Predicting The Response Of Tendon-Driven Prosthetic Finger With Hyperelastic Joints,
2025
University of Nevada, Las Vegas
Predicting The Response Of Tendon-Driven Prosthetic Finger With Hyperelastic Joints, Lucas Gallup, Mohamed Trabia, Brendan O'Toole
Mechanical Engineering Faculty Research
Properly designed prosthetics hands can enhance the quality of life for those suffering from limb loss. Recently, 3D-printed prosthetic hands are becoming common. In these prostheses, fingers flex through the tendons that are activated by motion of the wrist. To provide spring action, thermoplastic polyurethane (TPU) hyperelastic joints are used to connect digits to each other as well as to the wrist. While these designs are common, no model for the relationship between tendon tension and joint flexion is available. This work has developed a quasi-static virtual work-based model to predict the relationship between tendon forces and the flexion of …
Sar Analog-To-Digital Converters For Point-Of-Care Biosensors: A Comparison,
2025
Effat University
Sar Analog-To-Digital Converters For Point-Of-Care Biosensors: A Comparison, Eithar Alammari, Joud Alamro, Sara Alashwali, Ghadah S. Alyami, Aziza I. Hussein
Effat Undergraduate Research Journal
The SAR ADC, recognized for its low power consumption, moderate resolution, and satisfactory processing speed, stands as an ideal choice for ultra-low power biomedical applications. Recent efforts have been concentrated on enhancing the power efficiency of the SAR ADC sub-components through intricate refinements and innovative techniques. These efforts aim to minimize energy consumption without compromising the ADC's performance. Therefore, this paper aims to thoroughly examine various implementation approaches for the main components of the SAR ADC, highlighting their individual strengths, weaknesses, and limitations within wireless biomedical applications.
Surgeon Ergonomics While Performing Total Knee Arthroplasty,
2025
University of Denver
Surgeon Ergonomics While Performing Total Knee Arthroplasty, Cameron Dahman
Electronic Theses and Dissertations
One of the most prevalent hazards to orthopedic surgeons are musculoskeletal disorders with 97% of arthroplasty surgeons reporting procedural-related musculoskeletal pain and 66% of orthopedic surgeons reporting procedural-related musculoskeletal injury [1], [2], [3]. With the annual number of total knee arthroplasties (TKA) on the rise, orthopedic surgeons are taking on larger annual caseloads and retiring later in life [4], [5]. The goal of this study was to quantify postural demand for 11 discrete surgical steps of TKA to identify ergonomically unfavorable positions surgeons experience while operating. Four orthopedic surgeons performed TKA while their motions were recorded using marker-based motion capture. …
Influence Of Obesity On Knee Joint Mechanics: A Subject-Specific Musculoskeletal Modeling Approach,
2025
University of Denver
Influence Of Obesity On Knee Joint Mechanics: A Subject-Specific Musculoskeletal Modeling Approach, Ryan C. Knowles
Electronic Theses and Dissertations
Obesity has been consistently linked to knee osteoarthritis (KOA), a debilitating joint disease. While prior work has shown that obese individuals often walk with altered biomechanics compared to normal-weight (NW) individuals, which may accelerate KOA progression, less is known about how these mechanics affect load distribution between the medial and lateral tibiofemoral (TF) compartments, particularly during higher-demand activities. This study developed subject-specific musculoskeletal models of five obese and five NW individuals, incorporating CT-based bone measurements and individualized joint contact points. Simulations were driven by six degree-of-freedom (6DOF) kinematics obtained from high-speed stereo radiography (HSSR) to predict TF loading and associated …
Investigation Of A Divergent Triangle Construct For Internal Fixation Of Vertical Femoral Neck Fractures Using Experimental And Finite Element Analysis Methods,
2025
Grand Valley State University
Investigation Of A Divergent Triangle Construct For Internal Fixation Of Vertical Femoral Neck Fractures Using Experimental And Finite Element Analysis Methods, Hannah Rainey
