Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons™

Open Access. Powered by Scholars. Published by Universities.®

11,560 Full-Text Articles 22,708 Authors 5,788,939 Downloads 212 Institutions

All Articles in Biomedical Engineering and Bioengineering

Faceted Search

11,560 full-text articles. Page 324 of 476.

Design And Analysis Of A Lift Assist Walker, Deep P. Shah 2016 California Polytechnic State University, San Luis Obispo

Design And Analysis Of A Lift Assist Walker, Deep P. Shah

Master's Theses

Walkers provided stability to the elderly but cannot assist a person from sitting to standing. The objective of this project is to present the design and analysis of a lift assist walker. This report discusses the design and analysis of a collapsible lift assist walker capable of lifting a patient up to 250 lbs. from seated to standing in under 10 seconds. The designed walker utilized a two stage scissor mechanism with a gas spring assisted embedded linear actuator.


Fluid Flow Characterization In Rapid Prototyped Common Iliac Artery Aneurysm Molds, Daniel Cole Greinke 2016 California Polytechnic State University, San Luis Obispo

Fluid Flow Characterization In Rapid Prototyped Common Iliac Artery Aneurysm Molds, Daniel Cole Greinke

Master's Theses

The goal of this project was to determine whether i) fused deposition modeling could be employed to manufacture molds for vascular constructs, ii) whether vascular constructs could be created from these molds, and iii) to verify practical equivalence between observed fluid velocities. Dye tracking was to be employed to characterize fluid velocity profiles through the in vitro vascular constructs, including a half-vessel model and a full vessel model of an iliac artery aneurysm. A PDMS half-vessel construct was manufactured, and the movement of dye through the construct was tracked by a cellphone camera. Thresholds were applied to each video in …


Faculty Intellectual Property In Capstone Design Projects, Jay R. Goldberg 2016 Marquette University

Faculty Intellectual Property In Capstone Design Projects, Jay R. Goldberg

Biomedical Engineering Faculty Research and Publications

Reports on the Capstone Design challenge, focusing on design challenges for the participants. By focusing on the design process and allowing students to gain hands-on experience in design, they help prepare students for careers in engineering. In many capstone design courses, students design a product or device to solve a problem and build and test a prototype to verify and validate the design. Student teams are often advised by some combination of industry sponsors, clinical advisors, and/or faculty advisors. Faculty advisors serve as technical advisors to the teams and provide guidance to keep them on track. They are not members …


Instrumented Lumbar Corpectomy And Spinal Reconstruction Comparing Rhbmp-2/Compression-Resistant Matrix, Rhbmp-2/Absorbable Collagen Sponge/Ceramic Granules Mixture, And Autograft In Two Different Devices: A Study In Sheep, Jeffrey M. Toth, David G. Schwartz, Jean-Piere Mobasser, Joseph Williams 2016 Marquette University

Instrumented Lumbar Corpectomy And Spinal Reconstruction Comparing Rhbmp-2/Compression-Resistant Matrix, Rhbmp-2/Absorbable Collagen Sponge/Ceramic Granules Mixture, And Autograft In Two Different Devices: A Study In Sheep, Jeffrey M. Toth, David G. Schwartz, Jean-Piere Mobasser, Joseph Williams

Biomedical Engineering Faculty Research and Publications

Study Design. Fusion success with rhBMP-2 and autograft in titanium or PEEK corpectomy devices was evaluated in a sheep lumbar corpectomy model. The 6 treatment groups included titanium mesh or PEEK corpectomy devices filled with rhBMP-2 on a compression-resistant matrix (CRM) carrier; rhBMP-2 in a morselized absorbable collagen sponge (ACS) carrier combined with resorbable ceramic granules; and autograft.

Objective. The aim of this study was to determine fusion rates associated with 2 different preparations of rhBMP-2 as well as autograft in an instrumented ovine lumbar corpectomy model 6 months postoperatively.

