Evaluation Of Push Out Bond Strength Of Glass Fiber Post Related With Ultrasonic Irrigation, Nomjit Vidhyaphum Jan 2017

Evaluation Of Push Out Bond Strength Of Glass Fiber Post Related With Ultrasonic Irrigation, Nomjit Vidhyaphum

Chulalongkorn University Theses and Dissertations (Chula ETD)

Objective This study compared the bond strength of glass fiber post to dentin using different irrigation methods and solutions and to evaluate the bond strength in different regions of the root. Methods One hundred human anterior maxillary teeth were randomly divided into 10 groups (n=10). Root canal filling and post space preparation were carried out followed by diverse final irrigation techniques. Groups 1 to 3 underwent syringe irrigation, groups 4 to 6 irrigation with ultrasonic instrumentation and groups 7 to 9 passive ultrasonic irrigation. Different irrigant solutions were used in each groups as 2.5% NaOCl (groups 1,4,7), 17% EDTA (groups …


Microleakage Of Enamel Preservation At Gingival Wall Of Class Ii Resin Composite Restorations (Nanofilled Vs Bulk-Fill), Onladda Pisuttiwong Jan 2017

Microleakage Of Enamel Preservation At Gingival Wall Of Class Ii Resin Composite Restorations (Nanofilled Vs Bulk-Fill), Onladda Pisuttiwong

Chulalongkorn University Theses and Dissertations (Chula ETD)

Objectives. This in vitro study tested the hypothesis that preserving a thin enamel layer at the gingival margin and using bulk-fill resin composites could minimize microleakage of class II resin composite. Materials and Methods. Thirty-six human third molars were randomly divided into three groups of 12 specimens each: Filtek Bulk Fill Posterior Restorative in Capsules (BFC), Filtek Bulk Fill Posterior Restorative in Syringes (BFS) and Filtek Z350 XT (Z350). Teeth were prepared on two sides for a class II cavity (3 mm buccolingually x 2 mm mesiodistally at occlusal and 1.5 mm at coronal x 4 mm of axial depth) …


Effect Of Remineralization On Color Change Of Bleached Tooth, Panita Suttisakpakdee Jan 2017

Effect Of Remineralization On Color Change Of Bleached Tooth, Panita Suttisakpakdee

Chulalongkorn University Theses and Dissertations (Chula ETD)

The aim of this in vitro study was to investigate the effect of remineralization and time on the color and microhardness change of teeth bleached using 10% carbamide peroxide (10%CP) or 40% hydrogen peroxide (40%HP). Seventy-two 6x6x2 mm3 enamel slabs were prepared from human premolars. The specimens' color and Vickers' microhardness were recorded at baseline (T0). The specimens were divided into six groups, two groups were treated with 10%CP with or without casein phosphopeptides and amorphous calcium phosphate (CPP-ACP) (10%CP and 10% CP/CPP-ACP, respectively), two groups were treated with 40% HP with or without CPP-ACP (40%HP and 40%HP/CPP-ACP, respectively), one …


The Overall Esthetic Assessment Of Anterior Single-Tooth Implant Restoration: Modified Objective Criteria, Pongsakorn Komutpol Jan 2017

The Overall Esthetic Assessment Of Anterior Single-Tooth Implant Restoration: Modified Objective Criteria, Pongsakorn Komutpol

Chulalongkorn University Theses and Dissertations (Chula ETD)

Objectives: The aim of this study was to observe the correlation of esthetic outcomes of single-tooth implant restoration when using Pink Esthetic Score/White Esthetic Score and the new modified assessment (Modified Objective Criteria; MOC) Materials and Methods: This crossectional retrospective study, up to 5 years, recruited 26 patients who single implant in maxillary central incisor area was placed. All the implants were recalled. Demographic data, intraoral photograph, dental model, periapical radiograph and CBCT were taken. One examiner assessed the esthetic outcomes by using PES/WES and MOC (gingiva, prosthesis and bone foundation) with 2 weeks between each evaluation. The score of …


A Comparison Of Taper-Implant Designs And Bone Quality On The Primary Stability: An In Vitro Biomechanical Study, Ratchaya Chayangsu Jan 2017

A Comparison Of Taper-Implant Designs And Bone Quality On The Primary Stability: An In Vitro Biomechanical Study, Ratchaya Chayangsu

Chulalongkorn University Theses and Dissertations (Chula ETD)

