Using The Continuous Wavelet Transform To Characterize Differences Between Impact Signals From Non-Cleated And Cleated Turf Shoes,
2010
Boise State University
Using The Continuous Wavelet Transform To Characterize Differences Between Impact Signals From Non-Cleated And Cleated Turf Shoes, Wayne Robert Fischer
Boise State University Theses and Dissertations
The continuous wavelet transform was used to characterize the time-frequency differences between impact forces from non-cleated and cleated turf shoes among male football athletes who perform cut and run activities. This research is significant because it elucidates how athletes experience different impact force and torque frequency content based on the type of shoe they are wearing. The complex Morlet mother wavelet was used to analyze all ground reaction force and vertical ground reaction moment signals to create time-frequency power spectrum plots. For each signal, a statistical confidence interval was calculated and displayed along with the cone of influence caused by …
Finite Element Modeling Of Icd Lead Silicone Soft-Tips,
2010
California Polytechnic State University, San Luis Obispo
Finite Element Modeling Of Icd Lead Silicone Soft-Tips, Jose J. Lepe
Master's Theses
Although highly underutilized by the medical device industry, Finite Element Analysis (FEA) in the development of new technologies is gaining popularity as regulatory bodies such as the Food and Drug Administration (FDA) begin to require additional proof of safety through scientific methods. Non-linear FEA allows engineers to realistically simulate the mechanical behavior of implants as seen in the in-vitro, or in some cases, the in-vivo configurations. The work presented in this report investigates how computational methods can be used to simulate the interaction of a St. Jude Medical silicone soft-tip as it passes through a Peel-Away Sheath (i.e. introducer). In …
Effects Of Reamer-Femoral Component Offset On Cement Mantle Penetration In Hip Resurfacing Arthroplasty,
2010
California Polytechnic State University, San Luis Obispo
Effects Of Reamer-Femoral Component Offset On Cement Mantle Penetration In Hip Resurfacing Arthroplasty, Mark Lloyd Paulick
Master's Theses
Hip resurfacing arthroplasty has changed the treatment of end stage arthritis without severe deformity for young, active adults. Presently, there are varying clinical approaches to implant design selection and cementation techniques. The purpose of this project is to determine what amount of reamer-femoral component offset allows for the best cement penetration into the femoral head.
Rapid prototyped femoral component models were produced with reamer femoral component offsets of 0.0 mm, 0.5 mm, and 1.0 mm. After implantation onto models of reamed femoral heads made from high-density open-cell reticulated carbon foam, cement penetration was assessed from cross-sections of the foam-implant unit. …
Characterization And Physicochemical Modifications Of Polymer Hollow Fiber Membranes For Biomedical And Bioprocessing Applications,
2010
Utah State University
Characterization And Physicochemical Modifications Of Polymer Hollow Fiber Membranes For Biomedical And Bioprocessing Applications, Benjamin R. Madsen
All Graduate Theses and Dissertations, Spring 1920 to Summer 2023
Hollow fiber membranes (HFMs) formed through phase inversion methods exhibit specific physicochemical characteristics and generally favorable surface and mechanical properties, supporting their use in diverse applications including ultrafiltration, dialysis, cell culture, bioreactors, and tissue engineering. Characterization of, and modifications to, such membranes are important steps in achieving desired characteristics for specific applications.
