Nebraska Summary: S502 Kubota M9000dt, Nebraska Tractor Test Lab Jan 1998

Nebraska Summary: S502 Kubota M9000dt, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data. EXPLANATION OF THE TEST PROCEDURES Purpose The purpose of …


Test 1899: Case Ih Cx 100/Case Ih C100/Mccormick C 100 & Cx 100 & Cx 105 Diesel, Nebraska Tractor Test Lab Jan 1998

Test 1899: Case Ih Cx 100/Case Ih C100/Mccormick C 100 & Cx 100 & Cx 105 Diesel, Nebraska Tractor Test Lab

Nebraska Tractor Tests

No abstract provided.


Test 1815: New Holland 9482 Quadrasync Diesel, Nebraska Tractor Test Lab Jan 1998

Test 1815: New Holland 9482 Quadrasync Diesel, Nebraska Tractor Test Lab

Nebraska Tractor Tests

No abstract provided.


Test 1779: Challenger Mt 425 Diesel, Nebraska Tractor Test Lab Jan 1998

Test 1779: Challenger Mt 425 Diesel, Nebraska Tractor Test Lab

Nebraska Tractor Tests

No abstract provided.


Nebraska Summary 276: Massey Ferguson 4325 And 4225 Diesel 12-Speed, Nebraska Tractor Test Lab Jan 1998

Nebraska Summary 276: Massey Ferguson 4325 And 4225 Diesel 12-Speed, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA

The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data.

EXPLANATION OF THE TEST PROCEDURES

Purpose

The purpose of …


Nebraska Summary 277: Massey-Ferguson 4235 Diesel 18-Speed, Nebraska Tractor Test Lab Jan 1998

Nebraska Summary 277: Massey-Ferguson 4235 Diesel 18-Speed, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA

The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data.

EXPLANATION OF THE TEST PROCEDURES

Purpose

The purpose of …


Nebraska Summary 289: John Deere 6310 Powrquad Diesel 16-Speed, Nebraska Tractor Test Lab Jan 1998

Nebraska Summary 289: John Deere 6310 Powrquad Diesel 16-Speed, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA

The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data.

EXPLANATION OF THE TEST PROCEDURES

Purpose

The purpose of …


Nebraska Summary 300: Massey Ferguson 6245 Diesel 32-Speed, Nebraska Tractor Test Lab Jan 1998

Nebraska Summary 300: Massey Ferguson 6245 Diesel 32-Speed, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA

The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data.

EXPLANATION OF THE TEST PROCEDURES

Purpose

The purpose of …


Test 1899: Case Ih Cx 100/C 100 Diesel, Nebraska Tractor Test Lab Jan 1998

Test 1899: Case Ih Cx 100/C 100 Diesel, Nebraska Tractor Test Lab

Nebraska Tractor Tests

No abstract provided.


Test 1745: John Deere 8200t Dieel 16-Speed, Nebraska Tractor Test Lab Jan 1998

Test 1745: John Deere 8200t Dieel 16-Speed, Nebraska Tractor Test Lab

Nebraska Tractor Tests

EXPLANATION OF THE TEST PROCEDURE General Tractors are tested at the University of Nebraska according to the Agricultural Tractor Test Code approved by the American Society of Agricultural Engineers and the Society of Automotive Engineers or official Nebraska test procedure. The manufacturer selects the tractor to be tested and certifies that it is a stock model. Each tractor is equipped with the common power consuming accessories such as power steering, power lift pump, generator, etc., if available. Power consuming accessories may be disconnected only when the means for disconnecting can be reached from the operating station. An official representative of …


Test 1746: John Deere 8300t Diesel 16-Speed, Nebraska Tractor Test Lab Jan 1998

Test 1746: John Deere 8300t Diesel 16-Speed, Nebraska Tractor Test Lab

Nebraska Tractor Tests

EXPLANATION OF THE TEST PROCEDURE

General

Tractors are tested at the University of Nebraska according to the Agricultural Tractor Test Code approved by the American Society of Agricultural Engineers and the Society of Automotive Engineers or official Nebraska test procedure.

The manufacturer selects the tractor to be tested and certifies that it is a stock model. Each tractor is equipped with the common power consuming accessories such as power steering, power lift pump, generator, etc., if available. Power consuming accessories may be disconnected only when the means for disconnecting can be reached from the operating station. An official representative of …


Test 1749: Caterpiller Challenger 75e Diesel 10-Speed`, Nebraska Tractor Test Lab Jan 1998

Test 1749: Caterpiller Challenger 75e Diesel 10-Speed`, Nebraska Tractor Test Lab

Nebraska Tractor Tests

EXPLANATION OF THE TEST PROCEDURE

General

Tractors are tested at the University of Nebraska according to the Agricultural Tractor Test Code approved by the American Society of Agricultural Engineers and the Society of Automotive Engineers or official Nebraska test procedure.

