A Nocsae Drop Test/ 3d-Fem Study On The Relationship Between Kinematic Response Of The Head, Head Impact Contact Pressure (Hicp) And Kinetic Response Of The Brain To Delineate The Risk Of Traumatic Brain Injuries (Tbi).,
2016
Michigan Technological University
A Nocsae Drop Test/ 3d-Fem Study On The Relationship Between Kinematic Response Of The Head, Head Impact Contact Pressure (Hicp) And Kinetic Response Of The Brain To Delineate The Risk Of Traumatic Brain Injuries (Tbi)., Raghavendra Krishna Tej Bhamidipati
Dissertations, Master's Theses and Master's Reports
How many times have you seen a person slip and fall down and had a good laugh about it? How many times we slip and fall down on the floor and got up and walked away thinking everything is normal? Probably we might wonder “Are drops which occur at a small height dangerous?” Yes, they can be. Brain injuries are main reason for the fatality in youth [1], and low level falls are one of the most neglected and understated injuries.
The main objective of this study is to study the response of the brain for low level falls from …
Finite Element Modeling Of Active And Passive Behavior Of The Human Tibialis Anterior: A Preliminary Approach,
2016
Michigan Technological University
Finite Element Modeling Of Active And Passive Behavior Of The Human Tibialis Anterior: A Preliminary Approach, David Joda
Dissertations, Master's Theses and Master's Reports
This research project serves as exploratory work in the field of computational human biomechanics. A connection between muscular force and intramuscular pressure (IMP) has been uncovered that could prove invaluable in medical diagnostics as a method to circumvent the use of electromyography.
Preliminary finite element simulations were conducted to model the human tibialis anterior muscle in passive lengthening and active contraction. These simulations, totaling over 50 unique runs, utilized a novel constitutive model developed within the IMP research group. Volumetric strain, reaction forces, and pressure gradients were compared to data acquired from ongoing in vivo human experiments. A mechanism for …
Characterization Of Piezoelectric Device For Implanted Pacemaker Energy Harvesting,
2016
Cork Institute of Technology, Bishopstown, Cork, Ireland
Characterization Of Piezoelectric Device For Implanted Pacemaker Energy Harvesting, Sunny Jay, Manuel Caballero, William Quinn, John Barrett, Martin Hill
Conference Papers
Novel implanted cardiac pacemakers that are powered by energy harvesters driven by the cardiac motion and have a 40 year lifetime are currently under development. To satisfy space constraints and energy requirements of the device, silicon-based MEMS energy harvesters are being developed in the EU project (MANpower). Such MEMS harvesters for vibration frequencies below 50 Hz have not been widely reported. In this paper, an analytical model and a 3D finite element model (FEM) to predict displacement and open circuit voltage, validated through experimental analysis using an off-the-shelf low frequency energy harvester, are presented. The harvester was excited through constant …
In-Shoe Plantar Pressure System To Investigate Ground Reaction Force Using Android Platform,
2016
Virginia Commonwealth University
In-Shoe Plantar Pressure System To Investigate Ground Reaction Force Using Android Platform, Ahmed A. Mostfa
Theses and Dissertations
Human footwear is not yet designed to optimally relieve pressure on the heel of the foot. Proper foot pressure assessment requires personal training and measurements by specialized machinery. This research aims to investigate and hypothesize about Preferred Transition Speed (PTS) and to classify the gait phase of explicit variances in walking patterns between different subjects. An in-shoe wearable pressure system using Android application was developed to investigate walking patterns and collect data on Activities of Daily Living (ADL). In-shoe circuitry used Flexi-Force A201 sensors placed at three major areas: heel contact, 1st metatarsal, and 5th metatarsal with a PIC16F688 microcontroller …
Finite Element And Probabilistic Analysis Of Soft Tissue Structures Of The Human Lumbar Spine,
2016
University of Denver
Finite Element And Probabilistic Analysis Of Soft Tissue Structures Of The Human Lumbar Spine, Dana Joseph Coombs
Electronic Theses and Dissertations
Human lumbar spine mechanics are influenced by soft tissue structures. Understanding and properly modeling these structures can help determine pathology, treatment, and implant design and performance. Finite element models of the L4-L5 level of the lumbar spine are often used, which include a representation of the intervertebral disc and spinal ligaments. Validation of these models are typically based on torque rotation data from a single subject or the models use average properties reported in literature. However, experimental testing reports variation up to 40% in ligament stiffness and even greater variability for annulus fibrosis properties. Probabilistic approaches enable consideration of the …
