Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Physical Sciences and Mathematics (4165)
- Other Mechanical Engineering (3478)
- Education (3409)
- Science and Mathematics Education (3401)
- Arts and Humanities (3400)
-
- History (3397)
- History of Science, Technology, and Medicine (3397)
- United States History (3397)
- Environmental Sciences (678)
- Materials Science and Engineering (649)
- Sustainability (632)
- Oil, Gas, and Energy (630)
- Structural Materials (591)
- Environmental Monitoring (582)
- Environmental Indicators and Impact Assessment (581)
- Mining Engineering (579)
- Electrical and Computer Engineering (222)
- Heat Transfer, Combustion (217)
- Power and Energy (188)
- Electro-Mechanical Systems (127)
- Chemical Engineering (115)
- Civil and Environmental Engineering (107)
- Operations Research, Systems Engineering and Industrial Engineering (83)
- Applied Mechanics (74)
- Electrical and Electronics (67)
- Computer-Aided Engineering and Design (60)
- Social and Behavioral Sciences (54)
- Institution
-
- University of Nebraska - Lincoln (3406)
- University of Kentucky (601)
- University of Central Florida (531)
- California Polytechnic State University, San Luis Obispo (95)
- University of Dar es Salaam (88)
-
- Technological University Dublin (73)
- Michigan Technological University (60)
- University of Arkansas, Fayetteville (43)
- West Virginia University (39)
- Georgia Southern University (35)
- The British University in Egypt (34)
- Purdue University (33)
- Embry-Riddle Aeronautical University (27)
- University of Nevada, Las Vegas (25)
- University of South Carolina (21)
- World Maritime University (21)
- Association of Arab Universities (19)
- Calvin University (19)
- Vocational Training Council (19)
- Old Dominion University (18)
- Portland State University (18)
- City University of New York (CUNY) (17)
- The University of Akron (14)
- University of Dayton (14)
- Louisiana State University (13)
- University of Louisville (13)
- Western Michigan University (13)
- University of Southern Maine (11)
- Central Washington University (10)
- Department of Primary Industries and Regional Development, Western Australia (10)
- Keyword
-
- Buildings (280)
- Gas (249)
- And Energy; Structural Materials; Sustainability (248)
- Energy Systems; Environmental Indicators and Impact Assessment; Environmental Monitoring; Mining Engineering; Oil (248)
- Energy Efficiency (97)
-
- Energy efficiency (77)
- HVAC (67)
- Energy (55)
- Solar energy (46)
- Cooling (44)
- Photovoltaics (42)
- Energy savings (39)
- Ventilation (35)
- Energy Consumption (34)
- Renewable energy (34)
- Electric Vehicles (33)
- Simulation (32)
- 1957 (29)
- Air Flow (29)
- Ducts (29)
- Energy Conservation (29)
- Solar (29)
- Residential (28)
- Energy conservation (24)
- Roofs (24)
- Energy consumption (23)
- Disaster Relief (22)
- Solar Energy (21)
- Solar Thermal (21)
- Engineering (20)
- Publication Year
- Publication
-
- Nebraska Tractor Tests (3397)
- World of Coal Ash Proceedings (578)
- FSEC Energy Research Center® (511)
- Tanzania Journal of Engineering and Technology (TJET) (86)
- Mechanical Engineering (80)
-
- Dissertations, Master's Theses and Master's Reports (55)
- Graduate Theses, Dissertations, and Problem Reports (ETD) (39)
- Articles (36)
- Master's Theses (30)
- Electronic Theses and Dissertations (26)
- Faculty Publications (25)
- Theses and Dissertations (20)
- Dissertations and Theses (19)
- Faculty of Science & Technology (THEi) (19)
- World Maritime University Dissertations (19)
- College of Graduate Studies: Theses & Dissertations (18)
- Conference Papers (18)
- Graduate Theses and Dissertations (18)
- The Summer Undergraduate Research Fellowship (SURF) Symposium (16)
- Journal of Engineering Research (15)
- Mechanical Engineering Undergraduate Honors Theses (14)
- Williams Honors College, Honors Research Projects (14)
- Doctoral Dissertations and Master's Theses (13)
- ENgaging Educators in Renewable enerGY (ENERGY): Lesson Plans & Slideshows (2017-2019) (13)
- Mechanical and Aerospace Engineering Faculty Publications (12)
- Theses and Dissertations--Mechanical and Aerospace Engineering (12)
- ENGR 333 (11)
- Honors Theses (11)
- Maine Collection (11)
- Journal of the Department of Agriculture, Western Australia, Series 4 (10)
- Publication Type
- File Type
Articles 3151 - 3180 of 5621
Full-Text Articles in Energy Systems
Test 2088: Case Ih Mxm130 Diesel, Nebraska Tractor Test Lab
Test 2088: Case Ih Mxm130 Diesel, Nebraska Tractor Test Lab
Nebraska Tractor Tests
No abstract provided.
