Open Access. Powered by Scholars. Published by Universities.®
- Discipline
- Keyword
-
- Prosthodontics (10)
- Orthodontics (5)
- Restorative Dentistry (5)
- Oral and Maxillofacial Surgery (4)
- Translucency (4)
-
- PEEK (3)
- Thermocycling (3)
- Endodontics (2)
- Glass Ionomer (2)
- Pediatric dentistry (2)
- Periodontics (2)
- Surgical guide (2)
- Thickness (2)
- (CBCT) (1)
- 0.018 vs 0.022 inch slot brackets (1)
- Accuracy (1)
- Acetal (1)
- Aging (1)
- Alignment (1)
- Allogenic bone blocks (1)
- And OHRQoL. (1)
- Antibacterial (1)
- Antibacterial efficiency (1)
- Bioceramic sealer (1)
- Bond Strength (1)
- CAD/CAM. (1)
- Caries-affected Dentin (1)
- Carious Class V (1)
- Ceramic (1)
- Childhood Caries (1)
Articles 1 - 30 of 37
Full-Text Articles in Dental Materials
Evaluation Of Glass Ionomer With Advanced Glass Hybrid Technology Versus Resin Modified Glass Ionomer In Adult Patients With Carious Cervical Lesions After One Year: A Randomized Clinical Trial., Aya Magdy Zayed, ِAhmed Zoheir El Hoshy, Mohamed Refaat El-Bialy
Evaluation Of Glass Ionomer With Advanced Glass Hybrid Technology Versus Resin Modified Glass Ionomer In Adult Patients With Carious Cervical Lesions After One Year: A Randomized Clinical Trial., Aya Magdy Zayed, ِAhmed Zoheir El Hoshy, Mohamed Refaat El-Bialy
Future Dental Journal
Aim: Compared the clinical performance by using Advanced Glass Hybrid technology glass ionomer (AGH) in cervical carious lesion, versus resin modified glass ionomer (RMGI) according to modified USPHS criteria over one year. Materials and methods: An overall of 32 elevated carious index adult patients with at least one carious class V cavity on their posterior teeth had been split into 2 equal groups randomly based on the received restoration system. Two pairs of restorations were used, either; Equia Forte HT Fill (AGH) or Fuji II LC (RMGI), both materials were employed in accordance with the manufacturer's guidelines. Fillings have …
Bond Strength Of Thermally Aged Cad/Cam Hybrid Nanoceramic Repaired With Nanohybrid Resin Composite, Mostafa Aboushahba, Sara H. Younis
Bond Strength Of Thermally Aged Cad/Cam Hybrid Nanoceramic Repaired With Nanohybrid Resin Composite, Mostafa Aboushahba, Sara H. Younis
Future Dental Journal
Purpose. To assess shear bond strength (SBS) of nanohybrid resin composite used to repair CAD/CAM Hybrid Nanoceramic ceramic after various surface treatments.
Materials and Methods. SHOFU HC Hybrid Ceramic disks were sliced to obtain circular-shaped specimens (n= 30) were obtained. All specimens were thermocycled (5000 thermal cycles), then specimens were divided into three groups according to the surface treatment performed (sandblasting, HF acid etching, and laser irradiation) (n = 10). Repair procedure with nanohybrid resin composite was performed. SBS values were obtained, and failure modes were determined. Data were statistically analyzed (P ≤ 0.05). Results. The highest SBS …
Success Of Early Childhood Caries After Treatment With Silver Diamine Fluoride Compared To Conventional Glass Ionomer Restoration. A Systematic Review, Sara H. Younis, Afnan M. Elkordy, Nouran M. Alshazly
Success Of Early Childhood Caries After Treatment With Silver Diamine Fluoride Compared To Conventional Glass Ionomer Restoration. A Systematic Review, Sara H. Younis, Afnan M. Elkordy, Nouran M. Alshazly
Future Dental Journal
Abstract
Aim: To compare the success rate regarding esthetics, parenteral satisfaction, and oral health related quality of life (OHRQoL) after treatment of early childhood caries with Silver Diamine Fluoride (SDF)compared to conventional Glass ionomer Restoration (CGI).
Materials and Methods: We conducted a systematic review following PRISMA statement by searching on the following electronic databases: PubMed, Cochrane.