Masters Theses
Hip fractures are a significant public health issue as they are a commonly encountered problem and have a high rate of mortality. The fracture of the femoral neck is difficult to treat due to the geometry of the proximal femur and the weight-bearing capacity that the structure must comply with. Internal fixation of the femoral neck is often accomplished with three screws inserted along the axis of the femoral neck. The optimal configuration and number of these screws is not agreed upon in the literature. The purpose of this study was to conduct a pilot investigation on the biomechanical performance …
Ceramic Waste As Sustainable Material In Self-Compacting Concrete: Experimental Study And Ann Predictive Modeling,
2025
Faculty of Technology, Laboratory of Construction Engineering and Architecture (LGCA), University of Bejaia, 06000 Bejaia, Algeria
Ceramic Waste As Sustainable Material In Self-Compacting Concrete: Experimental Study And Ann Predictive Modeling, Abderrezak Bouziane, Houssam Slimanou, Mohamed Amin Bouzidi, Nedjima Bouzidi
Journal of Sustainable Construction Materials and Technologies
Recycling of ceramic waste in the construction sector is a promising option for reducing the environmental impacts of the concrete industry. The main objective of this study is the elaboration of a solid predictive model for ceramic waste based self-compacting (SCC) concrete properties, using artificial neural networks (ANN). This further, reduces its environmental impact without compromising satisfactory performance. An experimental approach was adopted with different substitution ratios: 0 to 30 wt% and particle sizes ranging from 3-8 mm and 8-15 mm. Tested properties of modified SCC as compressive strength at 7 and 28 days (fc7, fc28), spread (L), sieve stability …
Comparative Study On The Performance Of Ggbs, Uggbs, And Rha-Incorporated Cement Mortar Mixes,
2025
Research Scholar, School of Construction, NICMAR University, Pune-411025, Maharashtra, India
Comparative Study On The Performance Of Ggbs, Uggbs, And Rha-Incorporated Cement Mortar Mixes, Devansh Goel, Sudarshan D. Kore
Journal of Sustainable Construction Materials and Technologies
The environmental footprint of cement production has accelerated the pursuit of sustainable alternatives in the construction industry. Supplementary cementitious materials (SCMs), particularly those derived from industrial and agricultural waste, offer a promising approach to reducing cement consumption while maintaining performance. This study evaluates the fresh and mechanical behavior of binary, ternary, and quaternary cementitious mortar blends incorporating ground granulated blast-furnace slag (GGBS), ultrafine GGBS (UGGBS), and rice husk ash (RHA) as partial replacements for cement. A total of 32 mortar mixes were designed with water-to-binder (w/b) ratios ranging from 0.3 to 0.5 and varied replacement levels of RHA (0-20%), GGBS …
Correlations Between Hemodynamics And Radiomic Features In Thrombosed Intracranial Aneurysms,
2025
Michigan Technological University
Correlations Between Hemodynamics And Radiomic Features In Thrombosed Intracranial Aneurysms, Zonghan Lyu, Andres Gudino, Navami Shenoy, Carlos Dier, Elena Sagues, Jingfeng Jiang, Edgar A. Samaniego
Michigan Tech Publications
Purpose: Evaluating intracranial aneurysm (IA) rupture risk is essential for guiding management. Although intrasaccular thrombosis (IST) is less common, it can contribute to aneurysm growth, mass effect, and rupture. Aneurysm wall enhancement (AWE) on high-resolution MRI (HR-MRI) offers valuable insight into IST and IA progression. Using radiomics, we extracted spatial information of the aneurysm wall to characterize AWE. This study aimed to explore correlations between radiomics-based AWE profiles and gross hemodynamic parameters, integrating imaging and flow dynamics to better understand IST. Methods: Radiomic analysis was conducted on a cohort of 3T HR-MRI scans from IA with IST. Three-dimensional vascular reconstructions …
Palpation Characteristics Of An Instrumented Virtual Cricothyroidotomy Simulator,
2025
Sabanci University
