Open Access. Powered by Scholars. Published by Universities.®

Discipline
Institution
Keyword
Publication Year
Publication
Publication Type
File Type

Articles 661 - 683 of 683

Full-Text Articles in Bioimaging and Biomedical Optics

Compact Supercell Method Based On Opposite Parity For Bragg Fibers, Wang Zhi, Ren Guobin, Lou Shuquin, Liang Weijun, Shangping Guo Jan 2003

Compact Supercell Method Based On Opposite Parity For Bragg Fibers, Wang Zhi, Ren Guobin, Lou Shuquin, Liang Weijun, Shangping Guo

Electrical & Computer Engineering Faculty Publications

The supercell- based orthonormal basis method is proposed to investigate the modal properties of the Bragg fibers. A square lattice is constructed by the whole Bragg fiber which is considered a supercell, and the periodical dielectric structure of the square lattice is decomposed using periodic functions (cosine). The modal electric field is expanded as the sum of the orthonormal set of Hermite-Gaussian basis functions based on the opposite parity of the transverse electric field. The propagation characteristics of Bragg fibers can be obtained after recasting the wave equation into an eigenvalue system. This method is implemented with very high efficiency …


Implementation Of Gy-Eq For Deterministic Effects Limitation In Shield Design, John W. Wilson, Myung-Hee Y. Kim, Giovanni De Angelis, Francis A. Cucinotta, Nobuaki Yoshizawa, Francis F. Badavi Dec 2002

Implementation Of Gy-Eq For Deterministic Effects Limitation In Shield Design, John W. Wilson, Myung-Hee Y. Kim, Giovanni De Angelis, Francis A. Cucinotta, Nobuaki Yoshizawa, Francis F. Badavi

Mathematics & Statistics Faculty Publications

The NCRP has recently defined RBE values and a new quantity (Gy-Eq) for use in estimation of deterministic effects in space shielding and operations. The NCRP's RBE for neutrons is left ambiguous and not fully defined. In the present report we will suggest a complete definition of neutron RBE consistent with the NCRP recommendations and evaluate attenuation properties of deterministic effects (Gy-Eq) in comparison with other dosimetric quantities.


In Vivo Flow Dynamics Of The Total Cavopulmonary Connection From Three-Dimensional Multislice Magnetic Resonance Imaging, Shiva Sharma, Ann E. Ensley, Katherine Hopkins, George P. Chatzimavroudis, Timothy M. Healy, Vincent K.H. Tam, Kirk R. Kanter, Ajit P. Yoganathan Mar 2001

In Vivo Flow Dynamics Of The Total Cavopulmonary Connection From Three-Dimensional Multislice Magnetic Resonance Imaging, Shiva Sharma, Ann E. Ensley, Katherine Hopkins, George P. Chatzimavroudis, Timothy M. Healy, Vincent K.H. Tam, Kirk R. Kanter, Ajit P. Yoganathan

Chemical & Biomedical Engineering Faculty Publications

Background. The total cavopulmonary connection (TCPC) design continues to be refined on the basis of flow analysis at the connection site. These refinements are of importance for myocardial energy conservation in the univentricular supported circulation. In vivo magnetic resonance phase contrast imaging provides semiquantitative flow visualization information. The purpose of this study was to understand the in vivo TCPC flow characteristics obtained by magnetic resonance phase contrast imaging and compare the results with our previous in vitro TCPC flow experiments in an effort to further refine TCPC surgical design.

Methods. Twelve patients with TCPC underwent sedated three-dimensional, multislice …


Is Extended Volume Of External Beam Irradiation Beneficial In Post-Esophagectomy High Risk Patients Receiving Combined Chemoradiation Therapy?, E. Yu, A. R. Dar, R. Ash, G. Videtic, P. Truong, L. Stitt, A. Tomiak, M. Vincent, R. Malthaner, I. Craig, E. Brecevic, W. Kocha, R. Inculet, M. Lefcoe Jan 2001

Is Extended Volume Of External Beam Irradiation Beneficial In Post-Esophagectomy High Risk Patients Receiving Combined Chemoradiation Therapy?, E. Yu, A. R. Dar, R. Ash, G. Videtic, P. Truong, L. Stitt, A. Tomiak, M. Vincent, R. Malthaner, I. Craig, E. Brecevic, W. Kocha, R. Inculet, M. Lefcoe

Oncology Presentations

OBJECTIVE: To assess the value of extended volume irradiation with anastomotic coverage in high risk resected esophageal cancer patients.

