Development And Validation Of A Novel Resonant Energy Transfer (Fret) Biosensor To Measure Tensile Forces At The Linc Complex In Live Cells,
2017
Virginia Commonwealth University
Development And Validation Of A Novel Resonant Energy Transfer (Fret) Biosensor To Measure Tensile Forces At The Linc Complex In Live Cells, Paul Arsenovic
Theses and Dissertations
There is a large body of evidence supporting the theory that cell physiology largely depends on the mechanical properties of its surroundings or micro-environment. More recently studies have shown that changes to intra-cellular mechanical properties can also have a meaningful impact on cell function and in some cases lead to the progression of ailments or disease. For example, small changes to the protein sequence of a structural nuclear envelope protein called lamin-A is known to cause a variety of neurological and musculoskeletal diseases referred to as laminopathies. Currently, there is little incite into how these mutations lead to disease progression …
Electrospraying Extracellular Matrix To Form Nanoparticles,
2017
Virginia Commonwealth University
Electrospraying Extracellular Matrix To Form Nanoparticles, Patrick Link
Theses and Dissertations
Chronic Obstructive Pulmonary Disease (COPD) is a leading cause of death worldwide. Alveolar wall destruction is a significant contributor to COPD. Inflammatory macrophages are a major source of the Extracellular Matrix (ECM) proteolysis. ECM breakdown causes air to get trapped in the alveoli, obstructing airflow. One step in curing COPD may be to convert inflammatory to pro-regenerative macrophages. Recently, decellularized ECM scaffolds have shown the ability to induce a pro-regenerative phenotype.
Yet these scaffolds are incapable for reaching the alveolar region of the lungs. To reach the alveolar region particles need a diameter of 1-5 μm or smaller than 300 …
The Effect Of Vibrotactile Feedback On Remote Manual Task Performance,
2017
Virginia Commonwealth University
The Effect Of Vibrotactile Feedback On Remote Manual Task Performance, Matthew S. Standard
Theses and Dissertations
Vibrotactile feedback offers a unique opportunity to augment or reconstruct impaired tactile sensations, whether that be in the form of enhancing prosthetics or specialized protective clothing. Important information about temperature and object slippage serve to endanger the human operator or equipment. This thesis presents three experiments which investigate amplitude modulated vibrotactile signals as a scalar dimension of roughness, the effect those signals and their locations (finger pad, forearm, bicep) have on the performance of two tasks: the sensing of temperatures simulated by vibrotactile signals and gripping an object of simulated surface texture. The results show task performance increase when the …
Altering A Runner’S Foot Strike Using A Modified Elliptical Trainer,
2017
Virginia Commonwealth University
Altering A Runner’S Foot Strike Using A Modified Elliptical Trainer, Daniel Shull
Theses and Dissertations
One possible solution to common running related injuries is to transition runners from a rearfoot strike during initial contact to a midfoot strike. Natural rearfoot strike runners were studied to see if a modified elliptical trainer could be used to alter their running pattern to that of a midfoot strike runner. Their results were compared to subjects who ran on a non-modified elliptical trainer. After training on the modified elliptical trainer, subjects demonstrated a decrease in foot angle at initial contact when attempting to run with a midfoot strike. Training did not affect all kinetic metrics or stride frequency. However, …
The Effect Of Twist On The Mechanical Properties Of The Intervertebral Disc,
2017
Wilfrid Laurier University
The Effect Of Twist On The Mechanical Properties Of The Intervertebral Disc, Maxine Harvey-Burgess
Theses and Dissertations (Comprehensive)
Introduction: Intervertebral disc (IVD) herniation is a common injury to the IVD and a frequent source of low back pain. IVD herniation occurs when the nucleus pulposus migrates through both the inter- and intralamellar matrices of the annulus fibrosus (AF). There are a number of mechanical risk factors associated with herniation, including repetitive flexion and twist. In vivo, twist combined with repetitive flexion has been associated with increased experience of low back pain and herniation. Additionally, in vitro, when repetitive flexion is combined with twist, IVD herniation occurs more easily than repetitive flexion alone. However, the mechanisms behind …
Design Of A Fine-Needle Aspiration Biopsy Device For Thyroid Nodules,
2017
Andrews University
Design Of A Fine-Needle Aspiration Biopsy Device For Thyroid Nodules, Troy Furst, Christa Spieth, Gunnar Lovhoiden, Michael Spieth
Posters, Presentations, and Papers
While other devices currently exist to assist in FNA biopsies, none remove the repetitive whole wrist or arm movements needed to collect the sample.
