Magnetic Resonance Imaging And Histology Correlation In The Neocortex In Temporal Lobe Epilepsy.,
2015
Robarts Research Institute
Magnetic Resonance Imaging And Histology Correlation In The Neocortex In Temporal Lobe Epilepsy., Maged Goubran, Robert R Hammond, Sandrine De Ribaupierre, Jorge G Burneo, Seyed Mirsattari, David A Steven, Andrew G Parrent, Terry M Peters, Ali R Khan
Robarts Imaging Publications
OBJECTIVE: To investigate the histopathological correlates of quantitative relaxometry and diffusion tensor imaging (DTI) and to determine their efficacy in epileptogenic lesion detection for preoperative evaluation of focal epilepsy.
METHODS: We correlated quantitative relaxometry and DTI with histological features of neuronal density and morphology in 55 regions of the temporal lobe neocortex, selected from 13 patients who underwent epilepsy surgery. We made use of a validated nonrigid image registration protocol to obtain accurate correspondences between in vivo magnetic resonance imaging and histology images.
RESULTS: We found T1 to be a predictor of neuronal density in the neocortical gray matter (GM) …
Frequency Domain Ultrasound Waveform Tomography Breast Imaging,
2015
Wayne State University
Frequency Domain Ultrasound Waveform Tomography Breast Imaging, Gursharan Singh Sandhu
Wayne State University Dissertations
Ultrasound tomography is an emerging modality for imaging breast tissue for the detection of disease. Using the principles of full waveform inversion, high-resolution quantitative sound speed and attenuation maps of the breast can be created. In this thesis, we introduce some basic principles of imaging breast disease and the formalism of sound wave propagation. We present numerical methods to model acoustic wave propagation as well methods to solve the corresponding inverse problem. Numerical simulations of sound speed and attenuation reconstructions are used to assess the efficacy of the algorithm. A careful review of the preprocessing techniques needed for the successful …
Computer Aided Diagnosis Of Oral Cancer: Using Time-Step Ct Images,
2015
Missouri University of Science and Technology
Computer Aided Diagnosis Of Oral Cancer: Using Time-Step Ct Images, Jonathan T. Scott
Masters Theses
"In medical imaging it is a very common practice to use a technique known as Time-Step imaging in patients who might develop cancer. Time-Step imaging it a very powerful technique, however it can lead to unmanageable amounts of image data. Previously the only way to search all of this data was to manually look through all of the files. This had to be done by trained professionals who knew what to look for within the images and make a judgment about the patient based on the images. This paper discusses the development of an algorithm to have a computer search …
Quantifying Magnetic Moments And Susceptibilities Of Small Cylindrical And Spherical Objects In Mri,
2015
Wayne State University
Quantifying Magnetic Moments And Susceptibilities Of Small Cylindrical And Spherical Objects In Mri, Ching-Yi Hsieh
Wayne State University Dissertations
Purpose: The purpose of this PhD work is to develop a method for accurately quantifying effective magnetic moments and susceptibility of either cylindrical or spherical-like small objects from magnetic resonance imaging (MRI). A standard 3D gradient echo sequence with only one echo time is intended for our approach to measure the effective magnetic moment of a given object of interest. For the quantification of the susceptibility in the cylindrical objects at different orientations, a standard 3D gradient echo sequence with only one or two echo times is needed.
Methods: Our method is to sum over complex MR signals around the …
Noncontact Diffuse Correlation Tomography Of Breast Tumor,
2015
University of Kentucky
Noncontact Diffuse Correlation Tomography Of Breast Tumor, Lian He
Theses and Dissertations--Biomedical Engineering
Since aggressive cancers are frequently hypermetabolic with angiogenic vessels, quantification of blood flow (BF) can be vital for cancer diagnosis. Our laboratory has developed a noncontact diffuse correlation tomography (ncDCT) system for 3-D imaging of BF distribution in deep tissues (up to centimeters). The ncDCT system employs two sets of optical lenses to project source and detector fibers respectively onto the tissue surface, and applies finite element framework to model light transportation in complex tissue geometries. This thesis reports our first step to adapt the ncDCT system for 3-D imaging of BF contrasts in human breast tumors. A commercial 3-D …
Femtosecond Laser Beam Propagation Through Corneal Tissue: Evaluation Of Therapeutic Laser-Stimulated Second And Third-Harmonic Generation,
2015
Virginia Commonwealth University
Femtosecond Laser Beam Propagation Through Corneal Tissue: Evaluation Of Therapeutic Laser-Stimulated Second And Third-Harmonic Generation, William R. Calhoun Iii
Theses and Dissertations
One of the most recent advancements in laser technology is the development of ultrashort pulsed femtosecond lasers (FSLs). FSLs are improving many fields due to their unique extreme precision, low energy and ablation characteristics. In the area of laser medicine, ophthalmic surgeries have seen very promising developments. Some of the most commonly performed surgical operations in the world, including laser-assisted in-situ keratomileusis (LASIK), lens replacement (cataract surgery), and keratoplasty (cornea transplant), now employ FSLs for their unique abilities that lead to improved clinical outcome and patient satisfaction.
