Open Access. Powered by Scholars. Published by Universities.®

Dental Materials Commons™

Open Access. Powered by Scholars. Published by Universities.®

759 Full-Text Articles 1,361 Authors 370,951 Downloads 54 Institutions

All Articles in Dental Materials

Faceted Search

759 full-text articles. Page 8 of 29.

Surface Modifications Of Orthodontic Bone Screws - A Novel Approach, Sai kalyan Menta Dr, RAVI M. S 2024 AB Shetty Memorial Institute of Dental Sciences

Surface Modifications Of Orthodontic Bone Screws - A Novel Approach, Sai Kalyan Menta Dr, Ravi M. S

Annual Research Symposium

Anchorage control plays a key role in the correction of malocclusion. With the advent of orthodontic bone screws, attaining absolute anchorage control has become hassle free. They have the advantages of low cost, simple surgical placement, and ease of removal; therefore, they are convenient in the treatment of various malocclusions. Although the clinical stability of bone screws is exceptionally high, stability of the bone screws is compromised by factors such as microbial contamination and morphological defects. To overcome this, surface modifications are introduced to enhance the stability of the bone screws.


Alginate Dressings- Revisiting The Past, Oshine jha, Oshine Jha 2024 people's dental academy bhopal

Alginate Dressings- Revisiting The Past, Oshine Jha, Oshine Jha

Annual Research Symposium

Wound healing in simple terms is the healing of skin which involves various mechanisms. It is not dressings themselves that heal wounds, but the careful selection of appropriate dressings that provide the optimal wound-healing environment for the individual wound. Wound dressings are prepared from biopolymers, synthetic polymers and biomaterials.


Clinical, Radiographic And Biochemical Evaluation Of One-Piece Vs Two-Piece Single Implants After 5 Years Of Functional Loading, Ippolito Caputo 2024 University of Roma "La Sapienza"

Clinical, Radiographic And Biochemical Evaluation Of One-Piece Vs Two-Piece Single Implants After 5 Years Of Functional Loading, Ippolito Caputo

Annual Research Symposium

The aim of this study was to compare the clinical and radiographic conditions and the expression of proinflammatory cytokines in peri-implant crevicular fluid (PICF) of two-piece/bone level (TP/BL) versus one-piece/tissue level (OP/TL) single implants with a laser-microgrooved collar after at least 5 years of functional loading.


Anti-Erosion Potential Of Fluoride Solutions Associated With Aminomethacrylate Copolymer: In Situ Randomized Crossover Study, Taiana Paola Prado, Karine Carvalho dos Santos, Carlos Rocha Gomes Torres, Tais Scaramucci, Idalina Vieira Aoki, Alessandra Buhler Borges 2024 Roseman University of Health Sciences

Anti-Erosion Potential Of Fluoride Solutions Associated With Aminomethacrylate Copolymer: In Situ Randomized Crossover Study, Taiana Paola Prado, Karine Carvalho Dos Santos, Carlos Rocha Gomes Torres, Tais Scaramucci, Idalina Vieira Aoki, Alessandra Buhler Borges

Annual Research Symposium

The anti-erosion potential of fluoride solutions associated with aminomethacrylate (AMC) was evaluated in the presence of acquired pellicle on enamel and dentin. It is concluded that AMC was able to increase the anti-erosion potential of fluoride solutions in the presence of acquired pellicle.


Clinical Success Of Restorations With Bioactive And Non-Bioactive Materials: Systematic Review And Network Meta-Analysis, Juliana Benace Fernandes, Sheila Mondragón Contreras, Eduardo Bresciani, Taciana Marco Ferraz Caneppele 2024 Unesp - São Paulo State University

Clinical Success Of Restorations With Bioactive And Non-Bioactive Materials: Systematic Review And Network Meta-Analysis, Juliana Benace Fernandes, Sheila Mondragón Contreras, Eduardo Bresciani, Taciana Marco Ferraz Caneppele

Annual Research Symposium

The oral cavity is a complex and dynamic environment with frequent pH and temperature changes that can affect the longevity of dental restorations. Consequently, bioactive restorative materials, capable of advantageous interactions with the oral environment and dental tissues, are promising alternatives. However, there is limited scientific evidence of their clinical performance. Therefore, we conducted this systematic review and network meta-analysis of clinical studies to address the research question: Does the clinical evaluation of restorations on permanent teeth with bioactive materials show greater success rates than those with non-bioactive materials?


