Open Access. Powered by Scholars. Published by Universities.®
Biomedical Engineering and Bioengineering Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Medicine and Health Sciences (1509)
- Life Sciences (1276)
- Biological Engineering (1224)
- Biomedical Devices and Instrumentation (1154)
- Mechanical Engineering (1007)
-
- Chemical Engineering (851)
- Molecular, Cellular, and Tissue Engineering (769)
- Electrical and Computer Engineering (703)
- Bioimaging and Biomedical Optics (690)
- Physical Sciences and Mathematics (680)
- Biomaterials (675)
- Biomechanics and Biotransport (593)
- Other Biomedical Engineering and Bioengineering (525)
- Materials Science and Engineering (490)
- Medical Specialties (450)
- Bioelectrical and Neuroengineering (407)
- Civil and Environmental Engineering (315)
- Biochemical and Biomolecular Engineering (314)
- Computer Engineering (301)
- Biochemistry, Biophysics, and Structural Biology (299)
- Medical Sciences (279)
- Biomedical (270)
- Biomechanical Engineering (262)
- Computer Sciences (262)
- Analytical, Diagnostic and Therapeutic Techniques and Equipment (259)
- Cell and Developmental Biology (208)
- Nanoscience and Nanotechnology (193)
- Biotechnology (189)
- Institution
-
- Marquette University (725)
- University of Nebraska - Lincoln (697)
- California Polytechnic State University, San Luis Obispo (643)
- Old Dominion University (528)
- Engineering Conferences International (510)
-
- New Jersey Institute of Technology (478)
- Utah State University (465)
- University of Arkansas, Fayetteville (437)
- Purdue University (417)
- University of Texas at Arlington (366)
- Wright State University (321)
- Virginia Commonwealth University (314)
- Clemson University (300)
- University of Kentucky (296)
- Missouri University of Science and Technology (288)
- City University of New York (CUNY) (223)
- Michigan Technological University (214)
- Washington University in St. Louis (212)
- Cleveland State University (193)
- University of South Florida (166)
- Santa Clara University (155)
- Dartmouth College (153)
- Technological University Dublin (152)
- Wayne State University (137)
- Boise State University (128)
- University of South Carolina (127)
- Rowan University (126)
- Louisiana Tech University (117)
- Al Esraa University (115)
- Florida Institute of Technology (109)
- Keyword
-
- Biomechanics (192)
- Biomedical Sciences (144)
- Tissue engineering (136)
- Biomaterials (119)
- Engineering (118)
-
- Cancer (111)
- Department of Biomedical Engineering (104)
- Machine learning (100)
- Microfluidics (99)
- Humans (94)
- Applied sciences (92)
- Biomedical Engineering (92)
- Nanoparticles (88)
- Biomedical engineering (87)
- Daniel Felix Ritchie School of Engineering and Computer Science (86)
- Bone (83)
- Drug delivery (80)
- Electrospinning (80)
- Department of Biomedical, Industrial & Human Factors Engineering (78)
- Bioengineering (75)
- Tissue Engineering (72)
- Electroporation (67)
- EEG (65)
- Hydrogel (62)
- Deep learning (58)
- Gait (57)
- Ultrasound (57)
- Imaging (56)
- Magnetic resonance imaging (55)
- Rehabilitation (54)
- Publication Year
- Publication
-
- Biomedical Engineering Faculty Research and Publications (606)
- Theses and Dissertations (531)
- Theses (386)
- Master's Theses (304)
- Department of Agricultural and Biological Systems Engineering: Faculty Publications (297)
-
- Biomedical Engineering (278)
- Chemical and Biochemical Engineering Faculty Research & Creative Works (247)
- Cell Culture Engineering XV (246)
- Electronic Theses and Dissertations (232)
- Browse all Theses and Dissertations (224)
- Bioengineering Theses - Archive (194)
- McKelvey School of Engineering Graduate Student Theses & Dissertations (191)
- Cells and Materials (166)
- USF Tampa Graduate Theses and Dissertations (162)
- Bioelectrics Publications (158)
- Biomedical Engineering Undergraduate Honors Theses (155)
- All Dissertations (148)
- Graduate Theses and Dissertations (133)
- Bioengineering Dissertations - Archive (131)
- The Summer Undergraduate Research Fellowship (SURF) Symposium (127)
- Weldon School of Biomedical Engineering Faculty Publications (127)
- Doctoral Dissertations (123)
- All Theses (120)
- ETD Archive (119)
- Al-Esraa University College Journal for Engineering Sciences (115)
- Dissertations (113)
- Dissertations and Theses (107)
- Publications and Research (103)
- Bioengineering Senior Theses (99)
- Biomedical, Industrial & Human Factors Engineering Faculty Publications (95)
- Publication Type
- File Type
Articles 2521 - 2550 of 11560
