Open Access. Powered by Scholars. Published by Universities.®

Bioimaging and Biomedical Optics Commons

Open Access. Powered by Scholars. Published by Universities.®

683 Full-Text Articles 1,564 Authors 260,977 Downloads 77 Institutions

All Articles in Bioimaging and Biomedical Optics

Faceted Search

683 full-text articles. Page 24 of 31.

Circle Of Willis Model For Transcranial Doppler Ultrasound Training, Conner J. Beyersdorf, Ben Hage, Greg Bashford 2016 University of Nebraska-Lincoln

Circle Of Willis Model For Transcranial Doppler Ultrasound Training, Conner J. Beyersdorf, Ben Hage, Greg Bashford

UCARE: Research Products

Transcranial Doppler (TCD) ultrasound is a technique involving the use of high frequency transmitters to measure intracranial blood flow. The brain is supplied by blood in an arterial anastomosis called the Circle of Willis. Using TCD ultrasound on the circle is difficult and requires practice and teaching. A functional model of the Circle of Willis could prove to be a valuable teaching tool. Through the use of AutoCAD and 3D printing software, an anatomically accurate model was created and set in gelatin phantom inside of a plastic skull. Milk was pumped through the model with a peristaltic pump to simulate …


Cerebrovascular Reactivity Change With Increased Intracranial Pressure, Madison Burger, M. Alwatban, Allison Porter, Ben Hage, Greg Bashford 2016 University of Nebraska-Lincoln

Cerebrovascular Reactivity Change With Increased Intracranial Pressure, Madison Burger, M. Alwatban, Allison Porter, Ben Hage, Greg Bashford

UCARE: Research Products

Cerebrovascular reactivity (CVR) is an important regulatory factor of the brain. The parameter controls the dilation and constriction of blood vessels in the brain in response to certain stimuli, such as carbon dioxide. Abnormal CVR values could potentially be indicators of poorly functioning regulatory systems. Testing of CVR is one method of assessing the brain's regulatory capabilities. The purpose of this study was to test for a relationship between CVR and intracranial pressure (ICP).

In this study, increased intracranial pressure was created in 4 female subjects through head down tilt, using an inversion table. Subjects were lowered in the table …


Analysis Of Breath-Holding Index As An Assessment Of Cerebrovascular Reactivity, Allison P. Porter, Madison Burger, Mohammed Alwatban, Benjamin Hage, Greg Bashford 2016 University of Nebraska-Lincoln

Analysis Of Breath-Holding Index As An Assessment Of Cerebrovascular Reactivity, Allison P. Porter, Madison Burger, Mohammed Alwatban, Benjamin Hage, Greg Bashford

UCARE: Research Products

Cerebrovascular reactivity (CVR) is a key factor in regulating blood flow into the brain, and a marker for vascular disease. If the brain's regulatory system is not working, a patient may be in serious trouble. Testing of CVR is one method of assessing the brain's regulatory capabilities. Transcranial Doppler ultrasound (TCD) is one tool to measure CVR. In this method, carbon dioxide in the blood is transiently increased (such as with the holding of breath), and the resulting blood flow in the brain is measured. In this study, we are going to measure the variability of the breathholding index.

Within …


Injury Risk Assessment Of The Femur In Children With Osteogenesis Imperfecta, Jessica Marie Fritz 2016 Marquette University

Injury Risk Assessment Of The Femur In Children With Osteogenesis Imperfecta, Jessica Marie Fritz

Dissertations (1934 -)

Osteogenesis imperfecta (OI) is a genetic disorder characterized by increased bone fragility and decreased bone mass, which leads to high rates of bone fracture. OI has a prevalence of 1/5,000 to 1/10,000 in the United States. About 90% of persons with OI have a genetic mutation in the coding for collagen type I, which is the major protein of connective tissues, including bone. While its prevalence classifies it as a rare disease, it is the most common disorder of bone etiology. Until recently, little was known about the mechanics and materials of OI bone or their impact on fracture risk. …


