Exploring Rapid Solidification And Equal Channel Angular Pressing In The Fabrication Of Mg-Based Alloys For Medical Applications,
2021
Michigan Technological University
Exploring Rapid Solidification And Equal Channel Angular Pressing In The Fabrication Of Mg-Based Alloys For Medical Applications, Emily Tom
Dissertations, Master's Theses and Master's Reports
The development of magnesium bioresorbable implants has become increasingly popular due to the increased need for temporary implants and magnesium’s excellent biocompatibility and suitable elastic modulus. Even though magnesium is an excellent candidate, when alloyed with other metals magnesium’s corrosion rate becomes too rapid for bioresorbable medical applications. The investigation into novel processing techniques to control the formation of precipitates to improve mechanical strength and ductility as well as corrosion rates has become of interest. This work investigates the combination of two nonequilibrium processing techniques, rapid solidification (RS) and equal channel angular pressing (ECAP), and the effects it has on …
Electrospinning Of Formic Acid/Acetic Acid And Nylon-6 Solutions For Wearable Hydration Sensors,
2021
The University of Akron
Electrospinning Of Formic Acid/Acetic Acid And Nylon-6 Solutions For Wearable Hydration Sensors, Nichole Cooper, Jonathan Doak
Williams Honors College, Honors Research Projects
Students have been working on the development of wearable hydration sensors at the startup company RooSense. The goal of the company is to develop a lightweight wearable sensor that enables the user to know their hydration level, thus elevating their performance goals. To measure the hydration of the wearer, the sodium and other salt ions are collected from the user’s sweat as they exercise. This sweat is analyzed as it is collected to give the user an exact level of hydration, so they know how much fluids they need. The production of this ion sensor requires numerous steps and iteration …
Ecg Monitoring In Athletes,
2021
The University of Akron
Ecg Monitoring In Athletes, Jalal Jwayyed, Kelly Purgason, Joseph Linder, Annamarie Alfery, Silvia Furman
Williams Honors College, Honors Research Projects
Athletes and medical personnel need reliable methods to monitor vital signs and detect potentially life-threatening issues before they occur. Electrocardiograph (ECG) monitors are currently the best method of detecting heart-related health issues. Current ECG monitors worn by athletes are difficult to use and lack the ability to track ECGs in real time. Through research and interviews with various clinicians, further problems have been identified that include poor electrode adhesion, and a lack of compatibility with the equipment worn by athletes. Our team proposes to develop solutions that will improve performance and comfort associated with ECG monitors for athletic applications. This …
Improving The Monitoring Of Post-Operative Patient Mobility,
2021
University of Akron
Improving The Monitoring Of Post-Operative Patient Mobility, Owen T. Lacey, Alexandria Magyar-Averin, Elena Ewing, Samuel Elliott, Cameron Lazor
Williams Honors College, Honors Research Projects
Patient post-operative care is essential in attaining positive patient outcomes. To ensure proper blood circulation for recovery and healing is achieved, a patient's mobility is monitored. However, medical professionals aren't always available to continuously monitor patient progress. The clinical need for a medical device to monitor and quantify patient movement automatically is derived and addressed here. By designing a novel device and associated code, an engineering solution to this clinical need can be developed to monitor and improve patient post-operative outcomes in the absence of a medical professional. After completing research on the clinical need and gathering information from stakeholders …
Tubing/Lines Entanglement Reduction In Healthcare Settings,
2021
The University of Akron
Tubing/Lines Entanglement Reduction In Healthcare Settings, Abigail Kraft, Amy Beskitt, Grace Elerick, Zachery Steck
Williams Honors College, Honors Research Projects
Intravenous (IV) lines used in various healthcare settings pose a risk to patients and their caretakers. A few common risks include IV lines becoming torn out and coming into contact with open wounds. We propose to solve this problem by designing a device that prevents IV and wire entanglement without obstructing patient care. Our objectives in identifying a solution include increasing patient comfort, mobility, and ease of transfer. By solving this issue, other potential benefits include reducing time spent on non-essential tasks and reducing number of personnel needed to transport patients. We intend to validate our product with healthcare employees …