Objective To investigate the effect of the taper-implant design and the effect of bone quality on the primary stability in terms of insertion torque test, removal torque test and resonance frequency analysis. Methods Five taper-implant designs were test in artificial bone blocks with four qualities. Five repetitions per implant design were placed in each bone quality started from softest bone block. The implant motor was used to prepared the osteotomy sites and implant insertion according to manufacturers' recommendation. Peak insertion torque values were measured and recorded by implant motor when the platform of the implant flush to the bone level. …


The Longevity Of Ceramic Veneers: Clinical Evaluation Of Mechanical, Biological, And Esthetic Performances Of Ceramic Veneers Up To 7-Years Retrospective Study, Rapeepan Monaraks Jan 2017

The Longevity Of Ceramic Veneers: Clinical Evaluation Of Mechanical, Biological, And Esthetic Performances Of Ceramic Veneers Up To 7-Years Retrospective Study, Rapeepan Monaraks

Chulalongkorn University Theses and Dissertations (Chula ETD)

Purpose: To evaluate the longevity and mechanical, biological and aesthetic performance of ceramic veneers placed after 5 to 7 years in service. Materials and Methods: Ceramic veneer restorations were clinically examined following modified from the United States Public Health Service (USPHS) and World Dental Federation (FDI) criteria. Clinical evaluation was performed by two clinicians regarding mechanical, biological and aesthetic performances during maintenance appointments between September 2016 and August 2017. Intra-examiner and inter-examiner reliability were evaluated by calculating the intraclass correlation coefficient and inter-examiner calibration. The results were analysed by Kaplan-Meier survival estimation method and log-rank test at a 95% confidence …


Host Responses In Peri Implant Tissue In Comparison To Periodontal Tissue, Raviporn Madarasmi Jan 2017

Host Responses In Peri Implant Tissue In Comparison To Periodontal Tissue, Raviporn Madarasmi

Chulalongkorn University Theses and Dissertations (Chula ETD)

The host response in peri-implant tissue may differ from that in periodontal tissue in a healthy individual. The purpose of this study is to investigate the expression of inflammatory cytokines in peri-implant crevicular fluid (PICF)from single implant with two different abutment types in comparison to healthy periodontal tissue. Moreover, the effect of these inflammatory cytokines on the expression of FAK and RANKL were also studied. Nineteen participants with healthy implants and teeth were recruited according to the inclusion and exclusion criteria. PICF and gingival crevicular fluid (GCF) was collected using sterile paper points. The expression level of inflammatory cytokines including …


Evaluation Of Voids In Class Ii Restorations Restored With Bulk-Fill And Conventional Nanohybrid Resin Composite, Saiisara Chaidarun Jan 2017

Evaluation Of Voids In Class Ii Restorations Restored With Bulk-Fill And Conventional Nanohybrid Resin Composite, Saiisara Chaidarun

Chulalongkorn University Theses and Dissertations (Chula ETD)

Objectives: The aim of the study was to evaluate the influence of four resin composites on voids in small and large Class II cavities. Furthermore, the thickness of the first increment of the restorations was studied. Methods: Eighty artificial lower second premolars were divided into two preparation designs with 40 standardized Class II cavities in each, and then restored with four resin composites (three bulk-fill types: SonicFill 2, Filtek Bulk Fill (capsule), Filtek Bulk Fill (syringe) and a conventional nanohybrid resin composite: Premise). Restorations were sectioned for microscopic evaluation and a Kruskal-Wallis analysis was performed to evaluate the number of …


Immunohistochemical Assessment Of The Peri-Implant Soft Tissues Around Different Abutment Materials : An Experimental Study In Human, Sirikarn Thongmeearkom Jan 2017

Immunohistochemical Assessment Of The Peri-Implant Soft Tissues Around Different Abutment Materials : An Experimental Study In Human, Sirikarn Thongmeearkom

Chulalongkorn University Theses and Dissertations (Chula ETD)

Objective To evaluate the effect of 4 different types of abutment material, which are titanium, zirconium oxide, gold alloy, and zirconia-coping cemented on titanium-base, on the surrounding soft tissues. Material and Methods Twenty dental implants in posterior edentulous area were randomly divided into 4 groups and inserted 4 types of abutment materials; Titanium, zirconia, gold-alloy, and titanium-base, on the implant installation surgery day. Eight weeks after implant surgery, peri-implant soft tissues around experimental abutments were harvested and split according to implant side; buccal, lingual, mesial, and distal. The specimens were processed through immunohistochemical preparation and stained with CD3, CD20, CD68, …


