Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons™

Open Access. Powered by Scholars. Published by Universities.®

Master's Theses

Discipline
Institution
Keyword
Publication Year

Articles 1 - 30 of 304

Full-Text Articles in Biomedical Engineering and Bioengineering

Multidimensional Determinants Of Gait, Balance, And Softball Performance In Female Youth: Biomechanics, Resource Access, And Psychosocial Factors, Allie G. Mcauliffe Aug 2026

Multidimensional Determinants Of Gait, Balance, And Softball Performance In Female Youth: Biomechanics, Resource Access, And Psychosocial Factors, Allie G. Mcauliffe

Master's Theses

Movement quality is a fundamental indicator of healthy childhood development and supports physical, emotional, psychosocial, and cognitive well-being. Movement quality is influenced by multiple biomechanical, environmental, and psychosocial factors, yet the relationships among them remain poorly understood in underrepresented populations such as female youth, particularly in softball. Previous studies have largely examined biomechanics, resource access, and psychosocial experience independently, and few have investigated how these factors interact in female youth softball players. To address this gap, this study compared gait and balance characteristics between softball (N = 34) and non-softball (N = 7) female youth, examined associations between resource access, …


Development Of A Video-Based Tool To Measure Motor Asymmetry In Infants At Risk For Hemiparesis, Roha Ali Jun 2026

Development Of A Video-Based Tool To Measure Motor Asymmetry In Infants At Risk For Hemiparesis, Roha Ali

Master's Theses

Congenital hemiparesis is a unilateral motor impairment stemming from brain injury in utero or early postnatally. Hemiparesis can be difficult to detect in early infancy with current clinical tools. Yet, early identification of motor asymmetry could play a key role in the design of effective early intervention and rehabilitation strategies. This thesis presents the development and validation of a video-based tool designed to extract infant limb movement data using DeepLabCut’s (DLC) machine learning network. The pipeline was developed using videos of typically developing (TD) infants and infants with Asymmetric Perinatal Brain Injury (APBI), all at or under 3 months corrected …


A Security Framework For Pacemaker Lead Failure: Anomaly Detection System And Failsafe Policy Considerations, Ethan Wagner Jun 2026

A Security Framework For Pacemaker Lead Failure: Anomaly Detection System And Failsafe Policy Considerations, Ethan Wagner

Master's Theses

Embedded system security in implantable medical devices (IMDs) remains an underexplored challenge due to the unique constraints of these systems. Specifically, pacemakers are optimized for ultra-low power consumption to maximize device lifespan, are highly resource constrained, and demand reliable and correct operation to prevent severe health consequences. These systems rely on sensing electrodes, called leads, to detect cardiac activity and stimulate the patient’s heart when appropriate. Therefore, pacemaker lead integrity is a critical issue, as malfunction or compromise can result in device failure jeopardizing patient safety.

The security framework presented in this thesis integrates several works to proactively detect and …


Evaluation Of Alternative Solvents For Electrospinning Occluded Scaffolds To Model Intracranial Atherosclerotic Disease In Blood Vessel Mimics, Olivia D. Rankin Jun 2026

Evaluation Of Alternative Solvents For Electrospinning Occluded Scaffolds To Model Intracranial Atherosclerotic Disease In Blood Vessel Mimics, Olivia D. Rankin

Master's Theses

Intracranial atherosclerotic disease (ICAD) is characterized by a buildup of fatty plaque within the walls of arteries supplying the brain, resulting in vessel narrowing, restricted blood flow, and increased risk of ischemic stroke. While various treatments exist for ICAD, most are accompanied by high recurrent stroke rates and other adverse events, highlighting the need for further investigation and models for pre-clinical testing. Tissue engineered Blood Vessel Mimics (BVMs), consisting of a polymer scaffold sodded with human vascular cells, serve as physiologically relevant in vitro models for vascular device testing. This thesis focused on the application of alternative solvents to a …