Activity Recognition Based On Thermopile Imaging Array Sensors,
2021
University of Northern Iowa
Activity Recognition Based On Thermopile Imaging Array Sensors, Qingshan Liang
Dissertations and Theses @ UNI
With aging population, the importance of caring for elderly people is getting more and more attention. In this paper, a low resolution thermopile array sensor is used to develop an activity recognition system for elderly people. The sensor is composed of a 32x32 thermopile array with the corresponding 33° × 33° field of view. The outputs of the sensor are sequential images in which each pixel contains a temperature value. According to the thermopile images, the activity recognition system first determines whether the target is within the tracking area; if the target is within the tracking area, the location of …
Assessing Heart Rate Using Consumer Technology Association Standards,
2021
Brigham Young University, Oahu
Assessing Heart Rate Using Consumer Technology Association Standards, Joel D. Reece, Jennifer A. Bunn, Minsoo Choi, James W. Navalta
Kinesiology and Nutrition Sciences Faculty Research
It is difficult for developers, researchers, and consumers to compare results among emerging wearable technology without using a uniform set of standards. This study evaluated the accuracy of commercially available wearable technology heart rate (HR) monitors using the Consumer Technology Association (CTA) standards. Participants (N = 23) simultaneously wore a Polar chest strap (criterion measure), Jabra Elite earbuds, Scosche Rhythm 24 armband, Apple Watch 4, and Garmin Forerunner 735 XT during sitting, activities of daily living, walking, jogging, running, and cycling, totaling 57 min of monitored activity. The Apple Watch mean bias was within ±1 bpm, and mean absolute percent …
Cycloidal-Drive Joint Design For Wearable Exoskeletons,
2020
New Jersey Institute of Technology
Cycloidal-Drive Joint Design For Wearable Exoskeletons, Abhi J. Rawal
Theses
This thesis's scope was to construct a highly back drivable and compact joint design that can be used for wearable exoskeletons specifically designed to assist with rehabilitation. A compact cycloidal gear transmission was designed to satisfy the compactness requirement while ensuring the minimum torque is required for backdriving the mechanism. The joint was designed based on the compact cycloidal drive specifications, and the backdrivability test was performed to measure the minimum torque required (1.20 Nm) to backdrive. The joint design incorporates various important features such as rotation lock feature to prevent hyperextension, a housing design that offers the benefit of …
Improve The Prototype Of Low-Cost Near-Infrared Diffuse Optical Imaging System,
2020
CUNY New York City College of Technology
Improve The Prototype Of Low-Cost Near-Infrared Diffuse Optical Imaging System, Chen Xu, Mohammed Z. Shakil
Publications and Research
Diffuse Optical Tomography (DOT) and Optical Spectroscopy using near-infrared (NIR) diffused light has demonstrated great potential for the initial diagnosis of tumors and in the assessment of tumor vasculature response to neoadjuvant chemotherapy. The aims of this project are 1) to test the different types of LEDs in the near-infrared range, and design the driving circuit, and test the modulation of LEDs at different frequencies; 2) to test the APDs as a detector, and build the receiver system and compare efficiency with pre-built systems. In this project, we are focusing on creating a low-cost infrared transmission system for tumor and …
Technology Aiding In Neonatal Lung Developmental Care,
2020
East Tennessee State University
Technology Aiding In Neonatal Lung Developmental Care, Megan Kirk
Undergraduate Honors Theses
In this paper, old as well as new technological findings to decrease premature infant mortality are reviewed. This paper discusses fetal development throughout pregnancy from conception to full-term status as well as fetal lung development specifically from conception until full-term status. Several ideas to rapidly develop and mature fetal lungs are discussed such as mothers ingesting artificial surfactant supplements, either independently or coupled with antenatal corticosteroids, as well as intra-amniotic instillation prior to 28 weeks gestational. Drawbacks regarding these two are mentioned as well such as the fetus’s lungs not being mature enough to use the artificial surfactant leading into …
Imparting 3d Representations To Artificial Intelligence For A Full Assessment Of Pressure Injuries.,
2020
University of Louisville
Imparting 3d Representations To Artificial Intelligence For A Full Assessment Of Pressure Injuries., Sofia Zahia
