Open Access. Powered by Scholars. Published by Universities.®

Dental Materials Commons

Open Access. Powered by Scholars. Published by Universities.®

Discipline
Institution
Keyword
Publication Year
Publication
Publication Type
File Type

Articles 601 - 630 of 746

Full-Text Articles in Dental Materials

Microleakage Of Various Restorative Materials Used For Preventive Resin Restorations, Jenny Chung Lee Jun 2002

Microleakage Of Various Restorative Materials Used For Preventive Resin Restorations, Jenny Chung Lee

Loma Linda University Electronic Theses, Dissertations & Projects

Introduction: This research was designed to compare the microleakage of various restorative materials used for preventive resin restorations and two methods of cavity preparation. The purpose of this study was: (1) to compare microleakage of four different restorative materials using two different type of preparation methods (bur and air particle abrasion) and (2) whether the use of a pit and fissure sealant over the restoration decreases microleakage.

Methods: One hundred and twenty eight, permanent human molars were randomly divided into four groups and restored with four restorative materials. Each group had been randomly divided into two subgroups. The teeth in …


Hard Tissue Healing Adjacent To Fresh Or Set Mta As Root-End Filling Material, Erol S. Apaydin Mar 2002

Hard Tissue Healing Adjacent To Fresh Or Set Mta As Root-End Filling Material, Erol S. Apaydin

Loma Linda University Electronic Theses, Dissertations & Projects

Mineral trioxide aggregate (MTA) has been shown to promote regeneration of periradicular tissues when used as a root-end filling material. The purpose of this study was to compare the effect of fresh MTA with set MTA on hard tissue healing following periradicular surgery.

Under general anesthesia, the root canals of twenty-four mandibular premolars in four 2-year-old beagle dogs were filled with MTA. Two weeks later the root-ends of half of the samples were surgically exposed and resected to the level of set MTA within the canals. After exposing and resecting the other 12 root-ends, class I cavities were prepared in …


A Scanning Electron Microscopy Comparison Of The Effects Of The Arkansas Stone And The Ida-Hone Ceramic Stone On Curet Sharpness And Root Smoothness, Marian Gayle Rubino Jul 2001

A Scanning Electron Microscopy Comparison Of The Effects Of The Arkansas Stone And The Ida-Hone Ceramic Stone On Curet Sharpness And Root Smoothness, Marian Gayle Rubino

Dental Hygiene Theses & Dissertations

Purpose: The purpose of this study was to determine if there are statistically significant differences between the Arkansas sharpening stone and the Ida-Hone ceramic sharpening stone in producing a sharper cutting edge on dental curets, and to determine if there is a statistically significant difference between the degree of root smoothness achieved by the sharpened curet cutting edges on extracted human teeth.

Methods: A two-group, randomized subject (n=39), double blind, post-test only design was employed using 39 factory new Hu-Friedy 11/12 gracey curets. Curets in group one were sharpened using the Ida-Hone ceramic stone, curets in group two were sharpened …


Hard Tissue Forming Potential Of Mta Compared To Common Root-End Filling Materials, Nooshin Noghreian Jun 2001

Hard Tissue Forming Potential Of Mta Compared To Common Root-End Filling Materials, Nooshin Noghreian

Loma Linda University Electronic Theses, Dissertations & Projects

An ideal characteristic of root-end filling materials used in endodontics is the ability to enhance hard tissue formation. Studies have shown that MTA has the potential to enhance hard tissue formation when placed in contact with periradicular tissues. The mechanisms involved in hard tissue formation of MTA and other root-end filling materials have not been completely elucidated. The purpose of this investigation was to study the mechanism of hard tissue formation of commonly used root-end filling materials and MTA by evaluating alkaline phosphatase (ALP) activity and cell layer protein. Extracts of materials tested in this experiment were added to the …


Fracture Properties Of Different Orthodontic Bonding Materials, Daryl Lynden Proctor Jun 2001

Fracture Properties Of Different Orthodontic Bonding Materials, Daryl Lynden Proctor

Loma Linda University Electronic Theses, Dissertations & Projects

Spontaneous debonding has proven a constant problem since the introduction of bonded orthodontic brackets in the early 1960's by Newman1.

Components in classic bond strength testing are the bracket, the adhesive, the adhesive curing method, the type of teeth used, and the test method. These tests lead to extensive and compounding variables that make it difficult to evaluate the performance of any of the components individually.

