Open Access. Powered by Scholars. Published by Universities.®
- Discipline
- Publication
- Publication Type
Articles 1 - 30 of 57
Full-Text Articles in Dental Materials
Biocompatibility And Anti-Inflammatory Effects Of Thai Cannabidiol-Containing Topical Anesthetic Gel Prototype In A Dermal Irritation Test, Pasutha Thunyakitpisal, Supattarayan Thongjit, Apitchaya Pruksametanan, Wijit Banlunara Assoc. Prof.
Biocompatibility And Anti-Inflammatory Effects Of Thai Cannabidiol-Containing Topical Anesthetic Gel Prototype In A Dermal Irritation Test, Pasutha Thunyakitpisal, Supattarayan Thongjit, Apitchaya Pruksametanan, Wijit Banlunara Assoc. Prof.
The Thai Journal of Veterinary Medicine
The objective of this study is to investigate and compare the effect of cannabidiol (CBD)-containing and non-CBD topical anesthetic gel prototypes on skin irritation in rabbits at 24, 48, and 72 h post-application. Topical anesthetic gel prototypes containing 0.1% CBD and without CBD were developed. Six rabbits (Oryctolagus cuniculus) were used for skin irritation testing according to ISO 10993-23: 2021. The animals were randomly and equally divided into two groups (CBD and non-CBD gel groups). The gels were applied to the animals’ skin at the dorsal area of the flank with good contact for 4 h. Distilled water …
Evaluation Of Blending Ability Of Single-Shade Composite Relating To Different Cavity Depths And Abrasive Wear From Toothbrushing, Nattaporn Verayangkura
Evaluation Of Blending Ability Of Single-Shade Composite Relating To Different Cavity Depths And Abrasive Wear From Toothbrushing, Nattaporn Verayangkura
Chulalongkorn University Theses and Dissertations (Chula ETD)
Materials and Method: Eighty extracted human premolars were used for the shade‑matching evaluation. The materials tested in this study were Omnichroma (OC), Vittra APS Unique (VU), Charisma Diamond One (CD), and Filtek Z350 XT (FZ, control). The initial tooth shade was determined using a dental spectrophotometer and the reference color parameters (L, C, and H) were recorded with a laboratory spectrophotometer. A 4‑mm‑diameter cylindrical cavity was prepared in each tooth at restoration depths of either 1 mm or 2 mm. The prepared teeth in each restoration depth group were further divided into four subgroups based on the resin composite material …
The Comparison Of Learning Outcome Between Implant Placement Training With Xguide Vs Iris100 Navigation In Different Anatomical Situations, Supichaya Thanasanpaiboon
The Comparison Of Learning Outcome Between Implant Placement Training With Xguide Vs Iris100 Navigation In Different Anatomical Situations, Supichaya Thanasanpaiboon
Chulalongkorn University Theses and Dissertations (Chula ETD)
This study aimed to evaluate the learning outcomes, accuracy, efficiency, and user perceptions of two dynamic navigation systems, X-Guide and IRIS-100, in implant placement training for novice dentists across varying anatomical complexities.Fourteen novice dentists were initially recruited, with 12 completing the full training program. Participants underwent implant placement training on models representing straightforward and advanced cases using two training sequences: X-Guide followed by IRIS-100, and IRIS-100 followed by X-Guide. Accuracy was assessed by measuring angular, coronal, and apical deviations, as well as operation time, across pre-test, post-test 1, and post-test 2 phases using the freehand technique, followed by repeated measures …
Inflammatory Responses Of Peri-Implant Crevicular Fluid On Different Dental Implant Abutment Materials After 6-Months Functional Loading: A Randomized Clinical Controlled Trial, Penkamol Wongrattanapasson
Inflammatory Responses Of Peri-Implant Crevicular Fluid On Different Dental Implant Abutment Materials After 6-Months Functional Loading: A Randomized Clinical Controlled Trial, Penkamol Wongrattanapasson
Chulalongkorn University Theses and Dissertations (Chula ETD)