Results: From the studies included in this systematic review, two studies showed significant difference in color stability between SDF and CGI. Two studies showed no significant difference in parental satisfaction with either SDF or Glass Ionomer. Regarding the Oral Health Related Quality of Life, …
The Effect Of Preparation Design And Thermal Cycling On The Marginal Accuracy Of Hybrid Ceramic Laminate Veneers, Esraa El Bably, Ossama Saleh Abdelghany, Mostafa Aboushahba, Shereen Ahmed Nossair
The Effect Of Preparation Design And Thermal Cycling On The Marginal Accuracy Of Hybrid Ceramic Laminate Veneers, Esraa El Bably, Ossama Saleh Abdelghany, Mostafa Aboushahba, Shereen Ahmed Nossair
Future Dental Journal
Aim: This study investigated the effect of preparation design and thermal cycling on the marginal accuracy of hybrid ceramic laminate veneers. Materials and Methods: A total of twenty 3D printed dies of central incisors prepared with 2 preparation designs; butt joint and palatal wrap design were fabricated. Each type of preparation was assigned into 2 subgroups (n=5/each subgroup) according to the type of material used for fabrication of the laminate veneer; hybrid ceramic and lithium disilicate (served as control). Marginal discrepancy was evaluated using a digital microscope before and after thermocycling. Results: Statistically analysis of marginal gaps revealed that before …
Comparison Of Alignment Duration Between 0.018” And 0.022” Slot Brackets In Non-Extraction Orthodontic Adult Patients: (A Randomized Clinical Study), Omar Hazem Abouwafia, Hala Munir Abdel Majeed, Mona Salah Fayed, Nouran Fouad Seif-Eldin
Comparison Of Alignment Duration Between 0.018” And 0.022” Slot Brackets In Non-Extraction Orthodontic Adult Patients: (A Randomized Clinical Study), Omar Hazem Abouwafia, Hala Munir Abdel Majeed, Mona Salah Fayed, Nouran Fouad Seif-Eldin
Future Dental Journal
Abstract:
Introduction: Orthodontist tend to use one of the 2 bracket slot sizes available either the 0.018” or 0.022” bracket slot. Till now there is no reliable scientific evidence that indicates if any of them has a superior effect on the duration of teeth alignment. The aim of this study is to compare alignment duration between 0.018 and 0.022-inch bracket slot systems.
Subjects and methods: 14 Eligible participants having an age range of 14-22 years were randomly allocated to 2 groups (7 in each group). Group I: 0.018-inch and Group II: 0.022-inch slot (American orthodontics Mini master Roth prescription …
Comparison Between Orthodontic Measurements Taken From Cone-Beam Computed Tomography (Cbct) And Digital Models After Enmasse Retraction In Orthodontic Patients With Maxillary Protrusion., Amr M. Attia, Amr R. El-Beialy, Heba M. Dehis, Yehya A. Moustafa
Comparison Between Orthodontic Measurements Taken From Cone-Beam Computed Tomography (Cbct) And Digital Models After Enmasse Retraction In Orthodontic Patients With Maxillary Protrusion., Amr M. Attia, Amr R. El-Beialy, Heba M. Dehis, Yehya A. Moustafa
Future Dental Journal
ABSTRACT
Objectives: This study aimed to evaluate the accuracy and reliability in measuring anchorage loss, molar rotation, and total amount of retraction using cone beam computed tomography (CBCT) and to compare them with the same measurements obtained using digitally scanned dental models. Materials and methods: 24 patients requiring comprehensive orthodontic treatment including extraction of 1st premolars with maximum anchorage using enmasse retraction. CBCTs were undertaken on the same 24 patients using InVivoDental software for measurement. The digital cast was made using alginate impressions, from which virtual 3D models will be created and measured using 3Shape analyzer software. Orthodontic measurements will …
Measuring Accuracy Of Dolphin Imaging Software In Predicting Upper Jaw Soft Tissue Profile Changes In Class Ii Adult Patients Treated With Extraction Versus Non-Extraction., Amr Amin Arif, Esam Nasef, Amira Aboalnaga
Measuring Accuracy Of Dolphin Imaging Software In Predicting Upper Jaw Soft Tissue Profile Changes In Class Ii Adult Patients Treated With Extraction Versus Non-Extraction., Amr Amin Arif, Esam Nasef, Amira Aboalnaga
Future Dental Journal
Abstract
Objective: To assess the accuracy of Dolphin Imaging software in predicting upper jaw profile changes in class II patients treated by extraction and non-extraction.
