Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

11,439 Full-Text Articles 22,480 Authors 5,680,319 Downloads 211 Institutions

All Articles in Biomedical Engineering and Bioengineering

Faceted Search

11,439 full-text articles. Page 380 of 470.

Relationships Of Long-Term Bisphosphonate Treatment With Measures Of Bone Microarchitecture And Mechanical Competence, Jonathan Joseph Ward 2014 University of Kentucky

Relationships Of Long-Term Bisphosphonate Treatment With Measures Of Bone Microarchitecture And Mechanical Competence, Jonathan Joseph Ward

Theses and Dissertations--Biomedical Engineering

Oral bisphosphonate drug therapy is a common and effective treatment for osteoporosis. Little is known about the long-term effects of bisphosphonates on bone quality. This study examined the structural and mechanical properties of trabecular bone following 0-16 years of bisphosphonate treatment. Fifty-three iliac crest bone samples of Caucasian women diagnosed with low turnover osteoporosis were identified from the Kentucky Bone Registry. Forty-five were treated with oral bisphosphonates for 1 to 16 years while eight were treatment naive. A section of trabecular bone was chosen from a micro-computed tomography (Scanco µCT 40) scan of each sample for a uniaxial linearly elastic …


Additives To Control Mechanical Properties And Drug Delivery Of Injectable Polymeric Scaffolds, Paul Fisher 2014 University of Kentucky

Additives To Control Mechanical Properties And Drug Delivery Of Injectable Polymeric Scaffolds, Paul Fisher

Theses and Dissertations--Biomedical Engineering

In situ forming implants (ISIs) are popular due to their ease of use and local drug delivery potential, but they suffer from high initial drug burst, and release behavior is tied closely to solvent exchange and polymer properties. Additionally, such systems are traditionally viewed purely as drug delivery devices rather than potential scaffold materials due to their poor mechanical properties and minimal porosity. The aim of this research was to develop an injectable ISI with drug release, mechanical, and microstructural properties controlled by micro- and nanoparticle additives.

First, an injectable ISI was developed with appropriate drug release kinetics for orthopedic …


Developing Genetic Tools For Geobacillus, Brittany Artale 2014 University of New Hampshire - Main Campus

Developing Genetic Tools For Geobacillus, Brittany Artale

Honors Theses and Capstones

Bacillus and Geobacillus are the primary bacterium used in biotechnology industries due to their ability to excrete extracellular materials such as proteins, enzymes and other byproducts. Bacillus subtilis, has a well-characterized competence machinery, giving way to characterized genetic tools. However, a significant problem associated with working with Bacillus is the regulation of endospore formation. An alternative to Bacillus is Geobacillus, a thermophilic bacterium. Thermophiles offer significant advantages over other bacteria as host organisms in biofuel, bioremediation, and biocatalyst processes. However, the genetic tools and competency associated with Geobacillus is still unknown. Through, genetic engineering the ability …


Inorganic Biodegradable Devices For Temporary Implants, Kassan Unda 2014 Missouri University of Science and Technology

Inorganic Biodegradable Devices For Temporary Implants, Kassan Unda

Masters Theses

"Implantable electronic devices have great potential to benefit many health care technologies. They comprise of two different categories. The first is permanent prosthetic devices like cardiac pacemakers or nerve stimulants. The other category includes temporary devices for interventional medical monitoring and control scenarios, which lose functionality and become unnecessary after their intended operational lifetime. This can cause serious electromagnetic and biomechanical safety concerns if not removed from the body by an additional surgical operation.

This thesis focuses on exploring the feasibility of implantable inorganic bioresorbable thin film resistive devices utilizing bioactive glass as the core structural material. This device will …


Cervical Cancer Histology Image Feature Extraction And Classification, Peng Guo 2014 Missouri University of Science and Technology

Cervical Cancer Histology Image Feature Extraction And Classification, Peng Guo

Masters Theses

"Cervical cancer, the second most common cancer affecting women worldwide and the most common in developing countries can be cured if detected early and treated. Expert pathologists routinely visually examine histology slides for cervix tissue abnormality assessment. In previous research, an automated, localized, fusion-based approach was investigated for classifying squamous epithelium into Normal, CIN1, CIN2, and CIN3 grades of cervical intraepithelial neoplasia (CIN) based on image analysis of 62 digitized histology images obtained through the National Library of Medicine. In this research, CIN grade assessments from two pathologists are analyzed and are used to facilitate atypical cell concentration feature development …


Utilizing Dielectrophoresis To Determine The Physiological Differences Of Eukaryotic Cells, Tayloria Nicole Gail Adams 2014 Michigan Technological University

Utilizing Dielectrophoresis To Determine The Physiological Differences Of Eukaryotic Cells, Tayloria Nicole Gail Adams

Dissertations, Master's Theses and Master's Reports - Open

Type 1 diabetes affects over 108,000 children, and this number is steadily increasing. Current insulin therapies help manage the disease but are not a cure. Over a child’s lifetime they can develop kidney disease, blindness, cardiovascular disease and many other issues due to the complications of type 1 diabetes. This autoimmune disease destroys beta cells located in the pancreas, which are used to regulate glucose levels in the body. Because there is no cure and many children are affected by the disease there is a need for alternative therapeutic options that can lead to a cure.