An Emg Study To Evaluate Chewing Efficiency And Maximum Voluntary Clenching (Mvc) For Different Malocclusion Groups Before And During Orthodontic Treatment, Vivek Reddy 2024 Manipal Academy of Higher Education

An Emg Study To Evaluate Chewing Efficiency And Maximum Voluntary Clenching (Mvc) For Different Malocclusion Groups Before And During Orthodontic Treatment, Vivek Reddy

Annual Research Symposium

The purpose of this study was to investigate the efficacy of chewing and maximum voluntary clenching (MVC) of patients with different malocclusion types by measuring the EMG activity in the masseter and temporalis muscles before and during orthodontic treatment.


Bonding Of Composites For Aligner Attachments To The Dental Enamel, Luis Felipe Abbado de Souza 2024 São Paulo State University

Bonding Of Composites For Aligner Attachments To The Dental Enamel, Luis Felipe Abbado De Souza

Annual Research Symposium

The aim of this study was to evaluate the bond strength of flowable composites for aligner attachments to the dental enamel with or without the previous acid etching.


Torsional Evaluation On Different Bending Conditions Of Two Nickel Titanium Rotary Glide Path Files With Different Alloy, Chiara Bramucci 2024 Roseman University of Health Sciences

Torsional Evaluation On Different Bending Conditions Of Two Nickel Titanium Rotary Glide Path Files With Different Alloy, Chiara Bramucci

Annual Research Symposium

The aim of the current study is to compare the torsional resistance of two different glidepath files, the Mtwo 10.04 and the Hyflex EDM Glide Path files 10.05, under different bending conditions.


Influence Of Thickness On The Parameters Of Translucency And Fluorescence Of Direct Bioactive Restorative Materials, Italo Carvalho 2024 Roseman University of Health Sciences

Influence Of Thickness On The Parameters Of Translucency And Fluorescence Of Direct Bioactive Restorative Materials, Italo Carvalho

Annual Research Symposium

The aim of this study was to assess the influence of different thickness on the parameters of translucency and fluorescence of direct bioactive restorative materials.


Brushing And Staining Influence On Esthetic Properties Of Attachment Composites, Marcella Rocha 2024 Roseman University of Health Sciences

Brushing And Staining Influence On Esthetic Properties Of Attachment Composites, Marcella Rocha

Annual Research Symposium

The aim of this study was to evaluate the brushing and staining influence on esthetic and surface properties of resin composites indicated for aligner attachment.


Exploring The Resilience Of Two Commercial Suturing Materials Subjected To Thermocycling And Chlorhexidine Immersion: An In Vitro Study, Devadharshini Chandrasekar 2024 Roseman University of Health Sciences

Exploring The Resilience Of Two Commercial Suturing Materials Subjected To Thermocycling And Chlorhexidine Immersion: An In Vitro Study, Devadharshini Chandrasekar

Annual Research Symposium

To evaluate the durability of two commercially available suture materials (non absorbable Black Braided Silk and absorbable polyglactin 910) subjected to thermocycling after immersing in Chlorhexidine mouthwash.


Restorative Materials And Maintenance Protocols, Renata Budny, Khrystyna Vyprynyuk 2024 CUNY New York City College of Technology

Restorative Materials And Maintenance Protocols, Renata Budny, Khrystyna Vyprynyuk

Publications and Research

No abstract provided.