Structural-Functional Brain Connectivity Underlying Integrative Sensorimotor Function After Stroke, Benjamin Thomas Kalinosky 2016 Marquette University

Structural-Functional Brain Connectivity Underlying Integrative Sensorimotor Function After Stroke, Benjamin Thomas Kalinosky

Dissertations (1934 -)

In this dissertation research project, we demonstrated the relationship between the structural and functional connections across the brain in stroke survivors. We used this information to predict arm function in stroke survivors, suggesting that the tools developed through this research will be useful for prescribing individualized rehabilitation strategies in people after stroke. Current clinical methods for rehabilitating sensorimotor function after stroke are not based on the locus of injury in the brain. Instead, therapies are generalized, treating symptoms such as weakness and spasticity. This results in outcomes that are highly variable, with severity of impairment immediately following stroke as the …


Increasing 18f-Fdg Pet/Ct Capabilities In Radiotherapy For Lung And Esophageal Cancer Via Image Feature Analysis, Jasmine Alexandria Oliver 2016 University of South Florida

Increasing 18f-Fdg Pet/Ct Capabilities In Radiotherapy For Lung And Esophageal Cancer Via Image Feature Analysis, Jasmine Alexandria Oliver

USF Tampa Graduate Theses and Dissertations

Positron Emission Tomography (PET) is an imaging modality that has become increasingly beneficial in Radiotherapy by improving treatment planning (1). PET reveals tumor volumes that are not well visualized on computed tomography CT or MRI, recognizes metastatic disease, and assesses radiotherapy treatment (1). It also reveals areas of the tumor that are more radiosensitive allowing for dose painting - a non-homogenous dose treatment across the tumor (1). However, PET is not without limitations. The quantitative unit of PET images, the Standardized Uptake Value (SUV), is affected by many factors such as reconstruction algorithm, patient weight, and tracer uptake time (2). …


Investigation Of Hippocampal Substructures In Focal Temporal Lobe Epilepsy With And Without Hippocampal Sclerosis At 7t., Brendan G Santyr, Maged Goubran, Jonathan C Lau, Benjamin Y M Kwan, Fateme Salehi, Donald H Lee, Seyed M Mirsattari, Jorge G Burneo, David A Steven, Andrew G Parrent, Sandrine de Ribaupierre, Robert R Hammond, Terry M Peters, Ali R Khan 2016 Robarts Research Institute

Investigation Of Hippocampal Substructures In Focal Temporal Lobe Epilepsy With And Without Hippocampal Sclerosis At 7t., Brendan G Santyr, Maged Goubran, Jonathan C Lau, Benjamin Y M Kwan, Fateme Salehi, Donald H Lee, Seyed M Mirsattari, Jorge G Burneo, David A Steven, Andrew G Parrent, Sandrine De Ribaupierre, Robert R Hammond, Terry M Peters, Ali R Khan

Robarts Imaging Publications

PURPOSE: To provide a more detailed investigation of hippocampal subfields using 7T magnetic resonance imaging (MRI) for the identification of hippocampal sclerosis in temporal lobe epilepsy (TLE).

MATERIALS AND METHODS: Patients (n = 13) with drug-resistant TLE previously identified by conventional imaging as having hippocampal sclerosis (HS) or not (nine without HS, four HS) and 20 age-matched healthy controls were scanned and compared using a 7T MRI protocol. Using a manual segmentation scheme to delineate hippocampal subfields, subfield-specific volume changes and apparent transverse relaxation rate ( R2*) were studied between the two groups. In addition, qualitative assessment at 7T and …


Europium(Ii)-Containing Complexes For Responsive Magnetic Resonance Imaging, Levi Alexander Ekanger 2016 Wayne State University

Europium(Ii)-Containing Complexes For Responsive Magnetic Resonance Imaging, Levi Alexander Ekanger

Wayne State University Dissertations

The research projects described in this dissertation are focused on studying the oxidation of EuII-containing complexes within the context of responsive MRI. Prior to this research, EuII had not been explored within the context of oxidation-responsive MRI nor had the use of this ion been reported in vivo. The results of these studies enable predictions about the oxidation-responsive behavior of EuII-containing complexes in vitro and in vivo.