Palpation Characteristics Of An Instrumented Virtual Cricothyroidotomy Simulator, Melih Turkseven, Trudi Di Qi, Ganesh Sankaranarayanan, Suvranu De
Engineering Faculty Articles and Research
Cricothyroidotomy (CCT) is a critical, life-saving procedure requiring the identification of key neck landmarks through palpation. Interactive virtual simulation offers a promising, cost-effective approach to CCT training with high visual realism. However, developing the palpation skills necessary for CCT requires a haptic interface with tactile sensitivity comparable to human fingers. Such interfaces are often represented by plastic partial mannequins, which require further adaptation to integrate into virtual environments. This study introduces an instrumented physical palpation interface for CCT, integrated into a virtual surgical simulator, and tested on 10 surgeons who practiced the procedure over a training period. Data on haptic …
Impact Analysis On Silicone Breast Implants Using In Vitro Experiments And Finite Element Analysis,
2025
Grand Valley State University
Impact Analysis On Silicone Breast Implants Using In Vitro Experiments And Finite Element Analysis, Brenna Marie Tiernan
Masters Theses
Silicone breast implants are commonly used in breast augmentation and reconstruction procedures. Mentor introduced two newer models of silicone gel-filled implants, the MemoryGelTM Xtra and MemoryGelTM Boost, designed to increase the gel fill and projection of the implants while reducing wrinkling and rippling of the shell. Modifications to the shape and fill of these implants may result in different mechanical responses under compressive or impact loading conditions. To investigate whether these structural differences influence implant behavior, in vitro drop testing and finite element analysis (FEA) simulations were conducted, focusing on impact forces, internal stresses, and deformation patterns experienced …
Facile Fabrication Of Protein-Polysaccharide Conjugate Multifilament Nerve Guidance Conduit For Peripheral Nerve Regeneration,
2025
SASTRA Deemed to be University
Facile Fabrication Of Protein-Polysaccharide Conjugate Multifilament Nerve Guidance Conduit For Peripheral Nerve Regeneration, Preethy Amruthavarshini R
Theses and Dissertations
Long segmental defects in peripheral nerves impair sensory and motor function by disrupting neural impulse transmission. End-to-end autologous grafting with proper fascicular complementation has demonstrated functional recovery per the Medical Research Council Classification (MRCC). However, obtaining donor nerve tissue exceeding 30 mm remains a significant challenge. Artificial hollow conduits serve as an alternative but are limited to defects smaller than 30 mm due to inadequate innervation across the lumen.
Multichannel nerve guidance conduits (mNGCs) have emerged as a promising solution by enhancing fascicular complementation similar to autografts. This study presents a two-step approach for fabricating nerve conduits with precise fascicular …
Functional Biopolymers Applied To Sustainable Technologies In The Environment And Healthcare,
2025
University of Nevada, Las Vegas
Functional Biopolymers Applied To Sustainable Technologies In The Environment And Healthcare, Fengjie He
UNLV Theses, Dissertations, Professional Papers, and Capstones
Biodegradable polymeric materials (biopolymers) are naturally derived materials known for their excellent biocompatibility, biodegradability, sustainability, and versatile chemical functionality. They have attracted increasing attention in various applications as alternative to synthetic materials ranging from food packaging to tissue engineering. Meanwhile, with intrinsic advantages, biopolymers have also emerged as promising materials in addressing contemporary challenges in both biomedical and environmental fields. Motivated by the significant potential of biopolymers and the growing need for sustainable materials, my research focuses on the design and engineering of biodegradable polymers with novel modification methods and application directions. In this work, two representative biopolymers are selected: …
Validity Of Body Composition Estimates In Women Assessed By A Multifrequency Bioelectrical Impedance Device,
2025
Kennesaw State University