Electrically Evoked Emg Decomposition Using The Perturbative Generalized Series Expansion, William R. Walker Jun 2026

Electrically Evoked Emg Decomposition Using The Perturbative Generalized Series Expansion, William R. Walker

Master's Theses

Electrically evoked electromyography records the muscle's response to nerve stimulation and has been used for clinical assessment of neuromuscular function, as well as treatments such as functional electrical stimulation or stroke rehabilitation. In every muscular contraction, an electrical signal is generated. These signals come from the summation of simultaneously recruited motor units, enabling decomposition techniques to reveal information about motor unit recruitment.  By improving the ability to decompose and analyze these signals, clinical treatments involving neuromuscular electrical stimulation can be optimized and better understood. Much of the research on EMG analysis focuses on voluntary EMG, leaving a gap in the …


Computational Modeling To Evaluate Bipolar Flexible Electrode Designs For Use In Sciatic Nerve Stimulation, Krystyna S. Allman Jun 2026

Computational Modeling To Evaluate Bipolar Flexible Electrode Designs For Use In Sciatic Nerve Stimulation, Krystyna S. Allman

Master's Theses

Peripheral nerve stimulation is clinically used to manage pain, rehabilitate motor function, and promote nerve regeneration. The sciatic nerve is often studied for stimulation due to its accessibility and clinical relevance. A conventional nerve cuff electrode is the least invasive method for nerve stimulation, but the mismatch of mechanical properties of the electrode with the nerve tissue can cause damage to the nerve and the electrode itself. This study investigated a novel bipolar, gold nanowire-based cuff electrode design and its ability to selectively activate fibers in the rat sciatic nerve at varying interelectrode spacings. In COMSOL, A finite element model …


The Effects Of Carbon-Fiber Plates And Peba-Based Midsole Foam In Running Shoes On Lower-Limb Joint Kinetics And Kinematics In Recreational Female Runners, Jordan M. Allen Jun 2026

The Effects Of Carbon-Fiber Plates And Peba-Based Midsole Foam In Running Shoes On Lower-Limb Joint Kinetics And Kinematics In Recreational Female Runners, Jordan M. Allen

Master's Theses

The recent increase in long-distance running participation and the rapid advancement in footwear technology have created a need for research on injury prevention in this growing population of recreational runners. When “super shoes” were first introduced to the running scene, they caught the attention of runners worldwide with the rapid improvement in marathon performance [1]. Today, every major running brand offers its own version of a super shoe, each incorporating a carbon-fiber plate and PEBA-based midsole foam. While previous studies have shown the performance benefits of these shoes, a gap remains in the literature regarding how they impact knee, hip, …


Evaluation Of Laser Doppler Flowmetry And Transillumination Laser Speckle Contrast Imaging To Measure Blood Flow Change In Ischemia Mouse Hindlimb Models, Simon Park Jun 2026

Evaluation Of Laser Doppler Flowmetry And Transillumination Laser Speckle Contrast Imaging To Measure Blood Flow Change In Ischemia Mouse Hindlimb Models, Simon Park

Master's Theses

Peripheral Artery Disease (PAD), caused by plaque buildup and narrowing of the arteries, reduces blood flow to the extremities. Promoting collateral arteriogenesis can help redirect blood flow. However, simple growth of collaterals may not be enough to reverse PAD. Instead, the ability for the collaterals to vasodilate and control blood flow is important, meaning assessing collateral function is important for the arteriogenesis assesment. Although microscopy techniques can measure vasodilation, contrast limitations in larger vessels such as collaterals make blood flow measurements difficult. Techniques such as ultrasound or magnetic resonance imaging (MRI) can measure blood flow but have limitations with cost …


Characteristic Stress And Strain Optimization Of Cardiovascular Catheters With Laser-Cut Hypotubes Using Finite Element Analysis, Kyle E. Hirth Jun 2026

Characteristic Stress And Strain Optimization Of Cardiovascular Catheters With Laser-Cut Hypotubes Using Finite Element Analysis, Kyle E. Hirth

Master's Theses

Cardiovascular catheter systems rely on laser-cut hypotubes to balance flexibility and structural integrity required for minimally invasive surgical procedures.  Optimizing these mechanical characteristics remains a significant challenge.  This study aims to investigate the influence of key laser-cut geometric parameters on the mechanical performance of hypotubes through finite element analysis.

