety features of the HCC San Jacinto Building (SJB) both prescriptively and on a performance basis. The goal is to present the building code requirements for the HCC San Jacinto building and determine if the design is in compliance, as well as analyze the building on the basis of performance criteria to determine if there are any excessive threats to life safety. The building is designed in compliance with the Houston Building Code, and takes advantage of lesser requirements for existing features. The performance section determines that based on fire and egress modeling, that while …


Fire And Life Safety Analysis- Uw Medicine Lake Union Phase 3.1, Marge Hong Jun 2014

Fire And Life Safety Analysis- Uw Medicine Lake Union Phase 3.1, Marge Hong

Fire Protection Engineering: Culminating Experience Project Reports

This report provides a summary of the fire protection and life safety features for UW Medicine Lake Union, a research and laboratory building, in accordance with Seattle Building Code (SBC), International Building Code (IBC), and Life Safety Code (NFPA 101). The objective of this report is to identify if UW Medicine Lake Union meets both the prescriptive and performance based code. The primary fire safety goal is to provide life safety system that reduced the risk of fire-related injuries and loss of life due to fire. The prescriptive analysis is used to identify the building integrity per code. This evaluates …


Westside Christian High School, Michael Stewart Jun 2014

Westside Christian High School, Michael Stewart

Fire Protection Engineering: Culminating Experience Project Reports

The building I have chosen to use as the model for exemplifying the components of a wet fire suppression system is Westside Christian High School (WCHS). This building completed construction in January of 2014 and is located at: 8200 SW Pfaffle Street Tigard, Oregon 97223. The existing structure was previously owned and occupied by City Bible Church who will now lease space from the High school during and after construction. The renovations include the addition of space for music, art classes, fitness center, gym, science labs, and others. The renovations will also be widening existing rooms and hallways. The core …


Cal Poly Student Recreation Center Fire Protection Review, Alain N. Mamada Jun 2014

Cal Poly Student Recreation Center Fire Protection Review, Alain N. Mamada

Fire Protection Engineering: Culminating Experience Project Reports

This report summarizes the analysis of the existing fire protection features and systems installed in the Recreation Center building on the Cal Poly campus. The analysis is conducted into two different approaches. A prescriptive analysis approach will examine installed fire protection features and systems in accordance with the International Building Code. The analysis will consider the building as existing building as per IBC provisions. A performance-based approach will assess whether the building occupants will egress the building before conditions become untenable. Fire dynamic simulations will be used to determine the available safe egress time and evacuation simulations will performed to …


Culminating Project- U.S. Federal Courthouse, Joshua W. Elvove Jun 2013

Culminating Project- U.S. Federal Courthouse, Joshua W. Elvove

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of this report is to select and evaluate a building for compliance with prescriptive and performance based requirements, that apply the concepts learned from previous courses taken as part of the master’s fire protection engineering degree curriculum at Cal Poly, San Luis Obisbo. The report discusses applicable code requirements for building construction, egress, fire alarm initiation and notification, and fire suppression and evaluates the building’s performance, including occupant movement, when subjected to two assumed fires. Fire Dynamics Simulator (FDS) was used to generate data used during the performance analysis. The performance analysis reveals that meeting prescriptive requirements doesn’t …