Physiological Fluid Specific Agglomeration Patterns Diminish Gold Nanorod Photothermal Characteristics,
2013
University of Dayton
Physiological Fluid Specific Agglomeration Patterns Diminish Gold Nanorod Photothermal Characteristics, Kristen K. Comfort, Jared W. Speltz, Bradley M. Stacy, Larry R. Dosser, Saber M. Hussain
Chemical and Materials Engineering Faculty Publications
Investigations into the use of gold nanorods (Au-NRs) for biological applications are growing exponentially due to their distinctive physicochemical properties, which make them advantageous over other nanomaterials. Au-NRs are particularly renowned for their plasmonic characteristics, which generate a robust photothermal response when stimulated with light at a wavelength matching their surface plasmon resonance. Numerous reports have explored this nanophotonic phenomenon for temperature driven therapies; however, to date there is a significant knowledge gap pertaining to the kinetic heating profile of Au-NRs within a controlled physiological setting. In the present study, the impact of environmental composition on Au-NR behavior and degree …
Data Workflow In Large Scale Simulations Of Blood Flow In Aneurysms,
2013
Yale University
Data Workflow In Large Scale Simulations Of Blood Flow In Aneurysms, Paolo Di Achille, Jay D. Humphrey
Yale Day of Data
Aneurysms are responsibile for significant morbidity and mortality, and there is a need for an increased understanding of all the aspects of the natural history of these lesions. We are currently working to extend our analyses with the goal of creating models of aneurysmal progression that are able to predict rupture risk through the description of the evolving geometry, structure, properties, and loads.
Realization of patient specific models of the blood circulation necessitates a complex computationally and data intensive procedure that starts from the collection of medical images in a clinical setting and encompasses several stages of data processing on …
Design Optimization Of An Above-Knee Prosthesis With Energy Regeneration,
2013
Cleveland State University
Design Optimization Of An Above-Knee Prosthesis With Energy Regeneration, Taylor Barto, Holly Warner, Rick Rarick, Dan Simon
Undergraduate Research Posters 2013
Above-knee amputees who use a prosthetic leg typically have to compensate for its shortcomings with unnatural hip motions. This compensation eventually leads to adverse health issues such as arthritis. We propose an active prosthesis to improve performance. The motor in our prosthetic knee allows the patient to move his hip normally, thus reducing the possibility of ancillary health issues. To improve the efficiency of the prosthesis, we use the braking phase of the prosthesis to regenerate energy. By storing energy in a supercapacitor during braking, the prosthesis lasts longer between each charge than it would without regenerative braking. We are …
Towards A More Robust Lower Neck Compressive Injury Tolerance - An Approach Combining Multiple Test Methodologies,
2013
Wayne State University
Towards A More Robust Lower Neck Compressive Injury Tolerance - An Approach Combining Multiple Test Methodologies, Daniel Toomey, King H. Yang, N Yoganadan, F A. Pintar, C A. Van Ee
Biomedical Engineering Faculty Research Publications
Objective.The compressive tolerance of the cervical spine has traditionally been reported in terms of axial force at failure. Previous studies suggest that axial compressive force at failure is particularly sensitive to the alignment of the cervical vertebra and the end conditions of the test methodology used. The present study was designed to develop a methodology to combine the data of previous experiments into a diverse dataset utilizing multiple test methods to allow for the evaluation of the robustness of current and proposed eccentricity based injury criteria.