Nebraska Summary: S438 New Holland Tm190, Nebraska Tractor Test Lab
Nebraska Summary: S438 New Holland Tm190, Nebraska Tractor Test Lab
Nebraska Tractor Tests
ABOUT THE TEST REPORT AND USE OF THE DATA The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data. EXPLANATION OF THE TEST PROCEDURES Purpose The purpose of …
Test 1821: Challenger Mt735 Diesel, Nebraska Tractor Test Lab
Test 1821: Challenger Mt735 Diesel, Nebraska Tractor Test Lab
Nebraska Tractor Tests
No abstract provided.
Test 1819: John Deere 8120 16-Speed, Nebraska Tractor Test Lab
Test 1819: John Deere 8120 16-Speed, Nebraska Tractor Test Lab
Nebraska Tractor Tests
ABOUT THE TEST REPORT AND USE OF THE DATA
The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data.
EXPLANATION OF THE TEST PROCEDURES
Purpose
The purpose of …
Tests 2077 & 2095: Case Ih Jx 80u Diesel, Nebraska Tractor Test Lab
Tests 2077 & 2095: Case Ih Jx 80u Diesel, Nebraska Tractor Test Lab
Nebraska Tractor Tests
No abstract provided.
Solar Dhw Collector Thermal Performance Ratings, Florida Solar Energy Center, John Harrison
Solar Dhw Collector Thermal Performance Ratings, Florida Solar Energy Center, John Harrison
FSEC Energy Research Center®
Thermal performance ratings, derived from the FSEC testing and certification program, are a useful tool in comparing the efficiency and economics of various flat-plate solar collectors. Since collectors used in domestic hot water (DHW) systems typically operate in the intermediate temperature range (1200F-1600F), this is the rating provided for comparisons. It must be stressed that these comparisons are only a guide and should not be considered as a rank ordering of collectors. Such considerations as component sizing and proper installation procedures are equally important in determining a system's overall efficiency. In addition, because of the variability of weather conditions, instrumentation …
Flexible Roofing Facility: 2001 Summer Test Results, Florida Solar Energy Center, Jeffrey Sonne
Flexible Roofing Facility: 2001 Summer Test Results, Florida Solar Energy Center, Jeffrey Sonne
FSEC Energy Research Center®
The Flexible Roof Facility (FRF) is a test facility in Cocoa, Florida designed to evaluate five roofing systems at a time against a control roof with dark shingles. The intent of the testing is to evaluate how roofing systems impact summer residential cooling energy use and peak demand. In the summer of 2001, the following roofing systems were tested.
Cell # Description
- Weathered white barrel tile with sealed attic
- Double roof with radiant barrier, sealed attic and insulated roof deck
- High reflectance brown metal shingle with vented attic
- Terra cotta barrel tile with vented attic
- Dark shingles with standard attic …
Energy And Environmental Integration Through A Green Municipality Designation, Florida Solar Energy Center, Eric Martin
Energy And Environmental Integration Through A Green Municipality Designation, Florida Solar Energy Center, Eric Martin
FSEC Energy Research Center®
Most local green building programs in existence seek to bestow a "green designation" on a builder, building owner, or developer with residential, commercial, and development standards. Municipalities, however, play an important role in making green building become "business as usual" rather than a conscious choice made by few. Municipalities can set an example to the community by incorporating green building techniques in the construction and operation of public and government buildings, play a vital role in community education, and can create incentives and mandates to foster green building within the community. Florida's green building program has set out to create …
Field Testing And Computer Modeling To Characterize The Energy Impacts Of Air Handler Leakage, Florida Solar Energy Center, James Cummings
Field Testing And Computer Modeling To Characterize The Energy Impacts Of Air Handler Leakage, Florida Solar Energy Center, James Cummings
FSEC Energy Research Center®
In order to determine the impact of air handler location upon heating and cooling energy use, the amount of air leakage which occurs in the air handler cabinet needs to be known. Also, the leakage which occurs at the connections between the air handler cabinet and the return and supply plenums needs to be known as well because these connection leaks would also be located in the attic or any other location.