Methods: The records of 60 Class II div 1 patients were selected; 30 patients treated by extraction of upper first premolar and 30 patients treated by non-extraction. The Pre- and post-treatment lateral cephalometric x-rays of each patient were traced using Dolphin software. The actual hard tissue changes due to treatment were calculated and installed into the prediction module to generate the predicted profile. The soft tissue measurements of the actual post-treatment and predicted profiles were …
Smear Layer Removal Using Two Different Ni-Ti Instruments With Two Different Irrigating Systems. An Invitro Study, Tasneem Mohamed Reyad, Wael Ahmed Hessein, Ahmed Abdelrahman Hashem Ah, Said Abd Elhafiz
Smear Layer Removal Using Two Different Ni-Ti Instruments With Two Different Irrigating Systems. An Invitro Study, Tasneem Mohamed Reyad, Wael Ahmed Hessein, Ahmed Abdelrahman Hashem Ah, Said Abd Elhafiz
Future Dental Journal
Objectives: To evaluate and compare smear layer removal in root canals instrumented with two single Ni-Ti rotary instruments with two different irrigating systems. Materials and Methods: Sixty recently extracted single-rooted mandibular premolars teeth were decoronated to a standardized length of 14 mm. Roots were divided into two main groups (n=30) according to the rotary NiTi file used for instrumentation either with One Shape (OS) file or with One Curve file (OC). Each main group was subdivided into three subgroups according to the methods used to agitate the irrigating solutions either sonically or ultrasonically as following: Group A was subdivided into …
Effect Of Different Implant Materials On Stresses Transmitted To Peri-Implant Areas Of Implant-Retained Mandibular Overdenture, Diaa Mohamed Zahran Future University In Egypt, [email protected], Aya Fawzy Associate Professor Of Prosthodontics, Future University In Egypt, [email protected], Salah Hegazy Professor Of Prosthodontics, Faculty Of Dentistry, Mansoura University, [email protected], Sara M. Shabaan Lecturer At Removable Prosthodontic Department, Faculty Of Oral And Dental Medicine , Badr University, Cairo, Egypt, Ahmed A.Elwahed Shaaban Associate Professor Of Prosthodontics, Future University In Egypt, [email protected]
Effect Of Different Implant Materials On Stresses Transmitted To Peri-Implant Areas Of Implant-Retained Mandibular Overdenture, Diaa Mohamed Zahran Future University In Egypt, [email protected], Aya Fawzy Associate Professor Of Prosthodontics, Future University In Egypt, [email protected], Salah Hegazy Professor Of Prosthodontics, Faculty Of Dentistry, Mansoura University, [email protected], Sara M. Shabaan Lecturer At Removable Prosthodontic Department, Faculty Of Oral And Dental Medicine , Badr University, Cairo, Egypt, Ahmed A.Elwahed Shaaban Associate Professor Of Prosthodontics, Future University In Egypt, [email protected]
Future Dental Journal
Aim this in vitro study was conducted to evaluate the effect of mechanical loading on different implant materials on supporting structures materials and methods: a total of three implant retained overdentures were used in this study, retained by two implants each (Titanium, polyetheretherketon and zirconia) were placed in epoxy resin casts at the canine area using a surgical guide. Soft liner material was used at the distal extension area to mimic the soft tissues. Two linear strain gauges were bonded buccal and lingual to each implant to measure the peri-implant strains during unilateral and bilateral loading. Results: during bilateral loading …
Effect Of Scan Body Design On The Accuracy Of The Implant Position In Implant Supported Prosthesis, Ahmed Safwat Elghazally ,Future University In Egypt, [email protected], Bassem Mohsen Associate Professor Of Prosthodontics, Future University In Egypt, [email protected], Amr Hosny Professor Of Prosthodontics, Faculty Of Dentistry – Cairo University In Egypt, [email protected], Hussien G. Elcharkawi Professor Of Prosthodontics, Future University In Egypt, [email protected]
Effect Of Scan Body Design On The Accuracy Of The Implant Position In Implant Supported Prosthesis, Ahmed Safwat Elghazally ,Future University In Egypt, [email protected], Bassem Mohsen Associate Professor Of Prosthodontics, Future University In Egypt, [email protected], Amr Hosny Professor Of Prosthodontics, Faculty Of Dentistry – Cairo University In Egypt, [email protected], Hussien G. Elcharkawi Professor Of Prosthodontics, Future University In Egypt, [email protected]
Future Dental Journal
Background: Several treatment options are planned for completely edentulous patients rehabilitation which were developed to meet patients desires and requirements, starting from conventional complete denture till implant supported fixed full arch cases. Each technique has its own indication and limitations. Passive fit is an important factor for the long-term success of implant- prosthesis, which necessitate accurate transfer of the implant position. Recently, digital impressions have been introduced in dental implant treatment. By the use of scan body and different optical scanning methods, the position of scan bodies can be transferred to a virtual implant position within the dental arch. Material …