Effects Of Training Intensity On Locomotor Performance In Individuals With Chronic Spinal Cord Injury: A Randomized Crossover Study,
2017
Rehabilitation Institute of Chicago
Effects Of Training Intensity On Locomotor Performance In Individuals With Chronic Spinal Cord Injury: A Randomized Crossover Study, Gabrielle Brazg, Meghan Fahey, Carey L. Holleran, Mark Connolly, Jane Woodward, Patrick W. Hennessy, Brian D. Schmit, T. George Hornby
Biomedical Engineering Faculty Research and Publications
Background. Many physical interventions can improve locomotor function in individuals with motor incomplete spinal cord injury (iSCI), although the training parameters that maximize recovery are not clear. Previous studies in individuals with other neurologic injuries suggest the intensity of locomotor training (LT) may positively influence walking outcomes. However, the effects of intensity during training of individuals with iSCI have not been tested. Objective. The purpose of this pilot, blinded-assessor randomized trial was to evaluate the effects of LT intensity on walking outcomes in individuals with iSCI. Methods. Using a crossover design, ambulatory participants with iSCI >1 year duration performed either …
A Wireless, Passive Sensor For Measuring Temperature At Orthopedic Implant Sites For Early Diagnosis Of Infections,
2017
Michigan Technological University
A Wireless, Passive Sensor For Measuring Temperature At Orthopedic Implant Sites For Early Diagnosis Of Infections, Salil Sidharthan Karipott
Dissertations, Master's Theses and Master's Reports
Sensorized implants with embedded wireless, passive temperature sensors were developed for early detection of implant-associated infections. The operation principle of the sensor is based on the hypothesis that infections can lead to an increase in local temperature prior to the rise of body temperature. The sensor was an inductive capacitive (LC) circuit that has been used for monitoring of different parameters wirelessly, often in difficult to access environments. The sensor was fabricated on to an interference screw, which is used for tendon and ligament reconstruction surgeries. In this project, a sensorized interference screw was designed and fabricated by accommodating an …
Implantable Wireless Sensor Networks: Application To Measuring Temperature For In Vivo Detection Of Infections,
2017
Michigan Technological University
Implantable Wireless Sensor Networks: Application To Measuring Temperature For In Vivo Detection Of Infections, Praharsh Madappaly Veetil
Dissertations, Master's Theses and Master's Reports
It is has been proven that infection in the body cause a local temperature increase due to localized inflammation. Therefore, a method to provide early diagnostic or long-term tracking of this infection will provide great benefits to patients with diabetic foot ulcers or sickle cell disease, and those receiving hemodialysis where they suffer from a weakened immune system. The goal of this project is to develop an implantable wireless temperature sensor based on a wireless sensor network system for monitoring infections in situ. The analog signals from the thermistors are digitized and wirelessly transmitted to a computer with an ez430-rf2500 …
A 3d Biomimetic Scaffold Using Electrospinning For Tissue Engineering Applications,
2017
Michigan Technological University
A 3d Biomimetic Scaffold Using Electrospinning For Tissue Engineering Applications, Samerender Nagam Hanumantharao
Dissertations, Master's Theses and Master's Reports
Electrospinning holds great promise for designing functional 3D biomimetic scaffolds for tissue engineering applications. The technique allows for the reproducible fabrication of 3D scaffolds with control over the porosity and thickness. In this work, a novel method for the synthesis of a 3D electroactive scaffold using electrospinning from polycaprolactone (PCL), Polyvinylidene Fluoride (PVDF) and Polyaniline (PANI) is reported. Additional scaffolds involving different morphologies of PCL, PCL-PVDF and PCL-PANI-PVDF were also fabricated and evaluated. The scaffolds were characterized using electron microscopy to visualize the morphologies. Infrared spectroscopy was used to confirm the presence of polymers and their respective phases in the …
Structural Characteristics And Corrosion Behavior Of Bio-Degradable Zn-Li Alloys In Stent Application,
2017
Michigan Technological University
Structural Characteristics And Corrosion Behavior Of Bio-Degradable Zn-Li Alloys In Stent Application, Shan Zhao
Dissertations, Master's Theses and Master's Reports
Zinc has begun to be studied as a bio-degradable material in recent years due to its excellent corrosion rate and optimal biocompatibility. Unfortunately, pure Zn’s intrinsic ultimate tensile strength (UTS; below 120 MPa) is lower than the benchmark (about 300 MPa) for cardiovascular stent materials, raising concerns about sufficient strength to support the blood vessel. Thus, modifying pure Zn to improve its mechanical properties is an important research topic.
