Us Army Ordnance Technical Intelligence Agency, Robert Bolin , Depositor Sep 1957

Us Army Ordnance Technical Intelligence Agency, Robert Bolin , Depositor

United States Department of Defense Military Intelligence

Historical Data Cards were used to record the organizational history of units within the Army. This card was provided to Robert Bolin by the US Army Institute of Heraldry in 1985.

The Ordnance Technical Intelligence Agency (OTIA) was special-purpose military unit assigned to the Chief of Ordnance. The Chief of Ordnance was the general in charge of the Ordnance Corps. The OTIA was organized to perform and coordinate intelligence functions of the US Army Ordnance Corps.

The OTIA was discontinued in 1962 when most of the Army Technical Services were reorganized out of existence. The functions, personnel, records, and equipment …


A Method Of Developing Engineering Soil Maps For Kentucky, Robert C. Deen Aug 1957

A Method Of Developing Engineering Soil Maps For Kentucky, Robert C. Deen

Kentucky Transportation Center Research Report

No abstract provided.


Ten Rural Highway Base Stabilization Projects, James H. Havens, William B. Drake Aug 1957

Ten Rural Highway Base Stabilization Projects, James H. Havens, William B. Drake

Kentucky Transportation Center Research Report

During the last week o£ September, 1956, the Division of Rural Highways requested assistance from the Research Division in conducting a series of ten experimental base stabilization projects which were to be geared more-or-less to a practical rural roads development program in which existing soils and local granular materials might be most advantageously treated and stabilized to provide fairly low cost base courses and surfaces, adequate for light rural traffic. The idea of actually constructing a base and bituminous surface for this type of road would represent a refinement over the traditional traffic-bound base type of construction which usually serves …


An Investigation Of High-Strength, Deformed Steel Bars For Concrete Reinforcement, Sidney A. Guralnick, George Winter Jul 1957

An Investigation Of High-Strength, Deformed Steel Bars For Concrete Reinforcement, Sidney A. Guralnick, George Winter

CCFSS Library (1939 - present)

INTRODUCTION High strength steel as reinforcement for concrete has received some serious attention by researchers and by the construction industries as long ago as the early 1900' s. Recent developments abroad, notably in Sweden, Germany and Austria, have caused renewed interest in the use of this material in concrete structures. The term "high-strength" is somewhat ambiguous since it usually has been employed to describe the type of steel used in cables and strands for prestressed concrete or suspension bridge structures. Such steels commonly have proof stresses of the order of 200,000 psi. However, in the case of ordinary reinforced concrete …


Comparative Laboratory Evaluation Of A Modified Class I Base Mixture, James H. Havens, William B. Drake Jul 1957

Comparative Laboratory Evaluation Of A Modified Class I Base Mixture, James H. Havens, William B. Drake

Kentucky Transportation Center Research Report

No abstract provided.


Test 625: Someca Som 45 Diesel, Nebraska Tractor Test Lab Jun 1957

Test 625: Someca Som 45 Diesel, Nebraska Tractor Test Lab

Nebraska Tractor Tests

EXPLANATION OF TEST REPORT: SOMECA 45 DIESEL TEST A: The manufacturer's representative operates the tractor for a minimum of 12 hours using light to heavy drawbar loads in each gear. This serves as a period for limber up, general observation and adjustments. Adjustments that are permissible include valve tappet clearance, breaker ,point gap, spark plug gaps, clutch and others of a similar nature. No new parts or accessories can be installed without having mention made of it in the report. No data' are recorded during this preliminary run except the time that the engine is operated. BELT HORSEPOWER TESTS TEST …


Test 624: Minneapolis-Moline 335 Gasoline, Nebraska Tractor Test Lab Jun 1957

Test 624: Minneapolis-Moline 335 Gasoline, Nebraska Tractor Test Lab

Nebraska Tractor Tests

EXPLANATION OF TEST REPORT: MINNEAPOLIS-MOLINE 335 GASOLINE TEST A: The manufacturer's representative operates the tractor for a minimum of 12 hours using light to heavy drawbar loads in each gear. This serves as a period for limber up, general observation and adjustments. Adjustments that are permissible include valve tappet clearance, breaker ,point gap, spark plug gaps, clutch and others of a similar nature. No new parts or accessories can be installed without having mention made of it in the report. No data' are recorded during this preliminary run except the time that the engine is operated. BELT HORSEPOWER TESTS TEST …


Test 623: Allis-Chalmers D-14 Gasoline, Nebraska Tractor Test Lab Jun 1957

Test 623: Allis-Chalmers D-14 Gasoline, Nebraska Tractor Test Lab

Nebraska Tractor Tests

EXPLANATION OF TEST REPORT: ALLIS-CHALMERS D-14 GAS TEST A: The manufacturer's representative operates the tractor for a minimum of 12 hours using light to heavy drawbar loads in each gear. This serves as a period for limber up, general observation and adjustments. Adjustments that are permissible include valve tappet clearance, breaker ,point gap, spark plug gaps, clutch and others of a similar nature. No new parts or accessories can be installed without having mention made of it in the report. No data' are recorded during this preliminary run except the time that the engine is operated. BELT HORSEPOWER TESTS TEST …


Test 620: Mccormick Farmall 450 Lpg, Nebraska Tractor Test Lab May 1957

Test 620: Mccormick Farmall 450 Lpg, Nebraska Tractor Test Lab

Nebraska Tractor Tests

EXPLANATION OF TEST REPORT: McCORMICK FARMALL 450 LPG TEST A: The manufacturer's representative operates the tractor for a minimum of 12 hours using light to heavy drawbar loads in each gear. This serves as a period for limber up, general observation and adjustments. Adjustments that are permissible include valve tappet clearance, breaker ,point gap, spark plug gaps, clutch and others of a similar nature. No new parts or accessories can be installed without having mention made of it in the report. No data' are recorded during this preliminary run except the time that the engine is operated. BELT HORSEPOWER TESTS …