Effect Of Concentrated Growth Factor Alone And Mixed With Hyaluronic Acid On Osseointegration Of Delayed Implant., Kholoud Sobhy Eldeeb Kholoud Eldeeb, Lobna Mohammed Abdelaziz, Shahira Elashiry, Eatemad Shoreibah
Effect Of Concentrated Growth Factor Alone And Mixed With Hyaluronic Acid On Osseointegration Of Delayed Implant., Kholoud Sobhy Eldeeb Kholoud Eldeeb, Lobna Mohammed Abdelaziz, Shahira Elashiry, Eatemad Shoreibah
Future Dental Journal
Purpose: The aim of current study was evaluating effect of concentrated growth factor alone and mixed with hyaluronic acid on osseointegration of delayed implant. Subject and Methods: A total of 12 patients, ranging in age from 20 to 45 years old, were divided into two groups in random manner. Group A: Dental implants were placed associating with concentrated growth factor. Group B: Dental implants were placed associating with concentrated growth factor and hyaluronic acid. Treatment changes were evaluated for each group and compared between groups. Results: In the mean of implant stability a statistically significant difference existed within group …
Effect Of Silver Diamine Fluoride On Micro-Tensile Bond Strength Of Composite To Dentin On Primary And Permanent Teeth, Dalia Yousry Ayoub B.D.Sc Faculty Of Dentistry, Sinai University,[email protected], Osama Ibrahim El-Shahawy Professor Of Pediatric Dentistry And Dental Public Health, Faculty Of Oral And Dental Medicine, Future University In Egyp,[email protected], Sara Ahmed Mahmoud .Professor Of Pediatric Dentistry And Dental Public Health Faculty Of Oral And Dental Medicine, Cairo University,[email protected], Eman Alaa Eldeen Abd Allah Associate Professor Of Pediatric Dentistry And Dental Public Health Faculty Of Oral And Dental Medicine, Future University In Egypt,[email protected]
Effect Of Silver Diamine Fluoride On Micro-Tensile Bond Strength Of Composite To Dentin On Primary And Permanent Teeth, Dalia Yousry Ayoub B.D.Sc Faculty Of Dentistry, Sinai University,[email protected], Osama Ibrahim El-Shahawy Professor Of Pediatric Dentistry And Dental Public Health, Faculty Of Oral And Dental Medicine, Future University In Egyp,[email protected], Sara Ahmed Mahmoud .Professor Of Pediatric Dentistry And Dental Public Health Faculty Of Oral And Dental Medicine, Cairo University,[email protected], Eman Alaa Eldeen Abd Allah Associate Professor Of Pediatric Dentistry And Dental Public Health Faculty Of Oral And Dental Medicine, Future University In Egypt,[email protected]
Future Dental Journal
Aim of the Study: The aim of the current study was to investigate the effect of silver diamine fluoride on micro-tensile bond strength of composite to dentin and on the bonding mechanism of dentin surface on primary and permanent teeth. Material and methods: This study included two groups: group 1 included twenty-four primary molars and group 2 included twenty-four premolars. Each group was further subdivided equally into sub-group A and sub-group B. Sub-groups A of each group were treated with a self-etch bonding system and 4-mm thick buildups of composite were placed with increments limited to 1 mm. Subgroups B …
Comparing Program Compatibility For Dental Operators Between Different In-Office Clear Aligners Software, Karim Ibrahim Hammam, Essam Nassef, Mostafa Al Dawltaly
Comparing Program Compatibility For Dental Operators Between Different In-Office Clear Aligners Software, Karim Ibrahim Hammam, Essam Nassef, Mostafa Al Dawltaly
Future Dental Journal
Aim: The aim of the present study was to compare program compatibility for dental operators between different in office clear aligners software: (3D Maestro,3shape, BlueSky bio, Plainmeca). Materials and methods: 4 in office clear aligners software: (3D Maestro,3shape, BlueSky bio, Plainmeca) were used. Ten orthodontists were recruited for the evaluation process, A total of 48 casts were used including upper and lower arches for each case. Each orthodontist made a check mark on each option in the pre-made scoring template.A check mark with YES was given a One point, and a check mark with NO was given Zero point. Results: …
Assessment Of External Apical Root Resorption Following En-Masse And Two Steps Retraction In Maxillary Protrusion Cases: A Randomized Controlled Clinical Trial, Aya Ahmed El Ashwal, Heba Mohamed Dehis, Faten Eid
Assessment Of External Apical Root Resorption Following En-Masse And Two Steps Retraction In Maxillary Protrusion Cases: A Randomized Controlled Clinical Trial, Aya Ahmed El Ashwal, Heba Mohamed Dehis, Faten Eid
Future Dental Journal
Aim: The aim of this study was to investigate the degree of external apical root resorption (EARR) following En-masse retraction (EM) and compared it to two steps retraction technique (TS) using friction mechanics.