The EuII-containing cryptate 1.33 was used to evaluate EuII-based positive contrast enhancement after intravenous, intraperitoneal, and subcutaneous injections. The transitory behavior of the positive contrast enhancement correlated with reported levels of oxygenation and …


X-Ray Beam Characteristics And Radiation Dose Deposition To Soft Tissue From Fluoroscopic X-Ray Beams Incorporating Copper Filtration, Kevin Arthur Wunderle 2016 Wayne State University

X-Ray Beam Characteristics And Radiation Dose Deposition To Soft Tissue From Fluoroscopic X-Ray Beams Incorporating Copper Filtration, Kevin Arthur Wunderle

Wayne State University Dissertations

Purpose: This work investigated several topics related to dosimetry in soft tissue from fluoroscopic X-ray beams; first, it investigated the X-ray beam spectra and air kerma rates available for clinical use on state-of-the-art fluoroscopes using spectral (copper [Cu]) filtration; second, it investigated the fluoroscopic X-ray beam characteristics of first half-value layer (HVL), second HVL, homogeneity coefficients (HCs), and backscatter factors (BSFs) across the full range of available beam qualities; and third, it investigated the energy dependence of kerma-area-product (KAP)-meters measuring the radiation output of the fluoroscope. Materials and Methods: A state-of-the-art Siemens Artis Zee fluoroscope was operated in the service …


Categorizing Fetal Heart Rate Variability With And Without Visual Aids, Amanda J. Ashdown, Mark W. Scerbo, Lee A. Belfore II, Stephen S. Davis, Alfred Z. Abuhamad 2016 Old Dominion University

Categorizing Fetal Heart Rate Variability With And Without Visual Aids, Amanda J. Ashdown, Mark W. Scerbo, Lee A. Belfore Ii, Stephen S. Davis, Alfred Z. Abuhamad

Psychology Faculty Publications

Objective This study examined the ability of clinicians to correctly categorize images of fetal heart rate (FHR) variability with and without the use of exemplars.

Study Design A sample of 33 labor and delivery clinicians inspected static FHR images and categorized them into one of four categories defined by the National Institute of Child Health and Human Development (NICHD) based on the amount of variability within absent, minimal, moderate, or marked ranges. Participants took part in three conditions: two in which they used exemplars representing FHR variability near the center or near the boundaries of each range, and a third …


Quantitative Assessment Of Brain Iron Content As A Function Of Age Using Magnetic Resonance Imaging, Kiarash Ghassaban 2016 Wayne State University

Quantitative Assessment Of Brain Iron Content As A Function Of Age Using Magnetic Resonance Imaging, Kiarash Ghassaban

Wayne State University Theses

As the most abundant transition metal in the brain, iron is known to play a key role in a variety of functional and cellular processes. Recent in vivo and post-mortem studies have shown that the levels of iron deposition in the brain, particularly in deep gray matter nuclei, vary as a function of age. On the other hand, elevated iron has also been associated with some neurodegenerative diseases such as Multiple Sclerosis (MS) and Parkinson’s disease (PD) among others.

Magnetic Resonance Imaging (MRI) is a widely used non-invasive and non-ionizing imaging modality which is sensitive to magnetic properties of materials …


Toward Magnetic Resonance Only Treatment Planning: Distortion Mitigation And Image-Guided Radiation Therapy Validation, Ryan Glen Price 2016 Wayne State University

Toward Magnetic Resonance Only Treatment Planning: Distortion Mitigation And Image-Guided Radiation Therapy Validation, Ryan Glen Price

Wayne State University Dissertations

While MR-only treatment planning has shown promise, there are still several well-known challenges that are currently limiting widespread clinical implementation.