Different abutment materials induce different immune responses in peri-implant soft tissues. Previous study showed that Ti base abutments without loading demonstrated comparable soft tissue-reaction to titanium abutments (Sampatanukul et al., 2018). Inflammatory responses after functional loading had not been elucidated in the previous study. This study investigates the inflammatory responses of peri-implant crevicular fluid around two abutment materials; titanium and titanium base (Ti base) after 6-months functional loading and identifies suitable abutment material which can induce stable inflammatory response in the peri-implant soft tissue. Sixteen implants of either Neodent or Straumann single implants were placed in sixteen patients in anterior …
The Effect Of Surface Treatments And Coffee Thermocycling On Color Stability And Translucency Of Cad-Cam Polychromatic High-Translucent Zirconia Compared With Lithium Disilicate Glass Ceramic, Ratchaphat Khomprang
The Effect Of Surface Treatments And Coffee Thermocycling On Color Stability And Translucency Of Cad-Cam Polychromatic High-Translucent Zirconia Compared With Lithium Disilicate Glass Ceramic, Ratchaphat Khomprang
Chulalongkorn University Theses and Dissertations (Chula ETD)
Objectives: To evaluate effects of surface treatments on the color stability (ΔE) and translucency parameter (TP) of Gradient Multilayered yttria-stabilized Zirconia (GMZ), Ultra-translucent multilayered Zirconia (UTML) and lithium disilicate glass ceramic (LD) under coffee thermocycling. Methods: 27 samples from each material were classified into 3 groups (polished, glazed, and glazed+pumice). A dental spectrophotometer was utilized to measure the color coordinates before and after thermocycling. The color and translucency differences (ΔE and ΔTP) measurements were determined using the CIELAB formula, and their corresponding 50%:50% perceptibility and acceptability thresholds (PT and AT) were used for analysis. One-way ANOVA and Two-way ANOVA was …
Oral Health-Related Quality Of Life, Patient’S Satisfaction And The Clinical Performance Of Anterior Ceramic Veneers Criteria In 10 Years Clinical Cross-Section Study, Thitiorn Panayong
Oral Health-Related Quality Of Life, Patient’S Satisfaction And The Clinical Performance Of Anterior Ceramic Veneers Criteria In 10 Years Clinical Cross-Section Study, Thitiorn Panayong
Chulalongkorn University Theses and Dissertations (Chula ETD)
Objectives: The purpose of this study was to evaluate the clinical performance of ceramic veneers after 9-10 years, assess oral health-related quality of life and patient’s satisfaction, and examine the associations between them. Materials and Methods: 30 patients who treated with ceramic veneers aged 9 to 10 years were recalled for a clinical examination. Each participant completed a questionnaire on satisfaction and oral health-related quality of life, using the Oral Impact on Daily Performance (OIDP) scale. The Chi-square or Fisher Exact test was used to assess associations between tooth position and professional evaluations of veneer success and individual items. Consistency …
Esthetic Evaluation Of Implant Restoration In Esthetic Zone: A Long-Term Follow-Up, Harit Muangmore
Esthetic Evaluation Of Implant Restoration In Esthetic Zone: A Long-Term Follow-Up, Harit Muangmore
Chulalongkorn University Theses and Dissertations (Chula ETD)
Objective: This study aimed to evaluate the correlation between esthetic outcomes of single-tooth implant restorations (STIRs) in the anterior maxilla, assessed by the Pink Esthetic Score (PES), White Esthetic Score (WES), and the newly introduced Esthetic Sustainable Criteria (ESC), over two follow-up periods: 5 years and 10 years. Materials and Methods: A cross-sectional retrospective study was conducted involving 22 patients treated with STIRs at the Faculty of Dentistry, Chulalongkorn University, from January 2009 to December 2024. Patient demographics, treatment protocols, and follow-up assessments were collected at both 5 and 10 years. PES and WES were utilized to evaluate esthetic outcomes, …
