Open Access. Powered by Scholars. Published by Universities.®
- Institution
-
- The British University in Egypt (22)
- Association of Arab Universities (15)
- Loma Linda University (11)
- Saint Joseph University of Beirut (11)
- Universitas Indonesia (9)
-
- LSU Health New Orleans (6)
- A.T. Still University (5)
- City University of New York (CUNY) (3)
- Marquette University (3)
- Virginia Commonwealth University (3)
- West Virginia University (3)
- Beirut Arab University (2)
- Roseman University of Health Sciences (2)
- University of Connecticut (2)
- University of the Pacific (2)
- University of AlKafeel (1)
- University of Malaya (1)
- University of Nebraska - Lincoln (1)
- University of Nebraska Medical Center (1)
- Keyword
-
- Prosthodontics (10)
- Zirconia (6)
- Dental materials (4)
- PEEK (4)
- CAD/CAM (3)
-
- Implant (3)
- Sandblasting (3)
- Thermocycling (3)
- Translucency (3)
- Accuracy (2)
- Ceramic (2)
- Color (2)
- Color stability (2)
- Enamel opacity (2)
- Immediate implant placement (2)
- Modulus of elasticity (2)
- Molar incisor hypomineralization (2)
- Overdenture (2)
- Surface roughness (2)
- Surgical guide (2)
- Transillumination (2)
- 3D files (1)
- 3D printing (1)
- 3D tooth position (1)
- 3D-Printed; Color Change; Computer-Aided Design; Denture; Polymethyl Methacrylate; Staining. (1)
- Acetal (1)
- Adaptation (1)
- Additive manufacturing (1)
- Additive manufacturing Accuracy Lithium Disilicate CAD CAM (1)
- Adhesives; Aging; Composite Resin; In Vitro Tests; Mechanical Test; Tensile Strength. (1)
- Publication Year
- Publication
-
- Dentistry (22)
- Future Dental Journal (15)
- International Arab Journal of Dentistry (11)
- Loma Linda University Electronic Theses, Dissertations & Projects (11)
- Journal of Dentistry Indonesia (8)
-
- School of Dentistry Faculty Publications (6)
- MOSDOH Faculty Publications (5)
- Graduate Theses, Dissertations, and Problem Reports (ETD) (3)
- Publications and Research (3)
- Theses and Dissertations (3)
- Annual Research Symposium (2)
- BAU Journal - Creative Sustainable Development (2)
- Bachelors’ Theses (2)
- Master's Theses (2)
- Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research (1)
- Excellence Day (1)
- Maaen Journal for Medical Sciences (1)
- Makara Journal of Science (1)
- Master's Theses (2009 -) (1)
- Oral Health (1)
- Student Works (2020-2029) (1)
- Theses & Dissertations (1)
- Publication Type
Articles 1 - 30 of 103
Full-Text Articles in Dental Materials
Effect Of Home Bleaching With Carbamide Peroxide And Over-The-Counter Products On Stained Supra-Nano-Filled Composite: An In-Vitro Study., Lynn Harrouk, Pascale Habre, Samar Bou Jaoude, Carina Mehanna Zogheib
Effect Of Home Bleaching With Carbamide Peroxide And Over-The-Counter Products On Stained Supra-Nano-Filled Composite: An In-Vitro Study., Lynn Harrouk, Pascale Habre, Samar Bou Jaoude, Carina Mehanna Zogheib
International Arab Journal of Dentistry
Objective: This study evaluated the impact of home and over-the-counter (OTC) bleaching products, compliant with SCCS regulations, on color changes in tea-stained supra-nano filled composite, using the CIEDE2000 formula.
Methods: One hundred Estelite® Sigma Quick discs were fabricated, thermocycled, and tea-stained for 12 days. Samples were divided into four groups: Opalescence 15% carbamide peroxide (CP) gel, White Dental Beauty 6% hydrogen peroxide (HP) strips, Pola Luminate 6% HP brush-on gel, and a control. Color was measured at baseline, post-staining, and post-bleaching using a VITA EasyShade spectrophotometer. ΔE₀₀ values were analyzed with Kruskal-Wallis and Dunn’s post-hoc tests (p < 0.05).