The application of FSLs in medical therapeutics is a recent development, and although …
Diffuse Optical Measurements Of Head And Neck Tumor Hemodynamics For Early Prediction Of Chemo-Radiation Therapy Outcomes,
2015
University of Kentucky
Diffuse Optical Measurements Of Head And Neck Tumor Hemodynamics For Early Prediction Of Chemo-Radiation Therapy Outcomes, Lixin Dong
Theses and Dissertations--Biomedical Engineering
Chemo-radiation therapy is a principal modality for the treatment of head and neck cancers, and its efficacy depends on the interaction of tumor oxygen with free radicals. In this study, we adopted a novel hybrid diffuse optical instrument combining a commercial frequency-domain tissue oximeter (Imagent) and a custom-made diffuse correlation spectroscopy (DCS) flowmeter, which allowed for simultaneous measurements of tumor blood flow and blood oxygenation. Using this hybrid instrument we continually measured tumor hemodynamic responses to chemo-radiation therapy over the treatment period of 7 weeks. We also explored monitoring dynamic tumor hemodynamic changes during radiation delivery. Blood flow data analysis …
Computer Aided Detection Of Oral Lesions On Ct Images,
2015
Missouri University of Science and Technology
Computer Aided Detection Of Oral Lesions On Ct Images, Shaikat Mahmood Galib
Masters Theses
"Oral lesions are important findings on computed tomography images. They are difficult to detect on CT images because of low contrast, arbitrary orientation of objects, complicated topology and lack of clear lines indicating lesions. In this thesis, a fully automatic method to detect oral lesions from dental CT images is proposed to identify (1) Closed boundary lesions and (2) Bone deformation lesions. Two algorithms were developed to recognize these two types of lesions, which cover most of the lesion types that can be found on CT images. The results were validated using a dataset of 52 patients. Using non training …
Adaptive Graph Construction For Isomap Manifold Learning,
2015
Old Dominion University
Adaptive Graph Construction For Isomap Manifold Learning, Loc Tran, Zezhong Zheng, Guoquing Zhou, Jiang Li, Karen O. Egiazarian (Ed.), Sos S. Agaian (Ed.), Atanas P. Gotchev (Ed.)
Electrical & Computer Engineering Faculty Publications
Isomap is a classical manifold learning approach that preserves geodesic distance of nonlinear data sets. One of the main drawbacks of this method is that it is susceptible to leaking, where a shortcut appears between normally separated portions of a manifold. We propose an adaptive graph construction approach that is based upon the sparsity property of the ℓ1 norm. The ℓ1 enhanced graph construction method replaces k-nearest neighbors in the classical approach. The proposed algorithm is first tested on the data sets from the UCI data base repository which showed that the proposed approach performs better than …
Monolithic Optofluidic Ring Resonator Lasers Created By Femtosecond Laser Nanofabrication,
2015
Air Force Institute of Technology
Monolithic Optofluidic Ring Resonator Lasers Created By Femtosecond Laser Nanofabrication, Hengky Chandrahalim, Qiushu Chen, Ali A. Said, Mark Dugan, Xudong Fan
Faculty Publications
We designed, fabricated, and characterized a monolithically integrated optofluidic ring resonator laser that is mechanically, thermally, and chemically robust. The entire device, including the ring resonator channel and sample delivery microfluidics, was created in a block of fused-silica glass using a 3-dimensional femtosecond laser writing process. The gain medium, composed of Rhodamine 6G (R6G) dissolved in quinoline, was flowed through the ring resonator. Lasing was achieved at a pump threshold of approximately 15 μJ/mm2. Detailed analysis shows that the Q-factor of the optofluidic ring resonator is 3.3 × 104, which is limited by both solvent …
Evaluation Of The Signature Molecular Descriptor With Blosum62 And An All-Atom Description For Use In Sequence Alignment Of Proteins,
2015
The University Of Akron
Evaluation Of The Signature Molecular Descriptor With Blosum62 And An All-Atom Description For Use In Sequence Alignment Of Proteins, Lindsay M. Aichinger
Williams Honors College, Honors Research Projects
This Honors Project focused on a few aspects of this topic. The second is comparing the molecular signature kernels to three of the BLOSUM matrices (30, 62, and 90) to test the accuracy of the mathematical model. The kernel matrix was manipulated in order to improve the relationship by focusing on side groups and also by changing how the structure was represented in the matrix by increasing the initial height distance from the central atom (Height 1 and Height 2 included).