A Comparison Of Crestal Bone Loss Between Healing Abutment And Customized Abutment; 6 Months Clinical Observation, Adison Jirasuwannakul
A Comparison Of Crestal Bone Loss Between Healing Abutment And Customized Abutment; 6 Months Clinical Observation, Adison Jirasuwannakul
Chulalongkorn University Theses and Dissertations (Chula ETD)
Adison Jirasuwannakul : A Comparison of crestal bone loss between healing abutment and customized abutment ; 6 months clinical observation. Advisor: Associate Professor Pravej Serichetaphongse, D.D.S., M.S . Co-advisor: Asst. Prof. Wareerat Chengprapakorn,, D.D.S., Ph.D. Objective : To compare the effect on marginal bone loss between using healing abutment and customized abutment (Definite abutment). Material and method : Thirdtyfour patients who required a single posterior implant-supported prosthesis were randomly divided into two groups which were healing abutment group (Control group)and customized titanium abutment group(Test group). Patients received one dental implant between 4.0 and 5.0 mm. diameter (Dentium Superline, Dentium, Seoul, …
Comparison Of Removal Torques Among Different Abutments In Single Implant Crowns After Cyclic Loading: An In Vitro Study, Suppanut Jongsiri
Comparison Of Removal Torques Among Different Abutments In Single Implant Crowns After Cyclic Loading: An In Vitro Study, Suppanut Jongsiri
Chulalongkorn University Theses and Dissertations (Chula ETD)
Objectives: To evaluate the effect of different restoration designs on the removal torque loss of implant-supported maxillary first premolar crowns after cyclic loading and to measure the impact of cyclic loading on removal torque. Materials and Methods: Thirty-two dental implants (4.0*10 mm), embedded in resin blocks and their abutments, were divided into 4 groups (n=8) based on restoration design: screwmentable group, 2 cement-retained groups: cemented with adhesive resin cement (Panavia V5) or provisional cement (RelyX Temp NE), and screw-retained one-piece titanium group. Monolithic zirconia crowns were fabricated and cemented in the first three groups. Their removal torques were recorded using …
Comparison Of Learning Curve In Novice And Experienced Operators Between Anterior And Posterior Implant Placement Using Dynamic Computer Assisted-Surgical Implant Placement: Randomized Controlled Trials, Pitsinee Kundaechanont
Comparison Of Learning Curve In Novice And Experienced Operators Between Anterior And Posterior Implant Placement Using Dynamic Computer Assisted-Surgical Implant Placement: Randomized Controlled Trials, Pitsinee Kundaechanont
Chulalongkorn University Theses and Dissertations (Chula ETD)
Objectives: To observe the equivalence of learning curve between anterior and posterior implant placement and between novice and experienced operators using dynamic computer assisted-surgical implant placement (CAIS) with type-III bone model simulated maxilla. Materials and Methods: Eight participants, including four novices and four experienced operators, were randomly assigned in blocks to either anterior or posterior placement group. Prior to the experiment, participants underwent video-training. Each participant performed four single implant placements per session with a 7±1 days wash-out period, totaling five attempts. The operating time, coronal, depth, and angle deviations in each attempt were recorded and analyzed by a blind …
The Effect Of Water Sorption And Solubility On Surface Properties Of Cad/Cam Materials, Chatchalanya Wansudon
The Effect Of Water Sorption And Solubility On Surface Properties Of Cad/Cam Materials, Chatchalanya Wansudon
Chulalongkorn University Theses and Dissertations (Chula ETD)
The objective of this research was to examine sorption, solubility, and surface properties of three widely used CAD/CAM materials: resin composite (Cerasmart; CS), polymer-infiltrated ceramic network (Vita Enamic; VE) and lithium disilicate glass ceramic (IPS e.max CAD; LS). 45 rectangular-shaped specimens were prepared and immersed in deionized water for varying durations. These specimens were then subjected to evaluate their water sorption, solubility, surface roughness, and surface hardness. The results showed that immersion time significantly impacted water sorption of the tested materials (P.05). The 2-way ANCOVA revealed that water immersions had significant effects on surface hardness among tested CAD/CAM blocks (P.05). …