An Investigation Of Surface Characteristics Of Enamel Treated With Infiltrative Resin: A Scanning Electron Microscopy Study, Danielle E. Easterly Jan 2017

An Investigation Of Surface Characteristics Of Enamel Treated With Infiltrative Resin: A Scanning Electron Microscopy Study, Danielle E. Easterly

Theses and Dissertations

AN INVESTIGATION OF SURFACE CHARACTERISTICS OF ENAMEL TREATED WITH INFILTRATIVE RESIN: A SCANNING ELECTRON MICROSCOPY STUDY

Danielle E. Easterly, Doctorate of Dental Surgery.

A thesis submitted in partial fulfillment of the requirements for the degree of Master of Science in Dentistry at Virginia Commonwealth University.

Virginia Commonwealth University. 2017.

Director: Dr. Eser Tüfekçi

D.D.S., M.S., Ph.D., M.S.H.A.

Objective: To evaluate the microstructural changes of a resin infiltrant (ICON®, DMG America LLC, Englewood, NJ) after six months of simulated toothbrushing.

Materials and Methods: Ten extracted third molars (n=10) were collected. Artificial white spot lesions were created and resin applied. Environmental SEM …


A Study Of The Relationship Between Job Related Stress And Temporomandibular Disorders In Accountants Working In Jakarta, Cindy Maura Saputra, Laura Susanti Himawan, Ira Tanti Dec 2016

A Study Of The Relationship Between Job Related Stress And Temporomandibular Disorders In Accountants Working In Jakarta, Cindy Maura Saputra, Laura Susanti Himawan, Ira Tanti

Journal of Dentistry Indonesia

Stress is a known risk factor for Temporomandibular Disorders (TMD), however there are few studies of TMD in people who work in high stress jobs. Accounting is a profession known for its high levels of stress and expectation. Objective: The aim of this study is to investigate the relationship between the intensity and frequency of job related stress and the occurrence of TMD in accountants in Jakarta. Methods: A cross-sectional study, with ethics approval from the Ethical Committee of the Faculty of Dentistry, University Indonesia, was performed on 116 accountants aged 21 to 50, living in Jakarta. Subjects were asked …


Effects Of Flash-Free Technique On Plaque Retention, White Spot Lesions, And Bracket Failure: A Randomized Clinical Trial, Payam Ishani Afousi Dec 2016

Effects Of Flash-Free Technique On Plaque Retention, White Spot Lesions, And Bracket Failure: A Randomized Clinical Trial, Payam Ishani Afousi

Theses & Dissertations

A side effect of orthodontic treatment is the development of white spot lesions (WSLs). This thesis attempted to evaluate the effects of the use of APC™ Flash-Free (FF) and conventional adhesives in bonding of orthodontic brackets on plaque formation and retention, WSL development, and bracket failure in-vivo. This was accomplished by collecting plaque samples from around orthodontic appliances and analyzing them using ATP-driven bioluminescence; scanning enamel surfaces using the Canary System™ to evaluate WSL development, and counting the number of spontaneous debonding of brackets of the 4 maxillary incisors in the first 6 months of treatment. It was found …


Color Change Of Commercial Resin Composited With Different Photoinitiators, Feng Gao Oct 2016

Color Change Of Commercial Resin Composited With Different Photoinitiators, Feng Gao

Master's Theses (2009 -)

Camphorquinone (CQ) is the most commonly used photoinitiator in light-cured dental resin composites. However CQ is associated with a yellowing effect, which has led manufacturers to add alternative initiators into resin composites to reduce the amount of CQ used. The color change upon polymerization by light and aging in artificial saliva and room air of 8 commercial traditional or bulk-fill resin composites with or without additional photoinitiator(s) beside CQ was studied. The three traditional resin composites with CQ and additional photoinitiator(s) tested were Tetric EvoCeram (Ivoclar Vivadent), AELITE LS Posterior (Bisco), and Vit-l-escence (Ultradent). The two bulk-fill resin composites with …


Correlation Of Tooth Length Measurements Made On Cbct And 3t Mr Images, Andrew Scott Taylor Sep 2016

Correlation Of Tooth Length Measurements Made On Cbct And 3t Mr Images, Andrew Scott Taylor

