Open Access. Powered by Scholars. Published by Universities.®
Bioimaging and Biomedical Optics Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Bioelectrical and Neuroengineering (2)
- Biological Engineering (2)
- Biomechanics and Biotransport (2)
- Mechanical Engineering (2)
- Medicine and Health Sciences (2)
-
- Molecular, Cellular, and Tissue Engineering (2)
- Analytical, Diagnostic and Therapeutic Techniques and Equipment (1)
- Biochemical and Biomolecular Engineering (1)
- Biomedical (1)
- Biomedical Devices and Instrumentation (1)
- Biotechnology (1)
- Cancer Biology (1)
- Cardiology (1)
- Cell Biology (1)
- Cell and Developmental Biology (1)
- Chemical Engineering (1)
- Developmental Biology (1)
- Electrical and Computer Engineering (1)
- Endocrinology, Diabetes, and Metabolism (1)
- Engineering Science and Materials (1)
- Gastroenterology (1)
- Life Sciences (1)
- Medical Specialties (1)
- Optics (1)
- Other Engineering Science and Materials (1)
- Other Mechanical Engineering (1)
- Pediatrics (1)
- Keyword
-
- Multi-magnetic coils (2)
- Novel TMS coils (2)
- Rat stimulation (2)
- Transcranial Magnetic Stimulation (TMS) (2)
- 3D Live-FRET imaging (1)
-
- Actomyosin contractility (1)
- Algorithm (1)
- Aortic Hemodynamics and Wall Shear Stress (1)
- Automated (1)
- Bariatric Surgery (1)
- Biomedical Engineering (1)
- Biophysics (1)
- Cardiac (1)
- Cardiology (1)
- Convolutional Neural Networks (1)
- Cornea (1)
- Deep Encoder-Decoder Networks (1)
- Desmosomes (1)
- Devices (1)
- E-cadherin (1)
- Epithelial to Mesenchymal Transition (1)
- FRET standard (1)
- Feature Recognition (1)
- Femtosecond Laser (1)
- Fibrosis (1)
- Harmonic Generation (1)
- Hip (1)
- Image Processing (1)
- Image Segmentation (1)
- Induced Electric Field in the Brain (1)
- Publication Type
Articles 1 - 8 of 8
Full-Text Articles in Bioimaging and Biomedical Optics
Multi-Magnetic Material Transcranial Magnetic Stimulation Coils Development And Electric Field Measurement & Modeling Using Machine Learning, Mohannad Tashli
Multi-Magnetic Material Transcranial Magnetic Stimulation Coils Development And Electric Field Measurement & Modeling Using Machine Learning, Mohannad Tashli
Theses and Dissertations
Transcranial Magnetic Stimulation (TMS) is a safe, effective, and non-invasive therapy for treating several psychiatric and neurological disorders. TMS is Food and Drug Administration (FDA) approved treatment and is commonly applied to patients who do not respond to medications for the treatment of clinical depression, smoking cessation, obsessive-compulsive disorder and migraine. Recently, there has been an increase in the development of electromagnetic neuromodulation techniques targeted at enhancing the effectiveness of TMS devices for the treatment of mental diseases. In TMS stimulation, focality is an important factor which determines the specificity of the pulses induced in different brain tissues. The electromagnetic …
Advanced Modeling And Innovative Transcranial Magnetic Stimulation Coil Designs For The Treatment Of Neurological Disorders, Mohannad Tashli
Advanced Modeling And Innovative Transcranial Magnetic Stimulation Coil Designs For The Treatment Of Neurological Disorders, Mohannad Tashli
Theses and Dissertations
Transcranial magnetic stimulation (TMS) is a safe, effective and non-invasive treatment for several mental and psychiatric disorders. TMS is an FDA approved treatment and is commonly applied to patients who do not respond to medications for the treatment of clinical depression, smoking cessation, obsessive-compulsive disorder and migraine. Recently, there has been an increase in the development of electromagnetic neuromodulation techniques targeted at enhancing the effectiveness of TMS devices for the treatment of mental diseases. In TMS stimulation, focality is an important factor which determines the specificity of the pulses induced in different brain tissues. The electromagnetic pulses must be confined …
Patient-Specific Analysis Of Aortic Hemodynamics And Wall Shear Stresses In Patients Undergoing Pediatric Bariatric Surgery Using 2d Phase-Contrast Mri, Oluwaferanmi S. Akande, Joao Soares, Nathan Hargan, Dr. Uyen Truong, Haeung Kang, David Lanning
Patient-Specific Analysis Of Aortic Hemodynamics And Wall Shear Stresses In Patients Undergoing Pediatric Bariatric Surgery Using 2d Phase-Contrast Mri, Oluwaferanmi S. Akande, Joao Soares, Nathan Hargan, Dr. Uyen Truong, Haeung Kang, David Lanning
Undergraduate Research Posters
Patient-Specific Analysis of Aortic Hemodynamics and Wall Shear Stresses in Patients Undergoing Pediatric Bariatric Surgery using 2D Phase-Contrast MRI
Feranmi Akande1 Nathan Hargan2 Haesung Kang3 David Lanning3 Uyen Truong4 João S. Soares1
1 Department of Biomedical Engineering, College of Engineering, Virginia Commonwealth University
2 Department of Mechanical & Nuclear Engineering, College of Engineering, Virginia Commonwealth University
3 Department of Cardiology, Children’s Hospital of Richmond, Virginia Commonwealth University