Electronic Theses and Dissertations
During recent decades, researches have shown great interest to machine learning techniques in order to extract meaningful information from the large amount of data being collected each day. Especially in the medical field, images play a significant role in the detection of several health issues. Hence, medical image analysis remarkably participates in the diagnosis process and it is considered a suitable environment to interact with the technology of intelligent systems. Deep Learning (DL) has recently captured the interest of researchers as it has proven to be efficient in detecting underlying features in the data and outperformed the classical machine learning …
Development Of A Pediatric Cardiac Assist Maglev Pump For Use With A Universal Driver System.,
2020
University of Louisville
Development Of A Pediatric Cardiac Assist Maglev Pump For Use With A Universal Driver System., Landon Heath Tompkins
Electronic Theses and Dissertations
Heart failure (HF) remains the leading cause of death, affecting 26 million adults worldwide and 6.5 million adults in the United States. Pediatric HF patients have been a historically underserved population with few options for mechanical circulatory support (MCS) therapy, a leading treatment as an alternative to heart transplantation. To address this clinical need, the Inspired Universal MagLev System is being developed; a low cost, universal magnetically levitated extracorporeal MCS system with interchangeable single-use pumps that will ultimately provide adult and pediatric patients ventricular and respiratory assist therapies. The Inspired Pediatric VAD is the first single-use pump application for this …
Multiphoton Microscopy And Deep Learning Neural Networks For The Automated Quantification Of In Vivo, Label-Free Optical Biomarkers Of Skin Wound Healing,
2020
University of Arkansas, Fayetteville
Multiphoton Microscopy And Deep Learning Neural Networks For The Automated Quantification Of In Vivo, Label-Free Optical Biomarkers Of Skin Wound Healing, Jake D. Jones
Graduate Theses and Dissertations
Non-healing ulcerative wounds that occur frequently in diseases such as diabetes are challenging to diagnose and treat due to numerous possible etiologies and the variable efficacy of wound care products. With advanced age, skin wound healing is often delayed, leaving elderly patients at high risk for developing these chronic injuries. As it is challenging to discriminate age-related delays from disease-related chronicity, there is a critical need to develop new quantitative biomarkers that are sensitive to wound status. Multiphoton microscopy (MPM) techniques are well-suited for 3D imaging of epithelia and are capable of non-invasively detecting metabolic cofactors (NADH and FAD) without …
A Novel Method To Commercialize Medical Devices Initially Developed At California Polytechnic State University San Luis Obispo,
2020
California Polytechnic State University, San Luis Obispo
A Novel Method To Commercialize Medical Devices Initially Developed At California Polytechnic State University San Luis Obispo, Christina Grigorian
Master's Theses
California Polytechnic State University, San Luis Obispo is a university that encourages students to approach learning hands-on. As such, there is cutting-edge technology being developed by students in all departments on campus. Being that the university possesses an outstanding biomedical engineering department, there are groundbreaking medical devices that students are creating at Cal Poly SLO. These are devices that can better the lives of individuals suffering from ailments or fulfill needs in the medical industry. Subsequently, it is vital that these devices make it out of campus laboratories and into the hands of consumers. In order to move a product …
Analysis Of Electroanatomic Mapping System Accuracy Using X-Ray Reconstruction Of Electrode Locations In A Porcine Animal Model,
2020
California Polytechnic State University, San Luis Obispo
Analysis Of Electroanatomic Mapping System Accuracy Using X-Ray Reconstruction Of Electrode Locations In A Porcine Animal Model, Hana Boudlali
Master's Theses
Fluoroscopy is considered the gold standard for locating catheters during cardiac electrophysiology (EP) procedures. However, fluoroscopy emits ionizing radiation which can lead to adverse health effects when exposed to in high doses (World Health Organization, 2016). Electroanatomic mapping (EAM) systems display the three-dimensional location of EP catheters and measure the local electrical activity of the heart. They can minimize a physician’s reliance on fluoroscopy and can help reduce radiation exposure during a case (Casella, 2011).
