Wearing Complete Dental Prostheses - Effects On Perioral Morphology,
2016
Friedrich Schiller University of Jena
Wearing Complete Dental Prostheses - Effects On Perioral Morphology, Gregor F. Raschke, Philipp Eberl, Geoffrey A. Thompson, Arndt Guentsch, Andre Peisker, Stefan Schultze-Mosgau, Marta Gomez-Dammeier, Gabriel Djedovic, Ulrich M. Rieger, Florian Beuer
School of Dentistry Faculty Research and Publications
Background: To adequately perform rehabilitation of edentulous patients by a complete removable dental prosthesis (CRDP) is from basic interest to dentists to understand the morphologic changes caused by re-establishment of a physiologic jaw relationship. Anthropometric analyses of standardized frontal view and profile photographs may help elucidate such changes. Material and Methods: Photographs of 31 edentulous patients were compared in relaxed lip closure and after insertion of a CRDP in stable occlusion. 2232 anthropometric distances were raised. Eighteen anthropometric indices reflecting the perioral morphology and its integration in the vertical facial harmony were investigated. Results: The intercanthal – mouth width index …
Objective Evaluation Of Clinical Shade-Matching Outcomes.,
2016
University of Louisville
Objective Evaluation Of Clinical Shade-Matching Outcomes., Erin Ballard
Electronic Theses and Dissertations
The purpose of this study was to objectively evaluate shade-matching outcomes within an academic institution. Using the Spectrophotometer, E was calculated between the reference shade: restoration shade () and restoration shade: prescription shade (). The t-test was used to determine if E maintained clinical acceptance at E: 3.7. Satisfaction with shade-match and need for objective measurement were surveyed using a Five Point Likert Scale. Correlational relationships were assessed via Pearson Correlation. Mean E values were above the acceptance value (pppp
Evaluation Of Die Trim Morphology Made By Cad/Cam Technology,
2016
Marquette University
Evaluation Of Die Trim Morphology Made By Cad/Cam Technology, Pratiksha Agrawal
Master's Theses (2009 -)
Purpose: The purpose of this vitro study was to evaluate the accuracy of the morphology of digitally trimmed dies in comparison with the subgingival contour of a prepared tooth to be restored with a single crown. Materials and Methods: 20 human extracted teeth, 10 incisors and 10 molars were disinfected, mounted on dentoforms. The teeth were prepared for a single all ceramic restoration. Digital impressions of the preparations were made using the 3M Lava COS. With the data, the SLA models were fabricated with removable dies. The prepared tooth and the corresponding dies were then compared with the Rhino software. …
Comparison Of Retention Between Milled And Conventional Denture Bases: A Clinical Study,
2016
Loma Linda University
Comparison Of Retention Between Milled And Conventional Denture Bases: A Clinical Study, Abdulaziz Abdullah Alhelal
Loma Linda University Electronic Theses, Dissertations & Projects
The advancement in dental material technology led to the improvement in the fabrication method of PMMA denture bases. Denture base adaptation can be influenced by the amount of polymerization shrinkage that occurs during the processing method of fabrication. CAD/CAM dentures milled from prepolymerized PMMA acrylic resin blocks theoretically have reduced or no polymerization shrinkage. There have been no clinical studies, to date, that have compared retention values between milled and conventionally processed denture bases. Therefore, the purpose of this study clinical study was to compare the retention values between conventional heat polymerized and digital milled maxillary denture bases.