METHOD: A retrospective study was undertaken at LRCC from 1989-1999 for high risk resected esophageal cancer patients. Adjuvant treatments consisted of 4 cycles of chemotherapy (epirubicin/fluorouracil/cisplatin or cisplatin/fluorouracil), and local regional irradiation with or without coverage of the anastomotic site. Radiation dose ranged from 45-60Gy at 1.8-2.0 Gy/fraction given with initial anterior-posterior/posterior-anterior arrangement with either extended (with anastomotic coverage) or small (without anastomotic coverage) field followed by oblique fields for boost.

RESULT: One hundred eighty-eight charts were reviewed. Seventy-two patients were …


Fluid Mechanic Assessment Of The Total Cavopulmonary Connection Using Magnetic Resonance Phase Velocity Mapping And Digital Particle Image Velocimetry, Ann E. Ensley, Agnès Ramuzat, Timothy M. Healy, George P. Chatzimavroudis, Carol Lucas, Shiva Sharma, Roderic Pettigrew, Ajit P. Yoganathan Oct 2000

Fluid Mechanic Assessment Of The Total Cavopulmonary Connection Using Magnetic Resonance Phase Velocity Mapping And Digital Particle Image Velocimetry, Ann E. Ensley, Agnès Ramuzat, Timothy M. Healy, George P. Chatzimavroudis, Carol Lucas, Shiva Sharma, Roderic Pettigrew, Ajit P. Yoganathan

Chemical & Biomedical Engineering Faculty Publications

The total cavopulmonary connection (TCPC) is currently the most promising modification of the Fontan surgical repair for single ventricle congenital heart disease. The TCPC involves a surgical connection of the superior and inferior vena cavae directly to the left and right pulmonary arteries, bypassing the right heart. In the univentricular system, the ventricle experiences a workload which may be reduced by optimizing the cavae-to-pulmonary anastomosis. The hypothesis of this study was that the energetic efficiency of the connection is a consequence of the fluid dynamics which develop as a function of connection geometry. Magnetic resonance phase velocity mapping (MRPVM) and …


Applications Of Wavelet Transforms In Biomedical Optoacoustics, Zibiao Wei, Shujun Yang, Amin N. Dharamsi, Barbara Hargrave Jan 2000

Applications Of Wavelet Transforms In Biomedical Optoacoustics, Zibiao Wei, Shujun Yang, Amin N. Dharamsi, Barbara Hargrave

Biological Sciences Faculty Publications

We discuss the utility of wavelet transform methods in signal processing in general, and in particular, demonstrate the technique in optoacoustic applications. In several optoacoustic experiments with different samples, we have successfully enhanced the signal to noise ratios. Wavelet transforms optimize resolution by utilizing a tailored, variable time-window in different frequency regions. The technique's great advantage lies in the fact that the wavelet transform adds some redundancy to the original signal, and some desired features can be enhanced in the transformed space. In addition, proper choice of the basis set allows a sparse representation of the signal. Therefore, even when …


Mri Techniques For Cardiovascular Imaging, Roderic I. Pettigrew, John N. Oshinski, George P. Chatzimavroudis, W. Thomas Dixon Nov 1999

Mri Techniques For Cardiovascular Imaging, Roderic I. Pettigrew, John N. Oshinski, George P. Chatzimavroudis, W. Thomas Dixon

Chemical & Biomedical Engineering Faculty Publications

Over the last several years, cardiovascular MRI has benefited from a number of technical advances which have improved routine clinical imaging techniques. As a result, MRI is now well positioned to realize its longstanding promise of becoming the comprehensive cardiac imaging test of choice in many clinical settings. This may be achieved using a combination of basic advanced techniques. In this overview, the basic cardiac MRI techniques which are clinically useful are reviewed, and the recent technical advances which are clinically promising are described. These advances include routine black blood and cine bright blood techniques that are high speed (slice), …


Toward Designing The Optimal Total Cavopulmonary Connection: An In Vitro Study, Ann E. Ensley, Patricia Lynch, George P. Chatzimavroudis, Carol Lucas, Shiva Sharma, Ajit P. Yoganathan Oct 1999

Toward Designing The Optimal Total Cavopulmonary Connection: An In Vitro Study, Ann E. Ensley, Patricia Lynch, George P. Chatzimavroudis, Carol Lucas, Shiva Sharma, Ajit P. Yoganathan

Chemical & Biomedical Engineering Faculty Publications

Background. Understanding the total cavopulmonary connection (TCPC) hemodynamics may lead to improved surgical procedures which result in a more efficient modified circulation. Reduced energy loss will translate to less work for the single ventricle and although univentricular physiology is complex, this improvement could contribute to improved postoperative outcomes. Therefore to conserve energy, one surgical goal is optimization of the TCPC geometry. In line with this goal, this study investigated whether addition of caval curvature or flaring at the connection conserves energy.