Loma Linda University Electronic Theses, Dissertations & Projects

Objective. This study compared tooth length measurements made on cone beam computed tomography (CBCT) scans and 3-Tesla (3T) magnetic resonance (MR) scans performed with and without an alginate bite registration surrounding the crowns of the teeth. Materials and Methods. One CBCT scan, one MR scan with alginate bite registration, and one MR scan without bite registration were performed on 12 subjects. The alginate bite registration was used to provide a proton-rich material to surround proton-poor teeth in an attempt to improve visualization of teeth. DICOM formatted images from each of the three scans for each subject were oriented in all …


Flexural Strength Of Nano-Hybrid Resin Composite As A Function Of Light Attenuation Distance And Specimen Dimension, Farid Sabry El-Askary Pro. Dr., Sara Adel Botros Dr., Mohamed Salah Abdelaziz Nassif Pro. Dr., Mutlu Özcan Prof. Dr. Aug 2016

Flexural Strength Of Nano-Hybrid Resin Composite As A Function Of Light Attenuation Distance And Specimen Dimension, Farid Sabry El-Askary Pro. Dr., Sara Adel Botros Dr., Mohamed Salah Abdelaziz Nassif Pro. Dr., Mutlu Özcan Prof. Dr.

Dentistry

This study evaluated ascending order of light attenuation distance (0, 2, 4, 8 mm) and specimen dimensions (2 × 2 × 10, 2 × 2 × 12, 2 × 2 × 15 mm3) differing from requirements of ISO 4049 (2 × 2 × 25 mm3) on the flexural strength of nano-hybrid resin composite. Specimens (N = 160) were prepared accordingly and randomly assigned into groups for the factors studied. Specimens were photo-polymerized from increased distances through 1, 2, 3 and 5 overlapping cycles depending on the specimen length after which they were subjected to three-point bending test (0.5 mm/min). …


Get In The Zone: A Survey Of Dental Professionals' Knowledge Of Ozone Therapy, Emily Hannah Aug 2016

Get In The Zone: A Survey Of Dental Professionals' Knowledge Of Ozone Therapy, Emily Hannah

Mahurin Honors College Capstone Experience/Thesis Projects

Ozone therapy has been used in medicine for many years to treat a variety of ailments. Ozone is an unstable triatomic molecule made up of three oxygen atoms. This molecule has the ability to kill bacteria, fungi, parasites, and viruses. The researcher first was curious if there has been research done on uses of Ozone Therapy in the dental setting. After reviewing the literature there is indeed a use for Ozone Therapy to treat a host of dental problems including periodontal disease, ulcers, and carious lesions (also known as cavities). However, there are conflicting conclusions in the literature as to …


Thermal Properties Of Copper Nickel-Titanium Orthodontic Archwires, Joshua Gilbert Jul 2016

Thermal Properties Of Copper Nickel-Titanium Orthodontic Archwires, Joshua Gilbert

Master's Theses (2009 -)

Introduction: Copper Nickel-Titanium (CuNiTi) is a relatively new composition of Nickel-Titanium (NiTi) archwires that was originally patented in 1991 as part of the Ormco line of wires. The patent has now recently expired and many other orthodontic companies are making their own CuNiTi wires. Advertisement claims have focused on the laboratory benefits of adding Copper (Cu) to the NiTi, however few independent laboratory testings have been conducted on these new wires to verify claims. The purpose of this study was to conduct thermal analysis of CuNiTi for all currently available wires in two Austenite Finish (Af) variants and two commonly …


Mechanical Properties Of Copper-Nickel-Titanium Archwires, Margaret Amelia Rosen Jul 2016

Mechanical Properties Of Copper-Nickel-Titanium Archwires, Margaret Amelia Rosen

Master's Theses (2009 -)

Introduction: The initial phase of orthodontic therapy relies on flexible wires, usually composed of a nickel-titanium alloy, to apply a substantially constant load during tooth movement. Copper has been added to nickel-titanium archwires, resulting in an alloy with potential clinical advantages such as a lower stress hysteresis. Many orthodontic companies claim that their copper-nickel-titanium manufacturing process allows for the production of more consistent transition temperatures in the wires, allowing the orthodontist to customize treatment to various patients based on the force level needed. There are currently many manufacturers of these wires, creating a wide range of copper-nickel-titanium archwires from which …


Influence Of Low Temperature Degradation On Microstructural Integrity Of Zirconia Dental Implants, Mona Monzavi Rahimi Jun 2016

