Effect Of Methyl Formate-Methyl Acetate Treatment On Flexural Strength Between Denture Base And Self-Cured Hard Reline Materials,
2018
Faculty of Dentistry
Effect Of Methyl Formate-Methyl Acetate Treatment On Flexural Strength Between Denture Base And Self-Cured Hard Reline Materials, Mongkol Puangpetch
Chulalongkorn University Theses and Dissertations (Chula ETD)
The purpose of this study was to evaluate the effect of methyl formate-methyl acetate (MF-MA) surface treatment on the flexural strength between denture base and hard reline materials. 180 heat-cured acrylic denture base (Meliodent®) specimens were prepared according to ISO 20795-1 (2013) and divided into 18 groups with various autopolymerizing hard reline materials. Group I-III: relined with Unifast Trad®, Group IV-VI: relined with Kooliner® Group VII-IX: relined with Tokuyama® Rebase II Fast (without adhesive, with hardener), Group X-XII: relined with Tokuyama® Rebase II Fast (with adhesive and hardener), Group XIII-XV: relined with Tokuyama® Rebase II Fast (without adhesive and hardener), …
Effect Of Citric Acid On Color Stability And Surface Roughness Of Translucent Monolithic Zirconia With Different Staining Techniques,
2018
Faculty of Dentistry
Effect Of Citric Acid On Color Stability And Surface Roughness Of Translucent Monolithic Zirconia With Different Staining Techniques, Panisa Rinthong
Chulalongkorn University Theses and Dissertations (Chula ETD)
Background and rationale: Translucent monolithic zirconia is developed to solve the problem of esthetic in the conventional generation of zirconia with high opacity. When these materials are used for anterior restoration in the oral cavity, they can contact with foods and beverages that are acidic, which may affect the color stability and surface roughness of the material at different levels. Objective: The objective of this study was to determine the effects of citric acid on color stability and surface roughness of translucent monolithic zirconia with different staining techniques. Materials and Methods: A total of 80 disc specimens of VITA YZ® …
Comparison Of The Efficacy Of Chemical Cleaning Methods In Removing Candida Albicans From Polymethyl Methacrylate,
2018
Faculty of Dentistry
Comparison Of The Efficacy Of Chemical Cleaning Methods In Removing Candida Albicans From Polymethyl Methacrylate, Thanaporn Thanamee
Chulalongkorn University Theses and Dissertations (Chula ETD)
The proper denture hygiene is important to reduce the risk of denture stomatitis. Mechanical cleaning is not sufficient to remove the dental plaque from acrylic denture base, accordingly chemical cleaning is needed. The purpose of this study was to compare the efficacy of chemical cleaning methods in removing Candida albicans from polymethyl methacrylate (PMMA) by comparing the remaining viable cells after cleaning. The total of 120 specimens were prepared. Candida albicans was cultured in broth to log phase. All specimens were randomly placed in 24-well tissue culture plate with 1 ml of Candida albicans cultured for biofilm formation at 37 …
Effect Of Various Curing Conditions In Pressure Cooker On Flexural Strength Of Denture Hard Relining Materials,
2018
Faculty of Dentistry
Effect Of Various Curing Conditions In Pressure Cooker On Flexural Strength Of Denture Hard Relining Materials, Thassanee Suwannachote