Methods. TCPC models were made varying the curvature of the caval inlet or by flaring the anastomosis. …


Quantification Of Mitral Regurgitation With Mr Phase-Velocity Mapping Using A Control Volume Method, George P. Chatzimavroudis, John N. Oshinski, Roderic I. Pettigrew, Peter G. Walker, Robert H. Franch, Ajit P. Yoganathan May 1998

Quantification Of Mitral Regurgitation With Mr Phase-Velocity Mapping Using A Control Volume Method, George P. Chatzimavroudis, John N. Oshinski, Roderic I. Pettigrew, Peter G. Walker, Robert H. Franch, Ajit P. Yoganathan

Chemical & Biomedical Engineering Faculty Publications

Reliable diagnosis and quantification of mitral regurgitation are important for patient management and for optimizing the time for surgery. Previous methods have often provided suboptimal results. The aim of this in vitro study was to evaluate MR phase-velocity mapping in quantifying the mitral regurgitant volume (MRV) using a control volume (CV) method. A number of contiguous slices were acquired with all three velocity components measured. A CV was then selected, encompassing the regurgitant orifice. Mass conservation dictates that the net inflow into the CV should be equal to the regurgitant flow. Results showed that a CV, the boundary voxels of …


Slice Location Dependence Of Aortic Regurgitation Measurements With Mr Phase Velocity Mapping, George P. Chatzimavroudis, Peter G. Walker, John N. Oshinski, Robert H. Franch, Roderic I. Pettigrew, Ajit P. Yoganathan Apr 1997

Slice Location Dependence Of Aortic Regurgitation Measurements With Mr Phase Velocity Mapping, George P. Chatzimavroudis, Peter G. Walker, John N. Oshinski, Robert H. Franch, Roderic I. Pettigrew, Ajit P. Yoganathan

Chemical & Biomedical Engineering Faculty Publications

Although several methods have been used clinically to assess aortic regurgitation (AR), there is no “gold standard” for regurgitant volume measurement. Magnetic resonance phase velocity mapping (PVM) can be used for noninvasive blood flow measurements. To evaluate the accuracy of PVM in quantifying AR with a single imaging slice in the ascending aorta, in vitro experiments were performed by using a compliant aortic model. Attention was focused on determining the slice location that provided the best results. The most accurate measurements were taken between the aortic valve annulus and the coronary ostia where the measured (Y) and actual …


Evaluation Of Segmentation For Bone Structures In 3d Rendering Of Ultrasound Residual Limb Images, Min C. Baker Dec 1996

Evaluation Of Segmentation For Bone Structures In 3d Rendering Of Ultrasound Residual Limb Images, Min C. Baker

Theses and Dissertations

Prosthetists today widely practice manual socket fitting, which produces subjective, inconsistent results. To address this problem, the Computerized Anthropometry Research and Design (CARD) Laboratory is developing a computer-aided socket design system that acquires ultrasound datasets of an amputee's residual limb, creates a 3D model, and helps identify load- bearing and pressure-relief areas. This research project focuses on providing 3D visualization of a residual limb to support the CARD Laboratory's efforts. Creating the 3D model of the skin and two bone contours requires two major steps: segmentation to identify the objects of interest and a surface tracking algorithm to generate the …


Pulse Coupled Neural Networks For The Segmentation Of Magnetic Resonance Brain Images, Shane L. Abrahamson Dec 1996

Pulse Coupled Neural Networks For The Segmentation Of Magnetic Resonance Brain Images, Shane L. Abrahamson

Theses and Dissertations

This research develops an automated method for segmenting Magnetic Resonance (MR) brain images based on Pulse Coupled Neural Networks (PCNN). MR brain image segmentation has proven difficult, primarily due to scanning artifacts such as interscan and intrascan intensity inhomogeneities. The method developed and presented here uses a PCNN to both filter and segment MR brain images. The technique begins by preprocessing images with a PCNN filter to reduce scanning artifacts. Images are then contrast enhanced via histogram equalization. Finally, a PCNN is used to segment the images to arrive at the final result. Modifications to the original PCNN model are …


Clustered Microcalcification Detection Using Optimized Difference Of Gaussians, Edward M. Ochoa Dec 1996

Clustered Microcalcification Detection Using Optimized Difference Of Gaussians, Edward M. Ochoa

Theses and Dissertations

The objective of this thesis is to design an automated microcalcification detection system to be used as an aid in radiologic mammogram interpretation. This research proposes the following methodology for clustered microcalcification detection. First, preprocess the digitized film mammogram to reduce digitization noise. Second, spatially filter the image with a difference of Gaussians (DoG) kernel. To detect potential microcalcifications, segment the filtered image using global and local thresholding. Next, cluster and index these detections into regions of interest (ROIs). Identify ROIs on the digitized image (or hardcopy printout) for final radiologic diagnosis.