Human mesenchymal stem cells …


A Backing Device Based On An Embedded Stiffener And Retractable Insertion Tool For Thin-Film Cochlear Arrays, Radheshyam Tewari 2014 Michigan Technological University

A Backing Device Based On An Embedded Stiffener And Retractable Insertion Tool For Thin-Film Cochlear Arrays, Radheshyam Tewari

Dissertations, Master's Theses and Master's Reports - Open

Intracochlear trauma from surgical insertion of bulky electrode arrays and inadequate pitch perception are areas of concern with current hand-assembled commercial cochlear implants. Parylene thin-film arrays with higher electrode densities and lower profiles are a potential solution, but lack rigidity and hence depend on manually fabricated permanently attached polyethylene terephthalate (PET) tubing based bulky backing devices. As a solution, we investigated a new backing device with two sub-systems. The first sub-system is a thin poly(lactic acid) (PLA) stiffener that will be embedded in the parylene array. The second sub-system is an attaching and detaching mechanism, utilizing a poly(N-vinylpyrrolidone)-block-poly(d,l-lactide) (PVP-b-PDLLA) copolymer-based …


Design And Application Of Wireless Passive Magnetoelastic Resonance And Magnetoharmonic Force Sensors, Brandon D. Pereles 2014 Michigan Technological University

Design And Application Of Wireless Passive Magnetoelastic Resonance And Magnetoharmonic Force Sensors, Brandon D. Pereles

Dissertations, Master's Theses and Master's Reports - Open

The objective of the work described in this dissertation is the development of new wireless passive force monitoring platforms for applications in the medical field, specifically monitoring lower limb prosthetics. The developed sensors consist of stress sensitive, magnetically soft amorphous metallic glass materials. The first technology is based on magnetoelastic resonance. Specifically, when exposed to an AC excitation field along with a constant DC bias field, the magnetoelastic material mechanically vibrates, and may reaches resonance if the field frequency matches the mechanical resonant frequency of the material. The presented work illustrates that an applied loading pins portions of the strip, …


Fabrication Of Drug Eluting Ti Implants For Dental/Orthopedic Applications, Azhang Hamlekhan 2014 Michigan Technological University

Fabrication Of Drug Eluting Ti Implants For Dental/Orthopedic Applications, Azhang Hamlekhan

Dissertations, Master's Theses and Master's Reports - Open

Titanium and its alloys are typically used for fabrication of dental and orthopedic implants as they possess various desirable properties including biocompatibility and corrosion resistance. In spite of such benefits, titanium implants show lack of osseointegration after surgery in minor cases. The objective of this research has been to modify the surface of titanium alloy for medical applications through increasing surface hydrophilicity and drug loading. Primarily, anodization method is employed for fabrication of nanotubes on titanium surface to act as anchoring cite for cells.

Considering the key role of surface hydrophilicity on cellular attachment to the surface and subsequent biological …


Biomechanical Analysis Of Concealed Pack Load Influences On Terrorist Gait Signatures Derived From Gröbner Basis Theory, Sean S. Kohles, Anum Barki, Kimberly D. Kendricks, Ronald F. Tuttle 2014 Portland State University

Biomechanical Analysis Of Concealed Pack Load Influences On Terrorist Gait Signatures Derived From Gröbner Basis Theory, Sean S. Kohles, Anum Barki, Kimberly D. Kendricks, Ronald F. Tuttle

Biology Faculty Publications and Presentations

This project examines kinematic gait parameters as forensic predictors of the influence associated with individuals carrying concealed weighted packs up to 20% of their body weight. An initial inverse dynamics approach combined with computational algebra provided lower limb joint angles during the stance phase of gait as measured from 12 human subjects during normal walking. The following paper describes the additional biomechanical analysis of the joint angle data to produce kinetic and kinematic parameters further characterizing human motion. Results include the rotational velocities and accelerations of the hip, knee, and ankle as well as inertial moments and kinetic energies produced …