Chulalongkorn University Theses and Dissertations (Chula ETD)
This study evaluated the effect of various curing conditions in pressure cooker on flexural strength of hard chairside reline resins (UnifastTM Trad, Tokuyama® Rebase II Fast with and without Hardener®). For each material, 70 specimens were prepared and divided into 7 groups consists of control group and 6 experimental groups: cured in 2 bars air or nitrogen pressure cooker at 55ºC for 10, 15 and 20 min respectively. For Hardener® groups, specimens were soaked in Hardener® for 3 min after curing. The flexural strength was tested using a Universal testing machine. The data were analyzed using Three-way ANOVA, One-way ANOVA …
ผลของกาวติดฟันเทียมต่อประสิทธิภาพการบดเคี้ยวและแรงบดเคี้ยวสูงสุดในผู้ป่วยที่ใส่ฟันเทียมทั้งปาก,
2018
คณะทันตแพทยศาสตร์
ผลของกาวติดฟันเทียมต่อประสิทธิภาพการบดเคี้ยวและแรงบดเคี้ยวสูงสุดในผู้ป่วยที่ใส่ฟันเทียมทั้งปาก, หยาดฝน พลศรี
Chulalongkorn University Theses and Dissertations (Chula ETD)
วัตถุประสงค์เพื่อศึกษาผลของกาวติดฟันเทียมต่อประสิทธิภาพการบดเคี้ยว (masticatory performance) และแรงบดเคี้ยวสูงสุด (maximum occlusal force) ของผู้ป่วยฟันเทียมทั้งปาก ผู้ป่วยสันเหงือกว่างที่ใส่ฟันเทียมทั้งปากบนและล่างจำนวน 65 คน อายุเฉลี่ย 68.9±7.2 ปี เป็นเพศชาย 39 คน เพศหญิง 26 คน มีคุณภาพฟันเทียมอยู่ในระดับที่ยอมรับได้ (กลุ่ม A) และยอมรับไม่ได้ (กลุ่ม UA) จำนวน 44 และ 21 คน ตามลำดับ มีลักษณะของเนื้อเยื่อรองรับฟันเทียมตามระบบของ American College of Prosthodontists กลุ่ม I, II, III และ IV จำนวน 19 30 11 และ 5 คนตามลำดับ ผู้ป่วยเข้ารับการทดสอบประสิทธิภาพการบดเคี้ยวด้วยการเคี้ยวถั่วลิสงจำนวน 20 รอบวงเคี้ยว ถั่วลิสงที่ผ่านการเคี้ยวแล้วจะถูกร่อนผ่านเครื่องสั่น ด้วยตะแกรงทดสอบมาตรฐานจำนวน 12 ชั้น เพื่อวิเคราะห์หาขนาดอนุภาคกลางของถั่วลิสง (median particle size) และเข้ารับการทดสอบแรงบดเคี้ยวสูงสุดด้วยการกัดแผ่นฟิล์มที่อ่อนไหวต่อความดัน (pressure sensitive film) โดยวางแผ่นฟิล์มระหว่างด้านบดเคี้ยวของฟันเทียมบนและล่างในตำแหน่งสบสนิทที่สุด (maximum intercuspal position) วิเคราะห์และแปรผลด้วยโปรแกรมสถิติสำเร็จรูป เพื่อเปรียบเทียบประสิทธิภาพการบดเคี้ยวและแรงบดเคี้ยวสูงสุดระหว่างก่อน (T1) และหลังการใช้กาวติดฟันเทียมอย่างต่อเนื่องเป็นระยะเวลา 1 เดือน (T2) สถิติที่ใช้ในการทดสอบคือ paired t-test ที่ระดับความเชื่อมั่นร้อยละ 95 ผลการศึกษาพบว่าเมื่อเปรียบเทียบก่อนและหลังการใช้กาวติดฟันเทียม ประสิทธิภาพการบดเคี้ยวเพิ่มขึ้นอย่างมีนัยสำคัญในกลุ่ม A (P = 0.035) แต่ไม่มีความแตกต่างอย่างมีนัยสำคัญทางสถิตในกลุ่ม UA (P = 0.313) แรงบดเคี้ยวสูงสุดลดลงอย่างมีนัยสำคัญในกลุ่ม A (P = 0.020) แต่ไม่มีความแตกต่างอย่างมีนัยสำคัญทางสถิติในกลุ่ม UA (P …
Effect Of Image Sharpening On Radiographic Image Quality,
2017
Loma Linda University
Effect Of Image Sharpening On Radiographic Image Quality, Jefferson Lee Clark
Loma Linda University Electronic Theses, Dissertations & Projects
There is evidence that capture and processing of the digital radiographic images may contain artifacts that could reduce the diagnostic value of dental radiographs. This phenomenon has been reported through various case reports. However, its effect on radiographic image quality has not been studied. The purpose of this study is to evaluate the effect of image processing on the quality of dental digital radiographs using the most common type of filter; sharpening. Four imaging modalities (2 CMOS, 1 PSP, 1 conventional film) were used to radiograph a DDQA imaging phantom (Digital Dental Quality Assurance phantom) and to create a flat …