Statistical Modeling To Investigate Anatomy And Function Of The Knee,
2016
University of Denver
Statistical Modeling To Investigate Anatomy And Function Of The Knee, Lowell Matthew Smoger
Electronic Theses and Dissertations
The natural knee is a hinge joint with significant functional requirements during activities of daily living; as a result, acute and chronic injuries can occur. Pathologies are influenced by joint anatomy and may include patellar maltracking, cartilage degeneration (e.g. osteoarthritis), or acute injuries such as meniscal or ligamentous tears. Population variability makes broadly applicable conclusions about etiology of these conditions from small-scale investigations challenging. The work presented in this dissertation is a demonstration of statistical modeling approaches to evaluate population variability in anatomy of the knee and function of its tibiofemoral (TF) and patellofemoral (PF) joints. Three-dimensional (3D) computational models …
Development Of A Design Tool For Biologically Inspired Fault Adaptive Design By Strategy Mapping,
2015
University of Arkansas, Fayetteville
Development Of A Design Tool For Biologically Inspired Fault Adaptive Design By Strategy Mapping, Nicholas Steven Huisman
Graduate Theses and Dissertations
A design tool for Biologically Inspired Fault Adaption that utilizes the concept of strategy mapping was developed and the development process and testing is presented in this paper. The concept of strategy mapping is derived primarily from the field of military theory and supposes that for any given specific problem, that there exists a specific solution for, a single strategy can be identified for that solution/problem combination. This strategy, when applied to the specific problem yields the specific solution. This specific solution is referred to as the “tactics” of the strategy. The strategy can also be directly applied to a …
Carbon Articulating Backpack Spine,
2015
California Polytechnic State University - San Luis Obispo
Carbon Articulating Backpack Spine, Salvatore Monforte Iii, Darci Lawrence, Savan Patel
Mechanical Engineering
In the field, firefighters and Urban Search and Rescue (USAR) personnel need to transport variable loads efficiently, safely, and comfortably while simultaneously performing certain physical tasks. Current models of external and internal framed backpacks distribute the load of a pack efficiently, but do not allow for the natural movement of the wearer. Wolfpack Gear, Inc. proposed the need for a system which both effectively carries a load and allows for the unhindered natural movement of the user. The goal of this project was to design, build, and test an articulating backpack support system. The first stage of the project comprised …
Lumped Parameter Model For A Self Powered Fontan Palliation Of The Hypoplastic Left Heart Syndrome,
2015
Embry-Riddle Aeronautical University
Lumped Parameter Model For A Self Powered Fontan Palliation Of The Hypoplastic Left Heart Syndrome, Jang Ho Park
Doctoral Dissertations and Master's Theses
Out of all newborn infants with congenital heart disease (CHD), 8% have a single functioning ventricle. The Fontan surgical procedure, where the superior and inferior venous returns are connected directly to the pulmonary arteries to allow the single functioning ventricle to perfuse the systemic circulation, has been around for decades, yet the patients who undergo this operation suffer from chronic illnesses and their survivability is less than 50% by adulthood [1-10]. Some suggest that the Fontan operation can be improved by implanting a synthetic pump. However, synthetic pumps also present some complications due to mechanical failure, risk of stroke, and …
Biomechanical Investigation Of Elite Place-Kicking,
2015
University of Nebraska-Lincoln
Biomechanical Investigation Of Elite Place-Kicking, Chase M. Pfeifer
Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research
Many studies aim to understand the fundamentals of kicking commonly displayed by soccer players [4,6,10,16,17,18,24,25,28,29,30,34,36,38,40]. Of those studies, most are limited to a two-dimensional (2D) analysis using high-speed cameras for position tracking or utilizing electromyography to observe the activity of select muscles [4,6,18,25,29,36]. The few studies that investigate kicking using a three-dimensional (3D) model are limited in their position tracking capabilities and focus mainly on joint flexion potentials and foot speed.
