Parkinson's Freezing Of Gait Device Attachment,
2019
California Polytechnic State University, San Luis Obispo
Parkinson's Freezing Of Gait Device Attachment, Reagan Burns, Sidney Collin, Hadley Rose
Biomedical Engineering
The Freezing of Gait Project aims to design and develop an attachment mechanism for a medical device to help Parkinson’s patients overcome freezing of gait (FOG). The mechanism will allow the device to attach to a variety of canes or walkers, while being easy for Parkinson’s patients to use. It will interface with a device produced by De Oro Devices. The project includes an analysis of current competitive devices, a summary of customer needs, design of experiments to test significant features of the attachment, and project plan. The customer needs are translated to engineering metrics. Failures and mitigation of risks …
Heat Stress Identification,
2019
California Polytechnic State University, San Luis Obispo
Heat Stress Identification, Nathanial Nyberg, Christina Santini, Zachary Miller
Biomedical Engineering
This document contains all information pertinent to the creation of the desired product and how the desired product fulfills the problem statement. This document clearly defines the customer requirements and how they relate to engineering specifications, metrics that will define the boundaries that the desired product must lie within. This document will then reveal all concepts that were considered during the design phase of this project and how those concepts were compared. This includes all quantitative parameters that provided a clear front-runner concept and the rationale for those parameters and the values and weight assigned to them.
Then this document …
Flash-Mold Machine For Manufacturing Drug Implants,
2019
California Polytechnic State University, San Luis Obispo
Flash-Mold Machine For Manufacturing Drug Implants, Conor Vache, Sonja Daebelliehn, Ryan Thomson
Biomedical Engineering
This Final Project Report provides the reader with a comprehensive detailing of all of the actions and work that has been completed for this Senior Design Project. In this report, the Cal Poly Biomedical Engineering Senior Project Team will discuss some background on the existing Mark I Flash-Mold Machine currently in use by Gesea Biosciences, background information on Gesea Biosciences, the Customer Requirements and Design Specifications of the new machine, Quality Engineering considerations, design concepts discussed, design concepts chosen, safety considerations, prototype development, manufacturing, testing protocols, and testing results, etc.
A Pilot Study Identifying Brain-Targeting Adaptive Immunity In Pediatric Extracorporeal Membrane Oxygenation Patients With Acquired Brain Injury,
2019
UT Southwestern Medical Center
A Pilot Study Identifying Brain-Targeting Adaptive Immunity In Pediatric Extracorporeal Membrane Oxygenation Patients With Acquired Brain Injury, Sterling B. Ortega, Poornima Pandiyan, Jana Windsor, Vanessa O. Torres, Uma M. Selvaraj, Amy Lee, Michael Morriss, Fenghua Tian, Lakshmi Raman, Ann M. Stowe
Neurology Faculty Publications
OBJECTIVES: Extracorporeal membrane oxygenation provides short-term cardiopulmonary life support, but is associated with peripheral innate inflammation, disruptions in cerebral autoregulation, and acquired brain injury. We tested the hypothesis that extracorporeal membrane oxygenation also induces CNS-directed adaptive immune responses which may exacerbate extracorporeal membrane oxygenation-associated brain injury.
DESIGN: A single center prospective observational study.
SETTING: Pediatric and cardiac ICUs at a single tertiary care, academic center.
PATIENTS: Twenty pediatric extracorporeal membrane oxygenation patients (0-14 yr; 13 females, 7 males) and five nonextracorporeal membrane oxygenation Pediatric Logistic Organ Dysfunction score matched patients.
INTERVENTIONS: None.
MEASUREMENTS AND MAIN RESULTS: Venous blood samples were …
Plga Scaffold Device,
2019
California Polytechnic State University, San Luis Obispo
Plga Scaffold Device, Tyler D. Tackabery, Bryce Powada, Tate Morell
Biomedical Engineering
No abstract provided.
Esophageal Mapping And Temperature Regulation For Catheter Ablation,
2019
California Polytechnic State University, San Luis Obispo
Esophageal Mapping And Temperature Regulation For Catheter Ablation, Madison J. Keith, Morgan A. Jawitz, Sarah L. Sanders
Biomedical Engineering
The purpose of this document is to provide a development summary for a proposed esophageal temperature mapping device used during catheter ablation. Catheter ablation therapy is performed in the left atria with hot or cold materials to create scar tissue to treat atrial fibrillation. However, utilized temperatures and absorbed energies from the catheter can cause undesired esophageal damage. Therefore, this medical device is designed to monitor esophageal temperature and map its location during catheter ablation. If dangerous temperatures are reached, the device will alarm the surgeon.