Commercially representative laser-cut hypotubes were modeled and a finite element model was developed.   Geometric design parameters were varied across a design space consisting of pitch values ranging from 0.006 in. to 0.018 in. and cuts per revolution (CPR) ranging from 2.5 – 4.5.  For each pitch and CPR combination, loading stiffness …


Design And Validation Of A Wearable Respiratory Protection System For Wildland Firefighters, Oliver Pilon Mar 2026

Design And Validation Of A Wearable Respiratory Protection System For Wildland Firefighters, Oliver Pilon

Master's Theses

Wildland and Wildland–Urban Interface firefighters are routinely exposed to hazardous smoke with fine particulate matter, carbon monoxide, volatile organic compounds, and other toxic combustion products. Existing protective gear has significant limitations and shortcomings for these conditions. Respirators with tight-fitting facepieces make it difficult to breathe and speak. On the other hand, self-contained breathing apparatuses are too heavy, have a limited duration of use, and do not work well with long wildland fire scenes, while smaller protective equipment like N-95’s and gaiters provide very little protection. These constraints contribute to low adoption rates and prolonged occupational exposure.

This thesis presents the …


Fully Integrated Slippage Detection System For Lower Limb Amputees, Christopher E. Miglio Dec 2025

Fully Integrated Slippage Detection System For Lower Limb Amputees, Christopher E. Miglio

Master's Theses

Lower limb amputees face significant challenges in maintaining a proper prosthetic fit, as improper fit can lead to slippage at the limb-socket interface, resulting in discomfort, pressure sores, and long-term musculoskeletal complications. To address this issue, a fully integrated slippage detection system was developed to monitor an amputee’s daily activities and slippage occurrences to understand their prosthetic fit over time. The system consists of a prosthetic sock embedded with Interlink 406 flexible piezoresistive force-sensing resistors (FSRs). The sock, worn directly on the residual limb, continuously measures pressure at the limb-socket interface. Sensor data from six FSRs is sampled at approximately …


A Novel Microfluidic Device For Preclinical Testing Of Chemotherapeutics, Kaija Saleh Ogan Dec 2025

A Novel Microfluidic Device For Preclinical Testing Of Chemotherapeutics, Kaija Saleh Ogan

Master's Theses

This work demonstrates the feasibility of a novel microfluidic tumor model that reproduces physiologically relevant nutrient gradients and endothelium–tumor interactions, validating its potential as a preclinical test platform. Finite element simulations of glutamine diffusion and fluid dynamics aligned with experimental tracer studies, and co-cultures supported directed endothelial migration toward tumor spheroids, confirming the device’s ability to mimic in vivo–like behavior.

Current preclinical models often fail to capture the complexity of the tumor microenvironment (TME), limiting their predictive value for therapeutic testing. Nutrient availability and angiogenic signaling are critical drivers of tumor progression, yet they are poorly represented in traditional …


Muscle Impulse Transducer: Research, Pre-Pilot Experiments, And The Design Of A Pilot Study For Quadriplegic Spinal Cord Injured Subjects For The Development Of A Novel Device, Marta Oreglia Dec 2025

Muscle Impulse Transducer: Research, Pre-Pilot Experiments, And The Design Of A Pilot Study For Quadriplegic Spinal Cord Injured Subjects For The Development Of A Novel Device, Marta Oreglia