Full-Text Articles in Biomedical Engineering and Bioengineering
Active Testing Of Executive Functions: Toward More Efficient And Equitable Individual Behavioral Modeling, Mariluz Rojo Domingo
Active Testing Of Executive Functions: Toward More Efficient And Equitable Individual Behavioral Modeling, Mariluz Rojo Domingo
McKelvey School of Engineering Graduate Student Theses & Dissertations
Inferences about executive functions are commonly drawn through serial administration of various individual assessments that often take a long time to complete and cannot capture complex trends across multiple variables. In an attempt to improve upon current methods used to estimate latent brain constructs, this thesis makes two primary contributions to the field of behavioral modeling. First, it brings attention to sequential designs for more efficient diagnostic testing of fluctuations in executive functions with respect to a baseline level. It was shown that a sequential framework was successfully capable of detecting significant differences in cognitive performance more rapidly than conventional …
Application Of Neural Networks To Predict Patient-Specific Cellular Parameters In Computational Cardiac Models, Chang Hi Lee
Application Of Neural Networks To Predict Patient-Specific Cellular Parameters In Computational Cardiac Models, Chang Hi Lee
McKelvey School of Engineering Graduate Student Theses & Dissertations
Sudden cardiac death(SCD) is a significant cause of death that accounts for more than 180,000 deaths in the US and 4 million deaths worldwide annually. SCDs are mainly caused by irregular heartbeats called arrhythmias, which are caused by abnormal electrical activity within the heart. Precision medicine, in the form of personalized computational cardiac models of a patient’s heart, can suggest optimal therapies for cardiac arrhythmias. Prior work has used finite element meshes derived from cardiac MRIs to simulate cardiac electrical activity. In this study, I sought to augment this approach by developing a neural network to learn the parameters that …
Optimal Design Of Bacterial Carpets For Fluid Pumping, Minghao W. Rostami, Weifan Liu, Amy Buchmann, Eva Strawbridge, Longhua Zhao
Optimal Design Of Bacterial Carpets For Fluid Pumping, Minghao W. Rostami, Weifan Liu, Amy Buchmann, Eva Strawbridge, Longhua Zhao
Biology and Medicine Through Mathematics Conference
No abstract provided.
Human Induced Mesenchymal Stem Cells Display Increased Sensitivity To Matrix Stiffness., Kirstene A Gultian, Roshni Gandhi, Khushi Sarin, Martina Sladkova-Faure, Matthew Zimmer, Giuseppe Maria De Peppo, Sebastian Vega
Human Induced Mesenchymal Stem Cells Display Increased Sensitivity To Matrix Stiffness., Kirstene A Gultian, Roshni Gandhi, Khushi Sarin, Martina Sladkova-Faure, Matthew Zimmer, Giuseppe Maria De Peppo, Sebastian Vega
Henry M. Rowan College of Engineering Departmental Research
The clinical translation of mesenchymal stem cells (MSCs) is limited by population heterogeneity and inconsistent responses to engineered signals. Specifically, the extent in which MSCs respond to mechanical cues varies significantly across MSC lines. Although induced pluripotent stem cells (iPSCs) have recently emerged as a novel cell source for creating highly homogeneous MSC (iMSC) lines, cellular mechanosensing of iMSCs on engineered materials with defined mechanics is not well understood. Here, we tested the mechanosensing properties of three human iMSC lines derived from iPSCs generated using a fully automated platform. Stiffness-driven changes in morphology were comparable between MSCs and iMSCs cultured …
Relationship Between Applied Load And Clearance In Suture Knots, Amena S. Shermadou, Steven R. Lindheim, Jerome L. Yaklic, Tarun Goswami
Relationship Between Applied Load And Clearance In Suture Knots, Amena S. Shermadou, Steven R. Lindheim, Jerome L. Yaklic, Tarun Goswami
Biomedical, Industrial & Human Factors Engineering Faculty Publications
Ethicon Coated Vicryl absorbable sutures of different diameters were studied in order to determine if a relationship exists between the load and measured clearance. A prototype was designed to simulate knot location. Tensile tests were conducted on the suture knots followed by clearance measurements after each load level was applied. From the results it was concluded that the measured clearance was directly proportional to the amount of load applied to the suture knot. Also, based on the diameter of the suture, the smaller the diameter, the lower was the total displacement of the knot or the clearance.