Summary of Background Data. Vertebral reconstruction with corpectomy devices requires …


Foot Strike Patterns And Body Alignment Effects On Muscle Activity During Running., Nicole Knapp 2016 University of Louisville

Foot Strike Patterns And Body Alignment Effects On Muscle Activity During Running., Nicole Knapp

Electronic Theses and Dissertations

The mechanics of the running stride was altered around the 1970s when shoes were released with an elevated heel (McDougall 2009). At this point in time a heel strike running style became increasingly common and has remained the popular pattern when running in traditional shoes. In fact, the exact same person has been seen to alter their stride when running in a traditional shoe where they heel strike verses barefoot where they take on a forefoot strike (Lieberman 2010).

When an individual heel strikes, the ground reaction force is greater and contains an initial peak which is void in a …


Mri Signal Intensity Differentiation Of Brainstem Encephalitis Induced By Enterovirus 71: A Classification Approach For Acute And Convalescence Stages, Hongwu Zeng, Wenxian Huang, Feiqiu Wen, Yonker Wang, Yungen Gan, Weibin Zeng, Ranran Chen, Yanxia He, Zaiyi Liu, Changhong Liang, Kelvin K. L. Wong 2016 Southern Medical University, China

Mri Signal Intensity Differentiation Of Brainstem Encephalitis Induced By Enterovirus 71: A Classification Approach For Acute And Convalescence Stages, Hongwu Zeng, Wenxian Huang, Feiqiu Wen, Yonker Wang, Yungen Gan, Weibin Zeng, Ranran Chen, Yanxia He, Zaiyi Liu, Changhong Liang, Kelvin K. L. Wong

Radiology Faculty Publications

Background: The objective of this study is to assess standardized histograms of signal intensities of T1 signal and T2 signal on sagittal view without enhancement during (1) acute stage, and (2) convalescence stage of pediatric patients with Enterovirus 71 related brainstem encephalitis (BE), and with respect to (3) healthy normal.

Methods: Our subjects were hospitalized between March 2010 and October 2012, and underwent pre- and post-contrast MRI studies. The research question to be answered is whether the comparison of the MRI image intensity histograms and relevant statistical quantification can add new knowledge to the diagnosis of BE patients. So, both …


Usu Biological Engineer Patents Method To Make Natural Blue Dye | College Of Engineering, USU College of Engineering 2016 Utah State University

Usu Biological Engineer Patents Method To Make Natural Blue Dye | College Of Engineering, Usu College Of Engineering

College of Engineering News

Feb. 22, 2016 – A Utah State University researcher has taken a big step toward making a safer, more natural dye that can be used in the food, textile, cosmetic and other industries.

Dr. Jixun Zhan, an associate professor of biological engineering at USU, has secured a patent for an innovative method to produce the deep blue dye known as indigoidine. The tint was originally synthesized from a bacterial strain found inRhode Island and offered a promising alternative to the synthetic dyes used to color jeans, leather, food and paper.


Segway: A Simple Framework For Unsupervised Sleep Segmentation In Experimental Eeg Recordings, Farid Yaghouby, Sridhar Sunderam 2016 University of Kentucky

Segway: A Simple Framework For Unsupervised Sleep Segmentation In Experimental Eeg Recordings, Farid Yaghouby, Sridhar Sunderam

Biomedical Engineering Faculty Publications

Sleep analysis in animal models typically involves recording an electroencephalogram (EEG) and electromyogram (EMG) and scoring vigilance state in brief epochs of data as Wake, REM (rapid eye movement sleep) or NREM (non-REM) either manually or using a computer algorithm. Computerized methods usually estimate features from each epoch like the spectral power associated with distinctive cortical rhythms and dissect the feature space into regions associated with different states by applying thresholds, or by using supervised/unsupervised statistical classifiers; but there are some factors to consider when using them:

  • Most classifiers require scored sample data, elaborate heuristics or computational steps not easily …


Ryan Summers Seminar Presentation | Biological Engineering, USU College of Engineering 2016 Utah State University

Ryan Summers Seminar Presentation | Biological Engineering, Usu College Of Engineering

College of Engineering News

Upcoming Seminar:

"Production of High-Value Methylxanthines by Metabolically Engineering E. coli."