The manufacturer selects the tractor to be tested and certifies that it is a stock model. Each tractor is equipped with the common power consuming accessories such as power steering, power lift pump, generator, etc., if available. Power consuming accessories may be disconnected only when the means for disconnecting can be reached from the operating station. An official representative of …


Test 1750: Caterpiller Challenger 85e Diesel 10-Speed, Nebraska Tractor Test Lab Jan 1998

Test 1750: Caterpiller Challenger 85e Diesel 10-Speed, Nebraska Tractor Test Lab

Nebraska Tractor Tests

EXPLANATION OF THE TEST PROCEDURE

General

Tractors are tested at the University of Nebraska according to the Agricultural Tractor Test Code approved by the American Society of Agricultural Engineers and the Society of Automotive Engineers or official Nebraska test procedure.

The manufacturer selects the tractor to be tested and certifies that it is a stock model. Each tractor is equipped with the common power consuming accessories such as power steering, power lift pump, generator, etc., if available. Power consuming accessories may be disconnected only when the means for disconnecting can be reached from the operating station. An official representative of …


Test 1753: White 8410 Diesel 18-Speed, Nebraska Tractor Test Lab Jan 1998

Test 1753: White 8410 Diesel 18-Speed, Nebraska Tractor Test Lab

Nebraska Tractor Tests

EXPLANATION OF THE TEST PROCEDURE

General

Tractors are tested at the University of Nebraska according to the Agricultural Tractor Test Code approved by the American Society of Agricultural Engineers and the Society of Automotive Engineers or official Nebraska test procedure.

The manufacturer selects the tractor to be tested and certifies that it is a stock model. Each tractor is equipped with the common power consuming accessories such as power steering, power lift pump, generator, etc., if available. Power consuming accessories may be disconnected only when the means for disconnecting can be reached from the operating station. An official representative of …


Test 1757: John Deere 5510 Diesel 9-Speed, Nebraska Tractor Test Lab Jan 1998

Test 1757: John Deere 5510 Diesel 9-Speed, Nebraska Tractor Test Lab

Nebraska Tractor Tests

EXPLANATION OF THE TEST PROCEDURE General Tractors are tested at the University of Nebraska according to the Agricultural Tractor Test Code approved by the American Society of Agricultural Engineers and the Society of Automotive Engineers or official Nebraska test procedure. The manufacturer selects the tractor to be tested and certifies that it is a stock model. Each tractor is equipped with the common power consuming accessories such as power steering, power lift pump, generator, etc., if available. Power consuming accessories may be disconnected only when the means for disconnecting can be reached from the operating station. An official representative of …


Test 1803: Kubota M6800dt Diesel, Nebraska Tractor Test Lab Jan 1998

Test 1803: Kubota M6800dt Diesel, Nebraska Tractor Test Lab

Nebraska Tractor Tests

No abstract provided.


Test 1744: John Deere 8100t Diesel 16-Speed, Nebraska Tractor Test Lab Jan 1998

Test 1744: John Deere 8100t Diesel 16-Speed, Nebraska Tractor Test Lab

Nebraska Tractor Tests

EXPLANATION OF THE TEST PROCEDURE General Tractors are tested at the University of Nebraska according to the Agricultural Tractor Test Code approved by the American Society of Agricultural Engineers and the Society of Automotive Engineers or official Nebraska test procedure. The manufacturer selects the tractor to be tested and certifies that it is a stock model. Each tractor is equipped with the common power consuming accessories such as power steering, power lift pump, generator, etc., if available. Power consuming accessories may be disconnected only when the means for disconnecting can be reached from the operating station. An official representative of …


A Portable Photovoltaic Water Aeration System, Florida Solar Energy Center, William Young Dec 1997

A Portable Photovoltaic Water Aeration System, Florida Solar Energy Center, William Young

FSEC Energy Research Center®

Water aeration is a method to improve the water quality in a lake by adding oxygen to the water. Because water aeration systems are often located in remote locations, photovoltaics are ideal for powering these systems. This paper describes a water aeration system powered by photovoltaics that is used in Florida. The portable nature of this system permits the owner to conveniently relocate the system and aerate bodies of water as needed.


Measured Energy Savings Of A Comprehensive Retrofit In An Existing Florida Residence, Florida Solar Energy Center, Charles Withers, Jr. Dec 1997

Measured Energy Savings Of A Comprehensive Retrofit In An Existing Florida Residence, Florida Solar Energy Center, Charles Withers, Jr.