Study Of Cardiovascular Dynamics During Graded Head-Up Tilt Test In The Young With Syncope Tendency, Martin A. Miranda Sr
Study Of Cardiovascular Dynamics During Graded Head-Up Tilt Test In The Young With Syncope Tendency, Martin A. Miranda Sr
Biology and Medicine Through Mathematics Conference
No abstract provided.
Gender-Specific Anterior Cruciate Ligament – Gait Forces, Bharadwaj Cheruvu, Amy Neidhard-Doll, Tarun Goswami
Gender-Specific Anterior Cruciate Ligament – Gait Forces, Bharadwaj Cheruvu, Amy Neidhard-Doll, Tarun Goswami
Biomedical, Industrial & Human Factors Engineering Faculty Publications
The purpose of this study was to investigate gender-based differences in gait biomechanics and to evaluate those effects on forces generated on the ACL during walking. Estimation of gender-specific ACL forces in the frontal plane can provide a better understanding of the biomechanical patterns underlying higher female injury risk. The present study used a sample from the Fels Longitudinal Study to test the hypothesis that there are significant gender-differences in frontal plane ACL loading during walking. A cross-sectional sample of 178 participants, including 79 males and 99 females was used to evaluate differences in gait kinetics. Females walked at higher …
Simulation Of Gene Regulatory Elements For Biosensing, Mallory Bates, Svetlana Harbough, Tarun Goswami
Simulation Of Gene Regulatory Elements For Biosensing, Mallory Bates, Svetlana Harbough, Tarun Goswami
Biomedical, Industrial & Human Factors Engineering Faculty Publications
Gene regulatory studies are of significant importance in many scenarios such as mental illness. 21% of U.S adults experience mental illnesses including 1 in 4 active-duty military personnel. Mental health can be identified in the body by different biomarkers. These biomarkers potentially controlled by riboswitches, which are located in mRNA and switch “ON” or “OFF” depending on the concentration of a biomarker. In this research, a known riboswitch reengineered and its response in the presence of a biomarker investigated. We changed computationally PreQ1, a known riboswitch that has the smallest aptamer, and then experimentally tested against biomarkers, dehydroepiandrosterone-sulfate …
Shape Memory Polymer Foaming With Tunable Interconnectivity Using Off-The-Shelf Foaming Components, Natalie Marie Petryk
Shape Memory Polymer Foaming With Tunable Interconnectivity Using Off-The-Shelf Foaming Components, Natalie Marie Petryk
Theses - ALL
The ability to tune pore structures of gas-blown polyurethane shape memory polymer (SMP) foams easily and safely could improve their outcomes as hemostatic dressings or tissue engineering scaffolds and overall commercialization efforts. Incorporating physical blowing agents into the polymer mix can be used to tune pore size and interconnectivity without altering foam chemistry. Enovate (HFC-254fa) is a commonly used physical blowing agent in gas-blown foams, but the Environmental Protection Agency (EPA) considers its use unacceptable because it is a hydrofluorocarbon that contributes to global warming. Here, off-the-shelf solvents accepted for use by the EPA, acetone, dimethyoxymethane (methylal), and methyl formate, …
Aerodynamics And Turbulent Wake-Flow Characteristics Of Owls During Flapping Flight, Krishnamoorthy Krishnan
Aerodynamics And Turbulent Wake-Flow Characteristics Of Owls During Flapping Flight, Krishnamoorthy Krishnan
Electronic Theses and Dissertations
Owls exhibit unique flight capabilities in the low Reynolds number flow regime which is prone to complex viscous flow phenomena. They possess unique feather features and flexible wing structures which are postulated to help them fly nearly silently and stably at low speeds in a complex flow setting. Understanding the aerodynamics of owls could pave the way to enhance the future designs of small flying vehicles. Though it has been a focus of research over multiple decades, no conclusive agreement has been attained on the aerodynamic mechanisms associated with owl flight. Particularly, the aerodynamics of flapping owl flight is severely …
Atomistic Investigation Of Nucleosomal H3 Histone Tail In Unmodified And Epigenetically Modified States, Kathryn Piston
Atomistic Investigation Of Nucleosomal H3 Histone Tail In Unmodified And Epigenetically Modified States, Kathryn Piston
Dissertations - ALL