In order to assess this leakage, testing was performed on a total of 69 air conditioning systems. Thirty systems were tested in the year 2001 under funding from …
Measured And Simulated Cooling Performance Comparison; Insulated Concrete Form Versus Frame Construction, Florida Solar Energy Center, Dave Chasar
Measured And Simulated Cooling Performance Comparison; Insulated Concrete Form Versus Frame Construction, Florida Solar Energy Center, Dave Chasar
FSEC Energy Research Center®
Four occupied homes near Dallas, Texas were monitored to compare cooling energy use. Two homes were built with typical wood frame construction, the other two with insulated concrete form (ICF) construction. Remote data loggers collected hourly readings of indoor and outdoor temperature, relative humidity, furnace runtime fraction, total building electrical energy and HVAC energy use. Data was recorded from January through August 2000.
Analysis of the measured data shows that insulated concrete form (ICF) construction can reduce seasonal cooling energy use 17 - 19% over frame construction in two-story homes in the North Texas climate. This result includes adjustments to …
Comparative Evaluation Of The Impact Of Roofing Systems On Residential Cooling Energy Demand In Florida, Florida Solar Energy Center, John Sherwin
Comparative Evaluation Of The Impact Of Roofing Systems On Residential Cooling Energy Demand In Florida, Florida Solar Energy Center, John Sherwin
FSEC Energy Research Center®
Roof and attic thermal performance exert a powerful influence on cooling energy use in Florida homes. The Florida Power and Light Company and the Florida Solar Energy Center instrumented six side-by-side Habitat homes in Ft. Myers, Florida with identical floor plans and orientation, R-19 ceiling insulation, but with different roofing systems designed to reduce attic heat gain. A seventh house had an unvented attic with insulation on the underside of the roof deck rather than the ceiling: (RGS) Standard dark shingles (control home); (RWB) White "Barrel" S-tile roof; (RWS) Light colored shingles; (RWF) White flat tile roof; (RTB) Terra cotta …
Design And Construction Of Interior Duct Systems, Florida Solar Energy Center, Janet Mcilvaine
Design And Construction Of Interior Duct Systems, Florida Solar Energy Center, Janet Mcilvaine
FSEC Energy Research Center®
To combat the energy, durability, and indoor air quality penalties of duct leakage, energy experts have recommended putting the duct system and air handler inside the conditioned space. Two paths of accomplishing this have emerged: unvented attics/crawl spaces and interior chases. This study focuses on the design, construction, and performance of the interior chase approach as implemented by five different builders in Texas, North Carolina, and Florida.
Researchers found that, in many cases, breeches of the air barrier were evident from simple visual inspection. Critical points of design and construction were identified and will be presented through photos, design and …
Solar Oven Development And Testing Contract Final Report, Florida Solar Energy Center, Philip W. Fairey
Solar Oven Development And Testing Contract Final Report, Florida Solar Energy Center, Philip W. Fairey
FSEC Energy Research Center®
The Florida Solar Energy Center (FSEC) was contracted by the Dorothy Ann Foundation (and its agent and representative, Darwin O. Curtis), to conduct an investigative study into the development of a state-of-the art solar cooker. A major goal of the contract was to investigate the potential means of improving the performance and long-term durability of the existing Cookit solar cooker.