Validity Of Body Composition Estimates In Women Assessed By A Multifrequency Bioelectrical Impedance Device, Mitchell Evan Zaplatosch, Juliana F. Meireles, Janeen S. Amason, Sadaf Dabeer, Brian M. Kliszczewicz, Gerald Mangine, Valene G. Barry, Barbara A. Gower, Katherine H. Ingram
Faculty Articles
Background: Multifrequency bioelectrical impedance devices such as the InBody 770 (IB770) offer faster measurements and lower costs compared with other body composition assessments. This study validated measures from IB770 against the deuterium oxide dilution technique (D2O) and DXA and compared a four-compartment (4C) model using total body water (TBW) derived from IB770 compared with D2O. Methods: A total of 55 adult females (mean ± SD, age: 21.1 ± 2.6 years) completed IB770 and DXA scans and the D2O protocol. Lin’s concordance correlation coefficients (CCCs), Bland–Altman analyses, and other equivalence tests evaluated agreement between IB770 and the criterion for measures of …
Effect Of Arm Movement On Lower Body Muscle Contributions To Standing Long Jump Performance,
2025
Grand Valley State University
Effect Of Arm Movement On Lower Body Muscle Contributions To Standing Long Jump Performance, Abigail Douglas
Masters Theses
Previous jumping studies have proven that jumping with arm motion enhances performance compared to jumping without arm motion. The purpose of this study was to investigate the effect of arm motion on the muscle contributions of the lower extremities during the standing long jump using muscle-actuated modeling informed by experimental data. Specifically investigating how arm motion enhances performance at the muscle level and how the muscle contributions of the lower extremities differ in jumps with and without arm motion. Three male and three female participants performed three jumps with arms and three jumps without arms. The longest jumps with and …
Advancing Single-Molecule Nanopore Sensing: From Protein Conformation And Metal Binding To Dna Transport Via Hybrid Nanostructures,
2025
Southern Methodist University
Advancing Single-Molecule Nanopore Sensing: From Protein Conformation And Metal Binding To Dna Transport Via Hybrid Nanostructures, Matthew J. Odonohue
Multidisciplinary Studies Theses and Dissertations
This dissertation presents the development and application of solid-state and hybrid nanopore platforms for single-molecule analysis of biomolecular interactions. First, a silicon nitride nanopore was employed to characterize the conformational states of the transferrin receptor (TfR), enabling discrimination between its monomeric and dimeric forms, as well as from its ligand, human serum transferrin (hSTf), despite their similar molecular weights. In a separate study, the same nanopore configuration was used to track the real-time binding of titanium ions to transferrin, demonstrating single-molecule sensitivity to metal-induced conformational changes. A hybrid microtubule–solid-state nanopore (MT–SSN) was then engineered, repurposing microtubules as electrostatically anchored conduits …
Novel Nanomaterials For Developing Bone Scaffolds And Tissue Regeneration,
2025
University of Arkansas, Fayetteville
Novel Nanomaterials For Developing Bone Scaffolds And Tissue Regeneration, Nazim Uddin Emon, Lu Zhang, Shelby Dawn Osborne, Mark Allen Lanoue, Yan Huang, Z. Ryan Tian
Cell and Molecular Biology Faculty Publications and Presentations
Nanotechnologies bring a rapid paradigm shift in hard and soft bone tissue regeneration (BTR) through unprecedented control over the nanoscale structures and chemistry of biocompatible materials to regenerate the intricate architecture and functional adaptability of bone. This review focuses on the transformative analyses and prospects of current and next-generation nanomaterials in designing bioactive bone scaffolds, emphasizing hierarchical architecture, mechanical resilience, and regenerative precision. Mainly, this review elucidated the innovative findings, new capabilities, unmet challenges, and possible future opportunities associated with biocompatible inorganic ceramics (e.g., phosphates, metallic oxides) and the United States Food and Drug Administration (USFDA) approved synthetic polymers, including …