Epigenetics is a growing area of research that could potentially unlock the understanding of questions like how and why we develop certain diseases, how we age, how we inherit certain traits and even how our species evolves. Epi is a prefix meaning above, referring to chemical tags that sit above your genetics and dictate gene expression. Although there are many known links between certain epigenetic tags and diseases like cancer, the molecular mechanisms behind these links remains elusive. Gaining a novel understanding of the behavior of key biological targets for cancer like the histone H3 tail motivated this work. Histone …
Development Of New, Diverse Triggering Mechanisms Of Shape Memory Polymers For Cell Mechanobiology Studies, Mark Macios
Development Of New, Diverse Triggering Mechanisms Of Shape Memory Polymers For Cell Mechanobiology Studies, Mark Macios
Theses - ALL
Over the past decade, several shape-memory polymer (SMP) substrates capable of changing topography under cell-culture conditions have been developed for the study of cell mechanobiology. Most initial reports of cytocompatible SMP platforms employed thermal triggering under ambient heating conditions, which, especially in hydrated environments, is a slow process that generally takes several minutes to a few hours. Also, biocompatible SMPs initially featured recovery temperatures too high for cells to maintain viability during the thermal trigger. To overcome the limitations of ambient thermal heating triggered shape recovery, the goal of this thesis was to develop new cytocompatible SMPs that can trigger …
Manipulated Electrochemical Surface Reactions Induced By Oscillatory Electric Potentials On Metal Based Electrodes, Thomas Stone Welles
Manipulated Electrochemical Surface Reactions Induced By Oscillatory Electric Potentials On Metal Based Electrodes, Thomas Stone Welles
Dissertations - ALL
This research effort investigates the manipulation of surface electrochemical reactions induced by oscillating electric potentials on the surface of metal-based electrodes. Specifically, this research presents experimental data identifying modified electrochemical surface reactions caused by low magnitude electric potential oscillations on multilayered catalytic membranes and on implanted biometallic alloys. The scope of this effort consists of four major components: (1) perform an exhaustive literature review and analysis of the current understanding in applied surface electrochemistry and develop potential theoretical frameworks by which to interpret the experimental results; (2) identify the electrochemical manipulation via electrical oscillation while reacting nitric oxide on a …
Closed-Loop Brain-Computer Interfaces For Memory Restoration Using Deep Brain Stimulation, David Xiaoliang Wang
Closed-Loop Brain-Computer Interfaces For Memory Restoration Using Deep Brain Stimulation, David Xiaoliang Wang
Electrical Engineering Theses and Dissertations
The past two decades have witnessed the rapid growth of therapeutic brain-computer interfaces (BCI) targeting a diversity of brain dysfunctions. Among many neurosurgical procedures, deep brain stimulation (DBS) with neuromodulation technique has emerged as a fruitful treatment for neurodegenerative disorders such as epilepsy, Parkinson's disease, post-traumatic amnesia, and Alzheimer's disease, as well as neuropsychiatric disorders such as depression, obsessive-compulsive disorder, and schizophrenia. In parallel to the open-loop neuromodulation strategies for neuromotor disorders, recent investigations have demonstrated the superior performance of closed-loop neuromodulation systems for memory-relevant disorders due to the more sophisticated underlying brain circuitry during cognitive processes. Our efforts are …
Investigating The Effect Of Dissolved Oxygen-Assisted Corneal Cross-Linking (Cxl) On Porcine Corneas, Julianni Dar
Investigating The Effect Of Dissolved Oxygen-Assisted Corneal Cross-Linking (Cxl) On Porcine Corneas, Julianni Dar
Electronic Theses and Dissertations
Corneal cross-linking is a clinical procedure that is known to stop the progression of keratoconus, an eye disease that affects the cornea’s structure, ultimately leading to vision loss in its advanced stages. The typical treatment plan includes riboflavin and UV-A exposure in the hope to increase the mechanical properties of the cornea. There are two types of CXL pathways, with Type-II CXL requiring oxygen. Naturally, the dissolved oxygen is limited in the cornea; therefore, limiting the effect of Type-II CXL. This study proposes to improve the Type-II CXL contribution by integrating dissolved oxygen during the standard CXL treatment used in …