Results: All bleaching …
Digital Assessment Of Subtractive And Additive Cad/Cam Fabrication Methods On The Fit And Accuracy Of Lithium Disilicate Veneers, Sara Fikry Elshafei Dr, Islam Heiba Dr, Basma Fayyad, Maha Nagy
Digital Assessment Of Subtractive And Additive Cad/Cam Fabrication Methods On The Fit And Accuracy Of Lithium Disilicate Veneers, Sara Fikry Elshafei Dr, Islam Heiba Dr, Basma Fayyad, Maha Nagy
Dentistry
No abstract provided.
Influence Of Ceramic Thickness And Cad/Cam Ceramic Materials On The Fracture Resistance Of Indirect Restorations: An In Vitro Study, Lara El Hanach, Karim Corbani, Nabil Ghosn, Ryan Harouny, Cynthia Kassis
Influence Of Ceramic Thickness And Cad/Cam Ceramic Materials On The Fracture Resistance Of Indirect Restorations: An In Vitro Study, Lara El Hanach, Karim Corbani, Nabil Ghosn, Ryan Harouny, Cynthia Kassis
International Arab Journal of Dentistry
Objectives: This in-vitro study aimed to evaluate the impact of different CAD/CAM materials (IPS e.max® CAD and Cerasmart®) and thicknesses (0.7 mm, 1 mm, and 1.5 mm) on the fracture resistance of indirect overlay restorations.
Methods: Sixty-three human third molars were divided into 7 groups (n=9) based on material and thickness, including a control group of 9 sound teeth. Only 54 specimens were prepared using a thin-section cutting machine, scanned, and their scans were used to fabricate overlays from different materials and thicknesses. After adhesive cementation, the overlays underwent thermal cyclic loading (5,000 cycles between 5°C and 55°C). A universal …
Effect Of Dynamic Fatigue Loading On The Adaptation And Retention Of Maxillary Single Dentures Reinforced With Digitally Constructed Zirconia And Cobalt–Chromium Frameworks, Ghada Elgindy, Fardos N Rizk, Marwa Ezzat Sabet, Hebatallah Tarek Mohamed
Effect Of Dynamic Fatigue Loading On The Adaptation And Retention Of Maxillary Single Dentures Reinforced With Digitally Constructed Zirconia And Cobalt–Chromium Frameworks, Ghada Elgindy, Fardos N Rizk, Marwa Ezzat Sabet, Hebatallah Tarek Mohamed
Dentistry
Background. The impact of dynamic fatigue loading on denture adaptation and retention is clinically important. Zirconia and cobalt–chromium (Co–Cr) frameworks enhance denture strength, but their performance under cyclic loading remains unclear. Objectives. The aim of the study was to evaluate the adaptation and retention of maxillary single dentures reinforced with digitally constructed Co–Cr or zirconia frameworks after a simulated 1 year of function. Material and methods. Three types of maxillary single dentures were constructed on maxillary master casts. Group A included maxillary dentures without reinforcement (control group), whereas groups B and C encompassed maxillary dentures reinforced with digitally designed and …
The Effect Of Cementation Load, Unload Time And Storage Time On Film Thickness And Μtbs Durability Of Dual-Cure Resin Cements. An In-Vitro Study, Sara Adel Botros, Abdullah Hassanien, Nader Maher Tadros, Farid Sabry El-Askary, Salvatore Sauro
The Effect Of Cementation Load, Unload Time And Storage Time On Film Thickness And Μtbs Durability Of Dual-Cure Resin Cements. An In-Vitro Study, Sara Adel Botros, Abdullah Hassanien, Nader Maher Tadros, Farid Sabry El-Askary, Salvatore Sauro
Dentistry
No abstract provided.