FSEC Energy Research Center®

Simulation analysis suggests that electricity consumption can be reduced up to 40% in existing Florida homes with judicious use of methods to reduce loads, as well as more efficient equipment. To test this theory, an all-electric home was located in Miami, Florida upon which to perform a variety of retrofits. The total annual electricity consumption in the one year base-line period preceding the study was 20,733 kWh. Although high, this is not unusual for a South Florida home with a swimming pool since pool pumping often accounts 3,000 -4,000 kWh per year. Detailed instrumentation and metering equipment was installed in …


Energy Needs During Disasters: Workshop Summary Report, Florida Solar Energy Center, Gerard Ventre Nov 1997

Energy Needs During Disasters: Workshop Summary Report, Florida Solar Energy Center, Gerard Ventre

FSEC Energy Research Center®

When natural disasters, such as hurricanes, earthquakes and floods, occur, thousands of people can be left without homes, electrical power, communications, potable water, and food storage capabilities. Adequate electrical power is imperative for both disaster relief operations and community rebuilding. However, the disaster may have disrupted the commercial power supply to a community, requiring disaster relief agencies to rely on alternative sources of power. Photovoltaic-powered equipment provides electrical power which is renewable, quiet, and safe, and which can be used for many essentials of disaster relief efforts, such as refrigeration, communications and lighting. However, at present, photovoltaic (PV) technology is …


Pv Powering A Weather Station For Severe Weather, Florida Solar Energy Center, William Young Nov 1997

Pv Powering A Weather Station For Severe Weather, Florida Solar Energy Center, William Young

FSEC Energy Research Center®

A natural disaster, such as Hurricane Andrew, destroys thousands of homes and businesses. The destruction from this storm left thousands of people without communications, potable water, and electric power. This prompted the Florida Solar Energy Center to study the application of solar electric power for use in disasters.

During this same period, volunteers at the Tropical Prediction Center at the National Hurricane Center (NHC) and the Miami Office of the National Weather Service (NWS) were working to increase the quantity and quality of observations received from home weather stations.

Many weather data collecting stations are at remote sites, which are …


Maine Guide To Energy Efficient Residential Construction : A Manual Of Accepted Practices, State Of Maine Energy Conservation Division Nov 1997

Maine Guide To Energy Efficient Residential Construction : A Manual Of Accepted Practices, State Of Maine Energy Conservation Division

Maine Collection

Maine Guide to Energy Efficient Residential Construction : A Manual of Accepted Practices

State of Maine Energy Conservation Division, Department of Economic and Community Development, 59 State House Station, Augusta, Maine 04333-0059

Second Edition - November, 1997

Contents: Dedication / Acknowledgements / Introduction / Part 1. Summary of Maine's Residential Energy Standards / Part 2. Siting and Initial Design Considerations / Part 3. Important Considerations for the Design Phase / Part 4. Recommended Construction Practices / Appendixes


Demonstration Of Cooling Savings Of Light Colored Roof Surfacing In Florida Commercial Buildings: Retail Strip Mall, Florida Solar Energy Center, Danny Parker Oct 1997

Demonstration Of Cooling Savings Of Light Colored Roof Surfacing In Florida Commercial Buildings: Retail Strip Mall, Florida Solar Energy Center, Danny Parker

FSEC Energy Research Center®

A series of tests were conducted in seven retail shops in a strip mall in Cocoa, Florida to examine how roof whitening would impact air conditioning load. The roof of the strip mall was conventional: unsurfaced galvanized corrugated metal with R-11 insulation suspended by purlins underneath. Below the insulation was the roof plenum which contained both the air handler and duct air distribution system. Cooling was accomplished in each shop by a dedicated direct expansion air conditioning (AC) system between 3 and 4 tons in size. Each had its air conditioning metered for half of the summer in a baseline …


Photovoltaic Equipment For Disaster Relief, Florida Solar Energy Center, William Young Sep 1997

Photovoltaic Equipment For Disaster Relief, Florida Solar Energy Center, William Young

FSEC Energy Research Center®

Photovoltaic (solar electricity) has been used to power various equipment used in disasters. Previously, no organized program had used photovoltaic powered equipment in disasters. In response to an energy needs study with disaster relief organizations, Sandia National Laboratories for the U.S. Department of Energy sponsored the Florida Solar Energy Center to provide PV equipment to selected disaster relief organizations and evaluate its performance and acceptability. The purpose of the report is to describe the six PV-powered systems that were provided.


Controlling Ventilation And Space Depressurization In Restaurants In Hot And Humid Climates, Florida Solar Energy Center, Charles Withers, Jr. Sep 1997

Controlling Ventilation And Space Depressurization In Restaurants In Hot And Humid Climates, Florida Solar Energy Center, Charles Withers, Jr.