There were multiple design constraints for this project. The first was the comparison with the BLOSUM matrices (30, 62, …
Multi-Surface Simplex Spine Segmentation For Spine Surgery Simulation And Planning,
2015
Old Dominion University
Multi-Surface Simplex Spine Segmentation For Spine Surgery Simulation And Planning, Rabia Haq
Computational Modeling & Simulation Engineering Theses & Dissertations
This research proposes to develop a knowledge-based multi-surface simplex deformable model for segmentation of healthy as well as pathological lumbar spine data. It aims to provide a more accurate and robust segmentation scheme for identification of intervertebral disc pathologies to assist with spine surgery planning. A robust technique that combines multi-surface and shape statistics-aware variants of the deformable simplex model is presented. Statistical shape variation within the dataset has been captured by application of principal component analysis and incorporated during the segmentation process to refine results. In the case where shape statistics hinder detection of the pathological region, user-assistance is …
Quantitative Spatial Frequency Fluorescence Imaging In The Sub-Diffusive Domain For Image-Guided Glioma Resection,
2015
University of Toronto
Quantitative Spatial Frequency Fluorescence Imaging In The Sub-Diffusive Domain For Image-Guided Glioma Resection, Mira Sibai, Israel Veilleux, Jonathan T. Elliott, Frederic Leblond, Brian Wilson
Dartmouth Scholarship
Intraoperative 5- aminolevulinic acid induced-Protoporphyrin IX (PpIX) fluorescence guidance enables maximum safe resection of glioblastomas by providing surgeons with real-time tumor optical contrast. However, visual assessment of PpIX fluorescence is subjective and limited by the distorting effects of light attenuation and tissue autofluorescence. We have previously shown that non-invasive point measurements of absolute PpIX concentration identifies residual tumor that is otherwise non-detectable. Here, we extend this approach to wide-field quantitative fluorescence imaging by implementing spatial frequency domain imaging to recover tissue optical properties across the field-of-view in phantoms and ex vivo tissue.
Real-Time Temperature Imaging Using Ultrasonic Change In Backscattered Energy,
2014
Washington University in St. Louis
Real-Time Temperature Imaging Using Ultrasonic Change In Backscattered Energy, Weiyuan Zhao
McKelvey School of Engineering Graduate Student Theses & Dissertations
Thermal therapy from low-temperature cryosurgery to high-temperature ablation of tumors and unwanted electrical pathways has gained increased attention. Temperature imaging (TI) from magnetic resonance studies is the de facto standard for volumetric estimation of temperature. Ultrasound has the advantages of being cheap, portable, non-invasive and non-ionizing. Our group showed in predictions for single scatterers, simulations of scatterer populations and measurements in 1D, 2D and 3D, that CBE changed monotonically with temperature with 1oC accuracy. An obstacle to clinical application of CBE TI is estimation of temperature in real time, which is limited by time for motion compensation (MC). …
Data Completion Methods For Improved Developmental Stage Annotation Of Drosophila Embryos In Images,
2014
Old Dominion University
Data Completion Methods For Improved Developmental Stage Annotation Of Drosophila Embryos In Images, Chitsanu Janyalikit
Electrical & Computer Engineering Theses & Dissertations
Drosophila melanogaster is a dominant model organism for studying the function of animal genes in initial stages of embryogenesis. Usually, images containing Drosophila gene expression patterns are captured at different developmental stages to study the interconnection of animal genes. To achieve most biologically meaningful results, gene expression images from a similar stage should be compared. Currently, biologists manually classify embryos in images into different stages, which is time intensive and infeasible for current massively produced gene expression images. Therefore, there is a need to develop an automatic system for the annotation.