Using Kriging To Interpolate Spatially Distributed Volumetric Medical Data, Stephen M. Matechik Dec 1996

Using Kriging To Interpolate Spatially Distributed Volumetric Medical Data, Stephen M. Matechik

Theses and Dissertations

Routine cases in diagnostic radiology require the interpolation of volumetric medical imaging data sets. Inaccurate renditions of interpolated volumes can lead to the misdiagnosis of a patient's condition. It is therefore essential that interpolated modality space estimates accurately portray patient space. Kriging is investigated in this research to interpolate medical imaging volumes. Kriging requires data to be spatially distributed. Therefore, magnetic resonance imaging (MRI) data is shown to exhibit spatially regionalized characteristics such that it can be modeled using regionalized variables and subsequently be interpolated using kriging. A comprehensive, automated, three-dimensional structural analysis of the MRI data is accomplished to …


Validation Of Energy Dispersive X-Ray Spectrometry As A Method To Standardize Backscattered Electron Images Of Bone, E. G. Vajda, R. D. Bloebaum, J. G. Skedros Jan 1996

Validation Of Energy Dispersive X-Ray Spectrometry As A Method To Standardize Backscattered Electron Images Of Bone, E. G. Vajda, R. D. Bloebaum, J. G. Skedros

Cells and Materials

The use of backscattered electron (BSE) imaging as a tool for the qualitative measurement of mineral content in bone has been well documented. The challenge still remains to develop BSE imaging as a tool for quantitative mineral content analysis in bone. The limiting factor has been the ability to standardize the BSE signal within and between laboratories. Energy dispersive x-ray spectrometry (EDX) has been proposed as a method to standardize the BSE operating environment. The goal of this study is to investigate the relationship between EDX-determined wt.% Ca measurements and BSE graylevels. A comparison with traditional ash content measurements will …


The Influence Of Acoustic Impedance Mismatch On Post-Stenotic Pulsed-Doppler Ultrasound Measurements In A Coronary Artery Model, S. A. Jones, H. Leclerc, George P. Chatzimavroudis, Y. H. Kim, N. A. Scott, Ajit P. Yoganathan Jan 1996

The Influence Of Acoustic Impedance Mismatch On Post-Stenotic Pulsed-Doppler Ultrasound Measurements In A Coronary Artery Model, S. A. Jones, H. Leclerc, George P. Chatzimavroudis, Y. H. Kim, N. A. Scott, Ajit P. Yoganathan

Chemical & Biomedical Engineering Faculty Publications

Acoustic impedance mismatch at the fluid-wall interface was shown to affect the spectra from an intravascular Doppler device in an in vitro model with a diameter typical of human coronary arteries. Measurements were obtained first under Poiseuille flow conditions with impedance mismatches of 0%, 7% and 12%, and then under stenosed conditions for the 0% and 7% mismatch cases. For the zero mismatch case, the Doppler spectra could be readily interpreted in terms of fluid mechanical phenomena. When mismatch was present, the spectra from Poiseuille flow exhibited multiple peaks which could not be directly related to the velocity profile. Also, …


Computer Aided Detection Of Microcalcifications Utilizing Texture Analysis, Ronald C. Dauk Dec 1995

Computer Aided Detection Of Microcalcifications Utilizing Texture Analysis, Ronald C. Dauk

Theses and Dissertations

A comparative study of texture measures for the classification of breast tissue is presented. The texture features investigated include Angular Second Moments, Power Spectrum Analysis and a novel feature, Laws Energy Ratios. The texture study was accomplished as part of the development of a Model Based Vision (MBV) system for the automatic detection of microcalcifications. An overview of the Microcalcification Detection System is presented, which applies image differencing techniques, feature selection methods, and neural networks for locating microcalcification clusters in mammograms. The Power Spectrum Analysis feature set had the best overall performance with an 83% Probability of Detection and an …


Three Dimensional Localization Of Lesions From Digitized Mammograms, Amy L. Magnus Dec 1995