Analysis Of Flexural Strength And Monotonic Load To Failure Following Simulated Chairside Adjustments And Repair In A Lithium Disilicate Glass-Ceramic,
2017
Marquette University
Analysis Of Flexural Strength And Monotonic Load To Failure Following Simulated Chairside Adjustments And Repair In A Lithium Disilicate Glass-Ceramic, Ali Ramadhan
Master's Theses (2009 -)
Introduction: There are no studies regarding e.max Press that evaluate post-adjustment healing protocols and their effect on the load to failure in a clinically relevant test. It is essential to find the ultimate treatment protocol which will help clinicians preserve the physical properties of the ceramic restoration after adjustment. Material and Methods: The total number of samples used in this study was 440 IPS e.max press discs. The discs were 15 mm in diameter and 1 mm of thickness. The material was tested for flexural strength and monotonic load to failure. The test was done in two parts and with …
Comparison Of Anterior Denture Teeth Arrangements Made With The Tooth Mold Template And Definitive Computer-Aided Design & Computer-Aided Manufacturing Complete Removable Dental Prostheses,
2017
Marquette University
Comparison Of Anterior Denture Teeth Arrangements Made With The Tooth Mold Template And Definitive Computer-Aided Design & Computer-Aided Manufacturing Complete Removable Dental Prostheses, Jose Antonio Sierra
Master's Theses (2009 -)
Introduction: There is a dearth of information in the refereed literature regarding esthetics of CAD/CAM complete removable dental prostheses (CRDPs). The purpose of this study was to investigate and compare the anterior denture teeth arrangement made with the medium-size anterior tooth mold template to CAD/CAM complete removable dental prostheses fabricated with bonded denture teeth and milled teeth. Material and methods: Poly-vinyl siloxane impression were made of an edentulous maxillary model and selected for use as the patient template. The edentulous model was mounted on a semi-adjustable articulator. Definitive impressions and jaw relation records were made according to the manufacturer’s protocol. …
Effect Of One Piece Versus Two Piece Mini Implants On Bone Height Of Implant Retained Mandibular Overdenture,
2017
The British University in Egypt
Effect Of One Piece Versus Two Piece Mini Implants On Bone Height Of Implant Retained Mandibular Overdenture, Fardos N. Rizk, Jehan Fikry Prof., Amr Badr, Ahmed Damarisy Dr.
Dentistry
Introduction: Severely atrophied mandibles are a common problem within elderly completely edentulous patients. Given their small diameters, long height and self-tapping characteristics, miniimplant retained over-dentures are a valuable treatment option in such patients. Mini-implants are usually once-piece implants, however recently two-piece mini-implants were introduced with aim of addressing the angulation problems. The success of the latter has not been thoroughly studied. Crestal bone height measurements are normally used to evaluate implant success. Therefore this study was conducted to evaluate the effect of one piece versus two piece ERA mini implants on crestal bone height of implant retained mandibular over-denture. Materials …
