Open Access. Powered by Scholars. Published by Universities.®

Other Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Fire Protection Engineering: Culminating Experience Project Reports

Pathfinder

Articles 1 - 20 of 20

Full-Text Articles in Other Engineering

A Fire Protection And Life Safety Analysis Of An Oupatient Healthcare System Building, Conrad Chandler Jun 2023

A Fire Protection And Life Safety Analysis Of An Oupatient Healthcare System Building, Conrad Chandler

Fire Protection Engineering: Culminating Experience Project Reports

The subject building of the report is an outpatient healthcare system building that is a two stories in height and 184,670 SF building. This building offers primary, specialty, and mental health outpatient care to patients throughout its state of location.

The facility is a mixed occupancy building with business as the primary occupancy, a surgery suite that classifies as an ambulatory health care occupancy, and assembly uses in the conference rooms, kitchen, and canteen. The Authority Having Jurisdiction (AHJ) has adopted the National Fire Codes (NFC) published by the National Fire Protection Association (NFPA), and throughout this report, the life …


Process Support Building Savannah River Site, Victoria Zawacki Jun 2022

Process Support Building Savannah River Site, Victoria Zawacki

Fire Protection Engineering: Culminating Experience Project Reports

A report on the fire and life safety analysis of the Savannah River Site Process Support Building is required in order to receive a Master of Science in Fire Protection Engineering from the California Polytechnic State University, San Luis Obispo. The Process Support Building is a two-story office building that was first occupied in 2013, with a floor area of approximately 10,000 ft2. The building contains mainly personal offices, but also contains conference and turnover rooms, a Computer Simulation Room, an Observation Room, and a lunch area. The analysis includes both prescriptive and performance-based analysis.

The Process Support Building is …


Fire Protection And Life Safety Analysis Of A University Conference Center, Amanda Beck Larkin Jun 2022

Fire Protection And Life Safety Analysis Of A University Conference Center, Amanda Beck Larkin

Fire Protection Engineering: Culminating Experience Project Reports

This project report analyzes various aspects of fire protection and life safety design for a University Conference Center, for both prescriptive and performance-based designs. The University Conference Center is a ten-story, high-rise building comprised of various gathering spaces, ranging from small conference rooms to large assembly spaces with auditorium-style seating. The building has a large two-story podium with basement below, with a smaller floor plate, ten-story tower offset to one side.

In the prescriptive analysis, no deficiencies were noted in the water-based suppression or fire resistance analysis. The building construction type, height, area, number of stories, wall and structural ratings, …


Fire Protection Analysis Project – 9220 Zanzibar Lane Maple Grove, Mn, Brian Vandal Jun 2022

Fire Protection Analysis Project – 9220 Zanzibar Lane Maple Grove, Mn, Brian Vandal

Fire Protection Engineering: Culminating Experience Project Reports

This report contains an analysis of the life safety and fire protection features of a four-story apartment building in Maple Grove, Minnesota. The report is a part of the final project intended to meet the requirements for the Culminating Experience of the California Polytechnic Master of Science Fire Protection Engineering Program.

The apartment building chosen for the analysis is a mixed-use four-story wood-framed structure. The first floor of this structure includes office space for building management, a meeting space, and various electrical and mechanical spaces as well as apartments. There are exit stairways on each end of the structure extending …


Jack E Brown Chemical Engineering Building At Texas A&M University, Daniel Higdon Jun 2022

Jack E Brown Chemical Engineering Building At Texas A&M University, Daniel Higdon

Fire Protection Engineering: Culminating Experience Project Reports

The Jack E Brown Chemical Engineering building at Texas A&M is located in College Station, TX. While this building is dedicated to chemical engineering, it serves many different departments as they use the lecture halls on the first floor. It was built and opened in 2004 and has 206,500 square feet with 7 stories. The building consists of multiple labs as well as study hall rooms, computer labs, offices, and the normal MEP/storage rooms. Jack E Brown building is one of the foremost buildings of the Texas A&M engineering quadrant and is further proof that Texas A&M desires to keep …


Prescriptive And Performance-Based Analysis Of Colorado Liberal Arts College, Victor Wight Jun 2022

Prescriptive And Performance-Based Analysis Of Colorado Liberal Arts College, Victor Wight

Fire Protection Engineering: Culminating Experience Project Reports

This project consists of a prescriptive and performance-based analysis of an existing two-story college building. The building is located in downtown Colorado Springs, Colorado. Colorado Liberal Arts College is used for general education courses with the focus on creative fields such as dance, graphic design, and art. The building consists of classrooms, offices, an art gallery, dance studio, and a bookstore.

