Open Access. Powered by Scholars. Published by Universities.®

Biomedical Commons™

Open Access. Powered by Scholars. Published by Universities.®

852 Full-Text Articles 1,675 Authors 446,736 Downloads 87 Institutions

All Articles in Biomedical

Faceted Search

852 full-text articles. Page 31 of 39.

Ablation Of Myocardial Tissue With Nanosecond Pulsed Electric Fields, Fei Xie, Frency Varghese, Andrei G. Pakhomov, Iurii Semenov, Shu Xiao, Jonathan Philpott, Christian Zemlin 2015 Old Dominion University

Ablation Of Myocardial Tissue With Nanosecond Pulsed Electric Fields, Fei Xie, Frency Varghese, Andrei G. Pakhomov, Iurii Semenov, Shu Xiao, Jonathan Philpott, Christian Zemlin

Bioelectrics Publications

Background

Ablation of cardiac tissue is an essential tool for the treatment of arrhythmias, particularly of atrial fibrillation, atrial flutter, and ventricular tachycardia. Current ablation technologies suffer from substantial recurrence rates, thermal side effects, and long procedure times. We demonstrate that ablation with nanosecond pulsed electric fields (nsPEFs) can potentially overcome these limitations.

Methods

We used optical mapping to monitor electrical activity in Langendorff-perfused New Zealand rabbit hearts (n = 12). We repeatedly inserted two shock electrodes, spaced 2–4 mm apart, into the ventricles (through the entire wall) and applied nanosecond pulsed electric fields (nsPEF) (5–20 kV/cm, 350 ns duration, …


A Methodology For Physically-Based Contact And Meniscus Properties In Rigid-Body Computational Knee Modeling, Stephen Wilson 2015 University of Texas at El Paso

A Methodology For Physically-Based Contact And Meniscus Properties In Rigid-Body Computational Knee Modeling, Stephen Wilson

Open Access Theses & Dissertations

Determining natural inner knee mechanics is a longstanding goal for researchers with applications to prevention and treatment of knee trauma and osteoarthritis. Physical testing has only provided limited information of knee mechanics due to technical challenges and cost. Modeling has been used for decades to obtain some of this otherwise inaccessible information, and recently finite element analysis (FEA) has become a popular means to this end. However, FEA requires time intensive mesh-creation and has large computational requirements. Ideally, model creation should be easy and simulations should be fast to allow for sensitivity analysis. Although allowing easier model creation and offering …


Modular Biped Robotic Base, Lawrence T. Chiavaroli, Andrew J. Forchione, Wesley A. Miller, Joseph M. Drockton 2015 The University Of Akron

Modular Biped Robotic Base, Lawrence T. Chiavaroli, Andrew J. Forchione, Wesley A. Miller, Joseph M. Drockton

Williams Honors College, Honors Research Projects

This report contains the final developments and research involved with the modular biped robotic base. A need was first identified in 2011 when President Obama announced the National Robotics Initiative, an initiative focused on the funding of robotic development to work alongside or cooperatively with humans. This scope of this project concerns building a robotic base modeled after human legs and hips, capable of interfacing with future modular subsystems depending on what tasks are trying to be accomplished. Firstly, a mathematical torque simulation of the hip, knee, and ankle joints was developed in MATLAB. Using this information, complimentary actuators and …


Assessment Of Electrode Configurations Of Electrical Impedance Myography For The Evaluation Of Neuromuscular Diseases, Khondokar Mohammad Fazle Rabbi 2015 Georgia Southern University

Assessment Of Electrode Configurations Of Electrical Impedance Myography For The Evaluation Of Neuromuscular Diseases, Khondokar Mohammad Fazle Rabbi

College of Graduate Studies: Theses & Dissertations

Electrical impedance myography (EIM) is a painless, noninvasive approach to measure the neuromuscular disease status. EIM parameters- resistance (R), reactance (X) and phase (θ) depend significantly on subcutaneous fat thickness, muscle size and inter electrode distance. The objective of this research is to find an electrode configuration which can minimize the effects on EIM parameters due to subcutaneous fat thickness variation. In this study, a model of human upper arm was developed using finite element method (FEM), which has already been established as an appropriate approach for the analysis of non-symmetrical shape for assessing alternations of muscle in disease-induced changes …


Large Dynamic Range Amplifier Plus Adc, Ted Hsueh 2015 California Polytechnic State University - San Luis Obispo

Large Dynamic Range Amplifier Plus Adc, Ted Hsueh

Electrical Engineering

Nerve and muscle signal sampling proves difficult because of the large difference in magnitudes. Muscle signals loom a hundred or even a thousand times bigger and can hide the nerve signals. The Large Dynamic Range Amplifier plus Analog to Digital Converter (ADC) allows one device to retrieve both muscle and nerve signal information. The device has two parts: the ability to take high-resolution data from tenths of microvolts to several millivolts and filter out environmental noise, such as 60 Hz of electrical power lines or electro galvanic signals. This gives the ability to read muscle and nerve signals using one …