Materials and Methods: Thirty adult female with maxillary protrusion were randomly allocated by a computer sequence generator with 1:1 allocation ratio. EM group (mean age = 17.7 ± 1.89 years) and TS group (mean age = 17.7 ± 1.77 years). Mini-screws were inserted followed by first premolars extraction then randomization was accomplished. Patients received treatment with either EM procedure or TS to close the extraction spaces after …
Oral Focal Mucinosis: A Case Report, Hala El-Kammar Dr, Yara Youssef, Bassant Mahmoud Moustafa, Iman M. Mostafa, Noha Adel Hassanine, Adham Fahmy, Rami Guiha Dr.
Oral Focal Mucinosis: A Case Report, Hala El-Kammar Dr, Yara Youssef, Bassant Mahmoud Moustafa, Iman M. Mostafa, Noha Adel Hassanine, Adham Fahmy, Rami Guiha Dr.
Future Dental Journal
Oral focal mucinosis is a rare lesion with less than 60 cases reported in English literature so far, to the best of our knowledge. It is considered to be the oral counterpart of cutaneous focal mucinosis and/or cutaneous myxoid cyst. Histopathologically, Oral focal mucinosis is demonsterates a well-circumscribed area of myxomatous connective tissue containing mucinous material, surrounded by denser collagenous connective tissue. We present a case of Oral focal mucinosis occurring on the buccal gingiva of the lower jaw.
Implant Site Preparation Using Conventional Drilling Technique Versus Magnetic Malleting Technique (Randomized Clinical Study)., Tamer Bahaa Negidah, Ahmed Farid Shehab Prof, Hussein Hatem, Sara Zakaria Fanous, Mostafa Azab
Implant Site Preparation Using Conventional Drilling Technique Versus Magnetic Malleting Technique (Randomized Clinical Study)., Tamer Bahaa Negidah, Ahmed Farid Shehab Prof, Hussein Hatem, Sara Zakaria Fanous, Mostafa Azab
Future Dental Journal
Background The purpose of our current study is to determine whether using a Magnetic Mallet during oral and implant surgical procedures is more effective than using traditional instruments with regard to complication rate, tissue healing, and surgical results (primary stability and crestal bone loss). According to a number of writers, a Magnetic Mallet can be utilized for implant insertion, ridge expansion, sinus lifts, tooth extractions, and implant site preparation.
So, this study was conducted to ascertain whether using a Magnetic Mallet Throughout the process of oral and surgical implant operations is effective and to assume on whether it might help …
Stability Of Immediately Placed And Delayed Implants Using Resonance Frequency Analysis (Rfa). A Systematic Review, Sara H. Younis, Catherine I. Radana, Doha M. Galal, Heba K. Abdul-Fattah, John A. Labib
Stability Of Immediately Placed And Delayed Implants Using Resonance Frequency Analysis (Rfa). A Systematic Review, Sara H. Younis, Catherine I. Radana, Doha M. Galal, Heba K. Abdul-Fattah, John A. Labib
Future Dental Journal
Objectives: The aim of the present Systematic Review was to compare between immediate and delayed dental implant placement using resonance frequency analysis specifically Implant Stability Quotients (ISQ).
Search methods: Search was performed in two databases (PubMed and Cochrane Library) till March 2023. Randomized clinical trials (RCTs) were included and measurements of ISQ at time of placement and time of loading were recorded. We excluded papers discussing bone grafting, orthodontic treatment and implant surface treatment.