The purpose of this study was to compare several contemporary orthodontic bonding adhesives by testing the physical and mechanical characteristics of the adhesives alone. Material properties compared were sonic and tensile measurements …


Evaluating Pit And Fissure Sealant Materials When Used As Bonding Agents In Preventive Resin Restorations, Paul Shields Gerber Jun 2001

Evaluating Pit And Fissure Sealant Materials When Used As Bonding Agents In Preventive Resin Restorations, Paul Shields Gerber

Loma Linda University Electronic Theses, Dissertations & Projects

Preventive resin restorations (PRR) are an increasingly popular alternative to the traditional amalgam restoration for small occlusal caries in posterior teeth. The technique for placing the PRR was first suggested by Simonsen (1980) and involved a minimal removal of tooth structure. After preparation, the tooth is etched, followed by an application of a bonding agent, filled with composite, and then sealed with a pit and fissure sealant. In an attempt to simplify the protocol of the PRR this study was designed to determine if pit and fissure sealant material could serve a dual role and eliminate the need for a …


Failure Mode Of An Orthodontic Resin Alone And With Bonded Brackets, Marc Cody Dunn Jun 2000

Failure Mode Of An Orthodontic Resin Alone And With Bonded Brackets, Marc Cody Dunn

Loma Linda University Electronic Theses, Dissertations & Projects

Since the introduction of bonded orthodontic brackets in the early 1960's spontaneous debonding has been a constant nemesis. Most attempts to avoid this problem by orthodontic manufactures have focused on "bond strength" issue. Whether they chose to address the materials, the bracket base or both, the common method used to evaluate improvements entailed the use of just one testing apparatus: a static universal testing machine such as the Instron.

Metal, ceramic and plastic bonded brackets were tested with the traditional shear/peel method as well as a new high strain rate impact test. The resin itself was also evaluated for physical …


Ua60/5/1 Scapbook, Junior American Dental Hygienist's Association Jan 2000

Ua60/5/1 Scapbook, Junior American Dental Hygienist's Association

Student Organizations

Scrapbook documenting Class of 2000 Junior American Dental Hygienist's Association at WKU. People included in the scrapbook are: Amy Adams, Jennifer Brown, Emily Cook, Holly Cothron, Rhonda Craven, Belinda Curtisr, Hannah Dugger, Michell Franklin, DeVana Garland, Christie Gott, Laura Greenwell, Laura Hill, Amy Hiser, Amy Hodges, Michael Hooper, ? Howard, Shannon Johnson, Tonya Joiner, Julie Lane, Amy McCarty, Charlene Pierce, Julie Ploef, Jennifer Roach, Tracey Surina, ? Tabor, Carmi Thompson, Tracey Vanhook, Christy White and Hanna Winegar.


Clinical Debonding Simulation Study Of One Metal And Two Ceramic Brackets, Hyunsup Shim Sep 1999

Clinical Debonding Simulation Study Of One Metal And Two Ceramic Brackets, Hyunsup Shim

Loma Linda University Electronic Theses, Dissertations & Projects

The purpose of this study is to compare two mechanical debonding methods on ceramic brackets (TP MXi and 3M Clarity) and a metal bracket (GAC OmniArch) with four different bonding materials (light-cured, one-step chemical-cured, two-step chemical-cured, and Fuji GIC) in clinical simulation, where the diametral force was applied on the handle of the pliers. The effectiveness of mechanical debonding technique was determined by evaluating the following variables: the amount of force required to debond the bracket, the amount of residual adhesive remaining on the enamel surface, the frequency of unexpected bracket failure, and the prevalence of visible enamel damage. The …


Evaluation Of The Effects Of Heat Treatment Using Orthotherm On Thermally Activated Archwires, Brent J. Hurst Jun 1999

Evaluation Of The Effects Of Heat Treatment Using Orthotherm On Thermally Activated Archwires, Brent J. Hurst

Loma Linda University Electronic Theses, Dissertations & Projects

The purpose of this study was to evaluate the effects of heat treatment on thermally activated nickel titanium archwires, and to determine the differences between wires from individual manufacturers. Thermally activated, nickel titanium wires were obtained from five different manufacturers in the 0.016 x 0.022 format. All wires were measured with a micrometer to determine their exact dimensions. Half of the wires were heat treated with the use of the Orthotherm Bending Art Programmer from Syrinx Medical Technologies (Berlin, Germany) while the other half served as a control. By passing an electrical current through the wires for a predetermined period …


A Comparison Of Bond Strength Between Three Glass Ionomer Cements Used For The Retention Of Orthodontic Bands, Bryan C. Johnson Sep 1998