Twenty patients …
Effects Of Microwave Irradiation On The Dimensional Stability Of Complete Denture Bases,
2016
Loma Linda University
Effects Of Microwave Irradiation On The Dimensional Stability Of Complete Denture Bases, Miguel Pappaterra
Loma Linda University Electronic Theses, Dissertations & Projects
Introduction: Maintenance for complete dentures is a role that must be undertaken by the patient. It has been determined that two minutes of microwave irradiation at 650 Watts provides denture disinfection, and three minutes provide sterilization32,34. There is insufficient data on how this practice affects the long term dimensional stability of commonly used complete denture bases in the United States. Purpose: The purpose of this study was to perform an in-vitro investigation, testing and comparing the effects of microwave irradiation on the dimensional stability of three types of complete denture bases. Materials and Methods: An edentulous master cast with reference …
Comparison Of Digital Scanning And Polyvinyl Siloxane Impression Techniques By Dmd Students : Instructional Efficiency And Attitudes Toward Technology.,
2015
University of Louisville
Comparison Of Digital Scanning And Polyvinyl Siloxane Impression Techniques By Dmd Students : Instructional Efficiency And Attitudes Toward Technology., Alexander M. Marti
Electronic Theses and Dissertations
The aim of this research was compare the ability of dental students to learn an digital scanner (3M LAVA) and material-based (PVS) impression techniques and to determine attitudes and preferences towards each. D2 dental students (n=25) were recruited and instructed on the use of 3M LAVA and PVS techniques using three pedagogic methods: 1) video lecture (P1), 2) investigator-led demonstration (P2), and 3) independent clinical exercise (P3). The amount of time for each pedagogic method was measured, averaged (± s.d.) and compared using Wilcoxon Signed-Ranks tests. A pre- and post-test was administered assessing their attitudes towards both techniques using a …
Comparative Study Of Retention Of Palate-Less Versus Complete Palatal Coverage Dentures Fitted With Zirconia Mucosal Inserts,
2015
The British University in Egypt
Comparative Study Of Retention Of Palate-Less Versus Complete Palatal Coverage Dentures Fitted With Zirconia Mucosal Inserts, Fardos N. Rizk
Dentistry
Objective: The purpose of this study is to compare the retention of palate-less versus complete palatal coverage dentures fitted with zirconia mucosal inserts. Materials and Methods: Fourteen male patients received upper complete dentures fitted with zirconia mucosal inserts. Half of the dentures were fabricated with complete palatal coverage (Group I) and the other half was palate-less (Group II).Retention was measured for all patients using force measurement gauge through six months follow-up period. Results: Both groups showed increase in denture retention through the follow-up period however, dentures with complete palatal coverage (Group 1) showed higher mean values of retention compared to …
Are Bone Turnover Markers And Vitamin D Levels Associated With Frequency Of Complete Denture Relines?,
2015
Loma Linda University
Are Bone Turnover Markers And Vitamin D Levels Associated With Frequency Of Complete Denture Relines?, Shweta Puri
Loma Linda University Electronic Theses, Dissertations & Projects
PURPOSE: To compare groups of subjects with varying frequencies of complete denture relines in terms of their bone turnover markers; C-terminal Telopeptide (C-Tx), Osteocalcin (OCN) and Vitamin D (25 OH-Vit D) levels to determine the presence of and the degree of association between them.
METHODS: This study was designed as a cross-sectional study wherein a retrospective chart review of three hundred twenty four edentulous subjects with history of complete denture use for at least a year was performed to determine history and frequency of their complete denture relines. A total of 100 patients were enrolled. After consent was obtained, each …
Effect Of Diamond Bur And Root Canal Irrigants On Retention Of Fiber Posts,
2015
Loma Linda University
Effect Of Diamond Bur And Root Canal Irrigants On Retention Of Fiber Posts, Rami Jekki
Loma Linda University Electronic Theses, Dissertations & Projects
Esthetic glass fiber-reinforced posts are being used more often. The most commonly reported complication associated with these posts is debonding. Dentine conditioning with solutions such as EDTA or MTAD results in removal of smear layer and might improve the retention of posts to root canal dentin. Therefore, the purpose of this study was to investigate the effect of cleansing the post space with MTAD or EDTA on the bond strength of glass fiber-reinforced posts, when a diamond roughening instrument is used prior to cementation with self-adhesive resin cement. Forty-five (n=15) extracted human premolar teeth were sectioned at the cemento-enamel junction …
Comparison Of Maxillary Anterior Teeth Width To Facial Dimensions Among Three Races,
2015
Loma Linda University
Comparison Of Maxillary Anterior Teeth Width To Facial Dimensions Among Three Races, Ewa Parciak