The Effect Of Universal Adhesives On Repairability Of Four Cad/Cam Blocks, Tanyaporn Treyasorasai
The Effect Of Universal Adhesives On Repairability Of Four Cad/Cam Blocks, Tanyaporn Treyasorasai
Chulalongkorn University Theses and Dissertations (Chula ETD)
This study aimed to assess the repairability among four CAD/CAM blocks repaired with different universal adhesives after aging. The CAD/CAM blocks evaluated were polymer infiltrated ceramic network (VE), zirconium-reinforced lithium silicate ceramic (VS), feldspathic ceramic (VM), and lithium disilicate ceramic (IE). Each original block was prepared to create 120 specimens. After 10,000 cycles of thermocycling, surface pretreatment of each specimen was carried out by grinding and etching with a 9% hydrofluoric acid. Subsequently, specimens were divided into three groups: Clearfil™ TRI-S BOND (CUB), Scotchbond Universal Plus® (SUP), and Monobond N® (MN). Resin composite was then applied. All samples underwent another …
Microleakage Of Class Ii Restoration Using Short-Fiber Reinforced Flowable Resin Composite, Parichat Panyawisitkul
Microleakage Of Class Ii Restoration Using Short-Fiber Reinforced Flowable Resin Composite, Parichat Panyawisitkul
Chulalongkorn University Theses and Dissertations (Chula ETD)
Objective. With short-fiber reinforced resin composite (SFRC), improved mechanical strength and good workability could be achieved within a single material. However, there remains concerns related to microleakage, which could restrict the application of this material in certain clinical situations. Materials and Methods. Class II cavities were prepared in 80 premolars. Each group, consisting of 10 specimens, was restored with different materials: flowable bulk-fill SFRC (EverX Flow, EXF), bulk-fill SFRC (EverX Posterior, EXP), flowable bulk-fill (Tetric N-Flow, TNF), and conventional resin composite (Z350 XT, Z350). The specimens were divided into two subgroups: one underwent thermocycling of 20,000 cycles, while the other …
Effect Of Variations In Translucency Of Cad/Cam Lithium-Disilicate Ceramic And Abutment Color On Optical Color Of Veneer Restoration, Wichaya Likitnuruk
Effect Of Variations In Translucency Of Cad/Cam Lithium-Disilicate Ceramic And Abutment Color On Optical Color Of Veneer Restoration, Wichaya Likitnuruk
Chulalongkorn University Theses and Dissertations (Chula ETD)
This study aimed to evaluate the optical color of different translucencies of CAD/CAM lithium-disilicate ceramics on backgrounds with different values. Low translucency (LT) and medium translucency (MT) rectangular-shaped specimens (0.6 mm thickness, shade A1) were fabricated from IPS e.max CAD (EMC; Ivoclar Vivadent) and Amber Mill (AM; HASS). Six specimens of EMC-MT, EMC-LT, AM-MT, and AM-LT were fabricated, resulting in 24 specimens in total. The specimens were placed on six background colors (1M1(reference), 1M2, 2M2, 3M2, 4M2, and 5M2) made of light-cured resin composite (Vita VM LC Base Dentine, Vita Zahnfabrik) using glycerine as a medium. The CIE L*a*b* coordinates …
Influence Of Ceramic Translucency, Ceramic Thickness, And Shades Of Luting Resin Cement On Final Color Of Cad/Cam Lithium Disilicate Veneers, Ploypailin Radeesujalitkul
Influence Of Ceramic Translucency, Ceramic Thickness, And Shades Of Luting Resin Cement On Final Color Of Cad/Cam Lithium Disilicate Veneers, Ploypailin Radeesujalitkul
Chulalongkorn University Theses and Dissertations (Chula ETD)