A Microfluidic Assay For Single Cell Bacterial Adhesion Studies Under Shear Stress, Amanda Trusiak
A Microfluidic Assay For Single Cell Bacterial Adhesion Studies Under Shear Stress, Amanda Trusiak
Electronic Theses and Dissertations
The study of bacterial adhesion to host cells is important in understanding bacterial pathogenesis and developing new therapeutic approaches. Here, we studied bacterial adhesion under shear stress using a novel microfluidic method. Specifically, the adhesion of a uropathogenic E. coli strain (FimHOn, ATCC 700928/CFT073) to mannose-modified substrates was studied under flow conditions. The FimHOn E. coli strain expresses FimH which is a mannose-specific adhesin found on the fimbriae that binds to glycoproteins on the epithelium. We developed a microfluidic method that mimics bacterial adhesion to urothelial cells. First, the microfluidic channels were modified by sequentially adsorbing BSA-mannose and BSA onto …
A Comparative Study On The Functionality Of Porcine Dura As A Tissue-Engineered Dura Mater Graft For Clinical Applications, Ashma Sharma
A Comparative Study On The Functionality Of Porcine Dura As A Tissue-Engineered Dura Mater Graft For Clinical Applications, Ashma Sharma
Theses and Dissertations
Damage to dura mater may occur during intracranial or spinal surgeries, which can result in cerebrospinal fluid leakage as well as other potentially fatal physiological changes. As a result, biological scaffolds derived from xenogeneic materials are typically used to repair and regenerate dura mater post intracranial or spinal surgeries. In this study we explore the mechanics, structure, and immunological capacity of xenogeneic dura mater to be considered as a replacement for human dura. A comparative analysis is done between native porcine dura and a commercially available bovine collagen-based dura graft. Native porcine dura mater was decellularized and subjected to mechanical …
Scandy: Simulating Realistic Human Scanpaths In Dynamic Real-World Scenes, Nicolas Roth, Martin Rolfs, Klaus Obermayer
Scandy: Simulating Realistic Human Scanpaths In Dynamic Real-World Scenes, Nicolas Roth, Martin Rolfs, Klaus Obermayer
MODVIS Workshop
No abstract provided.
Molecular-Level Control Over Ionic Conduction And Ionic Current Direction By Designing Macrocycle-Based Ionomers, Shyambo Chatterjee, Ehsan Zamani, Seefat Farzin, Iman Evazzade, Oghenetega Allen Obewhere, Tyler James Johnson, Vitaly Alexandrov, Shudipto Konika Dishari
Molecular-Level Control Over Ionic Conduction And Ionic Current Direction By Designing Macrocycle-Based Ionomers, Shyambo Chatterjee, Ehsan Zamani, Seefat Farzin, Iman Evazzade, Oghenetega Allen Obewhere, Tyler James Johnson, Vitaly Alexandrov, Shudipto Konika Dishari
Department of Chemical and Biomolecular Engineering: Faculty Publications
Poor ionic conductivity of the catalyst-binding, submicrometer- thick ionomer layers in energy conversion and storage devices is a huge challenge. However, ionomers are rarely designed keeping in mind the specific issues associated with nanoconfinement. Here, we designed nature-inspired ionomers (calix-2) having hollow, macrocyclic, calix[4]arene-based repeat units with precise, sub-nanometer diameter. In ≤100 nm-thick films, the in-plane proton conductivity of calix-2 was up to 8 times higher than the current benchmark ionomer Nafion at 85% relative humidity (RH), while it was 1−2 orders of magnitude higher than Nafion at 20−25% RH. Confocal laser scanning microscopy and other synthetic techniques allowed us …
The Synthesis And Characterization Of Ionic Liquids Using Nitrogen-Based Cations For Transdermal Delivery, Jo Galloway
The Synthesis And Characterization Of Ionic Liquids Using Nitrogen-Based Cations For Transdermal Delivery, Jo Galloway
Honors Theses
The purpose of this research was to explore the synthesis mechanisms of water-soluble ionic liquids with nitrogen-containing cationic bases for future use in transdermal drug delivery and forensic science applications. Ionic liquids are salts with an organic cation and either an organic or inorganic anion. They have asymmetric structures, which means that the molecules don’t pack together as neatly as other salts do, therefore, they don’t crystallize as easily, and their melting points are lower. Ionic liquids have melting points below 100°C, and many are liquid at room temperature. Mechanistic studies reveal that the potency of ILs in enhancing transdermal …
Manual Material Handling Lift-Assist System For Occupational Exoskeleton, Erik Goes, Daniel Guthrie, Trevor Ward