Comparing Educational Pathways For Denturists To Become Maxillofacial Prosthetic Specialists In The Us And The Uk, Minseok Kim
Comparing Educational Pathways For Denturists To Become Maxillofacial Prosthetic Specialists In The Us And The Uk, Minseok Kim
Oral Health
Abstract
In the absence of formal training, licensure, and professionalism, this scientific literature review will seek to include denturists in the American maxillofacial prosthetics industry. Denturists are oral health professionals who perform oral examination, design, manufacture, and place removable oral prostheses. In other regions of the world, they are also known as clinical dental technologists and dental prosthetists. This practice is not widespread in the US. The review can also be assessed on the model mediated by PRISMA, which is concentrated on the experiences of international education in the United Kingdom, Canada, and Australia, where the concentration further revolves around …
Endodontic Access Through Zirconia Crowns: A Comparative Evaluation Of 3d Guided Versus Free-Handed Techniques, Maryam Alrughaib
Endodontic Access Through Zirconia Crowns: A Comparative Evaluation Of 3d Guided Versus Free-Handed Techniques, Maryam Alrughaib
Theses and Dissertations
Objective:
Accessing canals through full-coverage zirconia crowns is challenging and may increase the risk of misdirection, excessive dentin removal, and prolonged chair time. Guided endodontic access has been proposed to improve efficiency and precision. This study compared the accuracy and time efficiency of guided versus free-hand endodontic access through zirconia restorations. The hypothesis was that guided access would enhance canal localization precision and significantly reduce access time.
Methods:
Thirty-two extracted maxillary premolars were restored with 1-mm–reduced monolithic zirconia crowns (3Y-TZP, Katana HTML, Kuraray, Japan) and mounted in Modupro models. Teeth were assigned to two groups (n = 16 each): guided …
Effect Of Different Deep Margin Elevation Thicknesses Versus No Elevation On The Fracture Resistance Of Indirect Restorations: An In-Vitro Study, Fleurene Daraze, Karim Corbani, Brigitte Douaihy, Hadi Jomaah, Cynthia Kassis
Effect Of Different Deep Margin Elevation Thicknesses Versus No Elevation On The Fracture Resistance Of Indirect Restorations: An In-Vitro Study, Fleurene Daraze, Karim Corbani, Brigitte Douaihy, Hadi Jomaah, Cynthia Kassis
International Arab Journal of Dentistry
Objectives: This in-vitro study aimed to evaluate whether different deep margin elevation (DME) thicknesses (1 mm, 2 mm, 3 mm) influence the fracture resistance and fracture type of molars restored with CAD/CAM lithium disilicate overlays, compared to no elevation.
Methods: Seventy-six extracted human molars were randomly divided into four groups (n=19) based on Deep Margin Elevation thickness: 0 mm (control), 1 mm, 2 mm, and 3 mm. Standardized Class II cavities were prepared with cervical margins extending 1 mm below the cementoenamel junction. DME was performed using a low-viscosity hybrid composite. Using a CAD/CAM workflow, overlays were designed and milled …
Impact Of Adhesive Curing Mode And Dentin Sealing On Bond Strength Of Cad/Cam Resin Composite, Sara Adel Botros, Mohamed Fouad Haridy, Nermin Mohieldin Abdelmohssen
Impact Of Adhesive Curing Mode And Dentin Sealing On Bond Strength Of Cad/Cam Resin Composite, Sara Adel Botros, Mohamed Fouad Haridy, Nermin Mohieldin Abdelmohssen
Dentistry
No abstract provided.
Effect Of Acid-Containing Drinks On Surface Roughness And Bacterial Accumulation Of Different Types Of Denture Base Materials, Sara Fikry Dr, Ayman Amin, Eman Khedr, Fatma Makkeya
Effect Of Acid-Containing Drinks On Surface Roughness And Bacterial Accumulation Of Different Types Of Denture Base Materials, Sara Fikry Dr, Ayman Amin, Eman Khedr, Fatma Makkeya
Dentistry
No abstract provided.