A Comparison Of Bond Strength Between Three Glass Ionomer Cements Used For The Retention Of Orthodontic Bands, Bryan C. Johnson

Loma Linda University Electronic Theses, Dissertations & Projects

The study compared the retentive bond strength of Ketac-Cem with Ultra Bond-Lok and a 3M Experimental glass ionomer cement at 1 hour and 24 hours using laser and common light cure techniques. The sample consisted of one hundred twenty sound extracted human molars divided into 5 groups: Ketac-Cem (self-cure), Ultra Band-Lok (light-cure), Ultra Band-Lok (laser cure), 3M Experimental (light-cure) and 3M Experimental (laser cure). Stainless steel orthodontic bands with buccal and lingual cleats were cemented as per manufacturer's instructions for each of the test samples. The samples were placed in water until ready for testing. The shear bond strength of …


An Evaluation Of Root End Filling Materials Using Endotoxin, Hong-Ming Tang Jun 1998

An Evaluation Of Root End Filling Materials Using Endotoxin, Hong-Ming Tang

Loma Linda University Electronic Theses, Dissertations & Projects

Mineral Trioxide Aggregates (MTA) was recently developed at Loma Linda University. It has been shown to possess good sealing ability when tested with dye, bacteria, and a fluid filtration technique.

Endotoxin is a component of the cell wall of Gram negative bacteria. It has been proposed that it may play a role in the pathogenesis of periradicular lesions. Previous studies have demonstrated that MTA can prevent the leakage of bacteria. However, the bacterial products were not tested during these studies.

This study used endotoxin to compare the sealing ability of SuperEBA, IRM, amalgam, and MTA.

The results showed that MTA …


A Pilot Study Testing A Proprietary Sealant For Plaque Reduction, Jennifer Rowland Jun 1998

A Pilot Study Testing A Proprietary Sealant For Plaque Reduction, Jennifer Rowland

Loma Linda University Electronic Theses, Dissertations & Projects

Enamel demineralization due to increased plaque accumulation is a well-recognized problem associated with fixed orthodontic appliances. The purpose of this study was to evaluate the efficacy of a proprietary product to be marketed by 3M Unitek for the reduction of plaque accumulation and thereby reduce enamel demineralization.

Sixty four bovine teeth were divided equally into an untreated control group and a group treated with the proprietary sealant product. Both groups were subsequently immersed in a Streptococcus mutans culture. Plaque deposits from each group were removed, suspended in trypticase soy broth, serially diluted, and plated on trypticase soy agar at 1, …


An In Vitro Study Of Plaque Deposition And Its Comparative Effect On Bond Strength, Debra L. Finch Cook Jun 1998

An In Vitro Study Of Plaque Deposition And Its Comparative Effect On Bond Strength, Debra L. Finch Cook

Loma Linda University Electronic Theses, Dissertations & Projects

Treatment with fixed orthodontic appliances can change the environment in the oral cavity by creating stagnant areas that facilitate bacterial colonization and substance retention. The purpose of this study was to examine in vitro plaque formation associated with bonded orthodontic appliances and how this could affect bonding strengths.

Ortho Concise and Transbond XT were the composite resin materials used in this study. Mandibular incisor metal brackets were bonded to bovine mandibular anterior teeth. Each composite resin was studied in two groups: plaque growth and without plaque growth, and their bond strengths were compared at time intervals of 3,45, and 180 …


The Effect Of Root End Demineralization On Cementogenesis : A Long Term Investigation, Hamid R. Abedi Dec 1997

The Effect Of Root End Demineralization On Cementogenesis : A Long Term Investigation, Hamid R. Abedi

Loma Linda University Electronic Theses, Dissertations & Projects

Craig and Harrison12 examined the effect of demineralization of resected root ends on wound healing following periradicular surgery. Based on its microscopic evaluations from 4-45 days, it was proposed that demineralization of resected root ends enhances cementogenesis. The purpose of this study was to investigate the longer term effects of demineralization on cementogenesis using Mineral Trioxide Aggregate (MTA) or amalgam as root end filling materials. After completion of root canal therapy and endodontic surgery on seventy-two roots of mandibular second, third and fourth premolars of six beagle dogs, 32/72 of the root ends at random were etched with 50% …


A Comparative Study Of The Permanent Deformation Of Aesthetic Polymer Brackets, Samar Bou Assi Jun 1997

A Comparative Study Of The Permanent Deformation Of Aesthetic Polymer Brackets, Samar Bou Assi

Loma Linda University Electronic Theses, Dissertations & Projects

The purpose of this study was to Investigate and compare the plastic or permanent deformation of different commercially available aesthetic polymer brackets (American, Ormco, GAC and RMO). It also examined the effect of tying the bracket wings with a wire ligature as well as the effect of thermocycling on the permanent deformation of these brackets.