Many of the activities and accomplishments conducted as part of this contract have been provided in the reports and analyses previously sent to the contact representative. The purpose of this final report is to list the various task accomplishments defined …
Solar Thermal Billing Program In Florida, Florida Solar Energy Center, Carlos Colon
Solar Thermal Billing Program In Florida, Florida Solar Energy Center, Carlos Colon
FSEC Energy Research Center®
This paper presents the development, implementation, and results of Lakeland Electric's solar thermal billing program in Florida. The three-phase solar program was started in 1997 with funds from the Florida Energy Office (FEO) and the technical assistance of the Florida Solar Energy Center (FSEC). It was designed as a model to expand the concept of distributed energy generation, and to augment the use of solar domestic hot water (SDHW) systems. The solar thermal billing program relies on the proceeds generated from the sale of hot water energy. Twenty-nine SDHW systems, which are owned by Lakeland Electric (LE), gradually began operation …
Performance And Impact From Duct Repair And Ventilation Modifications Of Two Newly Constructed Manufactured Houses Located In A Hot And Humid Climate, Florida Solar Energy Center, Charles Withers, Jr.
Performance And Impact From Duct Repair And Ventilation Modifications Of Two Newly Constructed Manufactured Houses Located In A Hot And Humid Climate, Florida Solar Energy Center, Charles Withers, Jr.
FSEC Energy Research Center®
Two nearly identical houses situated next to each other in Bossier City, Louisiana were studied in an effort to better understand moisture and cooling energy related problems in manufactured houses with low thermostat set-points during the cooling season. By design, the major difference between houses was the type of air conditioning units. House A had a standard split air conditioner and House B had a two-speed split air conditioner.
In an effort to make the buildings more similar, the building airtightness was adjusted until it was the same in each house, and duct leaks were sealed so that the ducts …
Suggested Methodologies For Determining The Shgc Of Complex Fenestration Systems For Nfrc Ratings, Florida Solar Energy Center, Ross Mccluney
Suggested Methodologies For Determining The Shgc Of Complex Fenestration Systems For Nfrc Ratings, Florida Solar Energy Center, Ross Mccluney
FSEC Energy Research Center®
Simple fenestration systems, for the purpose of this paper, are those whose solar heat gain and visible transmittance performances can be accurately simulated using the Window 4 or 5 programs developed at Lawrence Berkeley National Laboratory (LBNL). Complex fenestrations are everything else, including obscure or "privacy" glazing, corrugated or otherwise complex patterned glazing, curved, bent, or domed glazing, fritted glazing, glass blocks, glass fiber reinforced plastic daylighting panels, and glazings with internal or attached shading systems of a variety of types. The latter include exterior awnings and overhangs, attached exterior shade screens and shutters (including roll-up shutters), between-the-panes shades, including …
Test 1798: John Deere 8320 Diesel 16-Speed, Nebraska Tractor Test Lab
Test 1798: John Deere 8320 Diesel 16-Speed, Nebraska Tractor Test Lab
Nebraska Tractor Tests
ABOUT THE TEST REPORT AND USE OF THE DATA
The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data.
EXPLANATION OF THE TEST PROCEDURES
Purpose
The purpose of …
Research Highlightsfrom A Large Scale Residential Monitoring Study In A Hot Climate, Florida Solar Energy Center, Danny Parker
Research Highlightsfrom A Large Scale Residential Monitoring Study In A Hot Climate, Florida Solar Energy Center, Danny Parker
FSEC Energy Research Center®
This load research project by a large utility has monitored 204 residences in Central Florida, collecting detailed electricity end-use load data. In each home, 15-minute electric demand data is obtained on total electric power, space heating, cooling, water heating, dryers, cooking and pool energy use. Interior and exterior temperatures were also recorded. This is similar to other detailed end-use data monitored in the U.S. Pacific Northwest in the ELCAP project (Pratt et al., 1989) and the PG&E Appliance Metering Project (Brodsky and McNicoll, 1987). However these data are of a more recent vintage and from a cooling dominated climate.
The …
Sunsmart Community Partnerships: Summary And Lessons Learned Report, Florida Solar Energy Center, Jennifer Szaro
Sunsmart Community Partnerships: Summary And Lessons Learned Report, Florida Solar Energy Center, Jennifer Szaro
FSEC Energy Research Center®
Through a working partnership with the Florida Municipal Electric Association (FMEA), the Florida Solar Energy Center (FSEC), the Florida Municipal Power Agency (FMPA), the Legal Environmental Assistance Foundation (LEAF), and FMEA member utilities, the SunSmart program offers a unified, low-cost solution to providing municipal electric customers with a solar energy option. It also provides its member utilities with a high level of technical and administrative support to alleviate concerns about working with an unfamiliar electric generation technology. It relies on a core team to develop a standardized marketing and public outreach plan which can be utilized by all participants, and …
Nebraska Summary 387: John Deere 6420 Autoquad Diesel 24-Speed, Nebraska Tractor Test Lab
Nebraska Summary 387: John Deere 6420 Autoquad Diesel 24-Speed, Nebraska Tractor Test Lab
Nebraska Tractor Tests
ABOUT THE TEST REPORT AND USE OF THE DATA
The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data.