Effect Of Margin Thickness And Cement Gap On The Fabrication And Fit Accuracy Of Additively Manufactured Crowns In Definitive Resins With Different Filler Content, Mustafa Borga Dönmez, Gülce Çakmak, Çiğdem Kahveci, Amir H. Nejat, Burak Yilmaz, Pinar Altinci
Effect Of Margin Thickness And Cement Gap On The Fabrication And Fit Accuracy Of Additively Manufactured Crowns In Definitive Resins With Different Filler Content, Mustafa Borga Dönmez, Gülce Çakmak, Çiğdem Kahveci, Amir H. Nejat, Burak Yilmaz, Pinar Altinci
School of Dentistry Faculty Publications
PURPOSE: To evaluate how commercially available composite resins in varying filler content affect the fabrication and fit accuracy (trueness and precision) of additively manufactured (AM) definitive crowns with different margin thickness and cement gaps by comparing them to subtractively manufactured (SM) polymer-infiltrated ceramic crowns. MATERIALS AND METHODS: Two identical unprepared mandibular right first molars were prepared by an experienced prosthodontist for crowns with either 0.5 mm or 1.0 mm chamfer margins, verified using silicone indexes and a periodontal probe, and then digitized with an industrial-grade scanner. These scan files were used to design reference crowns with either 50-µm or 80-µm …
Evaluation Of Marginal And Internal Fit In Cad/Cam-Fabricated Indirect Restorations, Sara Adel Botros, Mohamed Samy Salama, Hend Sayed Ahmed, Ayman Helmy
Evaluation Of Marginal And Internal Fit In Cad/Cam-Fabricated Indirect Restorations, Sara Adel Botros, Mohamed Samy Salama, Hend Sayed Ahmed, Ayman Helmy
Dentistry
No abstract provided.
Bond Strength Of Thermally Aged Cad/Cam Hybrid Nanoceramic Repaired With Nanohybrid Resin Composite, Mostafa Aboushahba, Sara H. Younis
Bond Strength Of Thermally Aged Cad/Cam Hybrid Nanoceramic Repaired With Nanohybrid Resin Composite, Mostafa Aboushahba, Sara H. Younis
Future Dental Journal
Purpose. To assess shear bond strength (SBS) of nanohybrid resin composite used to repair CAD/CAM Hybrid Nanoceramic ceramic after various surface treatments.
Materials and Methods. SHOFU HC Hybrid Ceramic disks were sliced to obtain circular-shaped specimens (n= 30) were obtained. All specimens were thermocycled (5000 thermal cycles), then specimens were divided into three groups according to the surface treatment performed (sandblasting, HF acid etching, and laser irradiation) (n = 10). Repair procedure with nanohybrid resin composite was performed. SBS values were obtained, and failure modes were determined. Data were statistically analyzed (P ≤ 0.05). Results. The highest SBS …
Effect Of Smoking And Finishing And Polishing Protocol On Color Stability And Surface Roughness Of Resin Composite, Fatma Makkeyah, Mohamed Samy Salama, Sara Adel Botros, Mohamed Shamel, Mahmoud Al Ankily
Effect Of Smoking And Finishing And Polishing Protocol On Color Stability And Surface Roughness Of Resin Composite, Fatma Makkeyah, Mohamed Samy Salama, Sara Adel Botros, Mohamed Shamel, Mahmoud Al Ankily
Dentistry
Purpose To investigate the influence of smoking and finishing and polishing protocol on color stability and surface roughness of resin composite. Materials and methods Seventy-two discs fabricated from supra-nanofilled composite were divided to 6 groups according to: Tobacco Product (Conventional Cigarette/CS and Heated Tobacco/HTP); and Finishing and Polishing Protocol (Control/C, Multi-step finishing system/FS, and Medium-grit abrasive bur + two-step polishing system/ PS). After finishing and polishing, specimens were exposed to a total of 600 cigarettes, divided into 20 each day, simulating 30 days of smoking. Color parameters were detected using a spectrophotometer. Surface roughness (Ra) was measured before and after …
Effect Of Load Removal On Bonding Of Resin Cement To Cad/Cam Composite, Sara Adel Botros, Farid Sabry El-Askary, Nader Maher Tadros, Abdallah Hassanien, Salvatore Sauro
Effect Of Load Removal On Bonding Of Resin Cement To Cad/Cam Composite, Sara Adel Botros, Farid Sabry El-Askary, Nader Maher Tadros, Abdallah Hassanien, Salvatore Sauro
Dentistry
No abstract provided.