Purpose. To evaluate the effect of ceramic translucency, ceramic thickness, and cement color on the final optical color of a CAD/CAM lithium disilicate ceramic. Methods. A total of 180 ceramic specimens were prepared into two thicknesses, 0.5 and 1.0 mm, from high translucency (HT), medium translucency (MT), and low translucency (LT) CAD/CAM lithium disilicate ceramics (IPS e.max CAD; Ivoclar Vivadent) in shade A1. Substrates were fabricated from resin composite in shade A3. Two shades of light-cure resin cement, neutral and light plus (Variolink Esthetic LC; Ivoclar Vivadent), were used for cementation, whereas glycerine was used for the control groups. CIE …
A Comparison Of Fracture Load After Mechanical Cyclic Loading Between 3 Different Materials And 2 Designs On Implant-Supported Crown : An In Vitro Study, Thanus Liwwattanakorn
A Comparison Of Fracture Load After Mechanical Cyclic Loading Between 3 Different Materials And 2 Designs On Implant-Supported Crown : An In Vitro Study, Thanus Liwwattanakorn
Chulalongkorn University Theses and Dissertations (Chula ETD)
Objective: To compare the fracture resistance among ultra-translucent zirconia, lithium disilicate, and composite resin implant-supported maxillary premolar crowns with cement-retained or combined cement- and screw-retained designs after cyclic loading simulation. Materials and Methods: Forty-eight maxillary first premolar crowns and their abutments were attached on dental implants (ø4.0 x 10 mm) embedded in epoxy resin blocks. All specimens were equally divided into 6 groups (n=8) based on monolithic crown material (ultra-translucent zirconia (Z), lithium disilicate (L), and composite resin (C)) and restoration design (cement-retained and combined cement- and screw-retained). Each specimen was subjected to 500,000 cycles of cyclic loading. Subsequently, a …
The Comparison Of Learning Outcome Of Dental Implant Placement Training In Esthetic Zone Using Dynamic Navigation System Between Novice Dentists And Experience Dentists, Hatsapon Teparrukkul
The Comparison Of Learning Outcome Of Dental Implant Placement Training In Esthetic Zone Using Dynamic Navigation System Between Novice Dentists And Experience Dentists, Hatsapon Teparrukkul
Chulalongkorn University Theses and Dissertations (Chula ETD)
Background: The increasing importance of CAIS in the practice of implant dentistry calls for adequate education and training of clinicians, however little evidence is available to support educational strategies and best practice. Purpose: The aim of this study was to investigate the effectiveness of distributed training with d-CAIS in the accuracy of freehand implant placement by inexperienced operators. Materials and Methods: Six senior dental students without experience in implant placement and dynamic CAIS systems received simulation in free-hand implant surgery (5 implants), followed by distributed training in dynamic CAIS (6 implants). An assessment followed in freehand implant placement (5 implants). …
The Observation Of Relative Occlusal Forces Of Posterior Implant-Supported Fixed Prostheses In Tooth-Borne And Distal End Circumstance By Using T-Scan System : A Prospective Study, Jinjudhapak Thongdee
The Observation Of Relative Occlusal Forces Of Posterior Implant-Supported Fixed Prostheses In Tooth-Borne And Distal End Circumstance By Using T-Scan System : A Prospective Study, Jinjudhapak Thongdee
Chulalongkorn University Theses and Dissertations (Chula ETD)
Objectives: to assess the relative occlusal forces (ROF) of posterior implants in two different occlusion designs in tooth-borne and distal end circumstances over time using the T-scan system and to compare the marginal bone loss in those situations and designs over time. Material and methods: Twenty patients requiring single posterior or distal end implants were randomly assigned to two groups: Implant-protected occlusion (IPO) or load (LOAD). The ROFs were measured using a T-scan on five occasions. Custom-made jigs were used to collect periapical parallel x-rays. The implant platforms were used as a reference to assess marginal bone loss. Results: In …
A Comparison Of Shear Bond Strength On Human Dentin Using Acrylic Resin Cement And Self-Adhesive Resin Cements With The Use Of Universal Adhesives, Phatcha Maiwatana