ENGR 406

Friday: 2/19/16

12:00 - 1:00 PM

Presented by BE Alumni of the Year 2016, Dr. Ryan Summers.


Quantitative Analysis Of Retrieved Glenoid Liners, Katelyn Childs, Lynn Crosby, Tarun Goswami 2016 Wright State University - Main Campus

Quantitative Analysis Of Retrieved Glenoid Liners, Katelyn Childs, Lynn Crosby, Tarun Goswami

Biomedical, Industrial & Human Factors Engineering Faculty Publications

Revision of orthopedic surgeries is often expensive and involves higher risk from complications. Since most total joint replacement devices use a polyethylene bearing, which serves as a weak link, the assessment of damage to the liner due to in vivo exposure is very important. The failures often are due to excessive polyethylene wear. The glenoid liners are complex and hemispherical in shape and present challenges while assessing the damage. Therefore, the study on the analysis of glenoid liners retrieved from revision surgery may lend insight into common wear patterns and improve future product designs. The purpose of this pilot study …


Equilibrium Testing Of Rat Tail Tendon: An Analysis Of The Viscoelastic Properties Of Collagen Under Different Strain Points, Joshua C. Witt 2016 Rose-Hulman Institute of Technology

Equilibrium Testing Of Rat Tail Tendon: An Analysis Of The Viscoelastic Properties Of Collagen Under Different Strain Points, Joshua C. Witt

Graduate Theses - Biology & Biomedical Engineering

Instantaneous tensile testing and stress-relaxation testing are forms of mechanical testing used to determine the elastic and viscoelastic properties of biological tissue. Equilibrium testing is a form of testing that combines both of these testing approaches at different strain points to determine the elastic properties of a material and also assess their viscoelastic properties in the same test. This testing method is commonly used on highly viscoelastic materials such as cartilage but has never been fully described in dense collagenous materials such as tendon or ligament. This analysis utilizes different strain points selected to capture the classic non-linear behavior of …


Long-Term Velaglucerase Alfa Treatment In Children With Gaucher Disease Type 1 Naïve To Enzyme Replacement Therapy Or Previously Treated With Imiglucerase, Laurie Smith, William Rhead, Joel Charrow, Suma P. Shankar, Ashish Bavdekar, Nicola Longo, Rebecca Mardach, Paul Harmatz, Thomas N. Hangartner, Hak-Myung Lee, Eric Crombez, Gregory M. Pastores 2016 Wright State University - Main Campus

Long-Term Velaglucerase Alfa Treatment In Children With Gaucher Disease Type 1 Naïve To Enzyme Replacement Therapy Or Previously Treated With Imiglucerase, Laurie Smith, William Rhead, Joel Charrow, Suma P. Shankar, Ashish Bavdekar, Nicola Longo, Rebecca Mardach, Paul Harmatz, Thomas N. Hangartner, Hak-Myung Lee, Eric Crombez, Gregory M. Pastores

Biomedical, Industrial & Human Factors Engineering Faculty Publications

Background

Gaucher Disease type 1 (GD1) often manifests in childhood. Early treatment with enzyme replacement therapy (ERT) may prevent disease complications. We report the assessment of velaglucerase alfa ERT in pediatric GD1 patients who participated in a long-term extension study (HGT-GCB-044, ClinicalTrials.gov Identifier NCT00635427).

Methods

Safety and efficacy were evaluated in pediatric patients receiving velaglucerase alfa 30–60 U/kg by intravenous infusion every other week. In addition to key hematological and visceral efficacy assessments, exploratory assessments conducted specifically in pediatric patients included evaluation of height, bone age, bone marrow burden, and Tanner stage of puberty.