Master's Theses

Paralysis due to spinal cord injury is a challenging condition that affects millions of people around the world. The Muscle Impulse Transducer (MIT) is a novel, wearable device that can be used to improve grip strength in the hand by using functional muscle impulses as a trigger for stimulus delivery to weakened or paralyzed nerves, to induce contraction of a paralyzed or paretic muscle. The MIT is still in development, with proof of concept [1], and functional prototypes [2] achieved. In this thesis, research was conducted on the best methods for functional electrical stimulation, EMG data collection, and nerve stimulus …


Using Noninvasive Calibrated Cuff Plethysmography To Observe The Effects Of Lifestyle Habits On Arterial Compliance, Joshua M. Whitaker Dec 2025

Using Noninvasive Calibrated Cuff Plethysmography To Observe The Effects Of Lifestyle Habits On Arterial Compliance, Joshua M. Whitaker

Master's Theses

Cardiovascular disease remains as a leading cause of death for both sexes and across all racial backgrounds. Continuing to research causes, early predictors, and preventative actions are paramount to ensuring that cardiovascular disease starts to decrease in its activity. Endothelial dysfunction is the earliest known predictor of cardiovascular disease, therefore investigating early detection methods of endothelial dysfunction can improve health outcomes. This study revolves around a non-invasive calibrated cuff device that uses the principles of segmental plethysmography and oscilliometry to measure arterial compliance of baseline and induced hyperemic conditions in human subjects to determine how well arteries vasodilate in response …


Exploring The Effectiveness Of Virtual Reality Learning Through Use Of Visual Eye-Tracking Analytics (Veta) And Biological Measurements, Mckinley Anne Sherman Nov 2025

Exploring The Effectiveness Of Virtual Reality Learning Through Use Of Visual Eye-Tracking Analytics (Veta) And Biological Measurements, Mckinley Anne Sherman

Master's Theses

Virtual Reality (VR) offers an immersive and interactive platform for experiential learning. The purpose of this thesis was to evaluate the relationship between physiological responses and cognitive workload within a VR learning environment and to explore VR as an effective instructional tool. This research compared participant engagement, stress, and learning performance within a 6th-grade science module developed in VR by incorporating biometric data collected via Polar H10 heart rate monitor and Varjo Areo VR headset eye-tracking. Thirty-three participants completed a pre-lesson demographic survey, post-lesson survey, VR sickness questionnaire, and the NASA Task Load Index (NASA-TLX). While completing the lesson, the …


A Convolutional Neural Network Approach To Breast Cancer Tumor Boundary Detection, James Leah Matlosz Nov 2025

A Convolutional Neural Network Approach To Breast Cancer Tumor Boundary Detection, James Leah Matlosz

Master's Theses

Breast cancer is the second most common form of cancer and often goes undetected in its initial stages due to its subtle symptoms. As the tumors grow, they become more difficult to surgically remove with clean borders. To minimize the chance of recurrence, a 2D convolutional neural network is developed in this work for delineating tumor boundaries. Specifically, the U-shaped network model is trained, validated, and tested with longitudinal MRI scans of patients diagnosed with breast cancer and undergoing neoadjuvant therapy. For training, image masks were generated as ground truths using signal enhancement ratio segmentation, thresholding, and contour detection. The …


Development Of A Colorectal Cancer Spheroid Model To Improve The Accuracy Of Preclinical Drug Testing, Jillian Trilevsky Oct 2025

Development Of A Colorectal Cancer Spheroid Model To Improve The Accuracy Of Preclinical Drug Testing, Jillian Trilevsky

Master's Theses

Colorectal cancer is the second leading cause of cancer related deaths worldwide. It currently affects millions of people across the globe and is only expected to increase in impact over the coming years. The most common treatment for metastatic colon cancer is chemotherapy, however, the development of chemotherapeutic drugs is a long and expensive process. A large portion of this development process is spent in preclinical drug testing. However, the models used often lack enough physiological relevance to guarantee the drug’s success in a clinical trial. Due to this gap in testing, researchers seek to develop a more physiologically relevant …