Evaluation Of Marginal And Internal Fit In Cad/Cam-Fabricated Indirect Restorations, Mohamed Salama, Sara Adel Botros, Hend Sayed Ahmed
Evaluation Of Marginal And Internal Fit In Cad/Cam-Fabricated Indirect Restorations, Mohamed Salama, Sara Adel Botros, Hend Sayed Ahmed
Dentistry
Objectives: This study investigated the effect of marginal adaptation and internal fit of premolar teeth restored with indirect overlays, fabricated from different CAD/CAM materials (lithium-disilicate and composite blocks). Materials and Methods: Twenty-two intact premolars with standardized concave chamfer overlay preparation were divided into two groups (n= 18) Group (A): lithium disilicate blocks and Group (B): composite blocks. All groups cemented with dual cured resin cement. After 24h of storage at 37°C followed by thermocycling. Marginal gap evaluation evaluated using a stereomicroscope at x50 magnification at 4 points at each surface. Specimens were then sectioned mesiodistally to assess internal fit. Statistical …
Evaluation Of Microtensile Bond Strength Of Composite Under Three Aging Conditions: A Comparative In Vitro Study, Fadi Hammoud, Louis Hardan, Maryse Nassif, Tala El Ghoul, Georges Najjar, Cynthia Kassis
Evaluation Of Microtensile Bond Strength Of Composite Under Three Aging Conditions: A Comparative In Vitro Study, Fadi Hammoud, Louis Hardan, Maryse Nassif, Tala El Ghoul, Georges Najjar, Cynthia Kassis
International Arab Journal of Dentistry
Objectives: To investigate the effects of different in-vitro artificial aging protocols on the micro tensile bond strength (µTBS) of composite restorations applied to dentin.
Methods: A total of 88 teeth were prepared on dentin and divided into three distinct aging conditions and a control group : G1) Control group with no aging (n=22); G2) Thermal Cycling (Thermocycling) involving 10,000 cycles between 5°C and 55°C, with a dwell time of 20 seconds (n=22); G3) Mechanical Loading (Cyclic loading) with a 50 N load, a frequency of 1.5 Hz, and 10,000 cycles (n=22); G4) Combined Thermo-mechanical cyclic loading (TMCL) using …
Color Stability Of Conventional, 3d-Printed, And Milled Denture Teeth After Immersion In Coloring Agents: An In Vitro Study, Dany Nassif, Nancy Chemaly, Rim Bourgi, Carole Abi-Ghosn, Louis Hardan, Jihad Fakhouri
Color Stability Of Conventional, 3d-Printed, And Milled Denture Teeth After Immersion In Coloring Agents: An In Vitro Study, Dany Nassif, Nancy Chemaly, Rim Bourgi, Carole Abi-Ghosn, Louis Hardan, Jihad Fakhouri
International Arab Journal of Dentistry
Objectives: This study investigates the color stability of denture teeth made from different materials when subjected to various staining solutions.
Methods: Forty-five A1 shade upper central incisors were divided into three groups: prefabricated, 3D printed, and milled denture teeth (N=45). Each group was further divided into three subgroups, with teeth immersed in coffee, wine, and artificial saliva for up to 120 days (n=5). ∆E values for color change were measured using an Optishade colorimeter.
Results: The type of teeth, type of solution, and immersion time had a significant effect on color stability (p < 0.001). Interactions between the three variables were all significant (p < 0.001). Conventional denture teeth showed slight color changes with saliva (ΔE = 1.256 by day 120), moderate changes with wine (ΔE = 2.893), and more significant changes with coffee (ΔE = 5.208). Milled denture teeth exhibited no color changes with saliva, noticeable changes with wine (ΔE = 5.359), and moderate changes with coffee (ΔE = 3.137). 3D printed denture teeth showed no color changes with saliva, but increased changes with wine (ΔE = 2.533) and highly significant changes with coffee (ΔE = 10.546). Coffee consistently caused the highest ΔE values, especially in 3D printed teeth.
