Biocompatibility Of Cao-Na2o-Sio2/Tio2 Glass Ceramic Scaffolds For Orthopaedic Applications,
2013
Missouri University of Science and Technology
Biocompatibility Of Cao-Na2o-Sio2/Tio2 Glass Ceramic Scaffolds For Orthopaedic Applications, A. W. Wren, A. Coughlan, K. E. Smale, S. T. Misture, B. P. Mahon, O. M. Clarkin, Mark R. Towler
Chemical and Biochemical Engineering Faculty Research & Creative Works
This work aims to determine the effect of substituting TiO2 for SiO2 in a 0.62SiO2-Na2O-0.24CaO based glass-ceramic scaffold. High temperature X-ray Diffraction (HT-XRD) was used to determine the sintering temperature (700oC). Both optical microscopy and x-ray micotomography was used to determine the average pore size (540-680ìm) of each scaffold. Cytocompatibility of each scaffold was conducted using murine mesenchymal stem cells. © 2013 IEEE.
Wireless Myoelectric Sensor Minimization And Packaging,
2013
University of Iceland
Wireless Myoelectric Sensor Minimization And Packaging, Ásbjörg Einarsdóttir, Pedro Irazoqui Dr.
The Summer Undergraduate Research Fellowship (SURF) Symposium
Many people suffer from amputation, which affects their lives severely by disabling them from doing chores in their daily life as well as chores related to work and leisure. For the last years, prosthetics’ development has been fast and the devices that are being used now are a miracle compared to what has been used before. But still, the battle is not over yet. Although scientists have techniques and devices to use nerve residues from the amputated limb to control the prosthetic, smaller devices that can detect the signals from those nerves better need to be developed. In this research …
A Quantitative Analysis Of A Paper-Based, Laser-Defined, Oxygen-Generating Platform For Chronic Wounds,
2013
Rice University
A Quantitative Analysis Of A Paper-Based, Laser-Defined, Oxygen-Generating Platform For Chronic Wounds, Tiffany L. Huang, Babak Ziaie
The Summer Undergraduate Research Fellowship (SURF) Symposium
Chronic wounds affect 6.5 million patients a year while consuming US$25 billion in health care costs (Sen 2009 Wound Repair Regen.). Despite advances in wound management therapies, modern treatment for chronic wounds still requires continual professional attention and expensive equipment, posing serious practical and financial burdens for the regular patient. To provide an alternative solution, we are developing a low-cost smart bandage platform that integrates actuators and sensors to monitor and treat chronic wounds. One component of the integrated platform is an oxygen-generating module. It is a polydimethylsiloxane (PDMS) based microfluidic device fabricated on a parchment paper substrate that …
Dynamic Balance Control During Treadmill Walking In Chronic Stroke Survivors,
2013
Marquette University
Dynamic Balance Control During Treadmill Walking In Chronic Stroke Survivors, Eric Richard Walker
Dissertations (1934 -)
Maintaining dynamic balance is an important component of walking function that is likely impaired in chronic stroke survivors, evidenced by an increased prevalence of falls. Dynamic balance control requires maintaining the center of mass (COM) within the base of support during movement. During walking, dynamic balance control is achieved largely by modifying foot placement to adjust the base of support. However, chronic stroke survivors have difficulty with both precision control of foot placement, as well as reduced control of COM movement. The objective of this dissertation was to characterize dynamic balance control strategies during walking in chronic stroke survivors. Additionally, …
Supraspinal Control Of Unilateral Locomotor Performance: An Fmri Study Using A Custom Pedaling Device,
2013
Marquette University
Supraspinal Control Of Unilateral Locomotor Performance: An Fmri Study Using A Custom Pedaling Device, Brett Arand
Master's Theses (2009 -)
This study aimed to develop a novel unilateral pedaling device, validate its function, and use it in an fMRI study of bilateral vs. unilateral locomotor control. The new device is MRI compatible and allows for conventional coupled bilateral pedaling, along with decoupled unilateral pedaling. It was designed with an assistance mechanism to simulate the presence of the non-contributing leg while pedaling unilaterally. During coupled bilateral pedaling, the two legs work in unison: while one leg is extending in the downstroke, it provides support to lift the other leg back up as it is flexing in the upstroke. The device uses …
Force Sensing Surgical Scissor Blades Using Fibre Bragg Grating Sensors,
2013
Technological University Dublin
Force Sensing Surgical Scissor Blades Using Fibre Bragg Grating Sensors, Dean Callaghan
Doctoral
This thesis considers the development and analysis of unique sensorised surgical scissor blades for application in minimally invasive robotic surgery (MIRS). The lack of haptic (force and tactile) feedback to the user is currently an unresolved issue with modern MIRS systems. This thesis presents details on smart sensing scissor blades which enable the measurement of instrument-tissue interaction forces for the purpose of force reflection and tissue property identification. A review of current literature established that there exists a need for small compact, biocompatible, sterilisable and robust sensors which meet the demands of current MIRS instruments. Therefore, the sensorised blades exploit …