This dissertation is a comprehensive biomechanical analysis (kinematic and EMG) of the field-goal place-kicking techniques of four elite kickers in American football. Data were compared and contrasted with ball …
The Research, Design And Implementation Of A Remotely Operated Bioreactor With Incubation System For The Purpose Of A 3d Cell Line Growth,
2015
University of Alabama in Huntsville
The Research, Design And Implementation Of A Remotely Operated Bioreactor With Incubation System For The Purpose Of A 3d Cell Line Growth, Steven Doyle, John Helms, Ryan Longchamps, Azita Amiri
Von Braun Symposium Student Posters
No abstract provided.
Health Condition Monitoring And Fault-Tolerant Operation Of Adjustable Speed Drives,
2015
Marquette University
Health Condition Monitoring And Fault-Tolerant Operation Of Adjustable Speed Drives, Jiangbiao He
Dissertations (1934 -)
Adjustable speed drives (ASDs) have been extensively used in industrial applications over the past few decades because of their benefits of energy saving and control flexibilities. However, the wider penetration of ASD systems into industrial applications is hindered by the lack of health monitoring and fault-tolerant operation techniques, especially in safety-critical applications. In this dissertation, a comprehensive portfolio of health condition monitoring and fault-tolerant operation strategies is developed and implemented for multilevel neutral-point-clamped (NPC) power converters in ASDs. Simulations and experiments show that these techniques can improve power cycling lifetime of power transistors, on-line diagnosis of switch faults, and fault-tolerant …
Optimization Of Blalock-Taussig Shunt And Anastomotic Geometry For Vascular Access Fistula Using A Genetic Algorithm,
2015
Washington University in St. Louis
Optimization Of Blalock-Taussig Shunt And Anastomotic Geometry For Vascular Access Fistula Using A Genetic Algorithm, Guangyu Bao
McKelvey School of Engineering Graduate Student Theses & Dissertations
Blalock-Taussig (BT) shunts are used for defects that affect the flow of blood from the right ventricle, through the pulmonary artery, and to the lungs. Arteriovenous (AV) fistula is one type of vascular access which is a surgically created vein used to remove and return blood during hemodialysis. Plastic grafts used in the above two reconstructions may result in areas of non-physiologic flow in the grafts leading to risk of stenosis (blocked area) and thrombosis, which is the single major cause for access morbidity. The focus of this thesis is to study BT shunts and anastomoses models using Computational Fluid …
Indentation Probing Of In Vitro Bovine Articular Cartilage: Effects On Chondrocyte Viability And Tissue Biomechanics,
2015
Purdue University
Indentation Probing Of In Vitro Bovine Articular Cartilage: Effects On Chondrocyte Viability And Tissue Biomechanics, Pablo F. Argote, Alan Poon, Xin Xu Ph.D, Corey P. Neu Ph.D.