FSEC Energy Research Center®

Testing was performed in 9 restaurants to identify uncontrolled air flows and pressure imbalances, building and duct system airtightness, building air barrier location, pressure differentials, building air flow balance, and ventilation rates. All restaurants are depressurized under normal operating conditions, ranging from -1.0 to -43 pascals. Space depressurization is a function of exhaust fan flow rates, missing or undersized make-up air, intermittent outdoor air caused by the cycling of air handlers, dirty outdoor air and make-up air filters, and building airtightness. Ventilation rates were found to be high, generally exceeding ASHRAE 62-1989 minimum recommended levels. Pressure imbalances and excessive ventilation …


Moving Mountains With Good Research - A Case Study, Florida Solar Energy Center, Ross Mccluney Jul 1997

Moving Mountains With Good Research - A Case Study, Florida Solar Energy Center, Ross Mccluney

FSEC Energy Research Center®

Mountains can be moved by good ideas based on good research. A wonderful example comes to us from, of all things, the Naval Facilities Command (NAVFAC), headquartered in Washington, DC. This agency of the Department of Defense is responsible for some $5 billion per year in new and retrofit construction, with naval facilities all over the globe. The federal government alone is responsible for $50 billion per year of construction, which Terry Emmons of NAVFAC claims is half of total U.S. construction. It seems that the Navy has 120,000 buildings around the world, some buildings, or groupings, are the size …


Batteries And Charge Control In Stand-Alone Photovoltaic Systems, Florida Solar Energy Center, James Dunlop Jul 1997

Batteries And Charge Control In Stand-Alone Photovoltaic Systems, Florida Solar Energy Center, James Dunlop

FSEC Energy Research Center®

This report presents fundamentals of battery technology and charge control strategies commonly used in stand-alone photovoltaic (PV) systems. This work is a compilation of information from several sources, including PV system design manuals, research reports and data from component manufacturers.

Details are provided about the common types of flooded lead-acid, valve regulated lead-acid, and nickel cadmium cells used in PV systems, including their design and construction, electrochemistry and operational performance characteristics. Comparisons are given for various battery technologies, and considerations for battery subsystem design, auxiliary systems, maintenance and safety are discussed.

Requirements for battery charge control in stand-alone PV systems …


Needs Assessment For Applying Photovoltaics To Disaster Relief, Florida Solar Energy Center, William Young Jul 1997

Needs Assessment For Applying Photovoltaics To Disaster Relief, Florida Solar Energy Center, William Young

FSEC Energy Research Center®

When disaster strikes, such as a hurricane, flood, tornado, or earthquake, it can leave many people without adequate medical services, portable water, electrical service and communications. It can be as destructive as Hurricane Andrew, which left several hundred-thousand people homeless. Those fortunate enough to survive the disaster could be without local utility power and other services for long periods of time as services are restored.

When such disasters occur, emergency management teams, the military, and many public and private organizations respond with massive relief efforts. Dependency on electrical utility power becomes pronounced as emergency services are rendered and rebuilding begins. …


Energy Efficiency For Florida Educational Facilities: The 1996 Energy Survey Of Florida Schools, Florida Solar Energy Center, Danny Parker Jul 1997

Energy Efficiency For Florida Educational Facilities: The 1996 Energy Survey Of Florida Schools, Florida Solar Energy Center, Danny Parker

FSEC Energy Research Center®

A detailed survey of energy use and related physical and operational characteristics of Florida's public schools has been completed. A mailed survey instrument was sent to all 2,512 schools throughout the state in March 1996. A total of 1, 298 surveys were returned -- a response rate of approximately 52%. Of these some 680 provided matching utility data. The survey data was analyzed to create a school energy use profile as well as to identify characteristics that may influence efficiency. Based on our findings, the total annual energy cost for the Florida school system totaled $205 million in 1995. As …


The Effect Of Residential Equipment Capacity On Energy Use, Demand, And Run-Time, Florida Solar Energy Center, Jo Ellen Cummings Jul 1997

The Effect Of Residential Equipment Capacity On Energy Use, Demand, And Run-Time, Florida Solar Energy Center, Jo Ellen Cummings

FSEC Energy Research Center®

Installed central air conditioning system capacities in 368 recently-built Florida homes were compared with Manual J load values calculated from house audit data. Over 50% of the homes had installed systems with a cooling capacity greater than 120% of the calculated Manual J value. Thirty-one percent of the 78 heat pump homes in this study had installed heating capacity greater than 120% of the calculated Manual J value. Using submetered data from the air conditioning system, a definite increase in peak energy use was observed for systems sized over 120% of Manual J calculations. The effect of system sizing on …