Mucosa-Supported Stereolithographic Surgical Guide Versus Conventional Surgical Stent In Implant Supported Overdenture,
2017
The British University in Egypt
Mucosa-Supported Stereolithographic Surgical Guide Versus Conventional Surgical Stent In Implant Supported Overdenture, Fardos N. Rizk, Marwa Sabet Prof., Shaimaa Azoz, Eman Gamal
Dentistry
Purpose: The aim of the study was to compare between the accuracy of mucosa-supported stereolithographic surgical guide versus conventional surgical stent in implant supported overdenture. Materials and methods: Twelve patients with completely edentulous patients were selected for this study and divided into three groups. Group (A): 8 implants were placed in the mandible using conventional surgical stents during implant insertion. Group (B): 8 implants were placed in the mandible using partially limiting mucosa-supported stereolithographic (SLA) surgical guide during implant insertion. Group (C): 8 implants were placed in the mandible using completely limiting mucosa-supported stereolithographic (SLA) surgical guide during implant insertion. …
Subjective And Objective Outcomes On Denture Adhesive Usage Among Complete Denture Wearers,
2017
Faculty of Dentistry
Subjective And Objective Outcomes On Denture Adhesive Usage Among Complete Denture Wearers, Budsara Thongyoi
Chulalongkorn University Theses and Dissertations (Chula ETD)
The propose of this clinical study was to evaluate the subjective and objective assessment factors affecting decision of complete denture wearers to use or not use denture adhesive. Sixty-six fully edentulous using upper and lower conventional complete dentures (aged 53 to 83 years) were recruited in this study. (1) Condition of denture-supporting tissue (ACP classification), (2) denture quality (CU-modified kapur criteria), (3) patients' satisfaction in prostheses and (4) oral impact on daily performances (OIDP) were evaluated as baseline (T0). All participants were assigned to use denture adhesive (Polident®, Ireland) for 1 month period and made decision by themselves to continue …
The Synthesis, Modification And Application Of Silica Nanoparticles In Polymethyl Methacrylate Denture Base,
2017
Faculty of Dentistry
The Synthesis, Modification And Application Of Silica Nanoparticles In Polymethyl Methacrylate Denture Base, Pornpot Jiangkongkho
Chulalongkorn University Theses and Dissertations (Chula ETD)
This study aimed to investigate amount of γ-methacryloxypropyltrimethoxysilane (MPS) silanized on experimental nanosilica particles (NPs), amount of NPs and amount of MPS silanized NP on flexural strength (FS), flexural modulus (FM), and fracture toughness (FT) of NP reinforced polymethymethacrylate (PMMA). The chemisorbed amount of MPS was determined using elemental analysis. Six groups (n=8) were prepared with chemisorbed amount and mixed with PMMA-monomer to make 0.25, 0.5, 1, 5, 10 and 15% (w/w) of NP reinforced PMMA. PMMA without NP served as control. Seven groups (n=8) were prepared with 1% of NPs silanized with 0, 0.061, 0.123, 0.246, 0.493, 0.987, and …
Effect Of 3-Methacryloxypropyltrimethoxysilane Modified Zinc Oxide Nanoparticles Incorporated In Polymethylmethacrylate Material On Antifungal, Optical And Mechanical Properties,
2017
Faculty of Dentistry