Firstly, MR images are affected by both patient-induced and system-level geometric distortions that can significantly degrade treatment planning accuracy. . In addition, the availability of comprehensive distortion analysis software is currently limited. Also while many groups have been working toward a synthetic CT solution, further study is needed on the implementation of synCTs as the reference datasets for linac-based image-guided radiation therapy (IGRT) to help determine their robustness in an MR-only workflow.

A 36×43×2 cm3 phantom with 255 known landmarks …


Biventricular Finite Element Modeling And Quantification Of 3d Langragian Strains And Torsion Using Dense Mri, Zhanqiu Liu 2016 University of Kentucky

Biventricular Finite Element Modeling And Quantification Of 3d Langragian Strains And Torsion Using Dense Mri, Zhanqiu Liu

Theses and Dissertations--Mechanical and Aerospace Engineering

Statistical data suggests that increased use of evidence-based medical therapies has largely contributed to the decrease in American death rate caused by heart disease. And my studies are about two applications of magnetic resonance imaging (MRI) as a non-invasive approach in evidence-based health care research. In my first study, the achievement of a pulmonary valve replacement surgery was assessed on a patient with tetralogy of Fallot (TOF). In order to evaluate the remodeling of right ventricle, two biventricular finite element models were built up for pre-surgical images and post-surgical images. In my second study, 3D Lagrangian strains and torsion in …


A Software Application For Cardiac-Gated Computerized Tomography Scanning, Stephen Caldwell, Trevor Engelsman 2016 University of Akron

A Software Application For Cardiac-Gated Computerized Tomography Scanning, Stephen Caldwell, Trevor Engelsman

Williams Honors College, Honors Research Projects

Computerized tomography (CT) scans are a common clinical imaging procedure used worldwide. Operating in the X-Ray spectrum, these machines rotate scanners around a stationary body in order to compile two-dimensional images into a unified three-dimensional image. With adjustment to scan frequency and intensity, internal features such as muscles, organs, and tendons can easily be viewed. However, the heart has long evaded CT use due to its near-constant motion. Recently, cardiac-gated scans have entered the market as a technique to image the heart at a specific moment in time when it is nearly still - the quiescent period. Occurring during rapid …


Effects Of Scattering And Absorption On Laser Speckle Contrast Imaging, Kosar Khaksari 2016 Michigan Technological University

Effects Of Scattering And Absorption On Laser Speckle Contrast Imaging, Kosar Khaksari

Dissertations, Master's Theses and Master's Reports

Laser Speckle Contrast Imaging (LSCI) is a real-time, non-invasive method in used to investigate blood flow and perfusion in biological tissues with high temporal and spatial resolution. A reduction in speckle contrast due to particle motion is the primary contrast mechanism in LSCI. Motion results in speckle fluctuations in time and reduces the contrast over a given camera integration period. There are a variety of parameters that effect contrast besides motion. The optical properties of the scattering medium are one of the parameters effecting LSCI values. Changes in blood hematocrit levels manifest as changes in optical properties. In this work, …


Design And Development Of Optical Elastography Setup, Abhinav Madhavachandran 2016 Michigan Technological University

Design And Development Of Optical Elastography Setup, Abhinav Madhavachandran

Dissertations, Master's Theses and Master's Reports

The mechanical properties of the skin are an indication of its physiological condition. The properties can serve as potential information for dermatologists for diagnosis and qualitative assessment. Elastography is a medical imaging modality developed to extract the elastic properties of a tissue by application of an external force. Optical elastography is a technique of elastography which uses laser speckle tracking to study the elastic properties of several soft tissue including skin.