In this dissertation project, a new Zn-Li alloy has been developed to retain the outstanding corrosion behavior from Zn while improving the mechanical characteristics and uniform biodegradation once it is implanted …
Skintronics: Wireless, Skin-Wearable Electronics For Monitoring Of Electrocardiogram,
2017
Virginia Commonwealth University
Skintronics: Wireless, Skin-Wearable Electronics For Monitoring Of Electrocardiogram, Matthew B. Piper, Woon-Hong Yeo, Yongkuk Lee
Undergraduate Research Posters
The ECGs I micro-fabricate are designed to be flexible, stretchable and wireless circuits that can be applied to the skin directly. The device is encased in a conformal, silicon-like substrate, that allows the ECG to be attached with the electrodes. Each electrode has been previously measured and verified that it will be correctly placed for an accurate reading. Prototyping this ECG/electrode device allows the user to mount the prototype directly to the patient without having to attach and wire ten other electrodes. This prototype solves the issue that comes about when a doctor, nurse or emergency medical technician must attach …
Shear Driven Micro-Fluidic Pump,
2016
Minnesota State University, Mankato
Shear Driven Micro-Fluidic Pump, Nihad E. Daidzic
Aviation Department Publications
United States Patent, Patent Number US 9,528,503 B2, Date of Patent December 27, 2016.
An example includes an apparatus to pump a fluid. The apparatus includes a housing extending along a length defining an elongate interior, an actuator in the housing, conforming to the elongate interior, the actuator including a plurality of lumens, each having a length extending substantially parallel to the elongate interior, each from around 10 to 200 micrometers across and an actuator configured to oscillate the actuator in the actuator houslng along the length of the elongate interior with a rate differential between movement in a first …
Mannequin Challenge | Biological Engineering,
2016
Utah State University
Mannequin Challenge | Biological Engineering, Usu College Of Engineering
College of Engineering News
Who says that learning about the various properties of Biomaterials is boring? Clearly, they haven't taken Dr. Yu Huang's BENG 2330 Properties of Biomaterials course. Not only do these students know how to distinguish the differences between natural and synthetic biomaterials.They know how to have a good time bringing the mannequin challenge into their lab clean up.
Differential Protein Adsorption And Cellular Uptake Of Silica Nanoparticles Based On Size And Porosity,
2016
Missouri University of Science and Technology
Differential Protein Adsorption And Cellular Uptake Of Silica Nanoparticles Based On Size And Porosity, Jiban Saikia, Mostafa Yazdimamaghani, Seyyed Pouya Hadipour Moghaddam, Hamidreza Ghandehari
Chemical and Biochemical Engineering Faculty Research & Creative Works
Slight alterations in nanoparticles' surface properties can significantly influence the corona composition which may alter their interaction with the biological milieu. Size and porosity of silica nanoparticles (SNPs) are known to be predominant factors influencing their dose-dependent toxicity. Little is known however about the extent and type of protein adsorption on SNPs as a function of physicochemical properties and the role this might play on mechanisms of cellular uptake and toxicity. In this work we investigated the influence of size and porosity of SNPs on protein adsorption, cellular uptake, and toxicity in RAW 264.7 macrophages. Toxicity of the SNPs was …
Overexpression Of Timp-3 In Chondrocytes Produces Transient Reduction In Growth Plate Length But Permanently Reduces Adult Bone Quality And Quantity,
2016
Florida Institute of Technology
Overexpression Of Timp-3 In Chondrocytes Produces Transient Reduction In Growth Plate Length But Permanently Reduces Adult Bone Quality And Quantity, Blandine Poulet, Ke Liu, Darren A. Plumb, Phoung Vo, Mittal Shah, Katherine Ann Staines, Alexandra Sampson, Hiroyuke Nakamura, Hideaki Nagase, Alessandra Carriero, Sandra J. Shefelbine, Andrew A. Pitsillides, George Bou-Gharios
Biomedical Engineering and Sciences Faculty Publications
Bone development and length relies on the growth plate formation, which is dependent on degradative enzymes such as MMPs. Indeed, deletion of specific members of this enzyme family in mice results in important joint and bone abnormalities, suggesting a role in skeletal development. As such, the control of MMP activity is vital in the complex process of bone formation and growth. We generated a transgenic mouse line to overexpress TIMP3 in mouse chondrocytes using the Col2a1-chondrocyte promoter. This overexpression in cartilage resulted in a transient shortening of growth plate in homozygote mice but bone length was restored at eight weeks …