Methods. Data was combined from two studies composed of dynamic experiments including whole …
Why Is Ca3 More Vulnerable Than Ca1 In Experimental Models Of Controlled Cortical Impact-Induced Brain Injury?,
2013
Wayne State University
Why Is Ca3 More Vulnerable Than Ca1 In Experimental Models Of Controlled Cortical Impact-Induced Brain Injury?, Haojie Mao, Benjamin S. Elkin, Vinay V. Genthikatti, Barclay Morrison Iii, King H. Yang
Biomedical Engineering Faculty Research Publications
One interesting finding of controlled cortical impact (CCI) experiments is that the CA3 region of the hippocampus, which is positioned further from the impact than the CA1 region, is reported as being more injured. The current literature has suggested a positive correlation between brain tissue stretch and neuronal cell loss. However, it is counterintuitive to assume that CA3 is stretched more during CCI injury. Recent mechanical studies of the brain have reported on a level of spatial heterogeneity not previously appreciated—the finding that CA1 was significantly stiffer than all other regions tested and that CA3 was one of the most …
Finite Element Models Of The Knee & Hip Joints: Using Opensim To Predict Muscle Forces,
2013
California Polytechnic State University - San Luis Obispo
Finite Element Models Of The Knee & Hip Joints: Using Opensim To Predict Muscle Forces, Kevin S. Jones, Spencer D. Wangerin, Jeffrey D. Pyle, Stephen M. Klisch, Scott J. Hazelwood
STAR Program Research Presentations
Quantitative data of stresses and strains in the cartilage of the knee and hip joints are required to design prostheses and can be used to give accurate advice to patients with cartilage damage as to which activities should be avoided. Instrumented hip implants can only give the overall resultant force in the joint, not the stresses and strains throughout the cartilage. Finite Element (FE) models of the Knee and Hip are being constructed in order to obtain the stresses and strains in articular (of the joint) cartilage. Muscle forces and joint contact forces are required as inputs to these FE …
Design Of A Compliant Underactuated Robotic Finger With Coordinated Stiffness,
2013
University of Nebraska-Lincoln
Design Of A Compliant Underactuated Robotic Finger With Coordinated Stiffness, Etienne Dessauw
Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research
The concept of underactuation has been previously developed in the robotic field for grasping applications. For these anthropomorphic grippers, the minimization of the number of input signals, or in other words underactuation, is the most expected characteristic. This method has become very popular in recent decades. Indeed, by minimizing the number of input signals, it minimizes the complexity of the system’s control and at the same time avoids increased weight and cost. The inconvenience of such a technique is that the design of this type of system remains a difficult task if the behavior of the underactuated set of joints …
Interleukin Expression After Injury And The Effects Of Interleukin-1 Receptor Antagonist,
2013
University of Wisconsin - Madison
Interleukin Expression After Injury And The Effects Of Interleukin-1 Receptor Antagonist, Connie S. Chamberlain, Ellen M. Leiferman, Kayt E. Frisch, Stacey L. Brickson, William L. Murphy, Geoffrey S. Baer, Ray Vanderby
Faculty Work Comprehensive List
Ligament healing follows a series of complex coordinated events involving various cell types, cytokines, as well as other factors, producing a mechanically inferior tissue more scar-like than native tissue. Macrophages provide an ongoing source of cytokines to modulate inflammatory cell adhesion and migration as well as fibroblast proliferation. Studying interleukins inherent to ligament healing during peak macrophage activation and angiogenesis may elucidate inflammatory mediators involved in subsequent scar formation. Herein, we used a rat healing model assayed after surgical transection of their medial collateral ligaments (MCLs). On days 3 and 7 post-injury, ligaments were collected and used for microarray analysis. …
The Effects Of Variation In Collagen D-Spacing On Compact Bone Viscoelasticity: A Finite Element Analysis,
2013
California Polytechnic State University, San Luis Obispo
The Effects Of Variation In Collagen D-Spacing On Compact Bone Viscoelasticity: A Finite Element Analysis, Miguel A. Mendoza
Master's Theses
The D-spacing that is characteristic of collagen and its structural arrangement was previously thought to be a constant value. Much research is revealing that it is actually a distribution of values in biological tissues. Recent ovine experimentation has also shown that the D-spacing distribution is significantly altered following estrogen depletion. While ewes contain some major biological differences between their human counterparts, they are an economical and robust large animal model for postmenopausal osteoporosis. So, the exploration of the possible implications that D-spacing has on the mechanical properties of the whole bone utilizing animal models and computational methods is warranted. Six …
