Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 6 of 6

Full-Text Articles in Bioimaging and Biomedical Optics

Methodology Development For Three-Dimensional Mr-Guided Near Infrared Spectroscopy Of Breast Tumors, Colin M. Carpenter, Subhadra Srinivasan, Brian W. Pogue, Keith D. Paulsen Oct 2008

Methodology Development For Three-Dimensional Mr-Guided Near Infrared Spectroscopy Of Breast Tumors, Colin M. Carpenter, Subhadra Srinivasan, Brian W. Pogue, Keith D. Paulsen

Dartmouth Scholarship

Combined Magnetic Resonance (MR) and Near Infrared Spectroscopy (NIRS) has been proposed as a unique method to quantify hemodynamics, water content, and cellular size and packing density of breast tumors, as these tissue constituents can be quantified with increased resolution and overlaid on the structural features identified by the MR. However, the choices in how to reconstruct and visualize this information can have a dramatic impact on the feasibility of implementing this modality in the clinic. This is especially true in 3 dimensions, as there is often limited optical sampling of the breast tissue, and methods need to accurately reflect …


Cephalometric Analysis Using Magnetic Resonance Imaging, Wade A. Williams Sep 2008

Cephalometric Analysis Using Magnetic Resonance Imaging, Wade A. Williams

Loma Linda University Electronic Theses, Dissertations & Projects

Purpose: The purpose of this study was to determine if T1-weighted 3D magnetic resonance images performed at 3.0 Tesla could be used to conduct routine orthodontic cephalometric analysis.

Methods: Three cranial imaging methods were compared using sixteen non-growing subjects (10 male and 6 female) who were not claustrophobic, did not have any metallic restorations on the distal of first molars, had no medical implants and the female subjects were not pregnant. Sagittal cranial images were produced by three methods: (1) a digital lateral cephalometric (LC) radiograph (Orthophos XG Plus, SironaTM, Bensheim, Germany), (2) a 12-inch FOV cone beam …


Image-Guided Raman Spectroscopic Recovery Of Canine Cortical Bone Contrast In Situ, Subhadra Srinivasan, Matthew Schulmerich, Jacqueline H. Cole, Kathryn Dooley, Jaclynn M. Kreider, Brian W. Pogue Aug 2008

Image-Guided Raman Spectroscopic Recovery Of Canine Cortical Bone Contrast In Situ, Subhadra Srinivasan, Matthew Schulmerich, Jacqueline H. Cole, Kathryn Dooley, Jaclynn M. Kreider, Brian W. Pogue

Dartmouth Scholarship

Raman scattering provides valuable biochemical and molecular markers for studying bone tissue composition with use in predicting fracture risk in osteoporosis. Raman tomography can image through a few centimeters of tissue but is limited by low spatial resolution. X-ray computed tomography (CT) imaging can provide high-resolution image-guidance of the Raman spectroscopic characterization, which enhances the quantitative recovery of the Raman signals, and this technique provides additional information to standard imaging methods. This hypothesis was tested in data measured from Teflon tissue phantoms and from a canine limb. Image-guided Raman spectroscopy (IG-RS) of the canine limb using CT images of the …


Medical Image Modeling And Processing, Ramu Pedada Jul 2008

Medical Image Modeling And Processing, Ramu Pedada

Electrical & Computer Engineering Theses & Dissertations

During the last few decades of the twentieth century, medical imaging has been playing a prominent role in many fields of biomedical research and clinical practice. Image modalities such as x-rays, computed tomography (CT), and magnetic resonance images (MRI) have all been valuable additions to the radiologist's arsenal of imaging tools. Medical images assure quality diagnosis and patient safety by gathering valuable information without invading the human body. Apart from clinical diagnosis, medical images are used as tools for education where they are used for training individuals before operating on a patient. Many medical educators tum to simulation based training …


Fluorescence Tomography Characterization For Sub-Surface Imaging With Protoporphyrin Ix, Dax Kepshire, Scott C. Davis, Hamid Dehghani, Keith D. Paulsen, Brian W. Pogue Jun 2008

Fluorescence Tomography Characterization For Sub-Surface Imaging With Protoporphyrin Ix, Dax Kepshire, Scott C. Davis, Hamid Dehghani, Keith D. Paulsen, Brian W. Pogue

Dartmouth Scholarship

Optical imaging of fluorescent objects embedded in a tissue simulating medium was characterized using non-contact based approaches to fluorescence remittance imaging (FRI) and sub-surface fluorescence diffuse optical tomography (FDOT). Using Protoporphyrin IX as a fluorescent agent, experiments were performed on tissue phantoms comprised of typical in-vivo tumor to normal tissue contrast ratios, ranging from 3.5:1 up to 10:1. It was found that tomographic imaging was able to recover interior inclusions with high contrast relative to the background; however, simple planar fluorescence imaging provided a superior contrast to noise ratio. Overall, FRI performed optimally when the object was located on or …


An Approach To Identifying The Biomechanical Differences Between Intercostal Cartilage In Subjects With Pectus Excavatum And Normals In Vivo: Reconstruction And Ct Registration, Zhenzhen Yan Apr 2008

An Approach To Identifying The Biomechanical Differences Between Intercostal Cartilage In Subjects With Pectus Excavatum And Normals In Vivo: Reconstruction And Ct Registration, Zhenzhen Yan

Electrical & Computer Engineering Theses & Dissertations

Pectus excavatum (PE) is a congenital chest wall deformity affecting the ribs and sternum and exhibiting a concave appearance in the anterior chest wall. In this thesis, we describe a study to investigate in vivo differences in the pectus excavatum rib cage and outline steps using normals and pectus patients data in developing models and methods to be used in carrying out the study. We propose methods to develop reconstructed models in order to enable proper registration between data collection points (DCPs) on the 3D CT rib cage model and CT skin surface model and registration between CT surrogate models …