Open Access. Powered by Scholars. Published by Universities.®

Biomechanics and Biotransport Commons

Open Access. Powered by Scholars. Published by Universities.®

583 Full-Text Articles 1,045 Authors 302,252 Downloads 81 Institutions

All Articles in Biomechanics and Biotransport

Faceted Search

583 full-text articles. Page 26 of 28.

Physiological Fluid Specific Agglomeration Patterns Diminish Gold Nanorod Photothermal Characteristics, Kristen K. Comfort, Jared W. Speltz, Bradley M. Stacy, Larry R. Dosser, Saber M. Hussain 2013 University of Dayton

Physiological Fluid Specific Agglomeration Patterns Diminish Gold Nanorod Photothermal Characteristics, Kristen K. Comfort, Jared W. Speltz, Bradley M. Stacy, Larry R. Dosser, Saber M. Hussain

Chemical and Materials Engineering Faculty Publications

Investigations into the use of gold nanorods (Au-NRs) for biological applications are growing exponentially due to their distinctive physicochemical properties, which make them advantageous over other nanomaterials. Au-NRs are particularly renowned for their plasmonic characteristics, which generate a robust photothermal response when stimulated with light at a wavelength matching their surface plasmon resonance. Numerous reports have explored this nanophotonic phenomenon for temperature driven therapies; however, to date there is a significant knowledge gap pertaining to the kinetic heating profile of Au-NRs within a controlled physiological setting. In the present study, the impact of environmental composition on Au-NR behavior and degree …


Data Workflow In Large Scale Simulations Of Blood Flow In Aneurysms, Paolo Di Achille, Jay D. Humphrey 2013 Yale University

Data Workflow In Large Scale Simulations Of Blood Flow In Aneurysms, Paolo Di Achille, Jay D. Humphrey

Yale Day of Data

Aneurysms are responsibile for significant morbidity and mortality, and there is a need for an increased understanding of all the aspects of the natural history of these lesions. We are currently working to extend our analyses with the goal of creating models of aneurysmal progression that are able to predict rupture risk through the description of the evolving geometry, structure, properties, and loads.

Realization of patient specific models of the blood circulation necessitates a complex computationally and data intensive procedure that starts from the collection of medical images in a clinical setting and encompasses several stages of data processing on …


Design Optimization Of An Above-Knee Prosthesis With Energy Regeneration, Taylor Barto, Holly Warner, Rick Rarick, Dan Simon 2013 Cleveland State University

Design Optimization Of An Above-Knee Prosthesis With Energy Regeneration, Taylor Barto, Holly Warner, Rick Rarick, Dan Simon

Undergraduate Research Posters 2013

Above-knee amputees who use a prosthetic leg typically have to compensate for its shortcomings with unnatural hip motions. This compensation eventually leads to adverse health issues such as arthritis. We propose an active prosthesis to improve performance. The motor in our prosthetic knee allows the patient to move his hip normally, thus reducing the possibility of ancillary health issues. To improve the efficiency of the prosthesis, we use the braking phase of the prosthesis to regenerate energy. By storing energy in a supercapacitor during braking, the prosthesis lasts longer between each charge than it would without regenerative braking. We are …


Towards A More Robust Lower Neck Compressive Injury Tolerance - An Approach Combining Multiple Test Methodologies, Daniel Toomey, King H. Yang, N Yoganadan, F A. Pintar, C A. Van Ee 2013 Wayne State University

Towards A More Robust Lower Neck Compressive Injury Tolerance - An Approach Combining Multiple Test Methodologies, Daniel Toomey, King H. Yang, N Yoganadan, F A. Pintar, C A. Van Ee

Biomedical Engineering Faculty Research Publications

Objective.The compressive tolerance of the cervical spine has traditionally been reported in terms of axial force at failure. Previous studies suggest that axial compressive force at failure is particularly sensitive to the alignment of the cervical vertebra and the end conditions of the test methodology used. The present study was designed to develop a methodology to combine the data of previous experiments into a diverse dataset utilizing multiple test methods to allow for the evaluation of the robustness of current and proposed eccentricity based injury criteria.