Results

The study included 24 …


Introduction To Biomedical Engineering, Maribel Vazquez 2016 CUNY City College

Introduction To Biomedical Engineering, Maribel Vazquez

Open Educational Resources

An overview of the field of biomedical engineering designed to acquaint the students with its interdisciplinary nature; research areas presented by the biomedical engineering faculty.


Supervised Learning-Based Explicit Nonlinear Model Predictive Control And Unknown Input Estimation In Biomedical Systems, Ankush Chakrabarty 2016 Purdue University

Supervised Learning-Based Explicit Nonlinear Model Predictive Control And Unknown Input Estimation In Biomedical Systems, Ankush Chakrabarty

Open Access Dissertations

Application of nonlinear control theory to biomedical systems involves tackling some unique and challenging problems. The mathematical models that describe biomedical systems are typically large and nonlinear. In addition, biological systems exhibit dynamics which are not reflected in the model (so-called 'un-modeled dynamics') and hard constraints on the states and control actions, which exacerbate the difficulties in designing model-based controllers or observers.

This thesis investigates the design of scalable fast explicit nonlinear model predictive controllers (ENMPCs). The design involves (i) the estimation of a feasible region using Lyapunov stability methods and support vector machines; and (ii) within the estimated feasible …


Effects Of Intraframe Distortion On Measures Of Cone Mosaic Geometry From Adaptive Optics Scanning Light Ophthalmoscopy, Robert F. Cooper, Yusufu N. Sulai, Adam M. Dubis, Toco Y.P. Chui, Richard B. Rosen, Michel Michaelides, Alfredo Dubra, Joseph Carroll 2016 Marquette University

Effects Of Intraframe Distortion On Measures Of Cone Mosaic Geometry From Adaptive Optics Scanning Light Ophthalmoscopy, Robert F. Cooper, Yusufu N. Sulai, Adam M. Dubis, Toco Y.P. Chui, Richard B. Rosen, Michel Michaelides, Alfredo Dubra, Joseph Carroll

Biomedical Engineering Faculty Research and Publications

Purpose: To characterize the effects of intraframe distortion due to involuntary eye motion on measures of cone mosaic geometry derived from adaptive optics scanning light ophthalmoscope (AOSLO) images.

Methods: We acquired AOSLO image sequences from 20 subjects at 1.0, 2.0, and 5.08 temporal from fixation. An expert grader manually selected 10 minimally distorted reference frames from each 150-frame sequence for subsequent registration. Cone mosaic geometry was measured in all registered images (n ¼ 600) using multiple metrics, and the repeatability of these metrics was used to assess the impact of the distortions from each reference frame. In nine additional subjects, …


Characterization Of Silica-Based And Borate-Based, Titanium-Containing Bioactive Glasses For Coating Metallic Implants, Omar Rodriguez, Declan J. Curran, Marcello Papini, Lana M. Placek, Anthony W. Wren, Emil H. Schemitsch, Paul Zalzal, Mark R. Towler 2016 Missouri University of Science and Technology

Characterization Of Silica-Based And Borate-Based, Titanium-Containing Bioactive Glasses For Coating Metallic Implants, Omar Rodriguez, Declan J. Curran, Marcello Papini, Lana M. Placek, Anthony W. Wren, Emil H. Schemitsch, Paul Zalzal, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

Bioactive glasses have found applications in diverse fields, including orthopedics and dentistry, where they have been utilized for the fixation of bone and teeth and as scaffolds for drug delivery. The present work outlines the characterization of two novel titanium-containing glass series, one silica-based and one borate-based. For the silica-based series, titanium is added at the expense of silicon dioxide whereas for the borate-based series, it is added at the expense of boron oxide as confirmed by Energy Dispersive Spectroscopy. Amorphous structures are obtained for silica-based glass at 15 mol% TiO2 and for borate-based glasses at 0 mol% and …