Loma Linda University Electronic Theses, Dissertations & Projects
Dental esthetics and tooth proportions have become increasingly relevant in dentistry, as the cosmetic demands of patients increase. Determining the appropriate esthetic dimensions of the maxillary anterior teeth is an important aspect in fixed and removable prosthodontics. The proportion of facial structures and the relationship between facial measurements and natural teeth could provide additional guidance in selecting denture teeth as well as in determining ideal teeth size for fixed restorations. There have been many publications on this topic, however, the subjects in these studies have been mostly selected from the Caucasian race. With the increasing diversity of the American population …
Comparative Study Of Implant Stability And Bone Height Changes Among Different Implant Designs Retaining Partial Overdenture,
2015
The British University in Egypt
Comparative Study Of Implant Stability And Bone Height Changes Among Different Implant Designs Retaining Partial Overdenture, Fardos N. Rizk
Dentistry
Objective: This study was conducted to assess the primary stability of Trabecular Metal Dental Implant and Tapered Screw Vent Implant to determine the appropriate time for their loading by lower partial overdenture and to follow up for one year the changes in implant stability and crestal bone height surrounding the implant after loading it. Materials and Methods: The study was performed on ten lower Kennedy class I partially edentulous male patients. Each patient received one implant at the second molar area in each side of the ridge, where Trabecular Metal Dental Implant was inserted in the left side of the …
Osseointegration Of Wrapped Dental Implants In Rabbits,
2015
Virginia Commonwealth University
Osseointegration Of Wrapped Dental Implants In Rabbits, Alex Whitehead
AUCTUS: The Journal of Undergraduate Research and Creative Scholarship
Edentulous patients (those lacking teeth) require one of two approaches to augmentation: inserting a vertical bone graft, or subperiosteally anchoring a device on which an implant can be attached. Bone grafts have had unpredictable results and can undergo resorption over time, compromising implant stability and success. As of the subperiosteal approach, current materials have not proven to directly integrate with the bone, in a process termed osseointegration. Therefore, we used additive manufacturing to create a Ti6Al4V alloy surface with a specific roughness to determine if it would be osseoinductive in a challenging rabbit model over six weeks.
Restorative Characteristics Of Intrapulpally Cracked Teeth,
2015
VCU
Restorative Characteristics Of Intrapulpally Cracked Teeth, Charles M. Beavers
Theses and Dissertations
Cracked teeth have long presented a diagnostic challenge. Previous investigators have considered possible predictive factors, many of which revolve around the tooth’s restorative characteristics. Few have investigated the restorative status of teeth with cracks extending into the pulp chamber. The purpose of this investigation was to determine the prevalence of the different types of restorations present in intrapulpally cracked teeth and determine any other restorative factors that may aid in predicting the presence or extent of an intrapulpal crack. Intrapulpally cracked molars requiring endodontic therapy at the VCU Graduate Endodontic Practice were included in this study. For each tooth, the …
The Effect Of Root Canal Cleansing On The Retention Of Glass Fiber-Reinforced Posts,
2014
Loma Linda University
The Effect Of Root Canal Cleansing On The Retention Of Glass Fiber-Reinforced Posts, Faisal Dhaifallah Al-Qarni
Loma Linda University Electronic Theses, Dissertations & Projects
Esthetic glass fiber-reinforced posts are being used more often. The most commonly reported complication associated with these posts is debonding. Dentine conditioning with solutions such as EDTA or MTAD results in removal of smear layer and might improve the retention of posts to root canal dentin. Therefore, the purpose of this study was to investigate the effect of cleansing the post space with MTAD or EDTA on the bond strength of glass fiber-reinforced posts, when cemented with self-adhesive resin cement. Forty-five (n=15) extracted human premolar teeth were sectioned at the cemento-enamel junction to obtain root length of fifteen millimeters. Endodontic …
Radiographic Evaluation Of Accuracy Of Surgical Stent For Implant Placement In Knife Edge Posterior Mandibular Ridge In Cases Of Ridge Splitting,
2014
The British University in Egypt
Radiographic Evaluation Of Accuracy Of Surgical Stent For Implant Placement In Knife Edge Posterior Mandibular Ridge In Cases Of Ridge Splitting, Fardos N. Rizk, Engy Abdelhamed
Dentistry
Aim: This study was conducted to evaluate the efficacy of using conventional surgical stents guided by cone beam computed tomography in determining the position and buccolingual inclination of implants placed in posterior mandibular knife edge ridge in cases of ridge splitting with and without bone grafting material. Materials and Methods: The study was conducted on sixteen implants placed bilaterally in posterior knife edge mandibular ridge of four patients, where each patient received four implants in the form of two in each side. Implants on the right side of the ridge were placed following ridge splitting and bone grafting (group A). …
