Open Access. Powered by Scholars. Published by Universities.®

Energy Systems Commons™

Open Access. Powered by Scholars. Published by Universities.®

Discipline
Institution
Keyword
Publication Year
Publication
Publication Type
File Type

Articles 2821 - 2850 of 5621

Full-Text Articles in Energy Systems

Cooling Performance Assessment Of Building America Homes, Florida Solar Energy Center, Dave Chasar Jul 2006

Cooling Performance Assessment Of Building America Homes, Florida Solar Energy Center, Dave Chasar

FSEC Energy Research Center®

Long-term monitoring of building energy use and environmental conditions has been a strong component of FSEC research since the 1980s. Fully-automated data collection, verification, archiving and management ensure accurate logging of large amounts of data simultaneously from numerous field sites prior to being made available for analysis and display via the internet. Homes are typically monitored using 15 to 50 channels of data to measure indoor and outdoor environmental conditions and energy use of heating, cooling, water heating, whole house, and other points (e.g. Solar PV or Solar DHW) if needed.

Energy performance in many Building America homes has been …


Energy Performance Aspects Of A Florida Green Roof, Florida Solar Energy Center, Jeffrey Sonne Jul 2006

Energy Performance Aspects Of A Florida Green Roof, Florida Solar Energy Center, Jeffrey Sonne

FSEC Energy Research Center®

Previous green roof studies have found that planted roofs significantly reduce roof temperatures and roof heat flux, and simulations indicate cooling load reductions of up to 25%. This monitored study evaluates summer and winter energy performance aspects of a green roof on a central Florida university building addition that was completed in 2005.

Analysis of 2005 summer data indicates significantly lower peak roof surface temperatures for the green roof compared with the conventional roof and a significant shift in when the peak temperature occurs compared to the conventional roof. Summer roof heat flux estimates show the green roof to have …


Measured Crawlspace Conditions In A Hud-Code Home, Florida Solar Energy Center, David Beal Jul 2006

Measured Crawlspace Conditions In A Hud-Code Home, Florida Solar Energy Center, David Beal

FSEC Energy Research Center®

The Florida Solar Energy Center conducted research utilizing two unconditioned, old, singlewide side-by-side manufactured homes, one with a ground cover and one with exposed dirt under it. Three different skirting options were tested, open or no skirting, perforated skirting, and solid skirting.

Ambient and crawlspace dewpoints were recorded. The data is summarized in the table below. The skirting configurations tested are in Column 1, Column 2 lists the average ambient dewpoint, 3 the ground cover crawlspace, 4 the exposed dirt crawlspace dewpoint.

Successfully sealing HUD code home crawlspaces is the last piece of the puzzle of floor failures plaguing homes …


School Conditions Will Continue To Earn Failing Grades, Florida Solar Energy Center, Jeffrey Sonne Jul 2006

School Conditions Will Continue To Earn Failing Grades, Florida Solar Energy Center, Jeffrey Sonne

FSEC Energy Research Center®

This study addresses indoor air quality and general conditions problems in schools throughout the United States. Tools employed to investigate conditions include a nationwide, web-based survey, characterization of actual operating conditions in schools through field audits and diagnostic tests, and retrofits in problem schools.

Survey results found temperature to be by far the greatest comfort complaint in regular classrooms, with indoor air quality (IAQ) and then humidity being the next greatest areas of complaints. Ventilation problems were found at each of eight audited schools. These problems appear to be occurring due to a combination of factors including lack of maintenance, …


Socio-Economic Impacts Of Computer Viruses In Tanzania, M Victor Jun 2006

Socio-Economic Impacts Of Computer Viruses In Tanzania, M Victor

Tanzania Journal of Engineering and Technology (TJET)

This paper reports on a research project conducted with an objective of identifying and assessing various approaches used by different computer users (Management, System Administrators and end users) in Tanzania to combat computer viruses (CVs), and to assess users' awareness level on CVs. Specifically, the study aimed at assessing the awareness level on CVs to the Tanzanian business community; analyze the socio -economic impact caused by CVs in Tanzania and; assess existing methods, capacity and limitations on controlling CVs in Tanzania. Data was collected using both questionnaires and interview from financial institutions such as NBC and BOT, and telecommunications sector …