Influence Of Low Temperature Degradation On Microstructural Integrity Of Zirconia Dental Implants, Mona Monzavi Rahimi

Loma Linda University Electronic Theses, Dissertations & Projects

Zirconia dental implants have become more popular in the field of implant dentistry. However, concerns have been raised regarding low temperature degradation and its influence on phase stability and micro-structural integrity in terms of increased micro-crack formation. In the case of dental implants, this could possibly result in delamination and interference with bone to implant contact and eventually lead to loss of integration and failure. Nevertheless, no study has reported the effects on commercially available Zirconia dental implants. The primary aims of this study was to determine if there is a correlation between ageing duration and 1) depth of tetragonal-monoclinic …


Influence Of Curing Protocol On Bond Strength Of Self-Etching Adhesives, Sara Adel Botros, Farid Sabry El-Askary, Mohamed Salah Nassef Jun 2016

Influence Of Curing Protocol On Bond Strength Of Self-Etching Adhesives, Sara Adel Botros, Farid Sabry El-Askary, Mohamed Salah Nassef

Dentistry

No abstract provided.


Effect Of Light Distance Specimen Length On Flexural Strength Of Resin-Composite, Sara Adel Botros, Farid Sabry El-Askary, Mohamed Salah Nassef Jun 2016

Effect Of Light Distance Specimen Length On Flexural Strength Of Resin-Composite, Sara Adel Botros, Farid Sabry El-Askary, Mohamed Salah Nassef

Dentistry

No abstract provided.


Color Stability, Physical Properties And Antifungal Effects Of Zro2 And Tio2 Nanoparticle Additions To Pigmented Polydimethylsiloxanes, Mazen Alkahtany May 2016

Color Stability, Physical Properties And Antifungal Effects Of Zro2 And Tio2 Nanoparticle Additions To Pigmented Polydimethylsiloxanes, Mazen Alkahtany

Theses & Dissertations

Introduction: Color changes, physical degradation and fungal infections are potential challenges to the longevity of polydimethylsiloxane (PDMS) elastomers. The purpose of this study was to evaluate potential improvements in color change, physical properties and anti fungal properties of PDMS loaded with TiO2 and ZrO2 nanoparticles.

Methods: 1% weight of 40 nm or 200 nm diameter TiO2 or ZrO2 nanoparticles were mixed into PDMS with 2% functional intrinsic yellow pigment and polymerized. Control materials contained 13% weight 200 nm silica. Samples were exposed to either 3000 hours of UVB radiation (200 μW/cm2) or darkness. Color parameters L*a*b* and ΔE*, ultimate tensile …


Evaluation Of Die Trim Morphology Made By Cad/Cam Technology, Pratiksha Agrawal Apr 2016

Evaluation Of Die Trim Morphology Made By Cad/Cam Technology, Pratiksha Agrawal

Master's Theses (2009 -)

Purpose: The purpose of this vitro study was to evaluate the accuracy of the morphology of digitally trimmed dies in comparison with the subgingival contour of a prepared tooth to be restored with a single crown. Materials and Methods: 20 human extracted teeth, 10 incisors and 10 molars were disinfected, mounted on dentoforms. The teeth were prepared for a single all ceramic restoration. Digital impressions of the preparations were made using the 3M Lava COS. With the data, the SLA models were fabricated with removable dies. The prepared tooth and the corresponding dies were then compared with the Rhino software. …


Mitigating Distortion Of Light-Polymerized Composite Trial Bases, Jon Patrick Irelan Apr 2016

Mitigating Distortion Of Light-Polymerized Composite Trial Bases, Jon Patrick Irelan

Master's Theses (2009 -)

Triad Visible Light Cure (VLC) Denture Base Material, a light-polymerizing resin material, is commonly used by clinicians to make trial bases during the fabrication of dentures and in planning the prosthetic and surgical rehabilitation of edentulous patients. A well-known drawback to this material, however, is its tendency to distort during the light-polymerization process. This distortion tends to occur most often towards the posterior aspect of the palate, and can negatively impact the bases ability to be retained through suction to the edentulous arch. The purpose of this study was to evaluate whether an experimental polymerization protocol can mitigate distortion during …


Torsion And Bending Properties Of Edgeendo Files, Chad Hansen Apr 2016

Torsion And Bending Properties Of Edgeendo Files, Chad Hansen

Master's Theses (2009 -)