HFMs subject to gas, irradiation, and chemical sterilization techniques were characterized based on several analytical techniques. It was revealed that these common sterilization techniques can cause inadvertent changes to HFM properties. While these changes may cause detrimental effects to HFMs used in filtration, the methods of sterilization are …
Effects Of Static Stretching On Foot Velocity During The Instep Soccer Kick,
2010
Utah State University
Effects Of Static Stretching On Foot Velocity During The Instep Soccer Kick, Craig D. Workman
All Graduate Theses and Dissertations, Spring 1920 to Summer 2023
The purpose of this study was to assess the acute effects of static stretching on foot velocity at impact with a soccer ball. Eighteen Division I female soccer athletes underwent two test conditions separated by 48 hr. Each condition was randomly assigned and began by placing four retro-reflective markers on bony landmarks of the ankle (total of eight markers, four on each ankle). One condition was the no-stretch condition, in which each participant performed a self-paced jog for 5 min as a warm-up, and then sat quietly for 6 min before performing three maximal instep kicks into a net. The …
A Synthetic Biological Engineering Approach To Secretion- Based Recovery Of Polyhydroxyalkanoates And Other Cellular Products,
2010
Utah State University
A Synthetic Biological Engineering Approach To Secretion- Based Recovery Of Polyhydroxyalkanoates And Other Cellular Products, Elisabeth Linton
All Graduate Theses and Dissertations, Spring 1920 to Summer 2023
The costs associated with cellular product recovery commonly account for as much as 80% of the total production expense. As a specific example, significant recovery costs limit commercial use of polyhydroxyalkanoates (PHA), which comprise a class of microbially-accumulated polyesters. PHAs are biodegradable compounds that are of interest as a sustainable alternative to petrochemically-derived plastics. Secretion-based recovery of PHAs was studied to decrease PHA production costs. Type I and II secretory pathways are commonly used for the translocation of recombinant proteins out of the cytoplasm of E. coli. Proteins were targeted for translocation using four signal peptides (HlyA, TorA, GeneIII, …
Comparative Studies On Oxygen Mass Transfer For The Design And Development Of A Single-Use Fermentor,
2010
Utah State University
Comparative Studies On Oxygen Mass Transfer For The Design And Development Of A Single-Use Fermentor, Kristan L. Sorenson
All Graduate Theses and Dissertations, Spring 1920 to Summer 2023
Accurate experimental oxygen mass transfer coefficient, a measure of how quickly oxygen travels from a gas bubble to the bulk liquid, is important for comparing performance and for evaluating the oxygen transfer capability of a fermentor. Delays in probe response and changing gas volumes upon start-up of gassing affect the accuracy of oxygen transfer measurements. To mitigate these inaccuracies, a standard correction procedure for oxygen mass transfer data was established for highly oxygenated, well-mixed fermentation systems. Probe response time correction was generated by applying a second-order response model to dissolved oxygen probes and shown to be effective within 4%. By …
Mineralization Potential Of Electrospun Pdo-Nha-Fibrinogen Scaffolds Intended For Cleft Palate Repair,
2010
Virginia Commonwealth University
Mineralization Potential Of Electrospun Pdo-Nha-Fibrinogen Scaffolds Intended For Cleft Palate Repair, Isaac Rodriguez
Theses and Dissertations
The overall goal of this study was to identify mineralized scaffolds which can serve as potential alternatives to bone graft substitutes intended for cleft palate repair. The aim of this preliminary study was to evaluate the role of fibrinogen (Fg) and nano-hydroxyapatite (nHA) in enhancing mineralization potential of polydioxanone (PDO) electrospun scaffolds. Scaffolds were fabricated by blending PDO:nHA:Fg in the following weight ratios: 100:0:0, 50:25:25, 50:50:0, 50:0:50, 0:0:100 and 0:50:50. Scaffolds were immersed in different simulated body fluids for 5 and 14 days to induce mineralization. The inclusion of fibrinogen induced sheet-like mineralization while individual fiber mineralization was noticed in …
Electrophysiological Analysis In An Animal Model Of Dystonia,
2010
Virginia Commonwealth University
Electrophysiological Analysis In An Animal Model Of Dystonia, Kunal Chaniary
Theses and Dissertations
Dystonia is a movement disorder characterized by patterned, repetitive, and sustained muscle contractions that cause ineffective and often painful movements. The overall goal of this project was to understand the physiological mechanisms of dystonia in a rodent model as a basis for developing innovative treatments for secondary dystonias. The first half of the project was focused at developing essential techniques for systematically investigating the movement disorder in these animals. For achieving this, an innovative, multi-faceted approach was pursued starting with electromyographic (EMG) analysis for animal model validation, gait analysis for dystonia quantification, and development of a novel stereotaxic apparatus for …
Synthesis Of An Endothelial Cell Mimicking Surface Containing Thrombomodulin And Endothelial Protein C Receptor,
2010
University of Nebraska-Lincoln
Synthesis Of An Endothelial Cell Mimicking Surface Containing Thrombomodulin And Endothelial Protein C Receptor, Karl E. Kador
Department of Chemical and Biomolecular Engineering: Dissertations, Theses, and Student Research
Synthetic materials for use in blood contacting applications have been studied for many years with limited success. One of the main areas of need for these materials is the design of synthetic vascular grafts for use in the hundreds of thousands of patients who have coronary artery bypass grafting, many without suitable veins for autologous grafts. The design of these grafts is constrained by two common modes of failure, the formation of intimal hyperplasia (IH) and thrombosis. IH formation has been previously linked to a mismatching of the mechanical properties of the graft and has been overcome by creating grafts …
Effect Of Loading Condition On Traction Coefficient Between Shoes And Artificial Turf Surfaces,
2010
Boise State University
Effect Of Loading Condition On Traction Coefficient Between Shoes And Artificial Turf Surfaces, Seth M. Kuhlman, Michelle B. Sabick, Ronald Pfeiffer, Benjamin Cooper, Jackie Forhan
Mechanical and Biomedical Engineering Faculty Publications and Presentations
Background. The interaction between a shoe and a turf surface is highly complex and difficult to characterize. Over the three decades since artificial turf was introduced, researchers have attempted to understand the traction caused by the interaction. However, some of the methodologies used for traction measurements have not capitalized on advances in currently available technology for testing and most testing conditions have not simulated realistic physiological loads.