Effect Of 3-Methacryloxypropyltrimethoxysilane Modified Zinc Oxide Nanoparticles Incorporated In Polymethylmethacrylate Material On Antifungal, Optical And Mechanical Properties, Krid Kamonkhantikul
Chulalongkorn University Theses and Dissertations (Chula ETD)
This study aimed to evaluate 1) the characteristics of different amount of 3-methacryloxypropyltrimethoxysilane (MPS) deposited on zinc oxide nanoparticles (ZnOnps) by Fourier transform infrared spectroscopy (FTIR) and thermogravimetric analysis (TGA) before and after tetrahydrofuran washing, 2) the effect of different MPS amount deposited on ZnOnps incorporated in PMMA material on mechanical properties, and 3) the effect of different ZnOnps amounts with or without MPS incorporated in PMMA material on antifungal, optical and mechanical properties. The FTIR and TGA results showed the success of silanization. The monolayered silane molecules were parallelly oriented on the ZnOnps surface. The different MPS amounts (0-14.4 …
The Quality Of Complete Denture, Patient's Satisfaction, Oral Health-Related Quality Of Life, And Their Association,
2017
Faculty of Dentistry
The Quality Of Complete Denture, Patient's Satisfaction, Oral Health-Related Quality Of Life, And Their Association, Nareudee Limpuangthip
Chulalongkorn University Theses and Dissertations (Chula ETD)
The objective of this study was to determine the association of complete denture quality, patient's satisfaction, and Oral Health-related Quality of Life (OHRQoL). A total of 126 complete denture wearers was interviewed for the primary outcome, OHRQoL, using Oral Impacts on Daily Performances (OIDP) index. Secondary outcomes were patient's satisfaction and masticatory performance. Denture retention and stability were scored following the conventional and Chulalongkorn University (CU)-modified Kapur criteria. Esthetic-assessment criteria was evaluated from patient's photographs. It was found that limited eating/chewing was the most common problem, and an ill-fitting denture was a primary cause of any reported problems. Unacceptable denture …
The Inflammatory Response Of Epithelial Cell To Corrosion Products From Recast Palladium -Silver Alloy,
2017
Faculty of Dentistry
The Inflammatory Response Of Epithelial Cell To Corrosion Products From Recast Palladium -Silver Alloy, Verapol Singkarlsiri
Chulalongkorn University Theses and Dissertations (Chula ETD)
In dentistry, there is an increase in alternative metals such as palladium or silver to add into noble metal alloys in order to improve properties and reduce cost. Apart from using other metals to replace gold or platinum, reuse is another way to save the cost. There are many studies on the recast dental alloys on mechanical properties and how many percentages of new alloys needed to add in the recasting process. It has been well accepted that amount of new and used alloys would affect the mechanical and physical properties. The biocompatibility of the alloys, however, has not been …
อิทธิพลของการผนึกเนื้อฟันทันทีด้วยสารยึดติดเซลฟ์เอทช์ที่มีผลต่อการบ่มตัวของวัสดุพิมพ์ฟัน,
2017
คณะทันตแพทยศาสตร์
อิทธิพลของการผนึกเนื้อฟันทันทีด้วยสารยึดติดเซลฟ์เอทช์ที่มีผลต่อการบ่มตัวของวัสดุพิมพ์ฟัน, เอกลักษณ์ หวังหงส์หิรัญ
Chulalongkorn University Theses and Dissertations (Chula ETD)