Results: Results were above ISQ threshold value of 65, with no significant difference between immediate and delayed implants. However, Immediate placement showed shorter treatment time and …
Comparative Evaluation Of Marginal Adaptation Of Two Sealers With Two Different Obturation Techniques Using Sem (An In Vitro Study), Nada Mohammady Shaheen, Wael Hussein Kamel, Ahmed Abdel Rahman Hashem, Mahmoud Mohamed Badr
Comparative Evaluation Of Marginal Adaptation Of Two Sealers With Two Different Obturation Techniques Using Sem (An In Vitro Study), Nada Mohammady Shaheen, Wael Hussein Kamel, Ahmed Abdel Rahman Hashem, Mahmoud Mohamed Badr
Future Dental Journal
Aim: The sealing ability of endodontic obturation plays a important role in long term prognosis of an endodontic treatment. Aim To evaluate and compare the marginal adaptation of epoxy resin-based sealer (AH Plus) versus Bioceramic-based sealer (Total fill BC Sealer) to root canals that obturated with two obturation techniques (Lateral condensation and single cone techniques) using scanning electron microscope (SEM). Materials and Methods Sixty recently extracted single rooted mandibular premolars teeth were disinfected. Access cavity preparation was performed followed by cleaning and shaping, using 2.6% NaOCl as final irrigation protocol. Teeth were then equally divided into 4 groups according to …
Computer Guided Versus Conventional Maxillary Sinus Augmentation Using Allogenic Bone Blocks With Simultaneous Implant Placement In Severely Pneumatized Sinuses, Hisham G. Zulhemma Department Of Oral And Maxillofacial Surgery, Future University In Egypt, Egypt. [email protected], Waleed Ragab El-Beialy Professor Of Oral And Maxillofacial Surgery -Cairo University, Egypt. [email protected], Ahmed Abd Elsamad Associate Professor Of Oral And Maxillofacial Radiology– Cairo University, Egypt. [email protected], Ahmed Abozekry Lecturer Of Oral And Maxillofacial Surgery –Future University In Egypt, Egypt. [email protected]
Computer Guided Versus Conventional Maxillary Sinus Augmentation Using Allogenic Bone Blocks With Simultaneous Implant Placement In Severely Pneumatized Sinuses, Hisham G. Zulhemma Department Of Oral And Maxillofacial Surgery, Future University In Egypt, Egypt. [email protected], Waleed Ragab El-Beialy Professor Of Oral And Maxillofacial Surgery -Cairo University, Egypt. [email protected], Ahmed Abd Elsamad Associate Professor Of Oral And Maxillofacial Radiology– Cairo University, Egypt. [email protected], Ahmed Abozekry Lecturer Of Oral And Maxillofacial Surgery –Future University In Egypt, Egypt. [email protected]
Future Dental Journal
Background: Maxillary sinus lifting is a complex procedure with reported complications in the literature where the presence of sinus septa further complicates the procedure, they including membrane perforation, bleeding. Aim: The aim of this study is to decrease the incidence of membrane perforation which is the most common reported complication, and to determine whether the use of surgical guides could decrease the incidence of membrane perforation. Materials and methods: A total of 12 cases where blindly divided into 2 groups; Group (A) computer guided maxillary sinus lifting and Group (B) conventional sinus lifting, both groups received allogenic bone blocks for …
Effect Of Chlorhexidine On Nanoleakage And Bond Durability Of Two Adhesives To Dentin: An In Vitro Study, Rowayda Anwar Eltarawy, Essam Naguib, Ahmed Z. Elhoshy, Sara H. Younis
Effect Of Chlorhexidine On Nanoleakage And Bond Durability Of Two Adhesives To Dentin: An In Vitro Study, Rowayda Anwar Eltarawy, Essam Naguib, Ahmed Z. Elhoshy, Sara H. Younis
Future Dental Journal
Abstract
Aim: This study aimed to investigate the effect of chlorhexidine (CHX) on nanoleakage (NL) and dentin bond durability of two adhesives after water storage.
Materials and Methods: Thirty-six extracted molars were divided into three groups and their buccal surfaces were reduced to expose flat dentin surfaces. In group 1 Single Bond Universal Adhesive (SBU) was used, in group 2 Peak universal Bond (PUB) was applied while in group 3 Chlorhexidine Gluconate Disinfecting Solution followed by Single Bond Universal Adhesive (CHX+SBU) was used. Application of resin composite restorations was performed in all three groups. For each bonding procedure, …
Effect Of External Bleaching On Color Change Of Single Shade Resin Composite Versus Nano-Filled Resin Composite In Class V (In Vitro Study), Akram Gamal Diab, Essam Naguib, Ahmed Zoheir Elhoshy, Ahmed Mohamed Fouad
Effect Of External Bleaching On Color Change Of Single Shade Resin Composite Versus Nano-Filled Resin Composite In Class V (In Vitro Study), Akram Gamal Diab, Essam Naguib, Ahmed Zoheir Elhoshy, Ahmed Mohamed Fouad
Future Dental Journal
This study investigated the effect of bleaching on color change of the single shade universal composite (Omnichroma) versus nano-filled resin composite (Z350 XT).