A Comparison Of Shear Bond Strength On Human Dentin Using Acrylic Resin Cement And Self-Adhesive Resin Cements With The Use Of Universal Adhesives, Phatcha Maiwatana
Chulalongkorn University Theses and Dissertations (Chula ETD)
Objective: To evaluate the shear bond strength of human dentin with two different phosphate-monomer containing self-adhesive resin cements, an acrylic resin cement, and the effect of universal adhesive pretreatment on human dentin. Materials and Methods: Fifty extracted human third molars with the superficial dentin exposure at the buccal side were prepared. Resin composite cylinders with 2.38 mm diameter were cemented with 5 groups of resin cements and universal adhesives: Rely X U200, Single Bond Universal Adhesive with Rely X U200, Panavia SA Luting Multi, Clearfil Tri-S Bond Universal Quick with Panavia SA Luting Multi, and Super Bond C&B. Then, the …
Skeletal Morphology And Tooth Alignment At The Maxillary Central Incisors For Immediate Implant Placement, Wita Buranathavornsom
Skeletal Morphology And Tooth Alignment At The Maxillary Central Incisors For Immediate Implant Placement, Wita Buranathavornsom
Chulalongkorn University Theses and Dissertations (Chula ETD)
Objective: To analyze the classification of sagittal root position in maxillary central incisors and to evaluate how sagittal root position related to bone thickness, sex and age in Thai population. Methodology: Between 20 and 80 years old, a total of 308 CBCT images of the maxillary central incisor were chosen and classified into 4 classes (I-IV). On both labial and palatal sides, bone thickness was measured at the crestal, mid-root, and apex levels, as well as 4mm of bone beyond the apex. Additional measurements included bone height and the angle between dental root axis and alveolar bone axis. The difference …
Comparison Of Outcome Between Non-Submerged And Submerged Implant With Simultaneous Bone Augmentation In Esthetic Zone, Nuntapat Banomyong
Comparison Of Outcome Between Non-Submerged And Submerged Implant With Simultaneous Bone Augmentation In Esthetic Zone, Nuntapat Banomyong
Chulalongkorn University Theses and Dissertations (Chula ETD)
Objectives: To compare the dimensional changes in the buccal bone thickness of implant placement with simultaneous bone augmentation in the esthetic zone between non-submerged and submerged implants. Materials and methods: Twenty-four patients with a single edentulous area in the esthetic zone were randomly assigned into two groups which were submerged (cover screw) and non-submerged groups (healing abutment). After implant placement, the peri-implant defects were treated by simultaneous GBR. The cone-beam computed tomography (CBCT) scans were taken post-operative immediately (T0) and subsequent at 3 (T3) and 6 (T6) months after implant placement. Vertical buccal bone level (VBL) and horizontal buccal bone …
A Comparison Of Primary Stability Of Aggressive Thread Design Implant Using Two Different Technique In Different Bone Density: An In Vitro Biomechanical Study, Chandarong Huy
Chulalongkorn University Theses and Dissertations (Chula ETD)
Objective: To investigate the correlation of aggressive thread implant in different bone qualities by two systems. Materials and Methods: A single space edentulism of tooth 11 maxillary models was prepared and inserted with artificial polyurethane bone type 1-4 for the preparation site. In total, 24 implants were divided into 4 groups according to the bone types. BLX implants with 4.5mm in diameter and 12 mm in length which are considered aggressive thread implants were used in this study. All implants were digitally planned, and the preparations were performed using computer-assisted guided surgery. After implant insertion, the primary stability was measured …
Comparison Of Volumetric Changes At Implant Connector Among Three Different Types Of Abutment After Cyclic Loading, Piyawan Jirayusakamol
Comparison Of Volumetric Changes At Implant Connector Among Three Different Types Of Abutment After Cyclic Loading, Piyawan Jirayusakamol