Introduction: One important step of root canal therapy is the process of cleaning and shaping each canal. This process involves using endodontic rotary files combined with chemical irrigants to remove pulpal remnants and infected dentin from the canal while eliminating pathogenic bacteria. It is essential to maintain proper canal anatomy while cleaning and shaping. The challenge for the practitioner is to select a rotary file system that will be flexible enough to maintain canal anatomy but strong enough to prevent breakage under normal use. File flexibility allows for better maintenance of canal anatomy. A file’s resistance to torsional fatigue reduces …


Viability Of Human Periodontal Ligament Fibroblasts After Storage In Save-A-Tooth, Emt Toothsaver And Hank's Balanced Salt Solution, Wonhee Lee Apr 2016

Viability Of Human Periodontal Ligament Fibroblasts After Storage In Save-A-Tooth, Emt Toothsaver And Hank's Balanced Salt Solution, Wonhee Lee

Master's Theses (2009 -)

Introduction: Viability of periodontal ligament (PDL) cells is a key prognostic factor fora replanted tooth following avulsion. Dehydration results death of PDL cells, which in turn causes ankylosis upon replantation, followed by replacement resorption. Hank’s Balanced Salt Solution (HBSS) has been recommended as the standard storage medium for an avulsed tooth. Save-A-Tooth and EMT Tooth saver (Dentosafe)are commercially available tooth storage media. With the best of our knowledge no study has yet compared these media for their effective tooth storage times. The aim of this invitro study is to evaluate Save-A-Tooth, EMT Toothsaver (Dentosafe), and HBSS for their effect on …


Effects Of Microwave Irradiation On The Dimensional Stability Of Complete Denture Bases, Miguel Pappaterra Mar 2016

Effects Of Microwave Irradiation On The Dimensional Stability Of Complete Denture Bases, Miguel Pappaterra

Loma Linda University Electronic Theses, Dissertations & Projects

Introduction: Maintenance for complete dentures is a role that must be undertaken by the patient. It has been determined that two minutes of microwave irradiation at 650 Watts provides denture disinfection, and three minutes provide sterilization32,34. There is insufficient data on how this practice affects the long term dimensional stability of commonly used complete denture bases in the United States. Purpose: The purpose of this study was to perform an in-vitro investigation, testing and comparing the effects of microwave irradiation on the dimensional stability of three types of complete denture bases. Materials and Methods: An edentulous master cast with reference …


Libro De Actividades Por El Mes Nacional De La Salud Dental Infantil [Spanish Language Version: National Children's Dental Health Month Activity Book] (2016), American Dental Association Foundation Jan 2016

Libro De Actividades Por El Mes Nacional De La Salud Dental Infantil [Spanish Language Version: National Children's Dental Health Month Activity Book] (2016), American Dental Association Foundation

National Children's Dental Health Month

No abstract provided.


National Children's Dental Health Month Activity Book (2016), American Dental Association Foundation Jan 2016

National Children's Dental Health Month Activity Book (2016), American Dental Association Foundation

National Children's Dental Health Month

No abstract provided.


Effect Of Polymerization Protocol On The Degree Of Conversion Of Photo- And Dual-Polymerized Self-Etch Adhesives, Lamiaa Mahmoud Moharam Dr., Sara Adel Botros Dr., Farid Sabry El-Askary Pro. Dr., Mutlu Özcan Prof. Dr. Oct 2015

Effect Of Polymerization Protocol On The Degree Of Conversion Of Photo- And Dual-Polymerized Self-Etch Adhesives, Lamiaa Mahmoud Moharam Dr., Sara Adel Botros Dr., Farid Sabry El-Askary Pro. Dr., Mutlu Özcan Prof. Dr.

Dentistry

This study investigated the effect of different polymerization protocols on the degree of conversion (DC%) of various photo-polymerized and dual-polymerized self-etch adhesive resins. Five different photo-polymerized (All-Bond Universal, Bisco; G-ænial Bond, GC; Futurabond M+ LC, VOCO; Single Bond Universal LC, 3M ESPE and Peak Universal Bond, Ultradent) and four dual-polymerized self-etch adhesives (Futurabond U, VOCO; Gradia Core SE, GC; Futurabond M+ DC, VOCO and Single Bond Universal DC, 3 M ESPE) were tested. All adhesives were applied on potassium bromide pellets (KBr) following the manufacturer’s instructions. The KBr pellets were divided into 10 experimental groups for the photo-polymerized adhesives and …