A prescriptive based design was completed using the code requirements laid out in the International Building Code (IBC) 2015 Edition and applicable National Fire Protection Association (NFPA) Codes. The prescriptive based analysis consisted of analyzing life safety and egress, …


Fire Protection Analysis For The Tritium Engineering Building, Jack Smeck Jun 2021

Fire Protection Analysis For The Tritium Engineering Building, Jack Smeck

Fire Protection Engineering: Culminating Experience Project Reports

This report analyzed several different aspects of the fire protection and life safety strategy for the Tritium Engineering Building (TEB) at the Savannah River Site in Aiken, SC. The TEB is a single-story, Type IIB building that primarily houses engineering and technical staff. The building is approximately 15,560 ft2 and consists of two large “open areas” enclosed by hard- wall offices. Modular workstations are located in both “open areas” and accommodate the majority of the building occupants. This analysis provided both a prescriptive and a performance-based approach for analyzing fire hazards within the building. The prescriptive- based analysis evaluated the …


Tucson Student Housing, Abraham Coria Jun 2021

Tucson Student Housing, Abraham Coria

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of this report is to perform a two-part analysis of Tucson Student Housing’s fire protection design components. The two-part analysis consists of a prescriptive analysis, and a performance-based analysis. The purpose of the prescriptive-based analysis is to verify Tucson Student Housing meets or exceeds applicable construction standards. The prescriptive based analysis reviews the fire resistance of building elements, flammability of interior finishes, wet suppression system, fire alarm system, voice evacuation system, and occupant egress requirements. The performance-based analysis evaluates the performance of Tucson Student Housing’s fire protection systems when subjected to specified design fires. The design fire scenarios …


Fire Protection And Life Safety Analysis: Canyon Vista Dining Renovation- University Of California San Diego, Paul Ian Jungco Cabasag Jun 2021

Fire Protection And Life Safety Analysis: Canyon Vista Dining Renovation- University Of California San Diego, Paul Ian Jungco Cabasag

Fire Protection Engineering: Culminating Experience Project Reports

The Canyon Vista Dining project is a renovation of an existing two-story dining facility located in the Warren College area of the University of California San Diego campus for the owners, Housing, Dining and Hospitality. The renovation scope of work comprised a new dining experience with a better diversity of food options and indoor and outdoor seating, which upgraded the first floor, second floor, and mechanical penthouse. In the course of the design and construction, the prescriptive, performance, wildfire, and due diligence design results were utilized during discussions with design team and building permit approval. The project construction was completed …


Fire Protection Analysis Of Johnson Controls Office Building, Derek Driscoll Jun 2021

Fire Protection Analysis Of Johnson Controls Office Building, Derek Driscoll

Fire Protection Engineering: Culminating Experience Project Reports

This project report contains a fire and life safety analysis of the Johnson Controls Office Building. The building is located in Los Angeles, California. The building is a mixed use occupancy with office spaces, meeting rooms, training rooms, and a warehouse for storing fire sprinkler and fire alarm materials. The building is one level with a mezzanine. It is attached to another building and separated by fire barrier so that they are considered separate buildings. This report contains a prescriptive analysis and a performance-based design analysis of the building.

The prescriptive code requirements were determined based on the 2019 edition …


Fire Protection And Life Safety Analysis Of A Chicago Hotel, Thomas Hampton Jun 2020

Fire Protection And Life Safety Analysis Of A Chicago Hotel, Thomas Hampton

Fire Protection Engineering: Culminating Experience Project Reports

The following report contains an analysis of the life safety and fire protection features of a Chicago Hotel. The report is intended to meet the requirements for the Culminating Experience of the Cal Poly Master of Science Fire Protection Engineering Program.

The Chicago Hotel building chosen for the analysis is a mixed-use 7-story hotel. On the 1st, 2nd, and 7th floors of the building are spaces for mercantile and restaurant tenants as well as other spaces necessary for the operation of the building such as back of house space for the hotel, storage, employee locker rooms, hotel and retail lobbies, …


Silverton Timeshare Tower “The Berkley”, Kevin Murphy Jun 2019

Silverton Timeshare Tower “The Berkley”, Kevin Murphy

Fire Protection Engineering: Culminating Experience Project Reports

The Berkley (aka the Silverton Timeshare Tower) was reviewed for compliance with the code of record. This included review of the full architectural set of drawings, as well as the available Fire Protection Report and Amendments that were issued prior to and during construction. This analysis has been slowly performed throughout the extent of my graduate career at California Polytechnic State University, San Luis Obispo (Cal Poly), and has been in depth for each applicable area of study. Each of the studies performed will be reviewed in the applicable sections below, be it for prescriptive analysis of the existing facility …


Fire Protection Engineering Final Report: Baylor Scott & White Medical Center, College Town, Tx, Jonathan Lo Jun 2019

Fire Protection Engineering Final Report: Baylor Scott & White Medical Center, College Town, Tx, Jonathan Lo

Fire Protection Engineering: Culminating Experience Project Reports

This report examines the Baylor, Scott & White Medical Center in College Station, TX. This hospital is a 324,070 square feet midrise building of Type I-A construction and Group I-2 occupancy, with a basement and five above-grade floors. Publicly-available, simplified floor plans were obtained from the internet, and a prescriptive- and performance-based analysis was formed around these plans. It should be noted that these online plans may not contain all information and details in that are found in architectural plans, and that assumptions were made in order to ‘fill in the gaps’ and proceed with this report. For example, on …


Life Safety And Fire Analysis - Aircraft Hangar, Frederick J. Tanis Jr. Jun 2018

Life Safety And Fire Analysis - Aircraft Hangar, Frederick J. Tanis Jr.