Measurements Of Spinal Posture During Common Strawberry Picking Positions Using Inertial Measurement Units, Madeline E. Everson Aug 2025

Measurements Of Spinal Posture During Common Strawberry Picking Positions Using Inertial Measurement Units, Madeline E. Everson

Master's Theses

Physically demanding professions, such as agriculture, put people at an increased

risk for experiencing back pain. This is due to the awkward and harmful postures sustained

throughout their workday. While studies have been done demonstrating that back pain is

prevalent amongst this community, most do not collect motion capture (MoCap) data,

leaving the specifics of the kinematics, such as the amount of time spent in harmful

postures, unknown. Unfortunately, MoCap data is typically limited to that of a lab or

facility where the cameras are housed. Therefore, this study aimed to mitigate the

inaccessibility of traditional MoCap by validating that …


Mechanoregulation Of Osteogenesis And Adipogenesis Of Human Mesenchymal Stem Cells, Justin Caron Aug 2025

Mechanoregulation Of Osteogenesis And Adipogenesis Of Human Mesenchymal Stem Cells, Justin Caron

Master's Theses

Bone-related diseases (e.g., osteoporosis) are primarily treated with pharmacologic therapies that often exhibit limited efficacy and substantial side effects. Currently, bone marrow derived mesenchymal stem cells (MSCs) have become one of most important cell options in bone regeneration due to readily available sources, strong proliferation abilities, weak immune rejection responses, and strong osteogenic differentiation potential. While identifying the most effective approach to enhance osteogenic differentiation of MSCs for bone regeneration is challenging, understanding the regulatory mechanisms is crucial for improving therapeutic efficacy. Recent research has focused on developing strategies to enhance osteogenesis, which involve biophysical and biochemical stimulation. Mechanical and …


Novel Electrospinning Techniques For Fabricating Scaffolds To Model Intracranial Atherosclerotic Disease In Tissue Engineered Blood Vessel Mimics, Isaac "Squeaky" Buentipo Jun 2025

Novel Electrospinning Techniques For Fabricating Scaffolds To Model Intracranial Atherosclerotic Disease In Tissue Engineered Blood Vessel Mimics, Isaac "Squeaky" Buentipo

Master's Theses

Novel Electrospinning Techniques for Fabricating Scaffolds to Model Intracranial

Atherosclerotic Disease in Tissue Engineered Blood Vessel Mimics

Isaac “Squeaky” Buentipo

Dr. Kristen Cardinal’s Tissue Engineering Lab at California Polytechnic State University specializes in fabricating customized vascular models, known as Blood Vessel Mimics (BVMs), for medical device testing. BVMs are simplified in vitro vascular models designed to bridge the gap between bench testing and in vivo evaluation of intravascular medical devices. BVMs are produced by combining a polymer scaffold with human vascular cells. Through novel scaffold fabrication techniques, such as silicone injection molding, silicone dip casting and electrospinning, the capabilities of …


Evaluation Of Antibiotic Testing Protocols For Biofilm-Forming Escherichia Coli In A Microfluidic Platform, Caleb R. Telander Jun 2025

Evaluation Of Antibiotic Testing Protocols For Biofilm-Forming Escherichia Coli In A Microfluidic Platform, Caleb R. Telander

Master's Theses

Catheter-associated urinary tract infections remain an ongoing clinical problem due to biofilm persistence and antibiotic resistance. Standard antibiotic susceptibility testing cannot accurately reproduce flow conditions and the spatial complexity of the in vivoenvironment and is thus questionable in relevance to device-related infections. This study examines a microfluidic device designed to simulate physiologically relevant wall shear stress and antibiotic gradients in Escherichia coli biofilms. The polydimethylsiloxane-based system integrates a 16-well culture chamber with a gradient generator. Biofilm growth was observed using fluorescence microscopy of green fluorescent protein-labeled bacteria. Simulations performed using COMSOL Multiphysics software estimated the appropriate range of wall …