This document provides an in-depth overview of the esophageal temperaturemapping device’s development and contains …
Concussion Indication Device,
2019
California Polytechnic State University, San Luis Obispo
Concussion Indication Device, Taylor O'Donoghue, Isabel Jellen, Eric Shechter
Biomedical Engineering
In this document we summarize our intent to design and manufacture a device that will be used in conjunction with a football helmet, will detect impact forces to the head, and notify the user to seek out further medical attention when subjected to forces large enough to cause concussions. We describe the large market including all levels of football players and the need for improved technology that will not only be effective in elucidating risks but encouraging players to use the device over the alternatives. To design the device, we have researched the problem of concussions in football and have …
Enhancement Of Viable Adipose-Derived Stem Cells In Lipoaspirate By Buffering Tumescent With Sodium Bicarbonate,
2019
University of Nevada, Las Vegas
Enhancement Of Viable Adipose-Derived Stem Cells In Lipoaspirate By Buffering Tumescent With Sodium Bicarbonate, Ashish Francis Md, Wei Z. Wang Md, Joshua J. Goldman Md, Xin-Hua Fang Mt, Shelley J. Williams Ms, Richard C. Baynosa Md; Facs
School of Medicine Faculty Research
Background: Fat grafting is a growing field within plastic surgery. Adipose-derived stem cells (ASCs) and stromal vascular fracture (SVF) may have a role in fat graft survival. Our group previously demonstrated a detrimental effect on ASC survival by the lidocaine used in tumescent solution. Sodium bicarbonate (SB) buffers the acidity of lidocaine. The purpose of this study was to determine whether SB buffering is a practical method to reduce ASC and SVF apoptosis and necrosis seen with common lidocaine-containing tumescent solution. Methods: Human patients undergoing bilateral liposuction for any indication were included in this study. An internally controlled, split-body design …
Accelerated Wear Reactor Testing,
2019
California Polytechnic State University, San Luis Obispo
Accelerated Wear Reactor Testing, Tristan Frisella, Daniel Alanis, Kian Ashoubi
Biomedical Engineering
Carbon dioxide accounts for a large amount of global greenhouse gases released into the environment. Because plastic degradation emits carbon dioxide, there has been interest to investigate how much carbon dioxide various plastics generate as they degrade. We have been tasked to create a dehumidifier and carbon dioxide sensor assembly for an accelerated wear testing apparatus that degrades plastic. Several products and literature currently exist that share similarity with our assembly but have not been manufactured to achieve the same combination of measurements we are expecting of our accelerated wear testing device. The following report shall introduce these products and …
Pressure Cylinder Controlled Release Valve,
2019
California Polytechnic State University, San Luis Obispo
Pressure Cylinder Controlled Release Valve, Alexa Dominique Balbuena
Biomedical Engineering
This project aims to integrate an automatic gas release system in a pre-existing scaffold fabrication process for tissue engineering applications.
To form the proper scaffold structure, the fabrication process is heavily influenced by the change in its surrounding pressure. The current production involves a pressure transducer and electric valve that is managed manually to create a suitable pressure environment for the scaffold. This method, although functional, proves to be ineffective when creating several batches; the user needs to constantly monitor the developing pressure profile and alter voltage parameters accordingly to create a linear gas release under a predetermined slope.
To …
Perturbation Based Decomposition Of Semg Signals,
2019
California Polytechnic State University, San Luis Obispo
Perturbation Based Decomposition Of Semg Signals, Rachel Huettinger
Master's Theses
Surface electromyography records the motor unit action potential signals in the vicinity of the electrode to reveal information on muscle activation. Decomposition of sEMG signals for characterization of constituent motor unit action potentials in terms of amplitude and firing times is useful for clinical research as well as diagnosis of neurological disorders. Successful decomposition of sEMG signals would allow for pertinent motor unit action potential information to be acquired without discomfort to the subject or the need for a well-trained operator (compared with intramuscular EMG). To determine amplitudes and firing times for motor unit action potentials in an sEMG recording, …
Development Of A Myoelectric Detection Circuit Platform For Computer Interface Applications,
2019
California Polytechnic State University, San Luis Obispo
Development Of A Myoelectric Detection Circuit Platform For Computer Interface Applications, Nickolas Andrew Butler
Master's Theses
Personal computers and portable electronics continue to rapidly advance and integrate into our lives as tools that facilitate efficient communication and interaction with the outside world. Now with a multitude of different devices available, personal computers are accessible to a wider audience than ever before. To continue to expand and reach new users, novel user interface technologies have been developed, such as touch input and gyroscopic motion, in which enhanced control fidelity can be achieved. For users with limited-to-no use of their hands, or for those who seek additional means to intuitively use and command a computer, novel sensory systems …
Fluid Delivery System For A Cell Culture On A Microfluidic Chip,
2019
California Polytechnic State University, San Luis Obispo
Fluid Delivery System For A Cell Culture On A Microfluidic Chip, Austin J. Roeder, Colleen A. Richards, Emily A. Matteson
Biomedical Engineering
This project report provides a description of the progress made in the development of a fluid delivery system for a microfluidic cell culture on a chip. The system is intended to be used in a humidified incubator in a university laboratory and the fluid delivery system is required to exist and operate within that incubator for extended periods of time. Therefore, the system will be gravity-driven and contain no electronic components. The key specification of the system is to provide fluid flow at a constant velocity.