Method of Approach. To assess the effect of test condition on traction results, the newly designed TurfBuster testing device was used to collect traction data on FieldTurf™ brand artificial turf under varying conditions. …
Dna Microarray Image Segmentation Using Active Contours Without Edges Method,
2010
Louisiana Tech University
Dna Microarray Image Segmentation Using Active Contours Without Edges Method, Shenghua Ni
Doctoral Dissertations
The goal of this dissertation is to build a better segmentation method for DNA microarray image processing. Segmentation is a partitioning process used to separate a spot area from a non-spot area in DNA microarrays. It directly affects the accuracy of gene expression analysis in the data mining process that follows. A number of DNA microarray segmentation methods have been proposed in the area, but even modern segmentation methods seem to have accuracy problems. In this dissertation, I will present a segmentation method based on the Active Contours Without Edges (ACWE) algorithm and apply it to two types of DNA …
Section Abstracts: Biomedical And General Engineering,
2010
Old Dominion University
Section Abstracts: Biomedical And General Engineering
Virginia Journal of Science
Abstracts of the Biomedical and General Engineering Section for the 88th Annual Meeting of the Virginia Academy of Science, May 20-21, 2010, James Madison University, Harrisonburg, VA.
Locked Plate Fixation Of Osteoporotic Humeral Shaft Fractures: Are Two Locking Screws Per Segment Enough?,
2010
University of Colorado at Denver and Health Sciences Center
Locked Plate Fixation Of Osteoporotic Humeral Shaft Fractures: Are Two Locking Screws Per Segment Enough?, David J. Hak, Peter Althausen, S J. Hazelwood
Biomedical Engineering
Objective: The purpose of this study was to compare the biomechanical behavior of using two versus three locking screws per bone segment in a cadaveric humerus fracture gap model.
Methods: Six matched pairs of elderly osteoporotic fresh–frozen human cadaveric humerii were used. An eight-hole locking compression plate was placed posteriorly on the humeral shaft and secured with either four or six bicortical locking screws. A 5-mm middiaphyseal gap osteotomy was created to simulate a comminuted fracture without bony contact. Specimens were tested in offset axial compression, four-point anteroposterior bending, four-point medial– lateral bending, and torsion. After the initial testing in …
Tracking Of Bone Mass And Density During Childhood And Adolescence,
2010
Wright State University - Main Campus
Tracking Of Bone Mass And Density During Childhood And Adolescence, Heidi J. Kalkwarf, Vicente Gilsanz, Joan M. Lappe, Sharon Oberfield, John A. Shepherd, Thomas N. Hangartner, Xangke Huang, Margaret M. Frederick, Karen K. Winer, Babette S. Zemel
Biomedical, Industrial & Human Factors Engineering Faculty Publications
Context: Whether a child with low bone mineral density (BMD) at one point in time will continue to have low BMD, despite continued growth and maturation, is important clinically. The stability of a characteristic during growth is referred to as “tracking.”
Objective: We examined the degree of tracking in bone mineral content (BMC) and BMD during childhood and adolescence and investigated whether tracking varied according to age, sexual maturation, and changes in growth status.
Design: We conducted a longitudinal study with measurements at baseline and annually for 3 yr.