Finite Element Analysis And Validation Of Hip Joints With The Main Types Of Femoroacetabular Impingement,
2013
California Polytechnic State University, San Luis Obispo
Finite Element Analysis And Validation Of Hip Joints With The Main Types Of Femoroacetabular Impingement, Kevin Lucas Mitchell
Master's Theses
Current research suggests that femoroacetabular impingement can be a cause of osteoarthritis. Femoroacetabular impingement is a condition that can affect both the femur and the pelvis of an individual. Femoroacetabular impingement can cause damage to the hip joint and its surrounding tissues. The articular cartilage and the labrum are both affected by this condition. A cam impingement is where a bony protrusion develops at the femoral head/neck junction. A pincer impingement is where a bony protrusion develops at the acetabular rim. Often, patients are seen with a combination of both impingements. The main goal of this study was to computationally …
Computational Biomechanical Modeling Of The Human Knee During Kneeling,
2013
University of Denver
Computational Biomechanical Modeling Of The Human Knee During Kneeling, Tariq R. Abo-Alhol
Electronic Theses and Dissertations
Total knee replacement benefits patients who suffer from severe knee pain or joint stiffness and other joint related illnesses that limit everyday activities. There has been an increase in the number of procedures performed each year and a need to evaluate the performance of these implants during specialized activities such as kneeling. Most computational studies lack insight into inter-patient variability and the results do not apply to large population. This study developed: (1) three-dimensional explicit finite element (FE) models to investigate natural and implanted knee joint kinematics and bone strain and (2) a platform to enable population-based evaluation by combining …
Subtalar Joint Instability: Diagnosis And Conservative Treatment,
2013
Old Dominion University
Subtalar Joint Instability: Diagnosis And Conservative Treatment, Julie Choisne
Mechanical & Aerospace Engineering Theses & Dissertations
Subtalar instability may be caused by various ligamentous injuries. Combined instability at the ankle and subtalar joint is not adequately diagnosed. Further, isolated subtalar instability is usually misdiagnosed which may lead to long term damage to the joint. Developing a non-invasive and clinically practical tool to diagnose subtalar joint instability would be an important asset. The ability of an ankle brace, a common treatment for hindfoot instability, to promote stability for the subtalar joint was not well established. The purposes of this study were to 1) assess the kinematics of the subtalar, ankle, and hindfoot in the presence of isolated …
Analysis Of Acetabular Cup Orientation Effects On Stress Shielding In Total Hip Replacements Using Finite Element Methods,
2013
California Polytechnic State University, San Luis Obispo
Analysis Of Acetabular Cup Orientation Effects On Stress Shielding In Total Hip Replacements Using Finite Element Methods, Brogan Mcguire, Jennifer Gemkow, Brad Gausewitz, Alex Georges
Biomedical Engineering
Improper positioning of the acetabular cup has been shown to contribute to issues such as high wear rates and dislocations in total hip replacements. The differences in contact mechanics due to varying orientation of the acetabular cup may also significantly affect strain distribution in the femur. This study examined these effects of acetabular orientation changes and their contribution to stress shielding using finite element analysis. A solid model of a cementless total hip implant was obtained using 3D point scanning and implanted virtually into a femur solid model. The implanted femur model was imported into ABAQUS and loaded with a …
Evaluation Of The Anterior Talofibular And Calcaneofibular Ligament In Relation To Supination Ankle Sprains,
2013
California Polytechnic State University, San Luis Obispo
Evaluation Of The Anterior Talofibular And Calcaneofibular Ligament In Relation To Supination Ankle Sprains, Peter Tran
Biomedical Engineering
Ankle injuries have always posed an issue to a number of athletes. Sports that involve running and jumping accumulate about 25% of injuries correlating to ankle sprains. In most ankle sprains the inversion (supination) of the ankle cause damage to lateral ligaments. The two most common lateral ligaments to experience damage are the anterior talofibular (ATFL) and calcaneofibular (CFL) ligaments. The methods of taping and ankle braces have allowed athletes to prevent recurring sprains from occurring. However, sprains can still occur even when one or both methods are applied. The purpose of each method is to restrict the range of …
Design And Development Of A Stair Ascension Assistive Device For Transfemoral Amputees,
2013
California Polytechnic State University, San Luis Obispo