This work is aimed at developing an optical elastography setup that can study the elastic properties of skin. The setup includes an imaging system and a force-application system controlled …


Recent Advances In Optical Spectroscopic And Imaging Methods For Medicine And Biology, Yu Shang, Zhiyu Qian, Rickson C. Mesquita, Mathieu Dehaes 2016 University of Kentucky

Recent Advances In Optical Spectroscopic And Imaging Methods For Medicine And Biology, Yu Shang, Zhiyu Qian, Rickson C. Mesquita, Mathieu Dehaes

Biomedical Engineering Faculty Publications

No abstract provided.


Feasibility Of Using Raman-Based Techniques For Breast Cancer Detection, Sara Mollamohammada 2015 University of Nebraska-Lincoln

Feasibility Of Using Raman-Based Techniques For Breast Cancer Detection, Sara Mollamohammada

Department of Civil and Environmental Engineering: Dissertations, Theses, and Student Research

Breast cancer is one of the common types of cancer among women all over the world. Early diagnosis is an effective way that improve the treatment process and gives the patients a better chance of survival. Many of the patients infected by breast cancer choose breast conservation surgery (BCS). However, some of those will be subjected to mastectomy, and many will have tumor recurrence as there is no precise technique to show the tumor margins. Raman-based methods are powerful techniques with potential to rapidly differentiate normal from tumor tissues and provides a solution to detect tumor margin. This is because …


Improved Sensitivity To Fluorescence For Cancer Detection In Wide-Field Image-Guided Neurosurgery, Michael Jermyn, Yoann Gosselin, Pablo A. Valdes, Mira Sibai, Kolbein Kolste 2015 Polytechnique Montreal

Improved Sensitivity To Fluorescence For Cancer Detection In Wide-Field Image-Guided Neurosurgery, Michael Jermyn, Yoann Gosselin, Pablo A. Valdes, Mira Sibai, Kolbein Kolste

Dartmouth Scholarship

In glioma surgery, Protoporphyrin IX (PpIX) fluorescence may identify residual tumor that could be resected while minimizing damage to normal brain. We demonstrate that improved sensitivity for wide-field spectroscopic fluorescence imaging is achieved with minimal disruption to the neurosurgical workflow using an electron-multiplying charge-coupled device (EMCCD) relative to a state-of-the-art CMOS system. In phantom experiments the EMCCD system can detect at least two orders-of-magnitude lower PpIX. Ex vivo tissue imaging on a rat glioma model demonstrates improved fluorescence contrast compared with neurosurgical fluorescence microscope technology, and the fluorescence detection is confirmed with measurements from a clinically-validated spectroscopic probe. Greater PpIX …


Calibration And Optimization Of 3d Digital Breast Tomosynthesis Guided Near Infrared Spectral Tomography, Kelly E. Michaelsen, Venkataramanan Krishnaswamy, Linxi Shi, Srinivasan Vedantham, Steven Poplack, Andrew Karellas, Brian Pogue, Keith Paulsen 2015 Dartmouth College

Calibration And Optimization Of 3d Digital Breast Tomosynthesis Guided Near Infrared Spectral Tomography, Kelly E. Michaelsen, Venkataramanan Krishnaswamy, Linxi Shi, Srinivasan Vedantham, Steven Poplack, Andrew Karellas, Brian Pogue, Keith Paulsen

Dartmouth Scholarship

Calibration of a three-dimensional multimodal digital breast tomosynthesis (DBT) x-ray and non-fiber based near infrared spectral tomography (NIRST) system is challenging but essential for clinical studies. Phantom imaging results yielded linear contrast recovery of total hemoglobin (HbT) concentration for cylindrical inclusions of 15 mm, 10 mm and 7 mm with a 3.5% decrease in the HbT estimate for each 1 cm increase in inclusion depth. A clinical exam of a patient's breast containing both benign and malignant lesions was successfully imaged, with greater HbT was found in the malignancy relative to the benign abnormality and fibroglandular regions (11 μM vs. …


Digital Commons powered by bepress