The Use Of Tissue Grafts Associated With Immediate Implant Placement To Achieve Better Peri-Implant Stability And Efficacy: A Systematic Review And Meta-Analysis, Enrico Maria Rondone, Bruno Leitão-Almeida, Miguel Silva Pereira, Gustavo Fernandes, Tiago Borges 2024 A.T. Still University

The Use Of Tissue Grafts Associated With Immediate Implant Placement To Achieve Better Peri-Implant Stability And Efficacy: A Systematic Review And Meta-Analysis, Enrico Maria Rondone, Bruno Leitão-Almeida, Miguel Silva Pereira, Gustavo Fernandes, Tiago Borges

MOSDOH Faculty Publications

Background: The goal of this systematic study and meta-analysis was to evaluate the efficacy of hard and/or soft tissue grafts associated with type-1 implants on healing and treatment outcomes. The primary outcomes studied were implant survival rate, pocket depth, marginal periimplant recession, bone loss, bone thickness (volumetric change), interproximal bone level, mesial and distal papilla migration, and radiographic evaluation; and the secondary parameters were Pink Esthetic Score (PES), vertical distance from implant shoulder and bone, Visual Analogue Score (VAS), Implant Stability Quotient (ISQ), and biological complications (fistulas, pain, mucositis, and peri-implantitis). Methods: The PICO strategy was used to formulate the …


Fibroblasts And Osteoblasts Behavior After Contact With Different Titanium Surfaces Used As Implant Abutment: An In Vitro Experimental Study, Jose Henrique Cavalcanti de Lima, Patricia Cristina Matos Robbs, Elena Mavropoulos Oliveira Tude, Piedad N. De Aza, Eleani Maria da Costa, Antonio Scarano, Juan Carlos Prados-Frutos, Gustavo Fernandes, Sergio Alexandre Gehrke 2024 A.T. Still University

Fibroblasts And Osteoblasts Behavior After Contact With Different Titanium Surfaces Used As Implant Abutment: An In Vitro Experimental Study, Jose Henrique Cavalcanti De Lima, Patricia Cristina Matos Robbs, Elena Mavropoulos Oliveira Tude, Piedad N. De Aza, Eleani Maria Da Costa, Antonio Scarano, Juan Carlos Prados-Frutos, Gustavo Fernandes, Sergio Alexandre Gehrke

MOSDOH Faculty Publications

Background: The goal of this in vitro study was to compare three different surfaces: two types of implant surfaces commercially available ([a] smooth/machined and [b] acid-treated surface) versus (c) anodized surface. Discs were manufactured with commercially pure titanium (CP) grade IV, which were subsequently analyzed by scanning microscopy and fibroblastic and osteoblastic cell cultures. Methods: Ninety-nine discs (5 × 2 mm) were manufactured in titanium grade IV and received different surface treatments: (i) Mach group: machined; (ii) AA group: double acid etch; and (iii) AN group: anodizing treatment. Three discs from each group were analyzed by Scanning Electron Microscopy (SEM) …


Build Angle Effect On 3d-Printed Dental Crowns Marginal Fit Using Digital Light- Processing And Stereo-Lithography Technology: An In Vitro Study, Omar Elsergany 2024 The British University in Egypt

Build Angle Effect On 3d-Printed Dental Crowns Marginal Fit Using Digital Light- Processing And Stereo-Lithography Technology: An In Vitro Study, Omar Elsergany

Dentistry

Background The effect of 3D printing technology and build angle on the marginal fit of printed crowns is unclear. The objective of this research was to use digital light processing (DLP) and stereo-lithography (SLA)-based 3D printing to construct single restorations with varied build angles and to analyze the crowns′ marginal fit.