The Summer Undergraduate Research Fellowship (SURF) Symposium
Osteoarthritis (OA) consists of a degenerative disease on articular cartilage, which is prone to excessive mechanical loading and frictional resistance that leads to the wear and tear of the tissue. These factors result in the progressive and incurable disease that affects millions of people worldwide. The goal is to characterize chondrocyte viability and the in vitro biomechanical properties of articular cartilage in two confined indentation studies. One study looks at the chondrocyte viability over seven days. The second compares the immediate effects of strain rates on chondrocyte viability and tissue biomechanics. Bovine cartilage explants are harvested, cultured, and then 40% …
Cell-Matrix Interactions During En Masse Cell Migration,
2015
School of Mechanical Engineering, Purdue University, West Lafayette, IN
Cell-Matrix Interactions During En Masse Cell Migration, Meng Zhuang, Altug Ozcelikkale, Bumsoo Han
The Summer Undergraduate Research Fellowship (SURF) Symposium
Extended wound care, including prolonged treatment of burn injuries, acute and chronic wounds, is a significant source of patient discomfort and financial burden to public healthcare programs. Both accelerated healing and prevention of scar formation are highly desired but remain to be challenging to achieve. This is primary due to limited understanding of interactions between cells and the surrounding extracellular matrix (ECM) during wound healing. Particularly, collective migration of fibroblasts through provisional matrix, so called en masse migration, is one of these interactions that play a critical role in later stages of granulation tissue formation and wound closure. In addition …
Development Of A Shape Memory Polymer Soft Microgripper,
2015
Purdue University
Development Of A Shape Memory Polymer Soft Microgripper, Marshall Tatro, David J. Cappelleri, Wuming Jing
The Summer Undergraduate Research Fellowship (SURF) Symposium
The ability to control microrobots by means of magnetic fields has become of increasing interest to researchers. These robots’ ability to reach places tethered microrobots otherwise could not leads to many possible applications in the body, such as delivering drugs to targeted locations and performing biopsies. This study shows the use of shape memory polymer (SMP) to wirelessly actuate a microgripper to be used by a controllable microrobot to achieve these functions. Many smart materials were analyzed in order to find the material that most effectively would accomplish wirelessly gripping, manipulating, and releasing a microobject. Multiple microgripper designs were designed, …
Design And Implementation Of An Interactive Animatronic System For Guest Response Analysis,
2015
Georgia Southern University
Design And Implementation Of An Interactive Animatronic System For Guest Response Analysis, Brian Burns
Phi Kappa Phi Research Symposium (Archived)
In theme park based entertainment applications, there is a need for interactive, autonomous animatronic systems to create engaging and compelling experiences for the guests. The animatronic figures must identify the guests and recognize their status in dynamic interactions for enhanced acceptance and effectiveness as socially interactive agents, in the general framework of human-robot interactions. The design and implementation of an interactive, autonomous animatronic system in form of a tabletop dragon, Kronos, and the comparisons of guest responses in its passive and interactive modes are presented in this work. The dragon capabilities include a four degrees-of-freedom head, moving wings, tail, jaw, …
A Finite Element Analysis Of Tibial Stem Geometry For Total Knee Replacements,
2015
California Polytechnic State University, San Luis Obispo
A Finite Element Analysis Of Tibial Stem Geometry For Total Knee Replacements, Aaron Isidro Bautista
Master's Theses
The purpose of this study was to investigate the influence of tibial stem geometry on stress shielding of the tibia for patients with a total knee replacement. Finite element analysis was used to study different tibial stem geometry types, as well as a vast array of different geometric sizes. Both a peg and stem type geometry were analyzed and compared in order to determine what type geometry causes the least amount of stress shielding. A static loading condition with a dynamic loading factor of three was used for the system and the stress responses were analyzed at regions of interest …
Sapien3 Comb Stitch Improvement For Edwards Lifesciences,
2015
California Polytechnic State University - San Luis Obispo
Sapien3 Comb Stitch Improvement For Edwards Lifesciences, William Harley, Thomas Pluschkell, John Mctigue, Garrett Reed
Mechanical Engineering
The complete senior project report was submitted to the project advisor and sponsor. The results of this project are of a confidential nature and will not be published at this time.
Development And Validation Of A Tibiofemoral Joint Finite Element Model And Subsequent Gait Analysis Of Intact Acl And Acl Deficient Individuals,
2015
California Polytechnic State University, San Luis Obispo
Development And Validation Of A Tibiofemoral Joint Finite Element Model And Subsequent Gait Analysis Of Intact Acl And Acl Deficient Individuals, Nicholas Czapla
Master's Theses
Osteoarthritis (OA) is a degenerative condition of articular cartilage that affects more than 25 million people in the US. Joint injuries, like anterior cruciate ligament (ACL) tears, can lead to OA due to a change in articular cartilage loading. Gait analysis combined with knee joint finite element modeling (FEM) has been used to predict the articular cartilage loading. To predict the change of articular cartilage loading during gait due to various ACL injuries, a tibiofemoral FEM was developed from magnetic resonance images (MRIs) of a 33 year male, with no prior history of knee injuries. The FEM was validated for …