Fourier-Feature Mlp Toolkit For Gpu-Accelerated Cardiac-Mri 4dcmr Strain Analysis,
2025
Purdue University
Fourier-Feature Mlp Toolkit For Gpu-Accelerated Cardiac-Mri 4dcmr Strain Analysis, Aarnav T. Sabale, Marco A. Prado, Craig J. Goergen
Discovery Undergraduate Interdisciplinary Research Internship
This paper explores the embedding of a Fourier-Feature—enhanced multiplayer perceptron(MLP-FEE) at the heart of a newly refactored python workflow for four-dimensional cardiac-MRI strain quantification demonstrating how a single, compact network can outperform traditional convolution and spline-based methods. The original code, capable of orientation normalization, displacement tracking, and finite-difference strain computation, has been translated and consolidated into pytorch. By injecting sinusoidal positional encodings at the network’s input layer supplied a rich set of high-frequency basis functions hence enabling multilayer MLP to resolve gradients that cubic splines and conventional CNNs typically blur or struggle with. Profiling on an Apple-silicon GPU shows interactive …
Utilizing Wearable Technology To Improve Pots Diagnostic Testing,
2025
Purdue University
Utilizing Wearable Technology To Improve Pots Diagnostic Testing, Monique Watson, Damen Wilson, Matthew Ward
Discovery Undergraduate Interdisciplinary Research Internship
Postural orthostatic tachycardia syndrome (POTS) is a form of dysautonomia characterized by a heart rate (HR) increase ≥30 beats/minute (bpm) within 10 minutes of standing from a supine position, without a significant blood pressure drop. POTS can diminish quality of life with symptoms including tachycardia, headaches, and fatigue. Despite established diagnostic criteria, POTS is often underrecognized or misdiagnosed due to its episodic nature. Symptoms may not consistently be present during diagnostic testing, leading to false negatives during in-office testing. Wearables offer a promising solution through continuous physiological monitoring. Individuals with hypermobile Ehler-Danlos Syndrome (hEDS), a population in which POTS is …
Volumetric Imaging Of Cellular Dynamics Using Light-Sheet Microscopy: From Subcellular Structures To Whole Organisms,
2025
University of New Mexico - Main Campus
Volumetric Imaging Of Cellular Dynamics Using Light-Sheet Microscopy: From Subcellular Structures To Whole Organisms, Md Nasful Huda Prince
Optical Science and Engineering ETDs
Advancing biomedical imaging requires platforms that combine high-resolution, speed, and stability across biological scales. This dissertation presents three innovations designed to address limitations of conventional light-sheet and oblique plane imaging. First, we introduce Reflected Inline Detection in Epi-Oblique Plane Microscopy (RIDE-OPM), a compact and drift-resistant system that eliminates a tertiary detection path while maintaining alignment flexibility, enabling robust long-term live imaging. Second, we present a high-speed Axially Swept Light-Sheet Microscopy (ASLM) platform for cleared tissues, using dual foci and synchronized sweeping to achieve isotropic sub-micron resolution at up to 40 frames-per-second, a fourfold improvement over standard ASLM. Integrated with a …
Measurements Of Spinal Posture During Common Strawberry Picking Positions Using Inertial Measurement Units,
2025
California Polytechnic State University, San Luis Obispo
Measurements Of Spinal Posture During Common Strawberry Picking Positions Using Inertial Measurement Units, Madeline E. Everson
Master's Theses
Physically demanding professions, such as agriculture, put people at an increased
risk for experiencing back pain. This is due to the awkward and harmful postures sustained
throughout their workday. While studies have been done demonstrating that back pain is
prevalent amongst this community, most do not collect motion capture (MoCap) data,
leaving the specifics of the kinematics, such as the amount of time spent in harmful
postures, unknown. Unfortunately, MoCap data is typically limited to that of a lab or
facility where the cameras are housed. Therefore, this study aimed to mitigate the
inaccessibility of traditional MoCap by validating that …