After manufacturing and testing the device, all specifications were met except for the fluid …
Hands-Free Ultrasound Transducer Attachment,
2019
California Polytechnic State University, San Luis Obispo
Hands-Free Ultrasound Transducer Attachment, Christina Harrison, Glenn Farina, Harshveer Dhaliwal
Biomedical Engineering
This document describes a background on current ultrasound technologies and the troubles that have inspired the need for a hands-free ultrasound transducer device, as well as the regulatory requirements, like patents and standard codes, for the intended invention. It also explains the Stage Gate Review process used to project plan the design of the device, a description of the final design and how it was developed, and the IQ/OQ/PQ. The objectives necessary to design this device, in order to meet all the requirements of the sponsor, are also summarized here. The design process including manufacturing instructions, prototype evolution, and the …
Slit Lamp Ophthalmoscope Redesign,
2019
California Polytechnic State University, San Luis Obispo
Slit Lamp Ophthalmoscope Redesign, Michael Hostetler, Austin Mattmiller, Alexis Brewer
Biomedical Engineering
The slit lamp ophthalmoscope is used by ophthalmologists for diagnosis of pathologies in the eye. The device is used for identifying ocular diseases or indications of other possible systemic diseases to treat them before the diseases progress. Redesign of the ergonomics and adjustment mechanisms of the slit lamp ophthalmoscope will attempt to improve the compatibility of the device across a greater variety of patients. The wider headrest tower of 12.75 inches, the wider table cutout of 12 inches, and the 12 inches of extension of the headrest tower creates a better ergonomic fit for the patient and doctor. The wider …
Foot Support Taping Device For Off-Loading Wounds,
2019
California Polytechnic State University, San Luis Obispo
Foot Support Taping Device For Off-Loading Wounds, Andres Fojaco Gomez, Mikaela Williams, Josh Pelegrin
Biomedical Engineering
No abstract provided.
Ideomotion Gait Training Thigh Prompt,
2019
California Polytechnic State University, San Luis Obispo
Ideomotion Gait Training Thigh Prompt, Kristin Schmidt, Elizabeth Peterson, Dalton Jennings
Biomedical Engineering
This document serves as our project report at its completion for developing thigh prompts to be used with the LiftWalker. In this document we outline our project from its beginning to end. We describe our process from understanding the background and our customer requirements, transforming these customer requirements into engineering specifications, performing the stage gate process, developing and evolving the design, testing the design, and finally drawing conclusions and making recommendations for the future.
Automated Microscope Stage,
2019
California Polytechnic State University, San Luis Obispo
Automated Microscope Stage, Corin Nishimoto, Alison Flesch, Theo Anastos
Biomedical Engineering
This document seeks to describe the background information, customer requirements, design specifications, indications for use, selected materials, proposed budget, prototypes, final design, manufacturing processes, and testing methods regarding the CellOptimizer automated microscope stage product.
Advanced Selection Methodologies For Dnazymes In Sensing And Healthcare Applications,
2019
Guru Jambheshwar University of Science and Technology
Advanced Selection Methodologies For Dnazymes In Sensing And Healthcare Applications, Sandeep Kumar, Shikha Jain, Neeraj Dilbaghi, Amrik Singh Ahluwalia, Ashraf Aly Hassan, Ki-Hyun Kim
Department of Civil and Environmental Engineering: Faculty Publications
DNAzymes have been widely explored owing to their excellent catalytic activity in a broad range of applications, notably in sensing and biomedical devices. These newly discovered applications have built high hopes for designing novel catalytic DNAzymes. However, the selection of efficient DNAzymes is a challenging process but one that is of crucial importance. Initially, systemic evolution of ligands by exponential enrichment (SELEX) was a labor-intensive and time-consuming process, but recent advances have accelerated the automated generation of DNAzyme molecules. This review summarizes recent advances in SELEX that improve the affinity and specificity of DNAzymes. The thriving generation of new DNAzymes …
Bio-Inspired Sensing And Actuating Architectures For Feedback Control Of Civil Structures,
2019
Hope College
Bio-Inspired Sensing And Actuating Architectures For Feedback Control Of Civil Structures, Courtney A. Peckens, I. Cook, C. Fogg
Faculty Publications
Civil structures, such as buildings and bridges, are constantly at risk of failure due to external environmental loads, such as earthquakes or strong winds. To minimize the effects of these loads, active feedback control systems have been proposed but such systems still face numerous challenges which impede their widespread adoption. In order to overcome many of these challenges, inspiration can be drawn from the signal processing and actuating techniques employed by the biological central nervous system to develop a bio-inspired control algorithm. In this study the front-end, signal processing techniques employed by biological sensory systems, and in particular the mammalian …