Methods A prepared resin first molar was scanned utilizing an optical scanner. Three build orientations were used to construct the specimens: 0, 45, and 90o. DLP and SLA technology were used to produce the casting patterns. A digital microscope was used to measure the marginal gaps. The effect of …


Minimally Invasive Periodontal Regeneration With The Buccal Approach: A Systematic Review And Meta-Analysis Of Clinical Studies, Elisa Pasqualini, Filipe Castro, Denise Curado, Ana Martelete, Artak Heboyan, Muhammad H. Saleh, Juliana Campos Hasse Fernandes, Gustavo Fernandes 2024 A.T. Still University

Minimally Invasive Periodontal Regeneration With The Buccal Approach: A Systematic Review And Meta-Analysis Of Clinical Studies, Elisa Pasqualini, Filipe Castro, Denise Curado, Ana Martelete, Artak Heboyan, Muhammad H. Saleh, Juliana Campos Hasse Fernandes, Gustavo Fernandes

MOSDOH Faculty Publications

OBJECTIVE: The aim of this study was to investigate clinical periodontal parameters after treatment using the Minimally Invasive Surgical Technique (MIST), Modified Minimally Invasive Surgical Technique (M-MIST), and/or any technique for papilla preservation, such as Entire Papilla Preservation (EPP), modified-papilla preservation technique (M-PPT), or simplified-papilla preservation technique (SPPT). METHODS: The focus question was “For patients with periodontal intrabony defects (P), what is the best minimally invasive regenerative approach (I), comparing MIST, M-MIST, and papilla preservation techniques’ outcomes (C) to improve PD, CAL, GR, and periodontal stability (O)?” An online search was conducted on PubMed, Cochrane Library, and Embase. Only randomized …


Is The Facial Bone Wall Critical To Achieving Esthetic Outcomes In Immediate Implant Placement With Immediate Restoration? A Systematic Review, Sergio Charifker Ribeiro Martins, Marcio da Costa Marques, Michael Gomes Vidal, Pedro Henrique Moreira Paulo Tolentino, Roberto Galvão Dinelli, Gustavo Fernandes, Jamil Awad Shibli 2024 A.T. Still University

Is The Facial Bone Wall Critical To Achieving Esthetic Outcomes In Immediate Implant Placement With Immediate Restoration? A Systematic Review, Sergio Charifker Ribeiro Martins, Marcio Da Costa Marques, Michael Gomes Vidal, Pedro Henrique Moreira Paulo Tolentino, Roberto Galvão Dinelli, Gustavo Fernandes, Jamil Awad Shibli

MOSDOH Faculty Publications

Background. Rehabilitation in the anterior region requires specific conditions for success, such as the presence of papilla, emergence profile, and balance between pink and white esthetic. Objectives. This systematic review aimed to evaluate the esthetic risk associated with immediate implant placement with immediate restoration in the anterior superior area, where the facial bone plate may be absent or deficient. Materials and methods. The search was done in PubMed, Embase, Cochrane, Lilacs, Scopus, Scielo, and Google Scholar databases. The investigation involved clinical studies and observational studies published between January 2012 and July 2023. Studies were excluded if there was less than …


Critical-Size Defects Reconstruction With Four Different Bone Grafts Associated With E-Ptfe Membrane: A Histomorphometric Experimental In Vivo Study, Gustavo Fernandes, Filipe Castro, Rafael Martins Pereira, Wendel Teixeira, Sergio Gehrke, Julio Cesar Joly, Juan Blanco Carrion, Juliana Campos Hasse Fernandes 2024 A.T. Still University

Critical-Size Defects Reconstruction With Four Different Bone Grafts Associated With E-Ptfe Membrane: A Histomorphometric Experimental In Vivo Study, Gustavo Fernandes, Filipe Castro, Rafael Martins Pereira, Wendel Teixeira, Sergio Gehrke, Julio Cesar Joly, Juan Blanco Carrion, Juliana Campos Hasse Fernandes

MOSDOH Faculty Publications

Objectives: The goal of this study was to assess the newly formed bone and the remnant biomaterial by comparing four different bone grafts used to treat critical-size defects, associated or not with the non-resorbable membrane.