Comparison Matrix Of Florida Residential Building Energy Code And The International Energy Conservation Code (Iecc) 2006, Florida Solar Energy Center, Mangesh Basarkar Jun 2006

Comparison Matrix Of Florida Residential Building Energy Code And The International Energy Conservation Code (Iecc) 2006, Florida Solar Energy Center, Mangesh Basarkar

FSEC Energy Research Center®

This report presents a comparison of the differences between the Florida and the IECC (2006) residential energy code requirements. In addition to this summary, the documentation is divided into three sets of distinct comparisons: Comparison of Performance-based methods, Comparison of Prescriptive methods and Comparison of key provisions of the texts. In order to provide the best housing stock, with a code that is easy to implement and enforce, the final recommendation of the study was for Florida to maintain its own code, but consider incorporating some of the newer IECC measures.


Impact Of Solar Powered Disaster-Resistant Communities, Florida Solar Energy Center, William Young Apr 2006

Impact Of Solar Powered Disaster-Resistant Communities, Florida Solar Energy Center, William Young

FSEC Energy Research Center®

Natural and man made disasters can destroy lives, homes, businesses, the economy and the environment. Disasters can happen with little or no warning, leaving hundreds or even thousands of people without medical services, potable water, sanitation, communications and electrical services for up to several weeks. This paper identifies the imperative for and value of creating disaster-resistant homes and communities. The use of renewables, the application of distributed generation, implementation of energy-efficient building designs and construction of disaster-resistant structures can minimize the destruction of property, cost of recovery and disruption of lives. Through enhanced construction practices and the use of solar …


Energy Efficient Process Heating: Insulation And Thermal Mass, Kevin Carpenter, J. Kelly Kissock Apr 2006

Energy Efficient Process Heating: Insulation And Thermal Mass, Kevin Carpenter, J. Kelly Kissock

Mechanical and Aerospace Engineering Faculty Publications

Open tanks and exterior surfaces of process heating equipment lose heat to the surroundings via convection, radiation, and/or evaporation. A practical way of reducing heat loss is by insulating or covering the surfaces. This paper presents methods to quantify heat loss and energy savings from insulating hot surfaces and open tanks. The methods include radiation and evaporation losses, which are ignored by simplified methods. In addition, thermal mass, such as refractory, conveyor and racking equipment, acts as a heat sink and increases heating energy use in process heating applications. This paper presents lumped capacitance and finite-difference methods for estimating heat …


Solar Energy Conversion Through Seaweed Photosynthesis With Combustion In A Zero-Emission Power Plant, Evgeny Yantovski, Jim Mcgovern Apr 2006

Solar Energy Conversion Through Seaweed Photosynthesis With Combustion In A Zero-Emission Power Plant, Evgeny Yantovski, Jim Mcgovern

Other resources

A proposed ‘closed cycle’ power plant scheme, referred to as SOFT (Solar Oxygen Fuel Turbine), is described. The scheme involves the cultivation of macroalgae in a pond, combustion of their organic matter in a fluidised bed boiler that generates steam for a Rankine cycle steam power plant and the return of the combustion products to the pond to feed the algae. Oxygen, equivalent to that used for combustion, is re-released to the atmosphere by photosynthesis, while the carbon dioxide that is produced by combustion is absorbed by photosynthesis and thereby recycled. It is proposed that the seaweed Ulva, which is …


Energy Efficient Process Heating: Managing Air Flow, Kevin Carpenter, J. Kelly Kissock Apr 2006

Energy Efficient Process Heating: Managing Air Flow, Kevin Carpenter, J. Kelly Kissock

Mechanical and Aerospace Engineering Faculty Publications

Much energy is lost through excess air flow in and out of process heating equipment. Energy saving opportunities from managing air flow include minimizing combustion air, preheating combustion air, minimizing ventilation air, and reconfiguring openings to reduce leakage.

This paper identifies these opportunities and presents methods to quantify potential energy savings from implementing these energy-savings measures. Case study examples are used to demonstrate the methods and the potential energy savings.The method for calculating savings from minimizing combustion air accounts for improvement in efficiency from increased combustion temperature and decreased combustion gas mass flow rate.