Novel Computational Approaches Characterizing Knee Physiotherapy, Wangdo Kim, Antonio P. Veloso, Duarte Araújo, Sean S. Kohles 2014 Universidade de Lisboa

Novel Computational Approaches Characterizing Knee Physiotherapy, Wangdo Kim, Antonio P. Veloso, Duarte Araújo, Sean S. Kohles

Biology Faculty Publications and Presentations

A knee joint’s longevity depends on the proper integration of structural components in an axial alignment. If just one of the components is abnormally off-axis, the biomechanical system fails, resulting in arthritis. The complexity of various failures in the knee joint has led orthopedic surgeons to select total knee replacement as a primary treatment. In many cases, this means sacrificing much of an otherwise normal joint. Here, we review novel computational approaches to describe knee physiotherapy by introducing a new dimension of foot loading to the knee axis alignment producing an improved functional status of the patient. New physiotherapeutic applications …


Evaluation Of Tissue-Engineered Tendon Enthesis Polymer Constructs, Joshua A. Bundy BS, Mary Beth Wade PhD, Hitomi Nakao MD, Phillip McClellan PhD, Qing Yu PhD, Robin Jacquet-Childs MS, William J. Landis PhD 2014 The University of Akron

Evaluation Of Tissue-Engineered Tendon Enthesis Polymer Constructs, Joshua A. Bundy Bs, Mary Beth Wade Phd, Hitomi Nakao Md, Phillip Mcclellan Phd, Qing Yu Phd, Robin Jacquet-Childs Ms, William J. Landis Phd

Williams Honors College, Honors Research Projects

Both scientists and clinicians have proposed tissue engineering as the future of medicine. The possibilities for tissue engineering, that is, fabrication of tissues and organs in the laboratory and their translation to patients, appear to be endless, and many believe that this new approach in medicine will result in abolishing many common ailments, injuries, and congenital defects. Injuries to a tendon enthesis, the normal tissue connection between tendon and bone, are of particular concern to clinicians because of their frequency and failure to repair as a result of surgery. While these injuries may not be life threatening, they can certainly …


Apelin Regulation Of K-Cl Cotransport In Vascular Smooth Muscle Cells., Neelima Sharma 2014 Wright State University

Apelin Regulation Of K-Cl Cotransport In Vascular Smooth Muscle Cells., Neelima Sharma

Browse all Theses and Dissertations

Atherosclerosis and high circulating levels of oxidized low density lipoproteins (oxLDL) are considered among the most important risk factors for the occurrence and development of cardiovascular disease (CVD). During the atherosclerotic lesion repair, phenotypic transition of vascular smooth muscle cells (VSMCs) from contractile to synthetic states plays a central role. In this process, enhanced proliferation/migration of VSMCs, from the tunica media to the intima, is required to sustain blood vessel endothelium integrity, and for inducing vessel wall remodeling in response to injury. At the molecular level, the activity of electroneutral potassium-chloride cotransporters or KCCs, is necessary to: a) allow changes …


A Compact Theory Of Magnetic Nerve Stimulation: Predicting How To Aim, Charles F. Babbs 2014 Purdue University

A Compact Theory Of Magnetic Nerve Stimulation: Predicting How To Aim, Charles F. Babbs

Weldon School of Biomedical Engineering Faculty Publications

Background: A compact theory that predicts quantitatively when and where magnetic neurostimulation will occur is needed as a guide to therapy, ideally providing a single equation that defines the target volume of tissue excited by single or dual coils. Methods: A first-principles analysis of magnetic stimulation incorporating a simplified description of electromagnetic fields and a simplified cable theory of the axon yields a mathematical synthesis predicting how to aim. Results: Nerve stimulation produced by a single circular coil having one or more closely packed turns occurs in donut shaped volume of tissue beneath the coil. Axons spanning several millimeters are …


Noninvasive Measurement Of Cardiac Stroke Volume Using Pulse Wave Velocity And Aortic Dimensions: A Simulation Study, Charles F. Babbs 2014 Purdue University

Noninvasive Measurement Of Cardiac Stroke Volume Using Pulse Wave Velocity And Aortic Dimensions: A Simulation Study, Charles F. Babbs

Weldon School of Biomedical Engineering Faculty Publications

Background: Concerns about the cost-effectiveness of invasive hemodynamic monitoring in critically ill patients using pulmonary artery catheters motivate a renewed search for effective noninvasive methods to measure stroke volume. This paper explores a new approach based on noninvasively measured pulse wave velocity, pulse contour, and ultrasonically determined aortic cross sectional area. Methods: The Bramwell-Hill equation relating pulse wave velocity to aortic compliance is applied. At the time point on the noninvasively measured pulse contour, denoted th, when pulse amplitude has fallen midway between systolic and diastolic values, the portion of stroke volume remaining in the aorta, and in turn the …