วัตถุประสงค์ เพื่อศึกษาผลของสารยึดติดที่ใช้ผนึกเนื้อฟันต่อการก่อตัวของวัสดุพิมพ์ฟัน วัสดุและวิธีการ ฟันกรามใหญ่ของมนุษย์ที่ปราศจากรอยผุ จำนวน ๒๒๕ ซี่ ฝังในท่อพลาสติกด้วยอะคริลิก โดยให้ตัวฟันโผล่ขึ้นมา ตัดด้านบดเคี้ยวออกในแนวตั้งฉากกับแกนฟันด้วยเครื่องตัดความเร็วต่ำจนเนื้อฟันเผยออก แบ่งฟันเป็น ๔ กลุ่ม กลุ่มละ ๕๕ ซี่ ตามชนิดของสารยึดติดที่ใช้ผนึกเนื้อฟัน ได้แก่ กลุ่มที่ ๑.ฟันที่เคลือบด้วยด้วยสารยึดติดเซลฟ์เอทช์ซีโนไฟฟ์พลัสและซิงเกิลบอนด์ยูนิเวอร์ซอลในสภาวะออกซิเจน กลุ่มที่ ๒.เนื้อฟันที่เคลือบสารยึดติดเซลฟ์เอทช์ทั้งสองชนิดอยู่ในสภาวะก๊าซไนโตรเจน กลุ่มที่ ๓.เนื้อฟันที่ไม่มีการเคลือบด้วยสารใด ๆ และกลุ่มที่ ๔.ฟันที่เคลือบด้วยสารยึดติดทั้งสองชนิดแล้วถูกเช็ดด้วยแอลกอฮอล์ โดยหลังทาด้วยสารยึดติดจะทำการบ่มด้วยแสง ที่ตามองเห็นจากเครื่องฉายแสง จากนั้นปิดทับด้วยวัสดุพิมพ์พอลิไวนิลไซลอกเซนกลุ่มละ ๑๐ ซี่ เมื่อปล่อยให้วัสดุพิมพ์ก่อตัว ๖ นาที นำวัสดุพิมพ์ออกเพื่อตรวจสอบการก่อตัวที่ผิวหน้าด้วยตาเปล่าและด้วยกล้องจุลทรรศน์ชนิดสเตอริโอ จากนั้นทดสอบด้วยวัสดุพิมพ์พอลิอีเทอร์โดยวิธีเดียวกัน นำส่วนชิ้นทดสอบที่เหลืออีกกลุ่มละ ๑๐ ชิ้น วัดค่าความเป็นกรดด่าง และอีกกลุ่มละ ๕ ชิ้น ไปวิเคราะห์หาธาตุที่ผิวหน้าด้วยกล้องอิเล็กตรอนส่องกราดฟังก์ชั่นอีดีเอ็มเอ็กซ์ ผลการศึกษา เนื้อฟันที่เคลือบสารยึดติดเซลฟ์เอทช์ทั้งสองชนิดมีค่าความเป็นกรดด่างใกล้เคียงกัน และร้อยละร้อยของวัสดุพิมพ์ด้านที่สัมผัสกับผิวหน้าของชิ้นทดสอบกลุ่มที่ ๑ และกลุ่มที่ ๒ ที่เคลือบด้วยสารยึดติดเซลฟ์เอทช์ซีโนไฟฟ์พลัสถูกยับยั้งการก่อตัว ขณะที่ผิวหน้าของวัสดุพิมพ์ด้านที่สัมผัสกับผิวหน้าชิ้นทดสอบกลุ่มที่ ๓ และกลุ่มที่ ๔ มีการก่อตัวสมบูรณ์ เมื่อดูด้วยตาเปล่าและด้วยกล้องจุลทรรศน์ชนิดสเตอริโอ ส่วนของการหาธาตุบนผิวฟันของทั้งสามกลุ่ม พบว่าผิวเนื้อฟันที่เคลือบด้วยสารยึดติดเซลฟ์เอทช์ซีโนไฟฟ์พลัสมีองค์ประกอบของธาตุซัลเฟอร์ขณะที่ผิวเนื้อฟันที่เคลือบด้วยสารยึดติดเซลฟ์เอทช์ซิงเกิลบอนด์ยูนิเวอร์ซอล และเนื้อฟันที่ไม่มีการเคลือบด้วยสารใด ๆ ไม่พบธาตุดังกล่าว สรุป สารยึดติดเซลฟ์เอทช์ซีโนไฟฟ์พลัสที่ผนึกผิวเนื้อฟันมีผลต่อการบ่มตัวของวัสดุพิมพ์พอลิไวนิลไซลอกเซน
คำสำคัญ: การผนึกเนื้อฟัน สารยึดติด พอลิไวนิลไซลอกเซน
การยึดอยู่ของสะพานฟันรูปแบบใหม่ที่กรอฟันน้อย ภายหลังได้รับแรงกระทำแบบเป็นวัฏจักร,
2017
คณะทันตแพทยศาสตร์
การยึดอยู่ของสะพานฟันรูปแบบใหม่ที่กรอฟันน้อย ภายหลังได้รับแรงกระทำแบบเป็นวัฏจักร, รุจิรา ภัทรทิวานนท์
Chulalongkorn University Theses and Dissertations (Chula ETD)
การศึกษานี้มีวัตถุประสงค์เพื่อออกแบบสะพานฟันที่ยึดด้วยวัสดุเรซินชนิดกรอฟันน้อยในฟันหลังรูปแบบใหม่ โดยเปรียบเทียบการยึดอยู่ระหว่าง 3 รูปแบบที่แตกต่างกันภายหลังได้รับแรงกระทำแบบเป็นวัฏจักร โดยใช้ฟันมนุษย์ที่ได้รับการถอนจำนวน 60 ซี่ เป็นฟันกรามน้อย 30 ซี่ และฟันกรามแท้ 30 ซี่ นำฟันกรามน้อยและฟันกรามแท้อย่างละซี่ยึดเข้ากับอะคริลิกเรซินชนิดบ่มตัวด้วยตัวเองที่ระยะห่าง 11 มิลลิเมตรเพื่อจำลองการสูญเสียฟันกรามแท้ซี่ที่หนึ่ง แบ่งบล็อกฟันออกเป็น 3 กลุ่มๆ ละ 10 บล็อก ตามรูปแบบการออกแบบชิ้นงาน โดยกลุ่มที่ 1 ชิ้นงานเป็นส่วนพักนอกตัวฟันด้านบดเคี้ยวที่มีลักษณะเช่นเดียวกับออนเลย์ กลุ่มที่ 2 ชิ้นงานเป็นส่วนพักในตัวฟันด้านประชิดร่วมกับข้อต่อขยับได้ และกลุ่มที่ 3 ชิ้นงานเป็นส่วนพักในตัวฟันด้านประชิดร่วมกับข้อต่อขยับไม่ได้ ชิ้นงานทำด้วยโลหะผสมไร้สกุล ปรับสภาพพื้นผิวด้านในด้วยอะลูมินาขนาด 50 ไมโครเมตร และยึดด้วยเรซินซีเมนต์ชนิดซุปเปอร์บอนด์ซีแอนด์บี ทดสอบชิ้นตัวอย่างด้วยแรงกดในแนวตรงลงบนฟันหลักทั้ง 2 ซี่และฟันแขวน ด้วยแรงขนาด 50 – 800 นิวตัน ที่ความถี่ 4 รอบต่อวินาที จำนวน 2,500,000 รอบ ภายหลังทดสอบด้วยแรงกด ถ้าชิ้นงานไม่เกิดความล้มเหลวจะนำไปทดสอบด้วยแรงดึงขึ้นในแนวตรงจนกระทั่งเกิดความล้มเหลวของชิ้นงาน และประเมินความล้มเหลวที่เกิดขึ้นว่าเกิดที่ระดับใด ผลการทดสอบพบว่าชิ้นตัวอย่างของทุกกลุ่มอยู่รอดภายหลังทดสอบด้วยแรงกดแบบเป็นวัฏจักร