Conclusions: The study …
Comparative Evaluation Of Marginal And Internal Fit Of Zirconia Crown Designed Using Artificial Intelligence And Cad-Cam Software: A Systematic Review, Pritesh Gangde, Sweta Kale Pisulkar, Arushi Beri, Pritam Das
Comparative Evaluation Of Marginal And Internal Fit Of Zirconia Crown Designed Using Artificial Intelligence And Cad-Cam Software: A Systematic Review, Pritesh Gangde, Sweta Kale Pisulkar, Arushi Beri, Pritam Das
International Arab Journal of Dentistry
Introduction: The long-term performance of dental restorations depends on their internal and marginal fits. Improvements in the fit of restorations, especially zirconia crowns, have been investigated through the use of diverse materials, manufacturing processes, and impression techniques.
Objectives: The purpose of this review was to examine the internal and marginal fit of zirconia crowns made with CAD/CAM software with artificial intelligence (AI) software.
Methods: Using a combination of keywords and MeSH terms, the literature search was carried out across seven databases: PubMed, Scopus, Web of Science, Cochrane Library, Embase, ProQuest, and ScienceDirect from inception till 1st of …
Effect Of Build Orientation On The Fabrication Trueness Of Additively Manufactured Implant-Supported Complete Arch Interim Fixed Prostheses, Amir H. Nejat, Mehmet Esad Güven, Gülce Çakmak, Burak Yilmaz, Mustafa Borga Donmez
Effect Of Build Orientation On The Fabrication Trueness Of Additively Manufactured Implant-Supported Complete Arch Interim Fixed Prostheses, Amir H. Nejat, Mehmet Esad Güven, Gülce Çakmak, Burak Yilmaz, Mustafa Borga Donmez
School of Dentistry Faculty Publications
PURPOSE: To evaluate how build orientation affects the fabrication trueness of additively manufactured implant-supported complete arch prostheses by comparing them to subtractively manufactured high-impact polymer-based prostheses. MATERIALS AND METHODS: An edentulous maxillary model with four implants at canine and first molar regions bilaterally was digitized (ATOS Core 80 5MP) to design a reference implant-supported complete arch prosthesis standard tessellation language file (RF-STL). The STL file was used to manufacture prostheses additively in five different orientations according to the build platform (AM-0, 0-degree; AM-15, 15-degree; AM-30, 30-degree; AM-45, 45-degree; AM-90, 90-degree) or subtractively (SM-HIP, control) (n = 10). The prostheses were …
Resin-Build-Up As A Direct Monoblock Concept For Root Canal Dentin, Core, And Crown Restoration On Anterior Endodontically Treated Tooth, Citra Kusumasari, Takashi Hatayama, Junji Tagami, Yasushi Shimada Prof.
Resin-Build-Up As A Direct Monoblock Concept For Root Canal Dentin, Core, And Crown Restoration On Anterior Endodontically Treated Tooth, Citra Kusumasari, Takashi Hatayama, Junji Tagami, Yasushi Shimada Prof.