Chulalongkorn University Theses and Dissertations (Chula ETD)
The aim of this study was to compare the volumetric change of dental implant among three different types of abutments after cyclic loading.Thirty dental implants (4.1x10 mm., Straumann®) were used .All of them were inserted in acrylic resin block with usual surgical protocol to gain primary stability and be able to retrieve for volumetric measurement later. Ten of each dental implant connected with Titanium abutment (Group1: Variobase abutment Straumann®), Gold abutment (Group2: UCLA abutment Straumann®) and Zirconia abutment (Group 3: Care abutment Straumann®) consecutively. Then all specimen was submitted to cyclic loading (1x106 cycles, axial load, 100N, 15 Hz) at …
Association Among Anterior Maxillary Dental Arch Form, Alveolar Bone Thickness And Sagittal Root Position Of Maxillary Central Incisor : A Cone Beam Computed Tomography Analysis, Suttikiat Somvasoontra
Association Among Anterior Maxillary Dental Arch Form, Alveolar Bone Thickness And Sagittal Root Position Of Maxillary Central Incisor : A Cone Beam Computed Tomography Analysis, Suttikiat Somvasoontra
Chulalongkorn University Theses and Dissertations (Chula ETD)
Purpose: This study evaluated the association among the dental arch form, age-sex groups, and sagittal root position regarding alveolar bone thickness in the maxillary central incisor using cone-beam computed tomography (CBCT) images. Materials and Methods: CBCT images of 280 patients were categorized based on the dental arch form and age-sex groups. Five hundred and sixty sagittal CBCT images of the maxillary central incisors were examined to measure the labial and palatal bone thickness at the root apex level, at the mid-root level and 3 mm apically from cemento-enamel junction, with SRP classification. Chi-square, Kruskal-Wallis test, and multiple linear regression were …
Two-Body Wear Resistance Of Four Different Lithium Disilicate, One Zirconia Reinforced Lithium Silicate, And Two Zirconia Cad/Cam Materials, Suchaya Tantrachoti
Two-Body Wear Resistance Of Four Different Lithium Disilicate, One Zirconia Reinforced Lithium Silicate, And Two Zirconia Cad/Cam Materials, Suchaya Tantrachoti
Chulalongkorn University Theses and Dissertations (Chula ETD)
Objective: to evaluate the volume loss of four different lithium disilicate, one zirconia reinforced lithium silicate, and two zirconia CAD/CAM materials. Methodology: The test conditions were divided into 8 experimental groups (n=6); Amber mill (AM), milled-Celtra Duo (mCD), fired-Celtra Duo (fCD), IPS emax CAD (EM), n!ce (NI), Rosetta SM (RS), Cercon xt (XT), and IPS emax ZirCAD (ZC). Flat square specimens (8 x8 x4 mm3) were prepared. A spherical steatite (D =6mm) was used as an antagonist. The simulated two-body wear was performed using a chewing simulator (120,000 cycles, 50 N, 1.34 Hz, sliding movement 0.5 mm). The volume loss …
Comparison Of Fracture Resistance In Different Post Systems And Fabrication Techniques In Human Endodontically Treated Tooth, Anutara Bhaktikamala
Comparison Of Fracture Resistance In Different Post Systems And Fabrication Techniques In Human Endodontically Treated Tooth, Anutara Bhaktikamala
Chulalongkorn University Theses and Dissertations (Chula ETD)
Purpose: to evaluate the fracture resistance and observe fracture mode of endodontically treated teeth restored with different post systems and fabrication techniques. Materials and Methods: Forty selected human mandibular premolars were divided into 4 groups (n=10) according to restoration after endodontic treatment: restored with prefabricated D.T. Light-Post (Group PDT), restored with D.T. Light-Post, relined with resin composite (Group ADT), restored with prefabricated Hi-Rem post (Group PHR), and restored with Hi-Rem post, relined with resin composite (Group AHR). Following cementation and core construction, specimens were loaded at a 45-degree angle in a universal testing machine until fracture. The fracture modes of …