Introduction: Severe obesity among today’s youth is a rising epidemic within the United States. Emerging research has linked childhood obesity with shortened life expectancy and early …
Imaging Potential In Saturation Recovery Methods For Sarcoidosis Patients With Medical Devices, Samantha Zhao
Imaging Potential In Saturation Recovery Methods For Sarcoidosis Patients With Medical Devices, Samantha Zhao
Theses and Dissertations
Cardiovascular magnetic resonance (CMR) imaging is a preferred imaging methodology due to its lack of ionizing radiation and ability to detect myocardial inflammation and fibrosis using quantitative T1 mapping techniques. Cardiac sarcoidosis (CS) is characterized as the formation of granulomas in the myocardium. Current methods for detection include measuring non-cardiac specific C-reactive protein (CRP) levels, or PET imaging, which uses ionizing radiation, therefore CMR would make an ideal imaging option. However, many CS patients have implanted cardiac devices which can cause degradation in image. The modified Look-Locker inversion recovery (MOLLI) method is widely used in quantitative T1 mapping with high …
Higher Tensile Forces Across Cellular Junctions And An Intact Nuclear Linc Complex Is Required For Epithelial Function And Stability, Fnu Vani Narayanan
Higher Tensile Forces Across Cellular Junctions And An Intact Nuclear Linc Complex Is Required For Epithelial Function And Stability, Fnu Vani Narayanan
Theses and Dissertations
Recent advances in three-dimensional (3D) cell culture systems have provided key insights into the understanding of biochemical and physiological states of native tissue. A significant progress in the field of mechanobiology involves measuring cellular traction forces in a more native 3D environment. However, the effects of mechanical forces exerted across cellular junctions and the nuclear LINC complex, in an organized 3D system has not been investigated thus far. Epithelial cells spontaneously form acini (also known as cysts or spheroids) with a single, fluid-filled central lumen, when grown in 3D matrices. The size of the lumen is dependent on apical secretion …
Automatic Hip Analysis Suite, Nathan J. Veilleux
Automatic Hip Analysis Suite, Nathan J. Veilleux
Theses and Dissertations
Image recognition and computer vision are becoming increasingly useful for diagnostic and surgical planning purposes. Analyses of patient morphology can be performed much more quickly and reliably with algorithmic assistance. Traditional measurements of the hip involve visual inspection of patient radiographs or hand calculation with software assistance. In the most extreme cases, estimates of bone orientation are made via palpation of a patient’s hip. There is the possibility for significant improvements in reliability if measurements can be made in the absence of human interpretation. As many of these techniques require CT scans as a prerequisite, all of the necessary information …
Development And Validation Of A Novel Resonant Energy Transfer (Fret) Biosensor To Measure Tensile Forces At The Linc Complex In Live Cells, Paul Arsenovic
Development And Validation Of A Novel Resonant Energy Transfer (Fret) Biosensor To Measure Tensile Forces At The Linc Complex In Live Cells, Paul Arsenovic
Theses and Dissertations
There is a large body of evidence supporting the theory that cell physiology largely depends on the mechanical properties of its surroundings or micro-environment. More recently studies have shown that changes to intra-cellular mechanical properties can also have a meaningful impact on cell function and in some cases lead to the progression of ailments or disease. For example, small changes to the protein sequence of a structural nuclear envelope protein called lamin-A is known to cause a variety of neurological and musculoskeletal diseases referred to as laminopathies. Currently, there is little incite into how these mutations lead to disease progression …
Femtosecond Laser Beam Propagation Through Corneal Tissue: Evaluation Of Therapeutic Laser-Stimulated Second And Third-Harmonic Generation, William R. Calhoun Iii
Femtosecond Laser Beam Propagation Through Corneal Tissue: Evaluation Of Therapeutic Laser-Stimulated Second And Third-Harmonic Generation, William R. Calhoun Iii
Theses and Dissertations
One of the most recent advancements in laser technology is the development of ultrashort pulsed femtosecond lasers (FSLs). FSLs are improving many fields due to their unique extreme precision, low energy and ablation characteristics. In the area of laser medicine, ophthalmic surgeries have seen very promising developments. Some of the most commonly performed surgical operations in the world, including laser-assisted in-situ keratomileusis (LASIK), lens replacement (cataract surgery), and keratoplasty (cornea transplant), now employ FSLs for their unique abilities that lead to improved clinical outcome and patient satisfaction.
The application of FSLs in medical therapeutics is a recent development, and although …