Setting: The Bone Mineral Density in Childhood Study was conducted at …
Upper Extremity Kinetics During Lofstrand Crutch-Assisted Gait In Children,
2010
Marquette University
Upper Extremity Kinetics During Lofstrand Crutch-Assisted Gait In Children, Neha Bhagchandani
Master's Theses (2009 -)
Complete biomechanical analysis helps evaluate the motion during various gait patterns for the upper and lower extremities. Extensive studies have been performed to evaluate unassisted gait patterns, but very little has been accomplished for studying assisted motion. Children with pathologies such as osteogenesis imperfecta, spinal cord injury, and cerebral palsy use assistive devices such as anterior and posterior walkers, canes, Lofstrand and axillary crutches for ambulation purposes.
Statistics show that there are currently about 566,000 crutch users in the United States. The long-term crutch users in this population can suffer various upper limb pathologies associated with extensive upper extremity (UE) …
An Investigative Study Into The Relationship Of Bone Morphogenetic Protein Antagonist Expression And Osteocyte Density By Region And Quadrant,
2010
California Polytechnic State University, San Luis Obispo
An Investigative Study Into The Relationship Of Bone Morphogenetic Protein Antagonist Expression And Osteocyte Density By Region And Quadrant, Scott C. Mosher
Master's Theses
The role of cytokines and cell behavior and viability with respect to bone remodeling and bone behavior is an exciting area of orthopedic research. The purpose of this study was to investigate the relationships between BMP antagonist expression and osteocyte density, lacunar densities and osteocyte viability in cortical bone. Samples of unloaded tibial bone obtained from six C57Bl/6 mice were immunohistochemically stained for gremlin and noggin expression and also underwent methyl green staining to determine osteocyte presence. Bone sections were divided into four quadrants (cranial, caudal, medial and lateral) and three regions (proximal, mid shaft and distal), followed by analysis …
Characterization Of An Implicitly Resistively-Loaded Monopole Antenna In Lossy Liquid Media,
2010
Dartmouth College
Characterization Of An Implicitly Resistively-Loaded Monopole Antenna In Lossy Liquid Media, Colleen J. Fox, Paul M. Meaney, Fridon Shubitidze, Lincoln Potwin, Keith D. Paulsen
Dartmouth Scholarship
Abstract
Microwave tomographic imaging of the breast for cancer detection is a topic of considerable interest because of the potential to exploit the apparent high-dielectric property contrast between normal and malignant tissue. An important component in the realization of an imaging system is the antenna array to be used for signal transmission/detection. The monopole antenna has proven to be useful in our implementation because it can be easily and accurately modeled and can be positioned in close proximity to the imaging target with high-element density when configured in an imaging array. Its frequency response is broadened considerably when radiating in …
A Non-Rigid Registration Method For Analyzing Myocardial Wall Motion For Cardiac Ct Images,
2010
Marquette University
A Non-Rigid Registration Method For Analyzing Myocardial Wall Motion For Cardiac Ct Images, Elizabeth B. Philps
Master's Theses (2009 -)
Cardiac resynchronization therapy (CRT) has a high percentage of non-responders. Successfully locating the optimal location for CRT lead placement on a priori images can increase efficiency in procedural preparation and execution and could potentially increase the rate of CRT responders.
Registration has been used in the past to assess the motion of medical images. Specifically, one method of non-rigid registration has been utilized to assess the motion of left ventricular MR cardiac images. As CT imaging is often performed as part of resynchronization treatment planning and is a fast and accessible means of imaging, extending this registration method to assessing …
Bi-Planar Postural Stability Model: Fitting Parameters To Patient Data Automatically,
2010
Marquette University
Bi-Planar Postural Stability Model: Fitting Parameters To Patient Data Automatically, Andrew Michael Sovol
Master's Theses (2009 -)
Studies of children with cerebral palsy (CP) have shown that maintaining control of posture in quiet standing is often difficult. Physical therapy and assistive devices, both with or without surgery, may be employed in an effort to improve postural stability. Assessing the effectiveness of such interventions is important for healthcare providers and their patients. A previously created bi-planar model of posture control has been further developed as a method of assessment. This MATLAB and Simulink model has successfully replicated experimental results for typical adults and children, as well as children with CP across three different test conditions: eyes open, eyes …