Efficacy Of Monophasic And Biphasic Pulsed Field Ablation Waveforms: A Model Study, Natalia Dekock Jun 2025

Efficacy Of Monophasic And Biphasic Pulsed Field Ablation Waveforms: A Model Study, Natalia Dekock

Master's Theses

Cardiac arrhythmias are conditions where the heart’s normal sinus rhythm is interrupted by accelerated or premature rhythms. The most prevalent of these rhythms is atrial fibrillation (AF), where disorganized impulses cause the atria to quiver and pump blood inefficiently. As of 2025, AF affects over 10 million people. Aside from invasive surgical treatments, antiarrhythmic drugs, or one time cardioversions, atrial fibrillation is treated with catheter ablation. The longstanding ablation solutions for AF have been the cryoballoon or radiofrequency catheter ablation. However, limitations for these two ablation modalities are due to the nature of cell destruction; both thermal methods pose a …


Effect Of Foot Strike Pattern On Joint Kinetics On A Downhill Slope, Evan Manley Jun 2025

Effect Of Foot Strike Pattern On Joint Kinetics On A Downhill Slope, Evan Manley

Master's Theses

With recent increases in participation in outdoor running events, there is a need for research in downhill gait biomechanics. One change that could impact joint loading is foot strike pattern. Foot strike patterns have been categorized into rearfoot-strike (RFS), midfoot-strike (MFS), and forefoot-strike (FFS) [1]. While 75-99% of distance runners naturally RFS on level surfaces, they tend to move towards FFS when it is necessary to reduce vertical loading conditions at the knee [1]. The purpose of this study was to examine differences in peak vertical knee and ankle forces, knee moment, and ankle power, as well as cumulative force …


Opensim Analysis Of The Aymara Indigenous People Performing Ancestral Tasks: Exploring Trends Of Muscle Activity With Tiwanaku Skeletal Indicators, Noah M. Taylor Jun 2025

Opensim Analysis Of The Aymara Indigenous People Performing Ancestral Tasks: Exploring Trends Of Muscle Activity With Tiwanaku Skeletal Indicators, Noah M. Taylor

Master's Theses

The Tiwanaku civilization (AD 500-1100) of the Andean highlands exhibited occupational specialization in communities, with archeological evidence suggesting the existence of labor- and residential-communities, or “taskscapes”, based on an individual’s livelihood. Prior bioarcheological studies have examined Tiwanaku skeletal remains for musculoskeletal stress markers, osteoarthritis, and cross-sectional geometry to infer activity patterns. Their descendants, the Aymara Indigenous people, currently live in the same highlands and until recently lived a lifestyle like their ancestors. Over the past 20 years, the global quinoa demand has risen, thrusting the Aymara into globalization and moving them away from the traditional tasks previously performed. This study …


Acoustic And Hemodynamic Analysis Of Phantoms: Roughness And Flow Dynamics, Ethan Erik Olof Sundberg Jun 2025

Acoustic And Hemodynamic Analysis Of Phantoms: Roughness And Flow Dynamics, Ethan Erik Olof Sundberg

Master's Theses

The purpose of this study was to determine whether different vascular phantoms, with and without a surrogate arm, could serve as effective analogs to the human brachial artery for assessing endothelial dysfunction, an early indicator of cardiovascular disease, particularly atherosclerosis. Atherosclerosis is characterized by plaque buildup and endothelial damage, which precede more severe clinical events and are often detectable through changes in vascular function. A 40” water tower was used to simulate diastolic pressure, enabling water flow through each phantom. Strain gauge pressure transducers were placed at both ends of the phantoms to measure pressure drop, while a microphone captured …


A Manufacturing Process For Interdigitated Microelectrodes On Glass Wafers, Wyatt W. Warfield Jun 2025

A Manufacturing Process For Interdigitated Microelectrodes On Glass Wafers, Wyatt W. Warfield