Prevalence And Course Of Mandibular Incisive Canal In Thai Population Using Cone-Beam Computed Tomography, Wadee Sukontasing
Prevalence And Course Of Mandibular Incisive Canal In Thai Population Using Cone-Beam Computed Tomography, Wadee Sukontasing
Chulalongkorn University Theses and Dissertations (Chula ETD)
Purpose: To assess the prevalence and course of mandibular incisive canal in Thai population using cone-beam computed tomography. 149 CBCT images of the mandibles were obtained from 78 males (52.3%) and 71 females (47.7%) age ranged between 21 and 73 years. For the CBCT scan, the standard i-CAT settings were used. A digital ruler was incorporated into the viewing software for the purpose of taking measurements. Double measurements and observations were conducted by a single observer. Result: The mandibular incisive canal was identified in 90.60% of all the subject, 67 (85.89%) in males and 68 (95.77%) in females. The mean …
A Comparison Of Implant Stability Between Two Dental Implant Designusing Two Different Stability Measuring Technique, Chanikarn Chaksupa
A Comparison Of Implant Stability Between Two Dental Implant Designusing Two Different Stability Measuring Technique, Chanikarn Chaksupa
Chulalongkorn University Theses and Dissertations (Chula ETD)
Objective To investigate the primary stability of aggressive thread design implant comparing to nonaggressive thread design implant and to evaluate the correlation between ISQ values and IST values. Materials and methods 96 implants were used in this study. 48 BLT Straumann® and 48 BLX Straumann® were used. All implants were digitally planned and placed in 3D printed model using computer assisted guided surgery. The edentulous area at models were packed with randomized pattern of four different kinds of polyurethane blocks to replicate mixed cancellous bone. Postoperative implant stability measurement was performed immediately after implant insertion. Implant stability was measured by …
The Relative Occlusal Force Of Natural Tooth Adjacent To Distal Extension Implant Support Fixed Prosthesis Using T-Scan Analysis : A Cross Sectional Study, Chin Purintarapiban
The Relative Occlusal Force Of Natural Tooth Adjacent To Distal Extension Implant Support Fixed Prosthesis Using T-Scan Analysis : A Cross Sectional Study, Chin Purintarapiban
Chulalongkorn University Theses and Dissertations (Chula ETD)
Objective: This cross-sectional study aimed to compare the relative occlusal force between implant in the distal end and tooth adjacent to implant in maximum intercuspation. Methodology: Patients with implant restoration replacing teeth in free end space adjacent to natural tooth were recalled. The occlusion is examined as shim stock passes through the occluded tooth in heavy or light bites. The heavy bite or a light bite with shim stock that cannot pull through is HB1 or LB1. If the shim stock can pull through it is considered HB0 or LB0. The implant is classified into 3 groups, HB1LB0, HB1LB1, and …
Accuracy Comparison Of Dental Implants Obtained By Dynamic Cais In All-On-4 Edentulous Area Among Different Types Of Bone Density: An In Vitro Study, Jutasinee Pornpolsarun
Accuracy Comparison Of Dental Implants Obtained By Dynamic Cais In All-On-4 Edentulous Area Among Different Types Of Bone Density: An In Vitro Study, Jutasinee Pornpolsarun
Chulalongkorn University Theses and Dissertations (Chula ETD)
Background: Determination of available bone is particularly important in implant placement quality of bone can affect the accuracy implant placement. Currently, Dynamic navigation system illustrated the improvement of implant accuracy, The accuracy of implant placement using computer-assisted implant placement system (CAIS) is unknown. As a result, the goal of this study was to see how bone density affected implant placement accuracy with Dynamic CAIS. Purpose: To determine the effect of different bone density in the accuracy of implant placement using dynamic navigation system Materials and Methods: The study's overall design includes a single doctor planning each implant using a CBCT …