Gene expression information in embryo images usually appears as …
Applications Of Novel Mri Technologies In Tissue Engineering And Disease Diagnosis,
2014
University of Nebraska-Lincoln
Applications Of Novel Mri Technologies In Tissue Engineering And Disease Diagnosis, Vahid Khalilzad-Sharghi
Department of Agricultural and Biological Systems Engineering: Dissertations, Theses, and Student Research
Magnetic resonance imaging (MRI) and magnetic resonance elastography (MRE) are increasingly under investigation to explore their potential role in establishing effective evaluation methods for the procedure of tissue regeneration carried out in vitro, in vivo, and in disease diagnosis. To this end, there is a continuous pursuit of novel tools both in vitro and in vivo. For instance, there is a great need for the development and evaluation of an MR-compatible incubation system that enables simultaneous monitoring and culturing of cell and tissue constructs using MRI techniques. Such an imagingcompatible incubation system eliminates exposing the culture to the risks of …
Pixel-Based Absorption Correction For Dual-Tracer Fluorescence Imaging Of Receptor Binding Potential,
2014
Dartmouth College
Pixel-Based Absorption Correction For Dual-Tracer Fluorescence Imaging Of Receptor Binding Potential, Stephen C. Kanick, Kenneth M. Tichauer, Jason Gunn, Kimberley S. Samkoe, Brian W. Pogue
Dartmouth Scholarship
Ratiometric approaches to quantifying molecular concentrations have been used for decades in microscopy, but have rarely been exploited in vivo until recently. One dual-tracer approach can utilize an untargeted reference tracer to account for non-specific uptake of a receptor-targeted tracer, and ultimately estimate receptor binding potential quantitatively. However, interpretation of the relative dynamic distribution kinetics is confounded by differences in local tissue absorption at the wavelengths used for each tracer. This study simulated the influence of absorption on fluorescence emission intensity and depth sensitivity at typical near-infrared fluorophore wavelength bands near 700 and 800 nm in mouse skin in order …
Apparatus And Method For Remote Assessment And Therapy Management In Medical Devices Via Interface Systems,
2014
Kettering University
Apparatus And Method For Remote Assessment And Therapy Management In Medical Devices Via Interface Systems, Jeffrey Hargrove, Robert M. Ford, Thomas B. Johnson
Mechanical Engineering Patents
A remote medical assessment and therapy management apparatus comprising a center user interface, a center computer coupleable with the center user interface. The center computer displays information via the center user interface for use in developing a therapeutic prescription and receives therapeutic control inputs from a user. A remote device includes a medical diagnostic instrument for acquiring biophysical data from a patient, a medical therapeutic instrument that provides a therapy to the patient, and a remote computer that receives diagnostic signals from the diagnostic instrument and transmits therapeutic control signals to the therapeutic instrument. A network interface is connected between …
Anatomy-Based Transmission Factors For Technique Optimization In Portable Chest X-Ray,
2014
Cleveland State University
Anatomy-Based Transmission Factors For Technique Optimization In Portable Chest X-Ray, Chris L. Liptak, W. Paul Segars, Ashraf G. Morgan, Frank F. Dong, Xiang Li
Undergraduate Research Posters 2014
Currently, portable x-ray examinations do not employ automatic exposure control (AEC). To aid in the design of a size-specific technique chart, acrylic slabs of various thicknesses are often used to estimate x-ray transmission factors for patients of various body thicknesses. This approach, while simple, does not account for patient anatomy, tissue heterogeneity, and the attenuation properties of the human body. To better account for these factors, in this work, we determined x-ray transmission factors using computational patient models that are anatomically realistic. A Monte Carlo program was developed to model a portable x-ray system. Detailed modeling was done of the …
Sub-Diffusive Scattering Parameter Maps Recovered Using Wide-Field High-Frequency Structured Light Imaging,
2014
Dartmouth College
Sub-Diffusive Scattering Parameter Maps Recovered Using Wide-Field High-Frequency Structured Light Imaging, Stephen C. Kanick, David M. Mcclatchy, Venkataramanan Krishnaswamy, Jonathan T. Elliott, Keith D. Paulsen, Brian W. Pogue
Dartmouth Scholarship
This study investigates the hypothesis that structured light reflectance imaging with high spatial frequency patterns (fx) can be used to quantitatively map the anisotropic scattering phase function distribution (P(θs)) in turbid media. Monte Carlo simulations were used in part to establish a semi-empirical model of demodulated reflectance (Rd) in terms of dimensionless scattering (μ′sf−1x) and γ, a metric of the first two moments of the P(θs) distribution. Experiments completed in tissue-simulating phantoms showed that simultaneous analysis of Rd spectra sampled at multiple f …