EXPLANATION OF THE TEST PROCEDURES
Purpose
The purpose of …
Nebraska Summary: S405 Case-Ih Jx85, Nebraska Tractor Test Lab
Nebraska Summary: S405 Case-Ih Jx85, Nebraska Tractor Test Lab
Nebraska Tractor Tests
ABOUT THE TEST REPORT AND USE OF THE DATA The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data. EXPLANATION OF THE TEST PROCEDURES Purpose The purpose of …
Nebraska Summary 383: Agco Rt130 Diesel, Nebraska Tractor Test Lab
Nebraska Summary 383: Agco Rt130 Diesel, Nebraska Tractor Test Lab
Nebraska Tractor Tests
No abstract provided.
Nebraska Summary 410: Fendt 410 Vario, Nebraska Tractor Test Lab
Nebraska Summary 410: Fendt 410 Vario, Nebraska Tractor Test Lab
Nebraska Tractor Tests
ABOUT THE TEST REPORT AND USE OF THE DATA
The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data.
EXPLANATION OF THE TEST PROCEDURES
Purpose
The purpose of …
Test 1799: John Deere 8320t Diesel 16-Speed, Nebraska Tractor Test Lab
Test 1799: John Deere 8320t Diesel 16-Speed, Nebraska Tractor Test Lab
Nebraska Tractor Tests
ABOUT THE TEST REPORT AND USE OF THE DATA
The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data.
EXPLANATION OF THE TEST PROCEDURES
Purpose
The purpose of …
Test 1808: John Deere 6403 Diesel 9-Speed, Nebraska Tractor Test Lab
Test 1808: John Deere 6403 Diesel 9-Speed, Nebraska Tractor Test Lab
Nebraska Tractor Tests
ABOUT THE TEST REPORT AND USE OF THE DATA
The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data.
EXPLANATION OF THE TEST PROCEDURES
Purpose
The purpose of …
Test 1809: John Deere 6603 Diesel 9-Speed, Nebraska Tractor Test Lab
Test 1809: John Deere 6603 Diesel 9-Speed, Nebraska Tractor Test Lab
Nebraska Tractor Tests
ABOUT THE TEST REPORT AND USE OF THE DATA
The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data.
EXPLANATION OF THE TEST PROCEDURES
Purpose
The purpose of …
Nebraska Summary 384: John Deere 6120 Syncroplus Diesel 12-Speed, Nebraska Tractor Test Lab
Nebraska Summary 384: John Deere 6120 Syncroplus Diesel 12-Speed, Nebraska Tractor Test Lab
Nebraska Tractor Tests
ABOUT THE TEST REPORT AND USE OF THE DATA
The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data.
EXPLANATION OF THE TEST PROCEDURES
Purpose
The purpose of …
Nebraska Summary 386: John Deere 6320 Powrquad Plus 16-Speed, Nebraska Tractor Test Lab
Nebraska Summary 386: John Deere 6320 Powrquad Plus 16-Speed, Nebraska Tractor Test Lab
Nebraska Tractor Tests
ABOUT THE TEST REPORT AND USE OF THE DATA
The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data.
EXPLANATION OF THE TEST PROCEDURES
Purpose
The purpose of …
Test 2097: Mccormick Mtx 110 Diesel, Nebraska Tractor Test Lab
Test 2097: Mccormick Mtx 110 Diesel, Nebraska Tractor Test Lab
Nebraska Tractor Tests
No abstract provided.
Test 2098: Mccormick Mtx 125 Diesel, Nebraska Tractor Test Lab
Test 2098: Mccormick Mtx 125 Diesel, Nebraska Tractor Test Lab
Nebraska Tractor Tests
No abstract provided.