Seven brackets of each type were tested In each of the three following conditions; group 1; tied with a wire ligature and loaded, group 2; thermocycled and loaded, and group 3: loaded only, with a total of 84 brackets tested. Each bracket was bonded to …


The Relationship Of Tooth Size And Arch Form To Arch Depth, Harold C. Avila Jun 1997

The Relationship Of Tooth Size And Arch Form To Arch Depth, Harold C. Avila

Loma Linda University Electronic Theses, Dissertations & Projects

The purpose of this study was to determine the relationship of arch form and tooth size to arch depth measurements of study models (Casts) and their respective lateral cephalometric radiographs (Radiographs) in a population of patients treated to an acceptable occlusion without extraction. One hundred and twenty casts were divided into three tooth size classes within each of four arch form categories. Results showed there was a statistically significant change in the arch depth measurement when tooth size was varied. There was no statistically significant change in the arch depth measurement when arch form was varied. The results showed greater …


Change In Bracket Bond Strength And Enamel Calcium : Due To Repeated Bonding With Conventional And Resinomer Glass Ionomer Cements, David L. Wilkinson Aug 1996

Change In Bracket Bond Strength And Enamel Calcium : Due To Repeated Bonding With Conventional And Resinomer Glass Ionomer Cements, David L. Wilkinson

Loma Linda University Electronic Theses, Dissertations & Projects

Glass ionomers chemically and mechanically bond to enamel. Repeated bonding may deplete calcium in enamel and reduce the bond strength. Seventy-five non-carious molars were randomly divided into three equal groups and metal brackets were bonded with either Ketac-Cem, Photac-Bond, or Fuji Ortho LC. The samples were stored in 100% humidity at 37° C for 7 days then shear/peel tested with an Instron machine. New brackets were repeatedly cemented with the same cement to the same tooth and shear/peel tested a total of five times. After each shear/peel test the tooth with the mean bond strength from each cement was set …


In Vitro Plaque Formation On Orthodontic Resin Sealants, Leland W. Pack Jun 1996

In Vitro Plaque Formation On Orthodontic Resin Sealants, Leland W. Pack

Loma Linda University Electronic Theses, Dissertations & Projects

The purpose of this study was to examine in vitro plaque formation on sealant coated enamel. The plaque growth on different types of sealants placed on enamel was compared to each other and to an unsealed enamel control. The antimicrobial properties of sealants were also studied.

Sealant coated bovine enamel disks were immersed in a S. mutans culture medium for four days. The amount of bacterial plaque formation was quantified by removing the deposit, suspending it in solution with subsequent serial dilution. Aliquots of the dilutions were then spread on blood agar plates and incubated for 48 hours. The number …


Mutagenecity Of Formocresol, Glutaraldehyde, Ferric Sulfate And Aluminum Chloride : Materials Used In Therapeutic Pulpotomies, Adolfo Barrera Jun 1996

Mutagenecity Of Formocresol, Glutaraldehyde, Ferric Sulfate And Aluminum Chloride : Materials Used In Therapeutic Pulpotomies, Adolfo Barrera

Loma Linda University Electronic Theses, Dissertations & Projects

Ferric sulfate (Astringedent) and aluminum chloride (Hemodent) have been proposed as possible medicaments for use in primary teeth for therapeutic pulpotomies.

There is little information in the literature about the biologic properties of these medicaments.

The purpose of this study was to evaluate the mutagenic response of the ferric sulfate and aluminum chloride and compare them with glutaraldehyde (1.5%, 1% and 0.5% concentration) and formocresol (2%, 0.75%, 0.01% and 0.005% concentration). TA98 and TA1535 strain were used in the Ames test to assess mutagenecity. Neither ferric sulfate nor aluminum chloride exhibited mutagenic potential, in comparison with glutaraldehyde and formocresol, which …


Relationship Between Design Marketing Strategies And Toothbrush Purchases By Consumers, Cynthia Lynn Garvin Apr 1996

Relationship Between Design Marketing Strategies And Toothbrush Purchases By Consumers, Cynthia Lynn Garvin