Application And Histology-Driven Refinement Of Active Contour Models To Functional Region And Nerve Delineation: Towards A Digital Brainstem Atlas, Nimal Patel, Sharmin Sultana, Tanweer Rashid, Dean Krusienski, Michel A. Audette 2015 Old Dominion University

Application And Histology-Driven Refinement Of Active Contour Models To Functional Region And Nerve Delineation: Towards A Digital Brainstem Atlas, Nimal Patel, Sharmin Sultana, Tanweer Rashid, Dean Krusienski, Michel A. Audette

Electrical & Computer Engineering Faculty Publications

This paper presents a methodology for the digital formatting of a printed atlas of the brainstem and the delineation of cranial nerves from this digital atlas. It also describes on-going work on the 3D resampling and refinement of the 2D functional regions and nerve contours. In MRI-based anatomical modeling for neurosurgery planning and simulation, the complexity of the functional anatomy entails a digital atlas approach, rather than less descriptive voxel or surface-based approaches. However, there is an insufficiency of descriptive digital atlases, in particular of the brainstem. Our approach proceeds from a series of numbered, contour-based sketches coinciding with slices …


Adaptive Graph Construction For Isomap Manifold Learning, Loc Tran, Zezhong Zheng, Guoquing Zhou, Jiang Li, Karen O. Egiazarian (Ed.), Sos S. Agaian (Ed.), Atanas P. Gotchev (Ed.) 2015 Old Dominion University

Adaptive Graph Construction For Isomap Manifold Learning, Loc Tran, Zezhong Zheng, Guoquing Zhou, Jiang Li, Karen O. Egiazarian (Ed.), Sos S. Agaian (Ed.), Atanas P. Gotchev (Ed.)

Electrical & Computer Engineering Faculty Publications

Isomap is a classical manifold learning approach that preserves geodesic distance of nonlinear data sets. One of the main drawbacks of this method is that it is susceptible to leaking, where a shortcut appears between normally separated portions of a manifold. We propose an adaptive graph construction approach that is based upon the sparsity property of the ℓ1 norm. The ℓ1 enhanced graph construction method replaces k-nearest neighbors in the classical approach. The proposed algorithm is first tested on the data sets from the UCI data base repository which showed that the proposed approach performs better than …


A Comparative Study Of Two Prediction Models For Brain Tumor Progression, Deqi Zhou, Loc Tran, Jihong Wang, Jiang Li, Karen O. Egiazarian (Ed.), Sos S. Agaian (Ed.), Atanas P. Gotchev (Ed.) 2015 Princess Anne High School

A Comparative Study Of Two Prediction Models For Brain Tumor Progression, Deqi Zhou, Loc Tran, Jihong Wang, Jiang Li, Karen O. Egiazarian (Ed.), Sos S. Agaian (Ed.), Atanas P. Gotchev (Ed.)

Electrical & Computer Engineering Faculty Publications

MR diffusion tensor imaging (DTI) technique together with traditional T1 or T2 weighted MRI scans supplies rich information sources for brain cancer diagnoses. These images form large-scale, high-dimensional data sets. Due to the fact that significant correlations exist among these images, we assume low-dimensional geometry data structures (manifolds) are embedded in the high-dimensional space. Those manifolds might be hidden from radiologists because it is challenging for human experts to interpret high-dimensional data. Identification of the manifold is a critical step for successfully analyzing multimodal MR images.

We have developed various manifold learning algorithms (Tran et al. 2011; Tran et al. …


Plasma Processes And Cancer - Special Topical Cluster Of The 2nd Iwpct Meeting, Masaru Hori, Mounir Laroussi, Kai Masur, Yuzuru Ikehara 2015 Old Dominion University

Plasma Processes And Cancer - Special Topical Cluster Of The 2nd Iwpct Meeting, Masaru Hori, Mounir Laroussi, Kai Masur, Yuzuru Ikehara

Electrical & Computer Engineering Faculty Publications

(First paragraph) Although the emerging multidisciplinary field of plasma medicine has been around for nearly two decades important advances have already taken place that could one day revolutionize healthcare and the way various challenging diseases can be treated.1-3Amongst these advances the effects of low temperature plasma (LTP) on cancer cells in vitro and in vivo stand out.4-13Current cancer treatment modalities, such as chemotherapy and radiation therapy, have serious side effects and tend to lose their benefits to the patients after a while. Therefore, novel and improved therapies that can be used alone …