Journal of Dentistry Indonesia
The long-term clinical performance of restoration in endodontically treated teeth (ETT) is an essential yet complicated strategy to achieve it. A resin-build-up tooth with higher elastic moduli is a minimally invasive strategy to decrease the risk of catastrophic root fracture. Additionally, intracanal resin composite anchorage simplifies the restorative procedure and increases the bonding. Objective: This case report describes a resin-build-up tooth restoration using the direct monoblock concept to replace a failed metal post and core and porcelain fused to metal (PFM) crown on the maxillary right central incisor. Case report: A 50-year-old man attended a dental university hospital …
Minimally Invasive Treatment Of Molar Incisor Hypomineralization Without Using Burs: Experiences Via A Case Series In Vietnam, Võ Truong Nhu Ngoc, Nguyen Phương Huyen, Le Khả Anh, Phan Thi Thu Hang, Hoang Kim Loan, Ta Thành Dong
Minimally Invasive Treatment Of Molar Incisor Hypomineralization Without Using Burs: Experiences Via A Case Series In Vietnam, Võ Truong Nhu Ngoc, Nguyen Phương Huyen, Le Khả Anh, Phan Thi Thu Hang, Hoang Kim Loan, Ta Thành Dong
Journal of Dentistry Indonesia
Mild form of molar-incisor hypomineralization (MIH) on anterior teeth are posing great challenges to dental practitioners as it can have a huge aesthetic impact. In terms of deep MIH-related lesion below the healthy enamel, highly invasive methods for approaching the lesion body and removing the entire hypomineralized enamel using burs could lead to failures including aesthetic problems and even further tooth structure damage to the affected teeth. Case report: To resolve t his issue, we have proposed a modified resin infiltration technique based on the minimally invasive philosophy. In this study, we would like to report three specific cases …
Clinical Features Of Anterior Teeth Affected By Molar Incisor Hypomineralization And Treatment Experiences Using Transilluminated Light: A Cross-Sectional Study, Phạm Thanh Ha, Nguyễn Phương Huyen, Phạm Kim Thanh, Lương Minh Hang, Trần Tuấn Anh, Võ Như Trương Ngoc, Lê Khả Anh, Trần Anh Tuan, Tạ Thành Dong
Clinical Features Of Anterior Teeth Affected By Molar Incisor Hypomineralization And Treatment Experiences Using Transilluminated Light: A Cross-Sectional Study, Phạm Thanh Ha, Nguyễn Phương Huyen, Phạm Kim Thanh, Lương Minh Hang, Trần Tuấn Anh, Võ Như Trương Ngoc, Lê Khả Anh, Trần Anh Tuan, Tạ Thành Dong
Journal of Dentistry Indonesia
Classification and resin infiltration treatment of MIH-related permanent anterior teeth are increasingly receiving attention nowadays. Objective: The study aims to evaluate the characteristics of these teeth; and to assess factors regarding treatment. Methods: A cross-sectional study was conducted using transilluminated and reflected light photographs, and the lesion was classified according to its color, size, type, heterogeneity and surface integrity. The data were analyzed using a chi-square test and multivariate logistic regression analysis to evaluate enamel craze lines (ECL), post-eruptive breakdown (PEB), and treatment procedures. Results: 73 teeth from 46 patients were included, in which 53 teeth had been treated. Size …
Efect Of Conventional Cigarette Smoking And Recent Heated Tobacco Products On Cad/ Cam Restorative Materials, Fatma Makkeyah, Omar Elsergany, Mohamed Shamel, Mahmoud Al Ankily
Efect Of Conventional Cigarette Smoking And Recent Heated Tobacco Products On Cad/ Cam Restorative Materials, Fatma Makkeyah, Omar Elsergany, Mohamed Shamel, Mahmoud Al Ankily
Dentistry
No abstract provided.
The Effect Of Using Two Sintering Cycles On The Optical Properties Of Gradient Multi-Layered Zirconia (In Vitro Study), Fatma Makkeyah, Passent Elghalab, Maged Zohdy, Mostafa Nour
The Effect Of Using Two Sintering Cycles On The Optical Properties Of Gradient Multi-Layered Zirconia (In Vitro Study), Fatma Makkeyah, Passent Elghalab, Maged Zohdy, Mostafa Nour
Dentistry
No abstract provided.