Dental Hygiene Theses & Dissertations

The purpose of this study was to investigate whether a relationship exists between design marketing strategies of toothbrushes (handle size, color, and shape; brush head size and shape; and bristle firmness and formation of toothbrushes) and toothbrush purchases made by consumers. To understand what consumers preferred, a self-designed, 24 item questionnaire, "Toothbrush Design and Consumer Preferences," was given to a convenience sample of 300 subjects ranging from ages 20 to 60 and over from the Old Dominion University campus in Norfolk, Virginia. Responses from each item were analyzed using frequency and percentages of responses, contingency tables, Kendall's tau b, and …


Physical And Biological Evaluation Of Hydroxylapatite Films Formed On Ti6a14v Substrates By Excimer Laser Ablation, Tatjana Dostálová, Miroslav Jelínek, Lucie Himmlová, Vlasta Pesáková, Milan Adam Jan 1996

Physical And Biological Evaluation Of Hydroxylapatite Films Formed On Ti6a14v Substrates By Excimer Laser Ablation, Tatjana Dostálová, Miroslav Jelínek, Lucie Himmlová, Vlasta Pesáková, Milan Adam

Cells and Materials

Thin films of hydroxylapatite, about 500 nm, were formed on Ti6Al4V by excimer laser ablation. Ten different deposition conditions were used such as deposition atmosphere (vacuum, pure water vapor, mixture of Ar and water vapor), substrate temperature, target-substrate distance and energy density. Mechanical and physical analyses were carried out by Rutherford backscattering and particle induced X-ray emission; crystallinity of films was determined by X-ray diffraction, surface topography by scanning electron microscopy and adhesion by a scratch test. Biological evaluation of samples was also performed. The fibroblast proliferation test was used, morphological evaluation of macrophages was carried out, and the activity …


An Immediate Implant Stability And Pull-Out Study Comparing Two Different Surgical Techniques : Conventional Drilling Versus Trabecular Compaction : A Pilot Study, Yong Chang Choi Sep 1995

An Immediate Implant Stability And Pull-Out Study Comparing Two Different Surgical Techniques : Conventional Drilling Versus Trabecular Compaction : A Pilot Study, Yong Chang Choi

Loma Linda University Electronic Theses, Dissertations & Projects

Poor bone quality at an implant site and the lack of initial implant immobilization are considered the two main factors for first stage implant failure. Modalities are needed to improve the initial stability of implants in poor bone quality situations. The purpose of this study was to compare the immediate implant stability and the pull-out force of implants placed in fresh frozen human alveolar jaw bones by two different surgical techniques: 1) a conventional drilling technique and 2) a trabecular compaction technique. The initial lateral stability (assessed by Periotest values, PTVs), the uniaxial pull-out force (measured by Instron machine) and …


A Comparison Of Retentive Strengths Of Two Types Of Inner Surface Treatments Of Orthodontic Bands, Jean M. Rathbun Jun 1995

A Comparison Of Retentive Strengths Of Two Types Of Inner Surface Treatments Of Orthodontic Bands, Jean M. Rathbun

Loma Linda University Electronic Theses, Dissertations & Projects

Band failure during orthodontic treatment results in a potential for decalcification and/or caries and may cause a prolonged treatment time. An increase in the bond strength at the cement/band interface would likely decrease clinical band failure. Sand-blasting and photo-etching have been suggested to improve this bond.

This study investigated the retentive strengths of untreated orthodontic bands, sand-blasted bands and photo-etched bands when cemented with glass polyalkenoate cement on extracted human molars. The sand-blasted bands and photo-etched bands were both found to have significantly stronger bond strengths (p


The Effects Of Rapid Palatal Expansion Therapy On The Periodontal Tissues Of The Central Incisors, Richard Gutierrez Jun 1995

The Effects Of Rapid Palatal Expansion Therapy On The Periodontal Tissues Of The Central Incisors, Richard Gutierrez

Loma Linda University Electronic Theses, Dissertations & Projects

The periodontal structures around the maxillary central incisors in thirty-nine post-orthodontically treated patients, twenty-five of these patients had experienced Rapid Palatal Expansion (RPE), were examined to determine the periodontal consequences associated with two ways of managing the resultant diastema. In fourteen patients the diastema closure was assisted by elastomeric chain and in eleven patients the diastema closure was not assisted. Fourteen non-RPE orthodontically treated patients served as controls. Height of attached gingiva, gingival sulcus depth, attachment level, and alveolar bone level were recorded. One examiner, using calibrated techniques, performed all the measurements. The RPE groups and the control group all …