Comparison Of A Sio2-Cao-Zno-Sro Glass Polyalkenoate Cement To Commercial Dental Materials: Ion Release, Biocompatibility And Antibacterial Properties,
2013
Missouri University of Science and Technology
Comparison Of A Sio2-Cao-Zno-Sro Glass Polyalkenoate Cement To Commercial Dental Materials: Ion Release, Biocompatibility And Antibacterial Properties, A. W. Wren, A. Coughlan, M. M. Hall, M. J. German, Mark R. Towler
Chemical and Biochemical Engineering Faculty Research & Creative Works
Ion Release and biocompatibility of a CaO-SrO-ZnO-SiO2 (BT 101) based glass polyalkenoate cement (GPC) was compared against commercial GPCs, Fuji IX and Ketac Molar. The radiopacity (R) was similar for each material, 2.0-2.8. Ion release was evaluated on each material over 1, 7, 30 and 90 days. BT 101 release included Ca (23 mg/L), Sr (23 mg/L) Zn (13 mg/L), Si (203 mg/L). Fuji IX release includes Ca (0.7 mg/L), Al (3 mg/L) Si (26 mg/L), Na (60 mg/L) and P (0.5 mg/L) while Ketac Molar release includes Ca (1 mg/L), Al (0.6 mg/L) Si (23 mg/L), Na (76 …
Design Of A Compliant Underactuated Robotic Finger With Coordinated Stiffness,
2013
University of Nebraska-Lincoln
Design Of A Compliant Underactuated Robotic Finger With Coordinated Stiffness, Etienne Dessauw
Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research
The concept of underactuation has been previously developed in the robotic field for grasping applications. For these anthropomorphic grippers, the minimization of the number of input signals, or in other words underactuation, is the most expected characteristic. This method has become very popular in recent decades. Indeed, by minimizing the number of input signals, it minimizes the complexity of the system’s control and at the same time avoids increased weight and cost. The inconvenience of such a technique is that the design of this type of system remains a difficult task if the behavior of the underactuated set of joints …
Multimodal Wearable Sensors For Human-Machine Interfaces,
2013
Technological University Dublin
Multimodal Wearable Sensors For Human-Machine Interfaces, Mark Nolan
Doctoral
Certain areas of the body, such as the hands, eyes and organs of speech production, provide high-bandwidth information channels from the conscious mind to the outside world. The objective of this research was to develop an innovative wearable sensor device that records signals from these areas more conveniently than has previously been possible, so that they can be harnessed for communication. A novel bioelectrical and biomechanical sensing device, the wearable endogenous biosignal sensor (WEBS), was developed and tested in various communication and clinical measurement applications.
One ground-breaking feature of the WEBS system is that it digitises biopotentials almost …
Method And Apparatus For Electrical Stimulation Of Tissues Using Signals That Minimize The Effects Of Tissue Impedance,
2013
Kettering University
Method And Apparatus For Electrical Stimulation Of Tissues Using Signals That Minimize The Effects Of Tissue Impedance, Jeffrey Hargrove
Mechanical Engineering Patents
A tissue stimulation system that generates an electrical tissue stimulation signal configured to reduce tissue impedance and increase depth of signal penetration. The use of leads is dynamically controlled and altered between conducting biopotential voltages, conducting electrical tissue stimulation signals, and grounding, in response to a computational analysis of biopotential data acquired from a region of tissue to be stimulated.
Surgical Tooling Designed For The Direct Anterior Approach To Total Hip Arthroplasty,
2013
California Polytechnic State University, San Luis Obispo
Surgical Tooling Designed For The Direct Anterior Approach To Total Hip Arthroplasty, Jon-Peter Meckel
Master's Theses
Surgical Tooling Designed for the Direct Anterior Approach to Total Hip Arthroplasty Jon-Peter Meckel
Total hip arthroplasty (THA) is becoming more and more common in the US as people continue to live longer and more active lives. The main reason that a THA is required is due to the “wear and tear” affliction of osteoarthritis, which in the year 2000 had at least 3% of the population over 30 showing symptoms. A revitalized approach to THA is the direct anterior approach, or Smith-Petersen approach, which limits the amount of musculature affected by the surgery and creates a very stable joint …
Materials Education And Research In Art And Design: A New Role For Libraries (Survey Stats),
2013
Rhode Island School of Design
Materials Education And Research In Art And Design: A New Role For Libraries (Survey Stats), Mark Pompelia
Materials Education and Research in Art and Design: A New Role for Libraries
No abstract provided.
Materials Education And Research In Art And Design: A New Role For Libraries (Program Sheet),
2013
Rhode Island School of Design
Materials Education And Research In Art And Design: A New Role For Libraries (Program Sheet), Mark Pompelia
Materials Education and Research in Art and Design: A New Role for Libraries
No abstract provided.