Activity Preservation Of Plasmonic Biosensors With A Metal-Organic Framework,
2016
Washington University in St. Louis
Activity Preservation Of Plasmonic Biosensors With A Metal-Organic Framework, Lu Wang
McKelvey School of Engineering Graduate Student Theses & Dissertations
Antibody-antigen recognition enables antibody-conjugated nanostructures to serve as plasmonic biosensors with tunable specificity. However due to the instability of antibodies, these biosensors are susceptible to changes in the environment such as heat and aridity, leading to constraints on the transportation and handling of these sensors. Here we establish a method using a metal-organic framework crystal to preserve biosensor activity under severe environmental conditions, including exposure to high temperatures, an organic solvent and a proteolytic agent. After zeolitic imidazolate framework-8 (ZIF-8) crystals formed for 12 hours on a biosensor of gold nanorods conjugated with a model antibody, rabbit IgG, 80% of …
The Quantum Biology Of Reactive Oxygen Species Partitioning Impacts Cellular Bioenergetics,
2016
Florida Institute of Technology
The Quantum Biology Of Reactive Oxygen Species Partitioning Impacts Cellular Bioenergetics, Robert J. Usselman, Cristina Chavarriaga, Pablo R. Castello, Maria Procopio, Thorsten Ritz, Edward A. Dratz, David John Singel, Carlos F. Martino
Biomedical Engineering and Sciences Faculty Publications
Quantum biology is the study of quantum effects on biochemical mechanisms and biological function. We show that the biological production of reactive oxygen species (ROS) in live cells can be influenced by coherent electron spin dynamics, providing a new example of quantum biology in cellular regulation. ROS partitioning appears to be mediated during the activation of molecular oxygen (O2) by reduced flavoenzymes, forming spin-correlated radical pairs (RPs). We find that oscillating magnetic fields at Zeeman resonance alter relative yields of cellular superoxide (O2•−) and hydrogen peroxide (H2O2) ROS products, indicating coherent singlet-triplet mixing at the point of ROS formation. Furthermore, …
Finite Element Simulation And Additive Manufacturing Of Stiffness-Matched Niti Fixation Hardware For Mandibular Reconstruction Surgery,
2016
The University of Toledo
Finite Element Simulation And Additive Manufacturing Of Stiffness-Matched Niti Fixation Hardware For Mandibular Reconstruction Surgery, Ahmadreza Jahadakbar, Narges Shayesteh Moghaddam, Amirhesam Amerinatanzi, David Dean, Haluk E. Karaca, Mohammad Elahinia
Mechanical Engineering Faculty Publications
Process parameters and post-processing heat treatment techniques have been developed to produce both shape memory and superelastic NiTi using Additive Manufacturing. By introducing engineered porosity, the stiffness of NiTi can be tuned to the level closely matching cortical bone. Using additively manufactured porous superelastic NiTi, we have proposed the use of patient-specific, stiffness-matched fixation hardware, for mandible skeletal reconstructive surgery. Currently, Ti-6Al-4V is the most commonly used material for skeletal fixation devices. Although this material offers more than sufficient strength for immobilization during the bone healing process, the high stiffness of Ti-6Al-4V implants can cause stress shielding. In this paper, …
Design Of A Modified Stewart Platform Manipulator For Misalignment Correction,
2016
Bowling Green State University
Design Of A Modified Stewart Platform Manipulator For Misalignment Correction, Adekunle Ayoko
Master of Technology Management Plan II Graduate Projects
This thesis work is about the design of a modified Stewart platform manipulator for misalignment correction. The common version of the Stewart platform uses six actuators. The traditional Stewart platform of this kind has a moving top plate and a fixed base plate. However, in this research, the modified design of the traditional Stewart platform is studied. It is designed to be an easy connect-disconnect platform that can wrap around different structures with different cross sections and symmetrically designed. It is able to adjust position easily by using four identical but independent linear actuators populated evenly in two parts fastened …