Plastic Deformation Of A Polycarbonate Bracket : Utilizing A New Testing Apparatus, Terri L. Alfred Jun 1995

Plastic Deformation Of A Polycarbonate Bracket : Utilizing A New Testing Apparatus, Terri L. Alfred

Loma Linda University Electronic Theses, Dissertations & Projects

The purpose of this study was to investigate the plastic (permanent) deformation of a polycarbonate bracket (Miura, RMO) under the following different conditions: (1) untreated, (2) immersed in 37°C-water for 120 days, and (3) immersed in 60°C-water for 24 hours. Ten brackets for each condition were tested, with a total of 30 brackets tested. Each bracket was bonded to a metal mesh pad which was tack welded to a solid stainless steel ring. The assembly was placed under a loading frame. This loading frame removes variables such as bond adhesive strengths, distortion of a wire used to deform the bracket …


Room Temperature Aging Of Pd-Cu-Ga Dental Alloys, William A. Brantley, Zhuo Cai, Qiang Wu, Alan B. Carr, John C. Mitchell Jan 1995

Room Temperature Aging Of Pd-Cu-Ga Dental Alloys, William A. Brantley, Zhuo Cai, Qiang Wu, Alan B. Carr, John C. Mitchell

Cells and Materials

Specimens of three Pd-Cu-Ga dental alloys cast five years ago and subsequently stored at room temperature were reexamined and observed to have lower amounts of the eutectic constituents in the near-surface region than originally present, along with other microstructural changes. This previously unreported room temperature aging behavior of these alloys is attributed to the presence of high-diffusivity paths in the non-equilibrium ascast eutectic structures and to the essential role of the surface for the vacancy diffusion mechanism. These results may have important clinical significance for the ill vivo corrosion resistance and long-term biocompatibility of the Pd-Cu-Ga alloys.


A Pilot Study Comparing The Forces Applied : Using A Chin Cup And Three Types Of Protraction Headgear, Daniel Miles Beisiegel Dec 1994

A Pilot Study Comparing The Forces Applied : Using A Chin Cup And Three Types Of Protraction Headgear, Daniel Miles Beisiegel

Loma Linda University Electronic Theses, Dissertations & Projects

A pilot study comparing force distributions of a chin cup, the Great Lakes reverse pull headgear (RPHG), Ormco's adjustable dynamic RPHG, and Grummons RPHG was done. A skull from a 69 year old female which demonstrated a Class III malocclusion was used to perform the tests of force. Forces applied to and generated on the skull were measured using a water-filled balloon system. This method was tested and found to be reliable and accurate.

Repeated measurements of force were recorded for each of the areas of stress (forehead, cheeks, chin, and condyles, as well as the posterior and superior portions …


Effects Of A Commercial Sodium Bicarbonate Toothpaste On Composite Restorative Material, Maggie Jackson Jul 1994

Effects Of A Commercial Sodium Bicarbonate Toothpaste On Composite Restorative Material, Maggie Jackson

Dental Hygiene Theses & Dissertations

Commercial sodium bicarbonate toothpaste is a relatively new product on the market and limited research has tested its effects on composite material. The purpose of this investigation was to determine and compare, invitro, the effects of a commercially available sodium bicarbonate toothpaste versus a leading brand of fluoridated toothpaste on composite restorative material simulated in daily toothbrushing for a six month time period. Deionized water was used as the control treatment. A three-group, post-test only design was used to test the abrasive effects of the paste on 48 filled composite resin shade guide teeth. The digital microprocessor scanning device, a …


An In Vitro Quantitative Evaluation And Comparison Of A Custom And A Popular Stock Orthodontic Appliance, Richard Scott Anderw Schalo Jun 1994

An In Vitro Quantitative Evaluation And Comparison Of A Custom And A Popular Stock Orthodontic Appliance, Richard Scott Anderw Schalo

Loma Linda University Electronic Theses, Dissertations & Projects

An in vitro performance evaluation and comparison of a patient individualized appliance (Elan, Ormco Corporation, Glendora, California) and a Roth prescription appliance ("A"- Company, San Diego, California) was made using the Ideal Tooth Relationship Index (ITRI).

The sample consisted of 19 duplicated sets of models for a total sample of 38. For each pair of models one set was bonded with an Elan appliance and a duplicated set was bonded with a Roth appliance. Bracket placement followed the manufacturers recommendations. The bracketed teeth from these models were sectioned out individually and the appliances allowed to fully express themselves on full …