The method for calculating savings from …


Potential Of Energy Efficiency And Renewable Energy Savings To Impact Florida's Projected Energy Use In 2014, Florida Solar Energy Center, Philip W. Fairey Feb 2006

Potential Of Energy Efficiency And Renewable Energy Savings To Impact Florida's Projected Energy Use In 2014, Florida Solar Energy Center, Philip W. Fairey

FSEC Energy Research Center®

Florida's 2004 electrical energy use was 233 billion kilowatt-hours. Over half (51%) of this energy use went to residential building energy. The state's current 10-year predictions for electrical energy use in 2014 show a requirement for approximately 308 billion kilowatt-hours of electricity, an increase of approximately 75 billion kilowatt-hours. This study presents an example of how Florida can radically alter its 2014 energy use projection by aggressively pursuing residential building energy efficiency improvements and aggressively increasing its use of proven renewable energy resources.


Unbalanced Return Air In Residences: Causes, Consequences, And Solutions, Florida Solar Energy Center, James Cummings Jan 2006

Unbalanced Return Air In Residences: Causes, Consequences, And Solutions, Florida Solar Energy Center, James Cummings

FSEC Energy Research Center®

Field research performed in 70 central Florida homes found that return grills are almost always located in the central zone of the house, and that individual rooms rarely have ducted return air or return transfer pathways. When interior doors were closed, the closed rooms went to +0.0249 inches of water gauge (in w.g.) (+6.2 pascals (Pa)) wrt outdoors (wrt = with respect to), and the central zone went to -0.0116 in w.g. (-2.9 Pa) wrt outdoors. Room pressures as high as +0.150 in w.g. (+37.3 Pa) and central zone pressure as low as -0.059 in w.g. (-14.7 Pa) wrt outdoors …


Unbalanced Return Air In Commercial Buildings, Florida Solar Energy Center, Charles Withers, Jr. Jan 2006

Unbalanced Return Air In Commercial Buildings, Florida Solar Energy Center, Charles Withers, Jr.

FSEC Energy Research Center®

Research in 88 central Florida commercial buildings during the last decade has found that 26% of the air distribution systems had substantially unbalanced return air. Unbalanced return air occurs when there is a restriction to air flow between the supply discharge and the return air, creating positive and negative pressure fields throughout the building. Severe consequences in commercial buildings can occur as a result of unbalanced air flows. This paper examines unbalanced return air and its consequences in three commercial buildings, and explains why balancing air flow in buildings is a critical part of maintaining a healthy and energy efficient …


Understanding The Dehumidification Performance Of Air-Conditioning Equipment At Part-Load Conditions, Florida Solar Energy Center, Don B. Shirey Iii Jan 2006

Understanding The Dehumidification Performance Of Air-Conditioning Equipment At Part-Load Conditions, Florida Solar Energy Center, Don B. Shirey Iii

FSEC Energy Research Center®

Air conditioner cooling coils typically provide both sensible cooling and moisture removal. Data from a limited number of field studies (Khattar et al. 1985; Henderson and Rengarajan 1996; Henderson 1998) have demonstrated that the moisture removal capacity of a cooling coil degrades at part-load conditions - especially when the supply fan operates continuously while the cooling coil cycles on and off. Degradation occurs because moisture that condenses on the coil surfaces during the cooling cycle evaporates back into air stream when the coil is off. This degradation affects the ability of cooling equipment to maintain proper indoor humidity levels and …


Abstract/Conclusion: Understanding The Dehumidification Performance Of Air-Conditioning Equipment At Part-Load Conditions, Florida Solar Energy Center, Don B. Shirey Iii Jan 2006

Abstract/Conclusion: Understanding The Dehumidification Performance Of Air-Conditioning Equipment At Part-Load Conditions, Florida Solar Energy Center, Don B. Shirey Iii

FSEC Energy Research Center®

Air conditioner cooling coils typically provide both sensible cooling and moisture removal. Data from a limited number of field studies (Khattar et al. 1985; Henderson and Rengarajan 1996; Henderson 1998) have demonstrated that the moisture removal capacity of a cooling coil degrades at part-load conditions, especially when the supply fan operates continuously while the cooling coil cycles on and off. Degradation occurs because moisture that condenses on the coil surfaces during the cooling cycle evaporates back into air stream when the coil is off. This degradation affects the ability of cooling equipment to maintain proper indoor humidity levels and may …


Test 1880: Mccormick Xtx 185/Mccormick Mtx 165 Diesel, Nebraska Tractor Test Lab Jan 2006

Test 1880: Mccormick Xtx 185/Mccormick Mtx 165 Diesel, Nebraska Tractor Test Lab

Nebraska Tractor Tests

No abstract provided.