Manual Material Handling Lift-Assist System For Occupational Exoskeleton, Erik Goes, Daniel Guthrie, Trevor Ward
Honors Capstones
It is no secret that lifting heavy objects is one of the premier causes of workplace injury, and the modern worker needs help to remain healthy. Workers need something they always have with them that makes their work safer as well as easier; our solution is an active lift-assist exoskeleton. The proposed exoskeleton design includes a military backpack exoskeleton frame, on which two actuators pull cables attached to end effectors that the operator will be holding. This system can adjust to conform to a wide variety of operator sizes, without restricting any of their range of motion. This leads to …
Novel Keyed Fusion Method To Improve Plate Alignment In Anterior Cervical Discectomy And Fusion Procedures, Henry Seiler
Novel Keyed Fusion Method To Improve Plate Alignment In Anterior Cervical Discectomy And Fusion Procedures, Henry Seiler
Honors Theses
Anterior cervical discectomy and fusion (ACDF) is a form of neck surgery that is performed to remove a damaged disc in the spine. Without intervention damaged discs in the spine cause a buildup of spinal cord or nerve root pressure which can lead to several unpleasant side effects. The current methods and devices through which this surgery is carried out can be potentially problematic for both the surgeon and the patient. Oftentimes surgeons have difficulty aligning the cervical plate typically used in ACDF surgeries. In many cases, these problems are unavoidable. It is for this reason that a group of …
Developing New Crutch Tip Design For Overall Increased Stability And Improved Movement On Different Terrains, Lauren Skinner
Developing New Crutch Tip Design For Overall Increased Stability And Improved Movement On Different Terrains, Lauren Skinner
Honors Theses
Crutches are a mobility assistive device that are often used in various situations, such as post- surgical rehabilitation and recovery after injury. The current crutch tip design that is used on today’s crutches are often unstable and do not provide quality movement on different terrains, such as snow, ice, mud, and wet surfaces. These problems would be solved with a new tip design that could be attached to existing crutches or manufactured with the crutch itself. The team’s solution to this problem is a crutch tip with modular parts. The tip would attach to the shaft of the crutch like …
Mobile, Biosensor Technology For Measuring Joint-Level Human Motion, Matthew Mcmanigal
Mobile, Biosensor Technology For Measuring Joint-Level Human Motion, Matthew Mcmanigal
Theses & Dissertations
The measurement of three-dimensional knee joint angles can predict both anterior cruciate ligament (ACL) injuries and the risk of developing early knee osteoarthritis. However, knee joint angle assessment is currently limited, due to the lack of validated wearable and untethered technologies that can be deployed in natural environments and rural or community settings. To address this challenge, this thesis project aimed to 1) develop a fully untethered, wearable electronic device to measure knee joint angles during natural human movement and 2) test the accuracy of the device to collect sagittal knee joint angles during dynamic activities of human movement. For …
Novel Mobility Device For Conjoined Twins, Allyson Bowgren
Novel Mobility Device For Conjoined Twins, Allyson Bowgren
Honors Capstones
This project provides a solution to a problem proposed by a pair of conjoined clients. With their desire to become fully independent, the clients need an improved mobility device. Being joined at the head, moving around was always difficult for them and their situation did not get any better after an accident left one of them immobile. Their current device was a decent and quick solution at the time it was first needed. However, since its conception the device quickly became obsolete, and they are now in need of a more effective device that allows them to travel easier. This …
Th1, Th2, And Th17 Inflammatory Pathways Predict Cardiometabolic Protein Expression In Serum Of Covid-19 Patients, James Richard Michels
Th1, Th2, And Th17 Inflammatory Pathways Predict Cardiometabolic Protein Expression In Serum Of Covid-19 Patients, James Richard Michels
Honors Theses