Methods. Data was combined from two studies composed of dynamic experiments including whole …


Why Is Ca3 More Vulnerable Than Ca1 In Experimental Models Of Controlled Cortical Impact-Induced Brain Injury?, Haojie Mao, Benjamin S. Elkin, Vinay V. Genthikatti, Barclay Morrison III, King H. Yang 2013 Wayne State University

Why Is Ca3 More Vulnerable Than Ca1 In Experimental Models Of Controlled Cortical Impact-Induced Brain Injury?, Haojie Mao, Benjamin S. Elkin, Vinay V. Genthikatti, Barclay Morrison Iii, King H. Yang

Biomedical Engineering Faculty Research Publications

One interesting finding of controlled cortical impact (CCI) experiments is that the CA3 region of the hippocampus, which is positioned further from the impact than the CA1 region, is reported as being more injured. The current literature has suggested a positive correlation between brain tissue stretch and neuronal cell loss. However, it is counterintuitive to assume that CA3 is stretched more during CCI injury. Recent mechanical studies of the brain have reported on a level of spatial heterogeneity not previously appreciated—the finding that CA1 was significantly stiffer than all other regions tested and that CA3 was one of the most …


Finite Element Models Of The Knee & Hip Joints: Using Opensim To Predict Muscle Forces, Kevin S. Jones, Spencer D. Wangerin, Jeffrey D. Pyle, Stephen M. Klisch, Scott J. Hazelwood 2013 California Polytechnic State University - San Luis Obispo

Finite Element Models Of The Knee & Hip Joints: Using Opensim To Predict Muscle Forces, Kevin S. Jones, Spencer D. Wangerin, Jeffrey D. Pyle, Stephen M. Klisch, Scott J. Hazelwood

STAR Program Research Presentations

Quantitative data of stresses and strains in the cartilage of the knee and hip joints are required to design prostheses and can be used to give accurate advice to patients with cartilage damage as to which activities should be avoided. Instrumented hip implants can only give the overall resultant force in the joint, not the stresses and strains throughout the cartilage. Finite Element (FE) models of the Knee and Hip are being constructed in order to obtain the stresses and strains in articular (of the joint) cartilage. Muscle forces and joint contact forces are required as inputs to these FE …


Design Of A Compliant Underactuated Robotic Finger With Coordinated Stiffness, Etienne Dessauw 2013 University of Nebraska-Lincoln

Design Of A Compliant Underactuated Robotic Finger With Coordinated Stiffness, Etienne Dessauw

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

The concept of underactuation has been previously developed in the robotic field for grasping applications. For these anthropomorphic grippers, the minimization of the number of input signals, or in other words underactuation, is the most expected characteristic. This method has become very popular in recent decades. Indeed, by minimizing the number of input signals, it minimizes the complexity of the system’s control and at the same time avoids increased weight and cost. The inconvenience of such a technique is that the design of this type of system remains a difficult task if the behavior of the underactuated set of joints …


Interleukin Expression After Injury And The Effects Of Interleukin-1 Receptor Antagonist, Connie S. Chamberlain, Ellen M. Leiferman, Kayt E. Frisch, Stacey L. Brickson, William L. Murphy, Geoffrey S. Baer, Ray Vanderby 2013 University of Wisconsin - Madison

Interleukin Expression After Injury And The Effects Of Interleukin-1 Receptor Antagonist, Connie S. Chamberlain, Ellen M. Leiferman, Kayt E. Frisch, Stacey L. Brickson, William L. Murphy, Geoffrey S. Baer, Ray Vanderby

Faculty Work Comprehensive List

Ligament healing follows a series of complex coordinated events involving various cell types, cytokines, as well as other factors, producing a mechanically inferior tissue more scar-like than native tissue. Macrophages provide an ongoing source of cytokines to modulate inflammatory cell adhesion and migration as well as fibroblast proliferation. Studying interleukins inherent to ligament healing during peak macrophage activation and angiogenesis may elucidate inflammatory mediators involved in subsequent scar formation. Herein, we used a rat healing model assayed after surgical transection of their medial collateral ligaments (MCLs). On days 3 and 7 post-injury, ligaments were collected and used for microarray analysis. …


The Effects Of Variation In Collagen D-Spacing On Compact Bone Viscoelasticity: A Finite Element Analysis, Miguel A. Mendoza 2013 California Polytechnic State University, San Luis Obispo

The Effects Of Variation In Collagen D-Spacing On Compact Bone Viscoelasticity: A Finite Element Analysis, Miguel A. Mendoza

Master's Theses

The D-spacing that is characteristic of collagen and its structural arrangement was previously thought to be a constant value. Much research is revealing that it is actually a distribution of values in biological tissues. Recent ovine experimentation has also shown that the D-spacing distribution is significantly altered following estrogen depletion. While ewes contain some major biological differences between their human counterparts, they are an economical and robust large animal model for postmenopausal osteoporosis. So, the exploration of the possible implications that D-spacing has on the mechanical properties of the whole bone utilizing animal models and computational methods is warranted. Six …