Choosing Inclusion Criteria That Minimize The Time And Cost Of Clinical Trials, Charles F. Babbs 2014 Purdue University

Choosing Inclusion Criteria That Minimize The Time And Cost Of Clinical Trials, Charles F. Babbs

Weldon School of Biomedical Engineering Faculty Publications

AIM: To present statistical tools to model and optimize the cost of a randomized clinical trial as a function of the stringency of patient inclusion criteria. METHODS: We consider a two treatment, dichotomous outcome trial that includes a proportion of patients who are strong responders to the tested intervention. Patients are screened for inclusion using an arbitrary number of test results that are combined into an aggregate suitability score. The screening score is regarded as a diagnostic test for the responsive phenotype, having a specific cutoff value for inclusion and a particular sensitivity and specificity. The cutoff is a measure …


The Application Of Graphene Films In Biosensing And Electrowetting, Xuebin Tan 2014 Wayne State University

The Application Of Graphene Films In Biosensing And Electrowetting, Xuebin Tan

Wayne State University Dissertations

In recent years, graphene has been found to possess extraordinary electronic, optical, mechanical and electrochemical properties. Graphene is optically transparent and mechanically flexible, and has high electron mobility and conductivity. In this thesis, we propose to investigate graphene's properties in the detection of biomolecules as well as the manipulation of biological samples. Graphene without defects has high charge carrier mobility and surface areas, which is ideal for biosensors. However, literature shows a lot of variations in the measurements using graphene biosensors. In addition, the surface functionalization of graphene in order to enhance the specificity has not been fully investigated yet. …


High-Performance Accelerometer Based On Asymmetric Gapped Cantilevers For Physiological Acoustic Sensing, Yating Hu 2014 Wayne State University

High-Performance Accelerometer Based On Asymmetric Gapped Cantilevers For Physiological Acoustic Sensing, Yating Hu

Wayne State University Dissertations

Continuous or mobile monitoring of physiological sounds is expected to play important role in the emerging mobile healthcare field. Because of the miniature size, low cost, and easy installation, accelerometer is an excellent choice for continuous physiological acoustic signal monitoring. However, in order to capture the detailed information in the physiological signals for clinical diagnostic purpose, there are more demanding requirements on the sensitivity/noise performance of accelerometers. In this thesis, a unique piezoelectric accelerometer based on the asymmetric gapped cantilever which exhibits significantly improved sensitivity is extensively studied. A meso-scale prototype is developed for capturing the high quality cardio and …


Tissue Engineering Scaffold Fabrication And Processing Techniques To Improve Cellular Infiltration, Casey Grey 2014 Virginia Commonwealth University

Tissue Engineering Scaffold Fabrication And Processing Techniques To Improve Cellular Infiltration, Casey Grey

Theses and Dissertations

Electrospinning is a technique used to generate scaffolds composed of nano- to micron-sized fibers for use in tissue engineering. This technology possesses several key weaknesses that prevent it from adoption into the clinical treatment regime. One major weakness is the lack of porosity exhibited in most electrospun scaffolds, preventing cellular infiltration and thus hosts tissue integration. Another weakness seen in the field is the inability to physically cut electrospun scaffolds in the frontal plane for subsequent microscopic analysis (current electrospun scaffold analysis is limited to sectioning in the cross-sectional plane). Given this it becomes extremely difficult to associate spatial scaffold …


Evaluation Of Functional Near Infrared Spectroscopy (Fnirs) For Assessment Of The Visual And Motor Cortices In Adults, Brenna Giacherio 2014 Wright State University

Evaluation Of Functional Near Infrared Spectroscopy (Fnirs) For Assessment Of The Visual And Motor Cortices In Adults, Brenna Giacherio

Browse all Theses and Dissertations

Introduction: Functional near-infrared spectroscopy (fNIRS) is a relatively young technique in the field of medical imaging. As such, it has yet to be widely implemented for clinical use, despite its promising advantages. However, unlike fMRI-its much bulkier and costly counterpart-fNIRS has yet to be proven as a standalone imaging tool within a clinical setting, particularly that of ophthalmology or physical therapy.

Methods: Ten healthy young adults (23.8 ± 4.8 years) participated in the study. Activation of the visual cortex was achieved utilizing various reversing checkerboard stimuli across three data collection sessions for each participant. Further, activation of the motor cortex …


Digital Commons powered by bepress