Comparing The Vertical Misfit Of Casts Produced By Two Verification Jigs,
2014
Marquette University
Comparing The Vertical Misfit Of Casts Produced By Two Verification Jigs, Abdulaziz Saeed Alqahtani
Master's Theses (2009 -)
Purpose: To compare the dimensional accuracy between master casts fabricated with verification jigs made of acrylic resin and light cure Triad. Materials and Methods: 10 GC Pattern resin Pattern verifications jigs and 10 Triad gel verification jigs fabricated of a master cast of a mandibular model of 4 internal hex implants. A stone base was fabricated for each verification jig. One screw test was used to evaluate the vertical gap at the terminal abutment using a digital micrometer with an accuracy of 1μm to record the vertical gap for each sample. Results: Triad Gel group has the lowest average distortion …
The Influence Of Vitamin D Metabolism On Gene Expression, Matrix Production And Mineralization During Osteoprecursor Cell-Based Bone Development,
2014
Portland State University
The Influence Of Vitamin D Metabolism On Gene Expression, Matrix Production And Mineralization During Osteoprecursor Cell-Based Bone Development, Shelley S. Mason, Sean S. Kohles, Shelley R. Winn, Randy D. Zelick
Biology Faculty Publications and Presentations
Background: Multipotential precursor cell lines derived from human bone marrow, capable of differentiating into cartilage or bone, may provide a useful tissue development model for studying the regulation and metabolism of putative growth and differentiation factors necessary for tissue regeneration. In mammals, the process of bone development depends on the proliferation and differentiation of osteoblast lineage cells, and the subsequent synthesis and mineralization of bone extracellular matrix (ECM). Vitamin D metabolites play a pivotal role in bone and mineral homeostasis, and are positive factors on bone development. Recently, it was demonstrated that a human-derived engineered osteoblast precursor cell line (OPC1), …
Effect Of Two Different Attachments On The Supporting Structures And Masticatory Capacity Of Implant Retained Mandibular Overdenture,
2014
The British University in Egypt
Effect Of Two Different Attachments On The Supporting Structures And Masticatory Capacity Of Implant Retained Mandibular Overdenture, Fardos N. Rizk
Dentistry
Aim: This study was conducted to compare the effect of ball and socket attachment and GPS attachment in implant retained mandibular overdenture cases regarding changes in: crestal bone height and density surrounding implants, electromyographic activity of temporalis and masseter muscles and occlusal biting force. Materials and Methods: Following two stage surgical protocol twelve completely edentulous patients received two implants placed bilaterally in the canine region (24 implants) to retain mandibular overdenture. Four months following the surgery patients were randomly divided into two equal groups; Group-I received ball and socket attachment while Group-II received GPS attachment upon which mandibular overdentures were …
Comparison Of Occlusal Plane Orientation Obtained Using Five Facebow Systems,
2014
Loma Linda University
Comparison Of Occlusal Plane Orientation Obtained Using Five Facebow Systems, Thomas C. Maveli
Loma Linda University Electronic Theses, Dissertations & Projects
PURPOSE: An in vitro investigation analyzing the sagittal and coronal orientation of the occlusal plane using five different facebow transfer systems. MATERIALS AND METHODS: A phantom head containing a maxillary typodont (the control) was oriented so that Frankfort Horizontal Plane (FHP) corresponds with the horizon. The angle between the occlusal plane of the maxillary arch of the phantom head and the FHP was measured along the sagittal and coronal planes using a digital protractor. Fifteen Facebow records using each of 5 facebow transfer systems (the test groups) were made on the phantom head containing the maxillary typodont. Diagnostic casts of …
Surface Roughness Of Feldspathic Porcelain Polished With Alumina-Zirconia Paste,
2014
Faculty of Dentistry
Surface Roughness Of Feldspathic Porcelain Polished With Alumina-Zirconia Paste, ศุภรักษ์ ยมกกุล
Chulalongkorn University Theses and Dissertations (Chula ETD)
The purpose of this study was to develop a new polishing paste composed of zirconia that was leftover from the zirconia crown/bridge fabrication process that is as effective as diamond paste when used to polish feldspathic porcelain. This study was divided into two parts. First part was to study the surface roughness of feldspathic porcelain after polishing with diamond, alumina, zirconia and alumina-zirconia paste. The result showed that porcelain polished with zirconia paste had the highest mean Ra value, porcelains polished with alumina and alumina-zirconia paste had lower Ra values than zirconia paste while porcelain polished weight diamond paste demonstrated …