Finite Element Analysis And Validation Of Hip Joints With The Main Types Of Femoroacetabular Impingement, Kevin Lucas Mitchell 2013 California Polytechnic State University, San Luis Obispo

Finite Element Analysis And Validation Of Hip Joints With The Main Types Of Femoroacetabular Impingement, Kevin Lucas Mitchell

Master's Theses

Current research suggests that femoroacetabular impingement can be a cause of osteoarthritis. Femoroacetabular impingement is a condition that can affect both the femur and the pelvis of an individual. Femoroacetabular impingement can cause damage to the hip joint and its surrounding tissues. The articular cartilage and the labrum are both affected by this condition. A cam impingement is where a bony protrusion develops at the femoral head/neck junction. A pincer impingement is where a bony protrusion develops at the acetabular rim. Often, patients are seen with a combination of both impingements. The main goal of this study was to computationally …


Computational Biomechanical Modeling Of The Human Knee During Kneeling, Tariq R. Abo-Alhol 2013 University of Denver

Computational Biomechanical Modeling Of The Human Knee During Kneeling, Tariq R. Abo-Alhol

Electronic Theses and Dissertations

Total knee replacement benefits patients who suffer from severe knee pain or joint stiffness and other joint related illnesses that limit everyday activities. There has been an increase in the number of procedures performed each year and a need to evaluate the performance of these implants during specialized activities such as kneeling. Most computational studies lack insight into inter-patient variability and the results do not apply to large population. This study developed: (1) three-dimensional explicit finite element (FE) models to investigate natural and implanted knee joint kinematics and bone strain and (2) a platform to enable population-based evaluation by combining …


Subtalar Joint Instability: Diagnosis And Conservative Treatment, Julie Choisne 2013 Old Dominion University

Subtalar Joint Instability: Diagnosis And Conservative Treatment, Julie Choisne

Mechanical & Aerospace Engineering Theses & Dissertations

Subtalar instability may be caused by various ligamentous injuries. Combined instability at the ankle and subtalar joint is not adequately diagnosed. Further, isolated subtalar instability is usually misdiagnosed which may lead to long term damage to the joint. Developing a non-invasive and clinically practical tool to diagnose subtalar joint instability would be an important asset. The ability of an ankle brace, a common treatment for hindfoot instability, to promote stability for the subtalar joint was not well established. The purposes of this study were to 1) assess the kinematics of the subtalar, ankle, and hindfoot in the presence of isolated …


Analysis Of Acetabular Cup Orientation Effects On Stress Shielding In Total Hip Replacements Using Finite Element Methods, Brogan McGuire, Jennifer Gemkow, Brad Gausewitz, Alex Georges 2013 California Polytechnic State University, San Luis Obispo

Analysis Of Acetabular Cup Orientation Effects On Stress Shielding In Total Hip Replacements Using Finite Element Methods, Brogan Mcguire, Jennifer Gemkow, Brad Gausewitz, Alex Georges

Biomedical Engineering

Improper positioning of the acetabular cup has been shown to contribute to issues such as high wear rates and dislocations in total hip replacements. The differences in contact mechanics due to varying orientation of the acetabular cup may also significantly affect strain distribution in the femur. This study examined these effects of acetabular orientation changes and their contribution to stress shielding using finite element analysis. A solid model of a cementless total hip implant was obtained using 3D point scanning and implanted virtually into a femur solid model. The implanted femur model was imported into ABAQUS and loaded with a …


Evaluation Of The Anterior Talofibular And Calcaneofibular Ligament In Relation To Supination Ankle Sprains, Peter Tran 2013 California Polytechnic State University, San Luis Obispo

Evaluation Of The Anterior Talofibular And Calcaneofibular Ligament In Relation To Supination Ankle Sprains, Peter Tran

Biomedical Engineering

Ankle injuries have always posed an issue to a number of athletes. Sports that involve running and jumping accumulate about 25% of injuries correlating to ankle sprains. In most ankle sprains the inversion (supination) of the ankle cause damage to lateral ligaments. The two most common lateral ligaments to experience damage are the anterior talofibular (ATFL) and calcaneofibular (CFL) ligaments. The methods of taping and ankle braces have allowed athletes to prevent recurring sprains from occurring. However, sprains can still occur even when one or both methods are applied. The purpose of each method is to restrict the range of …


Design And Development Of A Stair Ascension Assistive Device For Transfemoral Amputees, Casey Michael Barbarino 2013 California Polytechnic State University, San Luis Obispo

Design And Development Of A Stair Ascension Assistive Device For Transfemoral Amputees, Casey Michael Barbarino