Spatio-Temporal Modeling Of Anatomic Motion For Radiation Therapy, Elizabeth Zachariah 2015 Virginia Commonwealth University

Spatio-Temporal Modeling Of Anatomic Motion For Radiation Therapy, Elizabeth Zachariah

Theses and Dissertations

In radiation therapy, it is imperative to deliver high doses of radiation to the tumor while reducing radiation to the healthy tissue. Respiratory motion is the most significant source of errors during treatment. Therefore, it is essential to accurately model respiratory motion for precise and effective radiation delivery. Many approaches exist to account for respiratory motion, such as controlled breath hold and respiratory gating, and they have been relatively successful. They still present many drawbacks. Thus, research has been expanded to tumor tracking.

The overall goal of 4D-CT is to predict tumor motion in real time, and this work attempts …


Multi-Surface Simplex Spine Segmentation For Spine Surgery Simulation And Planning, Rabia Haq 2015 Old Dominion University

Multi-Surface Simplex Spine Segmentation For Spine Surgery Simulation And Planning, Rabia Haq

Computational Modeling & Simulation Engineering Theses & Dissertations

This research proposes to develop a knowledge-based multi-surface simplex deformable model for segmentation of healthy as well as pathological lumbar spine data. It aims to provide a more accurate and robust segmentation scheme for identification of intervertebral disc pathologies to assist with spine surgery planning. A robust technique that combines multi-surface and shape statistics-aware variants of the deformable simplex model is presented. Statistical shape variation within the dataset has been captured by application of principal component analysis and incorporated during the segmentation process to refine results. In the case where shape statistics hinder detection of the pathological region, user-assistance is …


Nanopulse Generators: Their Design And Application To Cancer Therapy Studies, Daniel P. Wernig 2014 Liberty University

Nanopulse Generators: Their Design And Application To Cancer Therapy Studies, Daniel P. Wernig

Senior Honors Theses

Effective nanopulse generators have become critical in recent decades concerning the study of subcellular affects in response to nanosecond pulsed electric fields. It has been observed that nanosecond duration electric pulses can target intracellular organelles, ultimately leading to cell apoptosis, suggesting the possibility of a new, minimally invasive, low risk cancer therapy methodology. The standard topology for developing a medical nanopulser is the Blumlein “transmission line” approach. This approach relies on the nearly infinitesimal, yet finite amount of time required for an electromagnetic field to propagate down a short transmission line. Prior to design, requirements and constraints must be defined …


Shape/Image Registration For Medical Imaging : Novel Algorithms And Applications., Ahmed Magdy Shalaby 1982- 2014 University of Louisville

Shape/Image Registration For Medical Imaging : Novel Algorithms And Applications., Ahmed Magdy Shalaby 1982-

Electronic Theses and Dissertations

This dissertation looks at two different categories of the registration approaches: Shape registration, and Image registration. It also considers the applications of these approaches into the medical imaging field. Shape registration is an important problem in computer vision, computer graphics and medical imaging. It has been handled in different manners in many applications like shapebased segmentation, shape recognition, and tracking. Image registration is the process of overlaying two or more images of the same scene taken at different times, from different viewpoints, and/or by different sensors. Many image processing applications like remote sensing, fusion of medical images, and computer-aided surgery …


Induction Of Differentiation Of Dental Pulp-Derived Mesenchymal Stem Cells (Dpsc), Aubrey Young 2014 University of Nevada, Las Vegas

Induction Of Differentiation Of Dental Pulp-Derived Mesenchymal Stem Cells (Dpsc), Aubrey Young

UNLV Theses, Dissertations, Professional Papers, and Capstones

Mesenchymal stem cells are derived from a variety of human tissues and are being bioengineered and studied for possible uses in the advancement of medicine. Recent efforts are being focused on Dental Pulp Stem Cells (DPSC's) due to the accessibility of this tissue. Many factors influence DPSC quality and quantity, including the specific methods used to isolate, collect, concentrate, and store these isolates once they are removed. Ancillary factors, such as the choice of media, the selection of early versus late passage cells, and cryopreservation techniques may also influence the differentiation potential and proliferative capacity of DPSC isolates.

The objective …


Data Completion Methods For Improved Developmental Stage Annotation Of Drosophila Embryos In Images, Chitsanu Janyalikit 2014 Old Dominion University

Data Completion Methods For Improved Developmental Stage Annotation Of Drosophila Embryos In Images, Chitsanu Janyalikit

Electrical & Computer Engineering Theses & Dissertations

Drosophila melanogaster is a dominant model organism for studying the function of animal genes in initial stages of embryogenesis. Usually, images containing Drosophila gene expression patterns are captured at different developmental stages to study the interconnection of animal genes. To achieve most biologically meaningful results, gene expression images from a similar stage should be compared. Currently, biologists manually classify embryos in images into different stages, which is time intensive and infeasible for current massively produced gene expression images. Therefore, there is a need to develop an automatic system for the annotation.

