Robust Dynamic Balance Of Ap-1 Transcription Factors In A Neuronal Gene Regulatory Network.,
2010
Thomas Jefferson University
Robust Dynamic Balance Of Ap-1 Transcription Factors In A Neuronal Gene Regulatory Network., Gregory M Miller, Babatunde A Ogunnaike, James S Schwaber, Rajanikanth Vadigepalli
Department of Pathology, Anatomy, and Cell Biology Faculty Papers
BACKGROUND: The octapeptide Angiotensin II is a key hormone that acts via its receptor AT1R in the brainstem to modulate the blood pressure control circuits and thus plays a central role in the cardiac and respiratory homeostasis. This modulation occurs via activation of a complex network of signaling proteins and transcription factors, leading to changes in levels of key genes and proteins. AT1R initiated activity in the nucleus tractus solitarius (NTS), which regulates blood pressure, has been the subject of extensive molecular analysis. But the adaptive network interactions in the NTS response to AT1R, plausibly related to the development of …
Integration Mechanisms For Heading Perception,
2010
Boston University
Integration Mechanisms For Heading Perception, Elif M. Sikoglu, Finnegan J. Calabro, Scott A. Beardsley, Lucia M. Vaina
Biomedical Engineering Faculty Research and Publications
Previous studies of heading perception suggest that human observers employ spatiotemporal pooling to accommodate noise in optic flow stimuli. Here, we investigated how spatial and temporal integration mechanisms are used for judgments of heading through a psychophysical experiment involving three different types of noise. Furthermore, we developed two ideal observer models to study the components of the spatial information used by observers when performing the heading task. In the psychophysical experiment, we applied three types of direction noise to optic flow stimuli to differentiate the involvement of spatial and temporal integration mechanisms. The results indicate that temporal integration mechanisms play …
The Effect Of Abductor Muscle And Anterior-Posterior Hip Contact Load Simulation On The In-Vitro Primary Stability Of A Cementless Hip Stem,
2010
Korean Advanced Institute of Science and Technology
The Effect Of Abductor Muscle And Anterior-Posterior Hip Contact Load Simulation On The In-Vitro Primary Stability Of A Cementless Hip Stem, Youngbae Park, Carolyne Albert, Yong-San Yoon, Göran Fernlund, Hanspeter Frei, Thomas R. Oxland
Biomedical Engineering Faculty Research and Publications
Background
In-vitro mechanical tests are commonly performed to assess pre-clinically the effect of implant design on the stability of hip endoprostheses. There is no standard protocol for these tests, and the forces applied vary between studies. This study examines the effect of the abductor force with and without application of the anterior-posterior hip contact force in the in-vitro assessment of cementless hip implant stability.
Methods
Cementless stems (VerSys Fiber Metal) were implanted in twelve composite femurs which were divided into two groups: group 1 (N = 6) was loaded with the hip contact force only, whereas group 2 (N = …