Fire Protection Engineering: Culminating Experience Project Reports

A hangar originally built in 1958 then modified and expanded over the years was evaluated using both the prescriptive requirements and a performance analysis. For the prescriptive analysis the building was evaluated against the 2015 International Building Code and the current NFPA codes and in a few cases the Department of Defense (DoD) Unified Facilities Criteria (UFC). During the prescriptive analysis a few areas were identified that do not meet the current codes due to areas being broken up into separate rooms and hallways and rooms being separated by security doors that only allow unobstructed travel in one direction. These …


General Purpose Laboratory Building 33- Lawrence Berkeley National Laboratory, Nicholas Tran Jun 2018

General Purpose Laboratory Building 33- Lawrence Berkeley National Laboratory, Nicholas Tran

Fire Protection Engineering: Culminating Experience Project Reports

A detailed study of the fire and life safety systems in the General Purpose Laboratory at the Lawrence Berkeley National Laboratory was performed. The prescriptive and performance-based methods for fire and life safety requirements were analyzed in accordance with the applicable codes. The prescriptive items examined included the egress capacities, fire suppression systems, fire detection and notification systems, and structural construction requirements. The performance-based models utilized studied fire growth and its impact on the fire suppression systems as well as time to egress for the occupants. The General Purpose Laboratory was found to be compliant with the prescriptive requirements in …


Dci Data Center Building- Fire Protection Analysis, Bryan Hathaway Jun 2017

Dci Data Center Building- Fire Protection Analysis, Bryan Hathaway

Fire Protection Engineering: Culminating Experience Project Reports

A fire protection analysis utilizing prescriptive and performance based design was performed for the existing building (DCIB) located in Minnesota. A new tenant is investigating converting the DCIB from a building used for data center, to an office building which will utilize an open office concept.

A prescriptive analysis of the building was performed to determine the life safety, fire suppression, fire alarm and structural requirements to ensure compliance with current applicable codes and standards. The prescriptive requirements are outlined and reviewed in Section 1 through Section 5 of this analysis. Modifications to the DCIB are required to achieve the …


Recreation Center- Cal Poly- Fire And Life Safety Analysis, Hao Yan Jun 2017

Recreation Center- Cal Poly- Fire And Life Safety Analysis, Hao Yan

Fire Protection Engineering: Culminating Experience Project Reports

This report discusses the fire and life safety analysis of the existing fire protection features installed in the Recreation Center building on the California Polytechnic State University. The analysis is conducted using two different approaches, the prescriptive analysis of the building and the performance-based design analysis.

The prescriptive analysis approach will examine installed fire protection features and systems in accordance with the International Building Code, such as structural fire protection, water-based suppression system, alarm and detection system, egress system, smoke control, and fire safety management plan. The egress system failed when the old gym area was used as a fixed …


Technical Area 3 - 40; Physics Building- Fire And Life Safety Analysis, Parker Fellows Mar 2016

Technical Area 3 - 40; Physics Building- Fire And Life Safety Analysis, Parker Fellows

Fire Protection Engineering: Culminating Experience Project Reports

A Fire Protection Engineering Analysis was performed on TA‐3‐0040, Physics Building at the Los Alamos National Laboratory in Los Alamos, New Mexico. The goal of the analysis has two parts; first, to examine the buildings fire protection features from a code based prescriptive analysis and second, to examine the building and fire protection features using a performance based design analysis.

Building 40 is a 2 story structure approximately 187,000 square feet. The building was constructed in the mid‐1950s with a first floor, basement, partial sub‐basement, and various mezzanines. Originally, this building was constructed as a non‐combustible type IIB structure according …


Fire Hazard Analysis Of Technical Area 53 Building 1, Los Alamos National Lab, Brett L. Noakes Jun 2015

Fire Hazard Analysis Of Technical Area 53 Building 1, Los Alamos National Lab, Brett L. Noakes

Fire Protection Engineering: Culminating Experience Project Reports

This is an analysis of a 1970’s vintage building as it is compared to current building codes and standards. The purpose of this document is to assess if the current, as found construction of an existing building could achieve the sometimes more restrictive modern building codes. Both a prescriptive analysis and a performance-based analysis were completed to verify life-safety concerns and criteria as well as construction criteria. The prescriptive analysis compared existing, as found construction to current codes and standards while the prescriptive analysis used modern fire modeling techniques to see how likely fire scenarios would challenge the structure, if …


Cal Poly Student Recreation Center Fire Protection Review, Alain N. Mamada Jun 2014

Cal Poly Student Recreation Center Fire Protection Review, Alain N. Mamada

Fire Protection Engineering: Culminating Experience Project Reports

This report summarizes the analysis of the existing fire protection features and systems installed in the Recreation Center building on the Cal Poly campus. The analysis is conducted into two different approaches. A prescriptive analysis approach will examine installed fire protection features and systems in accordance with the International Building Code. The analysis will consider the building as existing building as per IBC provisions. A performance-based approach will assess whether the building occupants will egress the building before conditions become untenable. Fire dynamic simulations will be used to determine the available safe egress time and evacuation simulations will performed to …