Materials Education And Research In Art And Design: A New Role For Libraries (Program Booklet),
2013
Rhode Island School of Design
Materials Education And Research In Art And Design: A New Role For Libraries (Program Booklet), Mark Pompelia
Materials Education and Research in Art and Design: A New Role for Libraries
No abstract provided.
Materials Education And Research In Art And Design: A New Role For Libraries (Website),
2013
Rhode Island School of Design
Materials Education And Research In Art And Design: A New Role For Libraries (Website), Mark Pompelia
Materials Education and Research in Art and Design: A New Role for Libraries
No abstract provided.
Materials Collection Creation And Administration: A New Role For Libraries (White Paper),
2013
Rhode Island School of Design
Materials Collection Creation And Administration: A New Role For Libraries (White Paper), Mark Pompelia
Materials Education and Research in Art and Design: A New Role for Libraries
The Problem/Opportunity: To define, identify, and guide design-based materials collections in academic settings and foster community among those with existing collections and/or those considering creating and supporting one.
Contents and topics:
- What is a materials collection?
- Why have a materials collection?
- Acquisition strategies
- Organizational approaches
- Programming possibilities
- Symposium summary
- Resources
The Fabrication & Characterization Of An Electrokinetic Microfluidic Pump From Su-8, A Negative Epoxy-Based Photoresist,
2013
California Polytechnic State University, San Luis Obispo
The Fabrication & Characterization Of An Electrokinetic Microfluidic Pump From Su-8, A Negative Epoxy-Based Photoresist, Nash Anderson
Master's Theses
Microfluidics refers to manipulation, precise control, and behavior of fluids at the micro and nanoliter scales. It has entered the realm of science as a way to precisely measure or mix small amounts of fluid to perform highly controlled reactions. Glass and polydimethylsiloxane (PDMS) are common materials used to create microfluidic devices; however, glass is difficult to process and PDMS is relatively hydrophobic. In this study, SU-8, an epoxy based (negative) photoresist was used to create various electrokinetic microfluidic chips. SU-8 is commonly used in microelectromechanical design. Spin coating of various SU-8 formulations allows for 1 μm to 100 μm …
Evaluation Of Corrosion Properties Of Proprietary Metal Alloy Stents For In-Vivo Use,
2013
California Polytechnic State University - San Luis Obispo
Evaluation Of Corrosion Properties Of Proprietary Metal Alloy Stents For In-Vivo Use, Michael David Bremner
Materials Engineering
To assess corrosion rates of metal alloy bio-absorbable stents an experimental set-up was designed to mimic the coronary artery environment. The artery was modeled using 4mm diameter Tecoflex tubing and the metal alloy stents were inserted into the tubing using a catheter. As is the case in cardiac surgery, the catheter with the stent and a microballoon were maneuvered to the desired position. The microballoon was then slowly inflated to expand the stent and compress it against the tubing walls. The catheter and microballoon were then withdrawn. A circulating pump system was set up to cycle fetal bovine serum (FBS) …
Analysis Of Acetabular Cup Orientation Effects On Stress Shielding In Total Hip Replacements Using Finite Element Methods,
2013
California Polytechnic State University, San Luis Obispo
Analysis Of Acetabular Cup Orientation Effects On Stress Shielding In Total Hip Replacements Using Finite Element Methods, Brogan Mcguire, Jennifer Gemkow, Brad Gausewitz, Alex Georges
Biomedical Engineering
Improper positioning of the acetabular cup has been shown to contribute to issues such as high wear rates and dislocations in total hip replacements. The differences in contact mechanics due to varying orientation of the acetabular cup may also significantly affect strain distribution in the femur. This study examined these effects of acetabular orientation changes and their contribution to stress shielding using finite element analysis. A solid model of a cementless total hip implant was obtained using 3D point scanning and implanted virtually into a femur solid model. The implanted femur model was imported into ABAQUS and loaded with a …
A Mouse Model Of Aortic Endothelial Denudation And Neointimal Formation,
2013
California Polytechnic State University, San Luis Obispo
A Mouse Model Of Aortic Endothelial Denudation And Neointimal Formation, Ashkon C. Nehzati
Biomedical Engineering
More than 385,000 people die from coronary heart disease (CHD) annually and treatment costs $108.9 billion each year including the cost of health care services, medications, and lost productivity. CHD decreases heart function by limiting oxygen and nutrient transport carried through the coronary arteries. A complete block to the coronary arteries causes a myocardial infarction in response to an elimination of blood supply to cardiomyocytes. Partial occlusion results in insufficient blood supply to cardiomyocytes, producing myocardial ischemia and angina, which are usually treated with intravascular stents deployed percutaneously, before myocardial infarction occurs. Stents are the most common ways to expand …