A predominant source of complications in SARS-CoV-2 patients arises from severe systemic inflammation contributed to by Helper T-cell associated cytokines, potentially leading to tissue damage and organ failure. The high inflammatory burden of this viral infection often results in cardiovascular comorbidities. A better understanding of the interaction between the cytokine storm and cardiovascular proteins might inform medical decisions and therapeutic approaches. We hypothesized that all major helper T-cell inflammatory pathways (Helper T 1, Helper T 2 and Helper T 17) synergistically contribute to cardiometabolic pathways in serum of COVID-19 patients, and that both of these factors correlate to COVID-19 severity. …
Increasing Accessibility To Monitoring Ammonia Levels In The Body Through Development Of A Novel Point-Of-Care Breath Ammonia Diagnostic Device, Emily C. Wright, Ashwin M. Sivalingam
Increasing Accessibility To Monitoring Ammonia Levels In The Body Through Development Of A Novel Point-Of-Care Breath Ammonia Diagnostic Device, Emily C. Wright, Ashwin M. Sivalingam
Honors Theses
Hyperammonemia is a life-threatening metabolic condition that is characterized by elevated levels of ammonia concentrations in the blood. Resulting from serious conditions such as chronic kidney disease or liver failure, the limited functions of the liver and kidney lead to an increase in blood urea nitrogen (BUN) within the body. Currently, there are a wide variety of treatments for this condition, ranging from various medications to surgical procedures such as liver transplants. However, there is a lack of variety in diagnostic testing methods to determine a patient’s ammonia levels. In most cases, patients will need to schedule a doctor’s appointment …
In-Vivo Damage Development In Vena Cava Filter: Study Of A Retrieved Device, Anne Marie Lutz, Tarun Goswami
In-Vivo Damage Development In Vena Cava Filter: Study Of A Retrieved Device, Anne Marie Lutz, Tarun Goswami
Biomedical, Industrial & Human Factors Engineering Faculty Publications
This article was prepared from a project assigned in a graduate class, BME 7371, Failure Assessment of Medical Devices, taught at Wright State University by the senior author. The device was donated for the study which was successfully retrieved after 93 days in-vivo. Even-though the mechanical integrity of the device held in-tact, the microscopic observations revealed that the damage via corrosion and scratching took place on the surface of the device. The image reconstructed in 3D using image-J software to determine device roughness and depth-of-pits. Results presented in this paper show that damage starts developing in these devices after the …
Electromechanical Fatigue Properties Of Dielectric Elastomer Stretch Sensors Under Orthopaedic Loading Conditions, Andrea Karen Persons
Electromechanical Fatigue Properties Of Dielectric Elastomer Stretch Sensors Under Orthopaedic Loading Conditions, Andrea Karen Persons
Theses and Dissertations
Fatigue testing of stretch sensors often focuses on high amplitude, low-cycle fatigue (LCF) behavior; however, when used for orthopaedic, athletic, or ergonomic assessments, stretch sensors are subjected to low amplitude, high-cycle fatigue (HCF) conditions. As an added layer of complexity, the fatigue testing of stretch sensors is not only focused on the life of the material comprising the sensor, but also on the reliability of the signal produced during the extension and relaxation of the sensor. Research into the development of a smart sock that can be used to measure the range of motion (ROM) of the ankle joint during …
Probing Myosin Ensemble Mechanics In Actin Filament Bundles Using Optical Tweezers, Omayma Al Azzam, Janie C. Watts, Justin E. Reynolds, Juliana E. Davis, Dana N. Reinemann
Probing Myosin Ensemble Mechanics In Actin Filament Bundles Using Optical Tweezers, Omayma Al Azzam, Janie C. Watts, Justin E. Reynolds, Juliana E. Davis, Dana N. Reinemann
Faculty and Student Publications
Myosins are motor proteins that hydrolyze ATP to step along actin filament (AF) tracks and are essential in cellular processes such as motility and muscle contraction. To understand their force-generating mechanisms, myosin II has been investigated both at the single-molecule (SM) level and as teams of motors in vitro using biophysical methods such as optical trapping. These studies showed that myosin force-generating behavior can differ greatly when moving from the single-molecule level in a three-bead arrangement to groups of motors working together on a rigid bead or coverslip surface in a gliding arrangement. However, these assay constructions do not permit …