เมื่อทดสอบด้วยแรงดึงพบว่าค่าเฉลี่ยแรงยึดของชิ้นงานทั้ง 3 กลุ่มมีความแตกต่างกันอย่างมีนัยสำคัญทางสถิติ (p<0.05) โดยกลุ่มที่ 3 มีค่าแรงยึดสูงที่สุดโดยเฉลี่ย 529.9 ± 86.2 นิวตัน รองลงมาคือกลุ่มที่ 1 ที่มีค่า 396.7 ± 73.2 นิวตัน และกลุ่มที่ 2 มีค่าต่ำที่สุดโดยเฉลี่ย 228.3 ± 52.5 นิวตัน โดยรูปแบบความล้มเหลวของชิ้นงานจะเกิดการหลุดบริเวณรอยต่อระหว่างชิ้นงานและเรซินซีเมนต์และ/หรือภายในเรซินซีเมนต์เป็นส่วนใหญ่ ผลการศึกษานี้แสดงให้เห็นว่าสะพานฟันหลังชนิดกรอฟันน้อยที่ชิ้นงานมีส่วนพักในตัวฟันด้านประชิดร่วมกับการใช้ข้อต่อขยับไม่ได้อาจส่งผลให้มีอายุการใช้งานที่ยาวนานกว่าชิ้นงานที่มีลักษณะเป็นส่วนพักนอกตัวฟันด้านบดเคี้ยวที่ใช้อยู่ในปัจจุบัน
Study Retention And Physical Properties Of Conventional And Microwave-Cured Acrylic Resin Complete Denture: An In-Vivo And In-Vitro Investigation,
2016
The British University in Egypt
Study Retention And Physical Properties Of Conventional And Microwave-Cured Acrylic Resin Complete Denture: An In-Vivo And In-Vitro Investigation, Fardos N. Rizk, Amany Elhadary
Dentistry
Aim: This study was two folded: an in-vivo study to compare the retentive properties of Lucitone conventional cured denture base resin and Nature-Cryl MC microwave cured denture base resin and an in-vitro study to compare the internal adaptation, fracture resistance, roughness, hardness and colour stability of these two materials and correlate the laboratory results with each other and with the clinical results. Materials and Methods: Twenty completely edentulous male patients received twenty complete dentures constructed from Lucitone conventional cured denture base resin. The retentive properties of the upper complete dentures were measured using force measurement gauge at one week, one …
Managing Peri-Implantitis,
2016
University of New England
Managing Peri-Implantitis, Namita Khandelwal
Dental Medicine Faculty Publications
This guide, used by MetLife for its dental continuing education program, focuses on the inflammatory pathology around dental implants. It outlines the risk factors and diagnostic criteria for peri-implantitis, an inflammatory process resulting in progressive loss of bone around the implant. The guide also provides treatment approaches for peri-implantitis, including surgical and non-surgical options.
Effect Of Two Different Maxillary Treatment Options On Supporting Structures Of Mini Implant Retained Mandibular Overdenture,
2016
The British University in Egypt
Effect Of Two Different Maxillary Treatment Options On Supporting Structures Of Mini Implant Retained Mandibular Overdenture, Fardos N. Rizk
Dentistry
Objectives: This study was conducted to evaluate whether maxillary conventional complete denture or narrow diameter implant retained maxillary overdenture is more compatible on opposing crestal bone height surrounding mini implants retaining mandibular overdenture. Materials and Methods: Fourteen male completely edentulous patients received mandibular overdentures retained by four one piece mini implants with ERA attachments placed anterior to the mental foramen. Patients were randomly divided into two groups: Group I received opposing maxillary conventional complete denture and Group II received opposing maxillary overdenture retained by four one piece narrow diameter implants with ball attachments placed in the anterior maxilla. Once patients …