Methods: Twenty premolars of shade A3 were used for the study. Standardized class V cavities were prepared on the cervical third of the buccal surface of all teeth. After that, teeth were randomly divided into two groups of 10 teeth each according to the type of resin composite used. After composite application, all teeth were stored individually in distilled water for 24 hours. Evaluation of the restoration color was done using VITA Easyshade. The teeth were bleached …
Evaluation Of Color Difference And Translucency Of Modified Peek Restorations Veneered With Different Veneering Materials Before And After Thermal Cycling, Mohamed Hamdy Abdulmaguied, Tarek Salah Morsi, Mennatallah M. Wahba, Hesham Katamish
Evaluation Of Color Difference And Translucency Of Modified Peek Restorations Veneered With Different Veneering Materials Before And After Thermal Cycling, Mohamed Hamdy Abdulmaguied, Tarek Salah Morsi, Mennatallah M. Wahba, Hesham Katamish
Future Dental Journal
Objective: The aim of this study was to investigate the effect of different PEEK veneering materials, as well as thermocycling on the color difference (ΔE) and the translucency parameter (TP) of modified PEEK veneered restorations.
Materials and Methods: Thirty disc shaped specimens of veneered BioHPP (1.5 mm X 12 mm) were randomly divided into three groups (n=10) based on the type of the veneering material. Group (A): Discs veneered with CAD milled Lithium Disilicate, group (B): Discs veneered with pre-cured milled composite, and group (C): Discs veneered with conventional light cured composite. CIELab values were calculated for all specimens over …
Clinical And Radiographic Assessment Of Xenogenic Bone Graft With Or Without Hyaluronic Acid For Post Extraction Socket Preservation (Randomized Clinical Trial), Khaled Mohie Aldeen Abdelzaher, Lobna Abdel Aziz Aly Prof, Mostafa Ezz Prof., Mahmoud Mohsen Elsayed Hassan Elarini Dr.
Clinical And Radiographic Assessment Of Xenogenic Bone Graft With Or Without Hyaluronic Acid For Post Extraction Socket Preservation (Randomized Clinical Trial), Khaled Mohie Aldeen Abdelzaher, Lobna Abdel Aziz Aly Prof, Mostafa Ezz Prof., Mahmoud Mohsen Elsayed Hassan Elarini Dr.
Future Dental Journal
hyaluronic acid shows osteogenic potentials which considered important property during bone regeneration. So, we aim to assess the efficiency of hyaluronic acid with xenograft mixture in post extraction alveolar sockets to decelerate resorption of dental alveolar ridge.
Evaluation Of Colour Reproduction Of Cad/Cam Lithuim-Disilicate Veneers Of Different Thicknesses And Translucency, Sahar H. Fikry, Tarek Salah Morsi, Mennatallah M. Wahba, Amr El-Etreby
Evaluation Of Colour Reproduction Of Cad/Cam Lithuim-Disilicate Veneers Of Different Thicknesses And Translucency, Sahar H. Fikry, Tarek Salah Morsi, Mennatallah M. Wahba, Amr El-Etreby
Future Dental Journal
Background: With the increasing patients’ demand for a perfect smile, the call for highly aesthetic and yet minimally invasive veneers has surmounted. Objective: The aim of this study was to evaluate the colour of CAD/CAM lithium disilicate veneers fabricated in different thicknesses and different translucencies of the lithium disilicate blocks. Materials and Methods: Forty discs of lithium disilicate glass-ceramic (IPS e.max CAD) of shade A1 of both high and low translucency (HT, LT) were tested for their colour reproduction. HT and low LT blocks were cut in the form of plates of dimensions (12 x 14 mm) and of different …
Effect Of Various Sintering Protocols On The Translucency Of Highly Translucent Cubic Zirconia, Kerolos Salah Mehany, Ashraf Hussein Sherif, Shereen Ahmed Nossair, Mona Hossam El-Din Mandour
Effect Of Various Sintering Protocols On The Translucency Of Highly Translucent Cubic Zirconia, Kerolos Salah Mehany, Ashraf Hussein Sherif, Shereen Ahmed Nossair, Mona Hossam El-Din Mandour
Future Dental Journal
Aim of the study: This study was carried out to evaluate the effect of various sintering protocols on the translucency of highly translucent cubic zirconia. Materials and methods: A total of forty discs of two types of zirconia ceramics were used in this study. The specimens were divided into two main groups according to the type of zirconia; Group 1 (n=20): Cubic zirconia (DD Cube X2 98color) and Group 2 (n=20): Tetragonal zirconia (BioZX2color). Each group was subdivided into two subgroups, where 10 discs were per subgroup according to the sintering protocol. Cubic and tetragonal zirconia blanks of dimensions (98 …
Effect Of Two Different Forms Of Smoking On Periodontium : A Retrospective Study, Mohammed Wagdy Bissar
Effect Of Two Different Forms Of Smoking On Periodontium : A Retrospective Study, Mohammed Wagdy Bissar
Future Dental Journal
Aim of the study: Is to compare the effects of smoking T-cigs and vaping E-cigs on clinical periodontal parameters in patients.Materials and Methods: It consisted of a clinical examination of a total of 60 individuals aged between 29 and 39 years. They responded to a questionnaire about their smoking history, and they were divided into 2 groups as E-cig vapers and T-cig smokers. Full-mouth plaque index (PI),bleeding on probing (BOP),clinical attachment loss (AL),and probing depth (PD) were measured at six sites per tooth on all maxillary and mandibular teeth except third molars. Results: T-cigarette had significantly higher probing depth, …
Effect Of Thickness On Translucency And Masking Ability Of A Recently Developed Single-Shade Resin Composite With Enhanced Opacity: An In Vitro Comparative Study, Sayed Mohamed Ghorab, Hagag Abd Elkader Atya
Effect Of Thickness On Translucency And Masking Ability Of A Recently Developed Single-Shade Resin Composite With Enhanced Opacity: An In Vitro Comparative Study, Sayed Mohamed Ghorab, Hagag Abd Elkader Atya
Future Dental Journal
ABSTRACT
Objective: This study aimed to evaluate the effects of thickness changes on translucency and masking ability of a recently developed single shade resin composite material with enhanced opacity comparing it with a traditional opaque-shade one.