Effect Of Temporal Onset Of Mechanical Loading On Tendon To Bone Healing, Determined With A Novel In-Vivo Device, Mark E. Stasiak 2016 CUNY Graduate Center

Effect Of Temporal Onset Of Mechanical Loading On Tendon To Bone Healing, Determined With A Novel In-Vivo Device, Mark E. Stasiak

Dissertations, Theses, and Capstone Projects

Background: Exposure to tensile loading has been shown to maintain tendon/ligament homeostasis, with the tensile modulus of the tissue increasing in response to greater loading frequency, and even decreasing in the absence of load. However after injury or surgical repair the effect of tensile load is controversial, with many studies implicating mechanical loading with impaired healing. It is currently unknown when the tensile loading imparted during rehabilitation exercise, can be safely reintroduced after surgical tendon repair or ligament reconstruction, and at what time point it can most benefit the remodeling process. To investigate the effect of tensile loading protocols on …


A Study Of Kinematics And Kinetics In Time-Constrained Arm Movements, Oyindamola Owoeye 2016 New Jersey Institute of Technology

A Study Of Kinematics And Kinetics In Time-Constrained Arm Movements, Oyindamola Owoeye

Theses

Several studies such as the equilibrium point hypothesis (EPH) purport that the motor signals that descend from the brain instead of encoding muscle torques, influence an existing relationship between muscle torque and body configuration.

In the present study, the possibility of torque depending explicitly on position was tested using a task in which subjects (N=5) moved a simulated weightless frictionless mass through a small (<8 degree) elbow extension in order to move a cursor on a screen to a target location. Each subject completed 720 trials. On ~10% of trials the simulated mass was increased unknown to the subject. The relationship between the cursor’s position and the torque applied to the system was held constant even when the simulated mass was increased. Thus, any change in torque produced was neither due the subjects’ perception of the mass nor due to their perception of the cursor. The time at which the subjects torque changed direction was seen to be significantly different (p<0.005) during trials which the mass changed. This change in torque is concluded to be position-dependent. However the possibility of this being a merely mechanical effect could not be ruled out by due to poor EMG collection.

A post-hoc analysis of different position-dependent motor control models, was done. Particularly, an exponential spring model, a linear spring model, and a linear spring with relative damping model were each tested to see how well …


Comparison Of Muscle Synergies Elicited From Transcranial Meganetic Stimulation (Tms) And Voluntary Movements, Yifei Wei 2016 New Jersey Institute of Technology

Comparison Of Muscle Synergies Elicited From Transcranial Meganetic Stimulation (Tms) And Voluntary Movements, Yifei Wei

Theses

A key question in motor control is the redundancy of musculoskeletal elements involved. This problem refers to as the degree of freedom problem. The Muscle Synergy Hypothesis is one of the hypotheses that aim to resolve the problem which defines that a muscle synergy is a combination of a small set of muscles activated at different levels, serving as a building block that constructs motor behaviors. A recent study (Overduin et al. 2012) demonstrated that muscle synergies decomposed by Nonnegative Matrix Factorization (NMF) from EMG patterns evoked by intra-cortical microsimulation (ICMS) in the monkey remarkably matched ones observed in naturalistic …


Rodent Testing Device Surrogate For Shockwave Blast Testing, Anthony C. Misistia 2016 New Jersey Institute of Technology

Rodent Testing Device Surrogate For Shockwave Blast Testing, Anthony C. Misistia

Theses

Many laboratories around the world are conduct shockwave blast injury tests on rodents to simulate blast traumatic brain injury (TBI). Each of these laboratories has different techniques for creating the shockwave blasts as well as positioning the rats. There is no device to determine whether or not the rodent animal models actually experiences a true blast wave in a given set up. This device was developed as a method for verifying rodents undergoing true shockwave blasts through biometrics, instrumentation and the basic biomechanical responses a rodent experiences during such tests. Since the goal of shockwave blast testing is to replicate …


Digital Commons powered by bepress