Master's Theses

Transfemoral amputees around the world experience increased difficulty in climbing stairs due to lack of muscle, balance, and other factors. The loss of a lower limb greatly diminishes the amount of natural force generation provided that is necessary to propel oneself up stairs. This study investigated possible solutions to the problem of stair ascension for transfemoral amputees by the means of designing and developing an externally attachable device to a prosthesis. The number of amputations from military service has greatly increased since 2008, which shows there is a clear need for assistive devices (Wenke, Krueger, & Ficke, 2012). With the …


Modeling The Zimmer Fitmore And Ml Taper Implantation, Tyler Kazuo Franklin 2013 California Polytechnic State University, San Luis Obispo

Modeling The Zimmer Fitmore And Ml Taper Implantation, Tyler Kazuo Franklin

Master's Theses

With more young adults requiring total hip

arthroplasties the need for bone saving implants becomes

more important. The Zimmer Fitmore is a new bone saving

implant that utilizes an implantation technique that

reduces the damage to the muscle tissue allowing for

patients to have a short recovery time as well as a new

design that allows it to rest on the medial cortex. There

has been anecdotal evidence that this device leads to early

revision within six months of implantation due to failures

occurring in the medial cortex. The main goal of this

study was to computationally model the Zimmer …


A Microfluidic Pretreatment Isoelectric Focusing Dc-Field Assisted H-Filter For The Separation Of Charged Particles, Cameron Sean Carroll 2013 California Polytechnic State University, San Luis Obispo

A Microfluidic Pretreatment Isoelectric Focusing Dc-Field Assisted H-Filter For The Separation Of Charged Particles, Cameron Sean Carroll

Biomedical Engineering

Microfluidic devices are small portable diagnostic chips that allow for analysis of a biologic sample at relatively low cost. This makes them ideal for settings where a hospital is unavailable. The microfluidic pretreatment isoelectric focusing DC-field assisted H-filter is a device that allows for the separation of differently charged particles in a biologic sample. It does this by employing the concepts of diffusion, electrophoresis, and isoelectric focusing. This is perfect for isolation of a desired analyte or separation of waste from a sample in order to achieve better diagnostic results. The device was first modeled mathematically and visually using Comsol. …


The Effects Of Toning Shoes On The Postural Stability Of Women, Kevin Farley, Audrey Niverson, Renee Rogge 2013 Rose-Hulman Institute of Technology

The Effects Of Toning Shoes On The Postural Stability Of Women, Kevin Farley, Audrey Niverson, Renee Rogge

Rose-Hulman Undergraduate Research Publications

Postural stability is the ability to maintain an upright posture and to keep the center of pressure (COP) within the limits of the body’s base of support. It is maintained through the dynamic integration of muscle activity and joint position. The foot, and therefore footwear, also plays a critical role in postural stability. The goal of this study is to determine the effects of toning shoes on the postural stability of women.


Effect Of Rolling On Viscoelastic Fluids Using A Novel Testing Device, Aswini Mangadu 2013 CUNY City College

Effect Of Rolling On Viscoelastic Fluids Using A Novel Testing Device, Aswini Mangadu

Dissertations and Theses

The purpose of this research thesis project was to develop a mechanical testing device that could enable us to load articular cartilage with a rolling/sliding motion. This novel device was then used to observe the effect of a rolling motion on the fluid film thickness of different lubricants (motor oil, synovial fluid and Hyaluronic Acid (HA)) to varying loads (1kg, 2,kg, 3kg and 4kg) and speeds (10, 25, 48 and 91 mm/s) applied on the sample fluids for 10 cycles. We were able to examine the effect of different speeds within each load for each of the fluid that was …


Distal Placement Of An End-To-Side Bypass Graft Anastomosis: A 3d Computational Study, John Di Cicco, Ayodeji Demuren 2013 Old Dominion University

Distal Placement Of An End-To-Side Bypass Graft Anastomosis: A 3d Computational Study, John Di Cicco, Ayodeji Demuren

Mechanical & Aerospace Engineering Faculty Publications

A three-dimensional (3D) computational fluid dynamics study of shear rates around distal end-to-side anastomoses has been conducted. Three 51% and three 75% cross-sectional area-reduced 6 mm cylinders were modeled each with a bypass cylinder attached at a 30-degree angle at different placements distal to the constriction. Steady, incompressible, Newtonian blood flow was assumed, and the full Reynolds-averaged Navier-Stokes equations, turbulent kinetic energy, and specific dissipation rate equations were solved on a locally structured multiblock mesh with hexahedral elements. Consequently, distal placement of an end-to-side bypass graft anastomosis was found to have an influence on the shear rate magnitudes. For the …


Digital Commons powered by bepress