Test 1891: Kubota L5030 Diesel, Nebraska Tractor Test Lab Jan 2006

Test 1891: Kubota L5030 Diesel, Nebraska Tractor Test Lab

Nebraska Tractor Tests

No abstract provided.


Test 1881: Mccormick Xtx 200/Mtx 185 Diesel, Nebraska Tractor Test Lab Jan 2006

Test 1881: Mccormick Xtx 200/Mtx 185 Diesel, Nebraska Tractor Test Lab

Nebraska Tractor Tests

No abstract provided.


Test 1875: Challenger Mt 635b Diesel, Nebraska Tractor Test Lab Jan 2006

Test 1875: Challenger Mt 635b Diesel, Nebraska Tractor Test Lab

Nebraska Tractor Tests

No abstract provided.


Test 1878: Challenger Mt 665b Diesel, Nebraska Tractor Test Lab Jan 2006

Test 1878: Challenger Mt 665b Diesel, Nebraska Tractor Test Lab

Nebraska Tractor Tests

No abstract provided.


Test 1883: Agco Lt75a Diesel, Nebraska Tractor Test Lab Jan 2006

Test 1883: Agco Lt75a Diesel, Nebraska Tractor Test Lab

Nebraska Tractor Tests

No abstract provided.


Test 1889: John Deere 8430t 16 Speed, Nebraska Tractor Test Lab Jan 2006

Test 1889: John Deere 8430t 16 Speed, Nebraska Tractor Test Lab

Nebraska Tractor Tests

No abstract provided.


Test 1871: John Deere 5203 Diesel 9-Speed, Nebraska Tractor Test Lab Jan 2006

Test 1871: John Deere 5203 Diesel 9-Speed, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA

The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data.

EXPLANATION OF THE TEST PROCEDURES

Purpose

The purpose of …


Test 1870: John Deere 5103 Diesel 9-Speed, Nebraska Tractor Test Lab Jan 2006

Test 1870: John Deere 5103 Diesel 9-Speed, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA

The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data.

EXPLANATION OF THE TEST PROCEDURES

Purpose

The purpose of …


Test 1884: John Deere 8130 Diesel 16-Speed, Nebraska Tractor Test Lab Jan 2006

Test 1884: John Deere 8130 Diesel 16-Speed, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA

The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data.

EXPLANATION OF THE TEST PROCEDURES

Purpose

The purpose of …


Test 1888: John Deere 8330t Diesel 16-Speed, Nebraska Tractor Test Lab Jan 2006

Test 1888: John Deere 8330t Diesel 16-Speed, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA

The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data.

EXPLANATION OF THE TEST PROCEDURES

Purpose

The purpose of …


Test 1887: John Deere 8330 Diesel 16-Speed, Nebraska Tractor Test Lab Jan 2006

Test 1887: John Deere 8330 Diesel 16-Speed, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA

The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data.

EXPLANATION OF THE TEST PROCEDURES

Purpose

The purpose of …


Test 1885: John Deere 8230 Diesel 16-Speed, Nebraska Tractor Test Lab Jan 2006

Test 1885: John Deere 8230 Diesel 16-Speed, Nebraska Tractor Test Lab

Nebraska Tractor Tests

ABOUT THE TEST REPORT AND USE OF THE DATA

The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data.

EXPLANATION OF THE TEST PROCEDURES

Purpose

The purpose of …


Test 1882: Mccormick Xtx 215 Diesel, Nebraska Tractor Test Lab Jan 2006

Test 1882: Mccormick Xtx 215 Diesel, Nebraska Tractor Test Lab

Nebraska Tractor Tests

No abstract provided.


Test 1876: Challenger Mt 645b Diesel, Nebraska Tractor Test Lab Jan 2006

Test 1876: Challenger Mt 645b Diesel, Nebraska Tractor Test Lab

Nebraska Tractor Tests

No abstract provided.