Master's Theses

This study presents work done to optimize the process parameters to produce interdigitated electrodes on a borosilicate wafer. Using designed experiments and statistical analysis, the error in pattern transfer was minimized using for key process steps including exposure time, develop time and post exposure bake duration. Similarly, statistical analysis was used with profilometry data to fine tune the develop times. Qualitative analysis was used to assess thin film deposition. The resulting process produced wafers with improved pattern transfer and adequate film adhesion


Optimizing Microfluidic Murine Fibroblast And Human Epidermal Keratinocyte Cell Culture In 70Μm Microwells, Christian Navarro Jun 2025

Optimizing Microfluidic Murine Fibroblast And Human Epidermal Keratinocyte Cell Culture In 70Μm Microwells, Christian Navarro

Master's Theses

Cell culture is an essential technique utilized in biotechnology and medicine to remove systemic influences to study cellular behavior and morphological development of individual cell lines. However, conventional cell culture is two-dimensional and static meaning it can’t easily mimic in vivo conditions such as multicellular cell to cell interactions, fluid perfusion, or 3D structures which might alter cellular behavior and morphology. Microfluidic cell culture allows for the incorporation of in vivo conditions such as perfusion and chemical gradients allowing for more physiologically accurate models. The goal of this study is to develop a protocol for testing a microfluidic chip designed …


Quantifying Harmful Trunk Postures: Inertial Sensor Analysis Of Trunk Angle To Support Low Back Pain Prevention, Elsa E. Bates Jun 2025

Quantifying Harmful Trunk Postures: Inertial Sensor Analysis Of Trunk Angle To Support Low Back Pain Prevention, Elsa E. Bates

Master's Theses

Low back pain is a highly prevalent condition worldwide, impacting up to 80% of individuals at least once in their lifetime. A critical gap in current prevention strategies is the lack of tools to accurately measure trunk posture and movement in real-world environments. Accurate identification of biomechanical risk requires information about movement intensity, duration, and frequency, yet traditional assessment methods rely on self-reporting or visual observation, which are time-consuming and prone to error. To address this gap, a wearable monitoring method, consisting of two Inertial Measurement Units, was designed to quantify risk exposure to the spine by measuring angular position …


Hands-Free Balance Protocol And Development Of An Iphone App For Self-Assessment, Jacob Matties Jun 2025

Hands-Free Balance Protocol And Development Of An Iphone App For Self-Assessment, Jacob Matties

Master's Theses

For many clinical populations, the measurement of balance is a critical task. Previous studies have agreed that smartphone IMUs provide a valid measure of balance that can be significantly correlated with force plate measurements and is sensitive enough to distinguish between various balance poses, but many balance assessment protocols require uncommon equipment or the use of hands during assessment. These limit accessibility of balance assessment. To eliminate the need for hands or any additional equipment, this study assessed the use of a smartphone recording the root mean square of 3D acceleration magnitude. The goal of the study was to determine …


Assessing Arterial Compliance: Utilizing A Surrogate Arm Bench Top Model For Oscillometric Blood Pressure Monitoring, Krystal Cardenas Mar 2025

Assessing Arterial Compliance: Utilizing A Surrogate Arm Bench Top Model For Oscillometric Blood Pressure Monitoring, Krystal Cardenas

Master's Theses

A study was conducted to evaluate the compliance of artificial artery systems utilizing an adaptation of the Yong-Geddes Surrogate Arm model, composed of a blood pressure cuff, artificial artery, pressure transducers, and flow to replicate physiological conditions to validate oscillometric non-invasive blood pressure measurement methods. The experiment phases included tube, blood pressure cuff, and the surrogate arm compliance tests both in static and dynamic conditions. Tube compliance tests showed that larger diameters resulted in increased compliance, with Sample 1 (smaller inner diameter, ID) resulting in an average compliance of 0.0912 mL/mmHg, and Sample 2 (bigger ID) resulting in 0.1597 mL/mmHg. …