Design And Development Of A Stair Ascension Assistive Device For Transfemoral Amputees, Casey Michael Barbarino
Master's Theses
Transfemoral amputees around the world experience increased difficulty in climbing stairs due to lack of muscle, balance, and other factors. The loss of a lower limb greatly diminishes the amount of natural force generation provided that is necessary to propel oneself up stairs. This study investigated possible solutions to the problem of stair ascension for transfemoral amputees by the means of designing and developing an externally attachable device to a prosthesis. The number of amputations from military service has greatly increased since 2008, which shows there is a clear need for assistive devices (Wenke, Krueger, & Ficke, 2012). With the …
Modeling The Zimmer Fitmore And Ml Taper Implantation,
2013
California Polytechnic State University, San Luis Obispo
Modeling The Zimmer Fitmore And Ml Taper Implantation, Tyler Kazuo Franklin
Master's Theses
With more young adults requiring total hip
arthroplasties the need for bone saving implants becomes
more important. The Zimmer Fitmore is a new bone saving
implant that utilizes an implantation technique that
reduces the damage to the muscle tissue allowing for
patients to have a short recovery time as well as a new
design that allows it to rest on the medial cortex. There
has been anecdotal evidence that this device leads to early
revision within six months of implantation due to failures
occurring in the medial cortex. The main goal of this
study was to computationally model the Zimmer …
A Microfluidic Pretreatment Isoelectric Focusing Dc-Field Assisted H-Filter For The Separation Of Charged Particles,
2013
California Polytechnic State University, San Luis Obispo
A Microfluidic Pretreatment Isoelectric Focusing Dc-Field Assisted H-Filter For The Separation Of Charged Particles, Cameron Sean Carroll
Biomedical Engineering
Microfluidic devices are small portable diagnostic chips that allow for analysis of a biologic sample at relatively low cost. This makes them ideal for settings where a hospital is unavailable. The microfluidic pretreatment isoelectric focusing DC-field assisted H-filter is a device that allows for the separation of differently charged particles in a biologic sample. It does this by employing the concepts of diffusion, electrophoresis, and isoelectric focusing. This is perfect for isolation of a desired analyte or separation of waste from a sample in order to achieve better diagnostic results. The device was first modeled mathematically and visually using Comsol. …
The Effects Of Toning Shoes On The Postural Stability Of Women,
2013
Rose-Hulman Institute of Technology
The Effects Of Toning Shoes On The Postural Stability Of Women, Kevin Farley, Audrey Niverson, Renee Rogge
Rose-Hulman Undergraduate Research Publications
Postural stability is the ability to maintain an upright posture and to keep the center of pressure (COP) within the limits of the body’s base of support. It is maintained through the dynamic integration of muscle activity and joint position. The foot, and therefore footwear, also plays a critical role in postural stability. The goal of this study is to determine the effects of toning shoes on the postural stability of women.
Effect Of Rolling On Viscoelastic Fluids Using A Novel Testing Device,
2013
CUNY City College
Effect Of Rolling On Viscoelastic Fluids Using A Novel Testing Device, Aswini Mangadu
Dissertations and Theses
The purpose of this research thesis project was to develop a mechanical testing device that could enable us to load articular cartilage with a rolling/sliding motion. This novel device was then used to observe the effect of a rolling motion on the fluid film thickness of different lubricants (motor oil, synovial fluid and Hyaluronic Acid (HA)) to varying loads (1kg, 2,kg, 3kg and 4kg) and speeds (10, 25, 48 and 91 mm/s) applied on the sample fluids for 10 cycles. We were able to examine the effect of different speeds within each load for each of the fluid that was …
Distal Placement Of An End-To-Side Bypass Graft Anastomosis: A 3d Computational Study,
2013
Old Dominion University
Distal Placement Of An End-To-Side Bypass Graft Anastomosis: A 3d Computational Study, John Di Cicco, Ayodeji Demuren
Mechanical & Aerospace Engineering Faculty Publications
A three-dimensional (3D) computational fluid dynamics study of shear rates around distal end-to-side anastomoses has been conducted. Three 51% and three 75% cross-sectional area-reduced 6 mm cylinders were modeled each with a bypass cylinder attached at a 30-degree angle at different placements distal to the constriction. Steady, incompressible, Newtonian blood flow was assumed, and the full Reynolds-averaged Navier-Stokes equations, turbulent kinetic energy, and specific dissipation rate equations were solved on a locally structured multiblock mesh with hexahedral elements. Consequently, distal placement of an end-to-side bypass graft anastomosis was found to have an influence on the shear rate magnitudes. For the …