Gene expression information in embryo images usually appears as …


Cited2-Mediated Mechanotransduction And Its Use For Chondroprotection, Daniel J. Leong 2014 CUNY Graduate Center

Cited2-Mediated Mechanotransduction And Its Use For Chondroprotection, Daniel J. Leong

Dissertations, Theses, and Capstone Projects

Novel prevention and therapeutic treatment for cartilage degradation is urgently called for, as cartilage degradation is a hallmark for arthritic diseases including osteoarthritis (OA) and rheumatoid arthritis (RA), and there is a high incidence of arthritis-related disability and high medical costs. While both underuse (e.g. physically inactive lifestyle) and overuse (e.g. high impact or intense repetitive joint use as seen in certain sports) are risk factors for cartilage degradation, recent studies highlight that dynamic moderate loading is associated with reduced incidence of developing OA. Exercise is prescribed in most cases at moderate levels for both OA and RA patients, and …


Detection Of Parkinson Disease Rest Tremor, Matthew J. Johnson 2014 Washington University in St. Louis

Detection Of Parkinson Disease Rest Tremor, Matthew J. Johnson

McKelvey School of Engineering Graduate Student Theses & Dissertations

Parkinson Disease (PD) is a debilitating and progressive movement disorder that is estimated to affect over six million worldwide. One of the most characteristic symptoms of PD is resting tremor, which involves unintentional and rhythmic muscle oscillations of an afflicted extremity while the muscles of said extremity are relaxed. This study involved measuring the rest tremor of 10 PD subjects, 10 Essential Tremor subjects, and 10 healthy control subjects using two devices. One device was an FDA approved accelerometry system to measure human tremor known as the TremorometerTM and the other was a consumer three-dimensional camera known as the …


Medical Applications Of Mrc, Kyle Thackston, Henry Mei, Pedro Irazoqui 2014 Purdue University

Medical Applications Of Mrc, Kyle Thackston, Henry Mei, Pedro Irazoqui

The Summer Undergraduate Research Fellowship (SURF) Symposium

Consistent powering is a limiting reagent for many medical implants and sensors. Powering in-vivo devices in animal studies requires either transcutaneous wiring (limiting mobility and increasing the chance of infection) or an implanted battery (limited lifetime and limits size of device). Wireless power transfer (WPT) would be able to overcome these challenges and permit the use of more advanced implantable devices in a research setting. Magnetic resonance coupling (MRC), an advanced form of inductive charging, allows good transfer efficiencies over significant air gaps, but works best a specific location and frequency, limiting mobility in animal studies. Using band-pass filter theory, …


Towards Highly-Integrated Stereovideoscopy For In Vivo Surgical Robots, Jay Carlson 2014 University of Nebraska-Lincoln

Towards Highly-Integrated Stereovideoscopy For In Vivo Surgical Robots, Jay Carlson

Department of Electrical and Computer Engineering: Dissertations, Theses, and Student Research

When compared to traditional surgery, laparoscopic procedures result in better patient outcomes: shorter recovery, reduced post-operative pain, and less trauma to incisioned tissue. Unfortunately, laparoscopic procedures require specialized training for surgeons, as these minimally-invasive procedures provide an operating environment that has limited dexterity and limited vision. Advanced surgical robotics platforms can make minimally-invasive techniques safer and easier for the surgeon to complete successfully. The most common type of surgical robotics platforms -- the laparoscopic robots -- accomplish this with multi-degree-of-freedom manipulators that are capable of a diversified set of movements when compared to traditional laparoscopic instruments. Also, these laparoscopic robots …


Design, Characterization And Application Of A Multiple Input Stethoscope Apparatus, Spencer Geng Wong 2014 California Polytechnic State University, San Luis Obispo

Design, Characterization And Application Of A Multiple Input Stethoscope Apparatus, Spencer Geng Wong

Master's Theses

For this project, the design, implementation, characterization, calibration and possible applications of a multiple transducer stethoscope apparatus were investigated. The multi-transducer sensor array design consists of five standard stethoscope diaphragms mounted to a rigid frame for a-priori knowledge of their relative spatial locations in the x-y plane, with compliant z-direction positioning to ensure good contact and pressure against the subject’s skin for reliable acoustic coupling. When this apparatus is properly placed on the body, it can digitally capture the same important body sounds investigated with standard acoustic stethoscopes; especially heart sounds. Acoustic signal inputs from each diaphragm are converted to …


Digital Commons powered by bepress