Three Dimensional Localization Of Lesions From Digitized Mammograms, Amy L. Magnus

Theses and Dissertations

This thesis describes new algorithms to localize regions-of-interests (ROIs) three dimensionally from a pair of digitized mammograms. This work is intended to add a layer of sophistication to computer aided diagnosis by putting to use the fixed and measurable parameters of mammographic imaging. The fixed parameters are the source to film orientation and the podium-image distance. Measurable parameters are the rotation angle of the x-ray tube from the horizontal and the compression depth (the distance from compression paddle to contact podium distance) at the time of imaging. As an additional benefit, three dimensional localization algorithms alleviate the confusion radiologists may …


Detection Of Clustered Microcalcifications Using Wavelets, Donald A. Mccandless Dec 1995

Detection Of Clustered Microcalcifications Using Wavelets, Donald A. Mccandless

Theses and Dissertations

An automated method for detecting microcalcification clusters is presented. The algorithm begins with a digitized mammogram and outputs the center coordinates of regions of interest (ROIs) that contain microcalcification clusters. The method presented uses a 12-tap Least Asymmetric Daubechies (LAD12) wavelet in a tree structured filter bank to increase the signal to noise level of microcalcifications. The signal to noise level gain achieved by the filtering allows subsequent thresholding to eliminate on average 90% of the image from further consideration without eliminating actual microcalcifications 95% of the time. A novel approach to isolating individual calcifications from background tissue through non-stationary …


Computer-Aided Diagnosis Of Mammographic Masses, William E. Polakowski Dec 1995

Computer-Aided Diagnosis Of Mammographic Masses, William E. Polakowski

Theses and Dissertations

A new Model-Based Vision algorithm was developed to find possibly cancerous regions of interest (ROIs) in digitized mammograms and to correctly identify the malignant masses. This work has shown a sensitivity of 92 percent for locating malignant ROIs. The database contained 272 images (12 bit, 1OO microns) with 36 malignant and 53 benign mass images. Of the 53 biopsied benign cases, 74 percent were correctly classified. The Focus of Attention (segmentation) Module algorithm used a physiologically motivated Difference of Gaussians (DoG) filter to highlight mass-like regions in the mammogram. The Index Module labeled the regions by their hypothesized class: large …


Evaluation Of Scalar Value Estimation Techniques For 3d Medical Imaging, Rob W. Parrott Dec 1991

Evaluation Of Scalar Value Estimation Techniques For 3d Medical Imaging, Rob W. Parrott

Theses and Dissertations

Scalar value estimation in 3D medical imaging increases data resolution for enhanced renditions and corrects inaccurate surface formations. Accurate estimations are vital because clinical assessment is often aided by examination of 3D medical images. This thesis explores different estimation techniques and introduces the geostatistical estimation technique called kriging to the field of 3D imaging. Kriging theory claims to be the optimal estimator-- better than the standard deterministic methods commonly used. The techniques investigated are linear interpolation, trilinear interpolation, tricubic interpolation, and kriging. This research investigates scalar value estimation in the volume pre-processing operation of slice interpolation and in a surface …


Determination Of Lead Content In Apical Tissue Following Root Canal Obturation With Sargenti's Formula, G. Merle Hickok May 1976

Determination Of Lead Content In Apical Tissue Following Root Canal Obturation With Sargenti's Formula, G. Merle Hickok

Loma Linda University Electronic Theses, Dissertations & Projects

Four Stump-tail monkeys were used to help determine if the lead in Sargenti's formula diffuses out into the apical tissue while confined entirely within the root canal. In each animal two teeth were filled with Sargenti's formula 1-2 millimeters short of the radiographic apex, and two teeth were filled with gutta percha and Proco-Sol sealer for controls, making a total sample size of sixteen. The time ranged from 48 hours to 120 days. Lead analysis using the spectrophotometric method showed a higher lead content in the teeth filled with Sargenti's formula than with the gutta percha controls.


Soft X-Rays, William F. Roherty Jun 1950

Soft X-Rays, William F. Roherty

Bachelors’ Theses

Traditionally, radiation of those wavelengths produced by a potential of from 2 to 25kv. has been classified as "Grenz" or "soft" x-rays. The peculiar property of this radiation is its low penetrating power. While being transparent to more energetic radiation, animal tissue and similar materials are sufficiently opaque to Grenz rays as to be studied in detail. Since the radiation is of the continuous type, it can be made soft enough to reveal any object, providing, of course, that the tube window and object medium be not opaque. Soft x-rays are produced in exactly the same manner as others, except …