EAM systems are diagnostic medical devices that inform the placement of ablation therapy and must accurately locate catheters to be deemed safe. Test methods to …
Biomechanical Comparison Of The Validity Of Two Configurations Of Simulators For Body-Powered Hand Prostheses,
2020
Loyola Marymount University
Biomechanical Comparison Of The Validity Of Two Configurations Of Simulators For Body-Powered Hand Prostheses, Camille Bennett, Amanuel Matias, Brendan Smith, Jenevieve Roper, Stephen Estelle
Honors Thesis
Simulators are often used in prosthesis research to evaluate new devices or characterize aspects of prosthesis use, so as to recruit participants without amputations. Simulators, in general, must locate the prosthesis somewhere other than where the intact biological limb exists. In this study, we compared two configurations of simulators for hand prostheses to determine which leads to more natural elbow and shoulder kinematics, and in turn, which is the more valid simulator. One configuration located the prosthesis in-line with the forearm, beyond the biological hand; the other located it beside the hand. We measured the kinematics of 12 non-amputee participants …
Fuzzy Logic Based Control For Membrane Oxygenator In Blood Purification Process,
2020
Universiti Malaya
Fuzzy Logic Based Control For Membrane Oxygenator In Blood Purification Process, Hany Hazfiza Manap
Student Works (2020-2029)
Membrane oxygenator in Extracorporeal Life Support (ECLS) is commonly used as a main component in Cardiopulmonary Bypass (CPB), Extracorporeal Membrane Oxygenator (ECMO) and Extracorporeal Carbon Dioxide Removal (ECCO2R). In this study, the focus is on Carbon Dioxide (CO2) gas exchange process in membrane oxygenator, which the CO2 is automatically controlled by adjusting sweep gas flow rate that entering the membrane oxygenator in achieving the desired pCO2 required by the particular patients. This automatic control action is controlled by the implementation of three controllers, Proportional-IntegralDerivative (PID) that is tuned by Ziegler-Nichols continuous cycling method, Fuzzy Logic Controller (FLC) and Fuzzy-PID controllers. …
Calcium Sulfate-Containing Glass Polyalkenoate Cement For Revision Total Knee Arthroplasty Fixation,
2020
Missouri University of Science and technology
Calcium Sulfate-Containing Glass Polyalkenoate Cement For Revision Total Knee Arthroplasty Fixation, Leyla Hasandoost, Adel Alhalawani, Omar Rodriguez, Alireza Rahimnejad Yazdi, Paul Zalzal, Emil H. Schemitsch, Stephen D. Waldman, Marcello Papini, Mark R. Towler
Chemical and Biochemical Engineering Faculty Research & Creative Works
Poly (methyl methacrylate) (PMMA) bone cement is used as a minor void filler in revision total knee arthroplasty (rTKA). The application of PMMA is indicated only for peripheral bone defects with less than 5 mm depth and that cover less than 50% of the bone surface. Treating bone defects with PMMA results in complications as a result of volumetric shrinkage, bone necrosis, and aseptic loosening. These concerns have driven the development of alternative bone cements. We report here on novel modified glass polyalkenoate cements (mGPCs) containing 1, 5 and 15 wt% calcium sulfate (CaSO4) and how the modified …
An Exercise Device Used To Achieve Bone Formation Metrics For The Strengthening Of The Proximal Femur.,
2020
University of Louisville
An Exercise Device Used To Achieve Bone Formation Metrics For The Strengthening Of The Proximal Femur., Sean P. Coyle
Electronic Theses and Dissertations
Lateral falls often lead to hip fracture particularly in the elderly who have low bone mineral density. These fractures frequently lead to indirect mortality soon after injury. Normal use over the course over a lifetime leads to optimized adaptation of the bone in the proximal femur according to normal loading. A lateral fall generates non-normal, lateral loading at the proximal hip where the bone has not adapted to withstand such loading. The resulting fracture is generated by reversed strains on the bone tissue in the femoral neck in the hip in contrast to vertical, quotidian loading. Modern practices for preventing …
Analysis Of Glutathione Supplementation Effects On Female Metabolic Syndrome Condition Using Classification Techniques,
2020
Universiti Malaya
Analysis Of Glutathione Supplementation Effects On Female Metabolic Syndrome Condition Using Classification Techniques, Nur Rasyidah Hasan Basri
Student Works (2020-2029)
Lesser known to the public that main antioxidants in our body, Glutathione are also said to influence the metabolic syndrome (MS) condition. Oral supplementation consisting of glutathione precursors and vitamin C introduced in the study was to improve glutathione (GSH) status of the consumer and the main objective of this study is to investigate GSH effects on selected MS condition. Several known studies had proven that oral supplementation improved GSH level of consumer. However, there is no definite proof on how it’s affecting MS parameters. Also, there is less study carried out on the relationship between glutathione levels and metabolic …