Materials and methods: Two calvaria critical-size bone defects were created in 50 male Wistar rats. They were divided into blood (G1), autogenous (G2), bioglass (G3), hydroxyapatite (G4), and xenograft (G5) groups, associated or not with e-PTFE. The experimental periods were 15 and 45 days. Sections were prepared for histomorphometric assessment. All data were analyzed by the mixed-effects model with multiple comparisons (significance level, p < .05).

Results: …


Effect Of Different Implant Materials On Stresses Transmitted To Peri-Implant Areas Of Implant-Retained Mandibular Overdenture, Diaa Mohamed Zahran Future University in Egypt, [email protected], Aya Fawzy Associate Professor of Prosthodontics, Future University in Egypt, [email protected], Salah Hegazy Professor of Prosthodontics, Faculty of dentistry, Mansoura University, [email protected], Sara M. Shabaan Lecturer at Removable Prosthodontic Department, Faculty of Oral and Dental Medicine , Badr University, Cairo, Egypt, Ahmed A.Elwahed Shaaban Associate professor of Prosthodontics, Future University in Egypt, [email protected] 2024 Future University in Egypt

Effect Of Different Implant Materials On Stresses Transmitted To Peri-Implant Areas Of Implant-Retained Mandibular Overdenture, Diaa Mohamed Zahran Future University In Egypt, [email protected], Aya Fawzy Associate Professor Of Prosthodontics, Future University In Egypt, [email protected], Salah Hegazy Professor Of Prosthodontics, Faculty Of Dentistry, Mansoura University, [email protected], Sara M. Shabaan Lecturer At Removable Prosthodontic Department, Faculty Of Oral And Dental Medicine , Badr University, Cairo, Egypt, Ahmed A.Elwahed Shaaban Associate Professor Of Prosthodontics, Future University In Egypt, [email protected]

Future Dental Journal

Aim this in vitro study was conducted to evaluate the effect of mechanical loading on different implant materials on supporting structures materials and methods: a total of three implant retained overdentures were used in this study, retained by two implants each (Titanium, polyetheretherketon and zirconia) were placed in epoxy resin casts at the canine area using a surgical guide. Soft liner material was used at the distal extension area to mimic the soft tissues. Two linear strain gauges were bonded buccal and lingual to each implant to measure the peri-implant strains during unilateral and bilateral loading. Results: during bilateral loading …


Effect Of Scan Body Design On The Accuracy Of The Implant Position In Implant Supported Prosthesis, Ahmed Safwat Elghazally ,Future University in Egypt, [email protected], Bassem Mohsen Associate professor of prosthodontics, Future University in Egypt, [email protected], Amr Hosny Professor of Prosthodontics, Faculty of Dentistry – Cairo University in Egypt, [email protected], Hussien G. Elcharkawi professor of prosthodontics, Future University in Egypt, [email protected] 2024 Future University in Egypt

Effect Of Scan Body Design On The Accuracy Of The Implant Position In Implant Supported Prosthesis, Ahmed Safwat Elghazally ,Future University In Egypt, [email protected], Bassem Mohsen Associate Professor Of Prosthodontics, Future University In Egypt, [email protected], Amr Hosny Professor Of Prosthodontics, Faculty Of Dentistry – Cairo University In Egypt, [email protected], Hussien G. Elcharkawi Professor Of Prosthodontics, Future University In Egypt, [email protected]

Future Dental Journal

Background: Several treatment options are planned for completely edentulous patients rehabilitation which were developed to meet patients desires and requirements, starting from conventional complete denture till implant supported fixed full arch cases. Each technique has its own indication and limitations. Passive fit is an important factor for the long-term success of implant- prosthesis, which necessitate accurate transfer of the implant position. Recently, digital impressions have been introduced in dental implant treatment. By the use of scan body and different optical scanning methods, the position of scan bodies can be transferred to a virtual implant position within the dental arch. Material …


Digital Commons powered by bepress