Material and methods: Two brands of composite resins; Omnichroma blocker (OCB) and G-aenial Anterior (GA) in opaque A2 (OA2) shade were selected to enroll the study. Color coordinates of each composite were determined at 0.5, 1, and 1.5 mm thicknesses (n=10/thickness) on four different backgrounds (white baking, black baking, C4 shade porcelain baking and the backing of material itself) by using a …
Influence Of Etching Methods On The Shear Bond Strength Of A Universal Adhesive System To Sound And Artificial Caries-Affected Dentin, Omnia M. Sami, Essam A. Naguib, Rasha H. Afifi, Shaymaa M. Nagi
Influence Of Etching Methods On The Shear Bond Strength Of A Universal Adhesive System To Sound And Artificial Caries-Affected Dentin, Omnia M. Sami, Essam A. Naguib, Rasha H. Afifi, Shaymaa M. Nagi
Future Dental Journal
Abstract:
This study tested the effect of different etching methods on the bond strength of a universal adhesive system to caries-affected (CAD)and sound dentin. Methods: forty premolars were wet grinded to expose flat occlusal midcoronal dentin. Specimens were equally divided according to the substrate; sound and (CAD) by exposing to pH-cycling for 14 days. Each dentin substrate was bonded with Single BondTM universal adhesive applied either after no etching or etching of dentin, then resin composite was built up. Specimens were tested for shear bond strength (SBS). The data was analyzed by two-ways ANOVA. Results: Single BondTM universal …
Evaluation Of Strength Of Different Resin Materials Used In Overdenture, Mohamed Emam, Hesham E. Alam El Deen, Hamdy Abu El Fotoh, Ayman Fateen
Evaluation Of Strength Of Different Resin Materials Used In Overdenture, Mohamed Emam, Hesham E. Alam El Deen, Hamdy Abu El Fotoh, Ayman Fateen
Future Dental Journal
Introduction: Finding a suitable material that could be used to restore relatively small inter-arch spaces in which reasonable aesthetics as well as good functional strength could be achieved is a difficult process that requires good understanding of the clinical situation and precise management. Historically Metal used to offer the smallest possible thickness with excellent strength but lacks resiliency with poor aesthetics.
Aim of the study: This In-vitro study was conducted to compare two different aesthetic materials PEEK and ACETAL regarding their mechanical strength when used as Overdenture framework in a relatively small thickness.
Material and Methods: 120 specimens were …
Evaluation Of Incorporating Bracing Arm In Precision Attachment Unilateral Removable Partial Denture, Hussein El Charkawi, Aya Fawzy, Mohamed M. Dohiem
Evaluation Of Incorporating Bracing Arm In Precision Attachment Unilateral Removable Partial Denture, Hussein El Charkawi, Aya Fawzy, Mohamed M. Dohiem
Future Dental Journal
ABSTRACT
Purpose: This Randomized Control Trial study aimed to compare between two designs of Precision Attachment Unilateral Removable Partial Denture, one conventional design and the other modified with bracing arm and mesial rest.
Materials and Methods: twenty male patients having Kennedy Class II mandibular edentulous ridges received the two designs in a split mouth study for a follow-up period of eighteen months. Probing Pocket Depth around abutment was measured. A standardized radiographic technique was used to evaluate bone height changes.
Results: The results showed insignificant pocket depth and bone height changes in the two groups.
Conclusion: Precision Attachment Unilateral Removable …