The Effect Of Preparation Design And Thermal Cycling On The Marginal Accuracy Of Hybrid Ceramic Laminate Veneers, Esraa El Bably, Ossama Saleh Abdelghany, Mostafa Aboushahba, Shereen Ahmed Nossair
The Effect Of Preparation Design And Thermal Cycling On The Marginal Accuracy Of Hybrid Ceramic Laminate Veneers, Esraa El Bably, Ossama Saleh Abdelghany, Mostafa Aboushahba, Shereen Ahmed Nossair
Future Dental Journal
Aim: This study investigated the effect of preparation design and thermal cycling on the marginal accuracy of hybrid ceramic laminate veneers. Materials and Methods: A total of twenty 3D printed dies of central incisors prepared with 2 preparation designs; butt joint and palatal wrap design were fabricated. Each type of preparation was assigned into 2 subgroups (n=5/each subgroup) according to the type of material used for fabrication of the laminate veneer; hybrid ceramic and lithium disilicate (served as control). Marginal discrepancy was evaluated using a digital microscope before and after thermocycling. Results: Statistically analysis of marginal gaps revealed that before …
Measuring Accuracy Of Dolphin Imaging Software In Predicting Upper Jaw Soft Tissue Profile Changes In Class Ii Adult Patients Treated With Extraction Versus Non-Extraction., Amr Amin Arif, Esam Nasef, Amira Aboalnaga
Measuring Accuracy Of Dolphin Imaging Software In Predicting Upper Jaw Soft Tissue Profile Changes In Class Ii Adult Patients Treated With Extraction Versus Non-Extraction., Amr Amin Arif, Esam Nasef, Amira Aboalnaga
Future Dental Journal
Abstract
Objective: To assess the accuracy of Dolphin Imaging software in predicting upper jaw profile changes in class II patients treated by extraction and non-extraction.
Methods: The records of 60 Class II div 1 patients were selected; 30 patients treated by extraction of upper first premolar and 30 patients treated by non-extraction. The Pre- and post-treatment lateral cephalometric x-rays of each patient were traced using Dolphin software. The actual hard tissue changes due to treatment were calculated and installed into the prediction module to generate the predicted profile. The soft tissue measurements of the actual post-treatment and predicted profiles were …
The Effect Of Die Material On The Crown Fracture Strength Of Zirconia Crowns, Akram Sayed Ahmed, Nathaniel C. Lawson, Chin-Chuan Fu, Pranit V. Bora, Edwin Kee, Amir H. Nejat
The Effect Of Die Material On The Crown Fracture Strength Of Zirconia Crowns, Akram Sayed Ahmed, Nathaniel C. Lawson, Chin-Chuan Fu, Pranit V. Bora, Edwin Kee, Amir H. Nejat
School of Dentistry Faculty Publications
BACKGROUND: Determination of the eligibility of several tooth analog materials for use in crown fracture testing. METHODS: A standardized premolar crown preparation was replicated into three types of resin dies (C&B, low modulus 3D printed resin; OnX, high modulus 3D printed resin composite; and highest modulus milled resin composite). 0.8 mm zirconia crowns were bonded to the dies and the maximum fracture load of the crowns was tested. Twelve extracted human premolars were prepared to a standardized crown preparation, and duplicate dies of the prepared teeth were 3D printed out of C&B. Zirconia crowns were bonded to both the dies …
Alginate Dressings- Revisiting The Past, Oshine Jha, Oshine Jha
Alginate Dressings- Revisiting The Past, Oshine Jha, Oshine Jha
Annual Research Symposium
Wound healing in simple terms is the healing of skin which involves various mechanisms. It is not dressings themselves that heal wounds, but the careful selection of appropriate dressings that provide the optimal wound-healing environment for the individual wound. Wound dressings are prepared from biopolymers, synthetic polymers and biomaterials.
Clinical, Radiographic And Biochemical Evaluation Of One-Piece Vs Two-Piece Single Implants After 5 Years Of Functional Loading, Ippolito Caputo
Clinical, Radiographic And Biochemical Evaluation Of One-Piece Vs Two-Piece Single Implants After 5 Years Of Functional Loading, Ippolito Caputo
Annual Research Symposium
The aim of this study was to compare the clinical and radiographic conditions and the expression of proinflammatory cytokines in peri-implant crevicular fluid (PICF) of two-piece/bone level (TP/BL) versus one-piece/tissue level (OP/TL) single implants with a laser-microgrooved collar after at least 5 years of functional loading.