Test 622: Mccormick Farmall 350 Lpg, Nebraska Tractor Test Lab May 1957

Test 622: Mccormick Farmall 350 Lpg, Nebraska Tractor Test Lab

Nebraska Tractor Tests

EXPLANATION OF TEST REPORT: McCORMICK FARMALL 350 LPG TEST A: The manufacturer's representative operates the tractor for a minimum of 12 hours using light to heavy drawbar loads in each gear. This serves as a period for limber up, general observation and adjustments. Adjustments that are permissible include valve tappet clearance, breaker ,point gap, spark plug gaps, clutch and others of a similar nature. No new parts or accessories can be installed without having mention made of it in the report. No data' are recorded during this preliminary run except the time that the engine is operated. BELT HORSEPOWER TESTS …


Test 619: International 350 Utility Lpg, Nebraska Tractor Test Lab May 1957

Test 619: International 350 Utility Lpg, Nebraska Tractor Test Lab

Nebraska Tractor Tests

EXPLANATION OF TEST REPORT TEST A: The manufacturer's representative operates the tractor for a minimum of 12 hours using light to heavy drawbar loads in each gear. This serves as a period for limber up, general observation and adjustments. Adjustments that are permissible include valve tappet clearance, breaker ,point gap, spark plug gaps, clutch and others of a similar nature. No new parts or accessories can be installed without having mention made of it in the report. No data' are recorded during this preliminary run except the time that the engine is operated. BELT HORSEPOWER TESTS TEST B: The throttle …


Test 621: International 650 Lpg, Nebraska Tractor Test Lab May 1957

Test 621: International 650 Lpg, Nebraska Tractor Test Lab

Nebraska Tractor Tests

EXPLANATION OF TEST REPORT: INTERNATIONAL HARVESTER 650 LPG TEST A: The manufacturer's representative operates the tractor for a minimum of 12 hours using light to heavy drawbar loads in each gear. This serves as a period for limber up, general observation and adjustments. Adjustments that are permissible include valve tappet clearance, breaker ,point gap, spark plug gaps, clutch and others of a similar nature. No new parts or accessories can be installed without having mention made of it in the report. No data' are recorded during this preliminary run except the time that the engine is operated. BELT HORSEPOWER TESTS …


Test 618: International 650 Gasoline, Nebraska Tractor Test Lab May 1957

Test 618: International 650 Gasoline, Nebraska Tractor Test Lab

Nebraska Tractor Tests

EXPLANATION OF TEST REPORT TEST A: The manufacturer's representative operates the tractor for a minimum of 12 hours using light to heavy drawbar loads in each gear. This serves as a period for limber up, general observation and adjustments. Adjustments that are permissible include valve tappet clearance, breaker ,point gap, spark plug gaps, clutch and others of a similar nature. No new parts or accessories can be installed without having mention made of it in the report. No data' are recorded during this preliminary run except the time that the engine is operated. BELT HORSEPOWER TESTS TEST B: The throttle …


Test 616: Mccormick Farmall 230 Gasoline, Nebraska Tractor Test Lab May 1957

Test 616: Mccormick Farmall 230 Gasoline, Nebraska Tractor Test Lab

Nebraska Tractor Tests

EXPLANATION OF TEST REPORT TEST A: The manufacturer's representative operates the tractor for a minimum of 12 hours using light to heavy drawbar loads in each gear. This serves as a period for limber up, general observation and adjustments. Adjustments that are permissible include valve tappet clearance, breaker ,point gap, spark plug gaps, clutch and others of a similar nature. No new parts or accessories can be installed without having mention made of it in the report. No data' are recorded during this preliminary run except the time that the engine is operated. BELT HORSEPOWER TESTS TEST B: The throttle …


Test 617: Mccormick Farmall 130 Gasoline, Nebraska Tractor Test Lab May 1957

Test 617: Mccormick Farmall 130 Gasoline, Nebraska Tractor Test Lab

Nebraska Tractor Tests

EXPLANATION OF TEST REPORT: McCORMICK FARMALL 130 GASOLINE TEST A: The manufacturer's representative operates the tractor for a minimum of 12 hours using light to heavy drawbar loads in each gear. This serves as a period for limber up, general observation and adjustments. Adjustments that are permissible include valve tappet clearance, breaker ,point gap, spark plug gaps, clutch and others of a similar nature. No new parts or accessories can be installed without having mention made of it in the report. No data' are recorded during this preliminary run except the time that the engine is operated. BELT HORSEPOWER TESTS …


Test 615: International 350 Utility Gasoline, Nebraska Tractor Test Lab May 1957

Test 615: International 350 Utility Gasoline, Nebraska Tractor Test Lab

Nebraska Tractor Tests

EXPLANATION OF TEST REPORT TEST A: The manufacturer's representative operates the tractor for a minimum of 12 hours using light to heavy drawbar loads in each gear. This serves as a period for limber up, general observation and adjustments. Adjustments that are permissible include valve tappet clearance, breaker ,point gap, spark plug gaps, clutch and others of a similar nature. No new parts or accessories can be installed without having mention made of it in the report. No data' are recorded during this preliminary run except the time that the engine is operated. BELT HORSEPOWER TESTS TEST B: The throttle …


Test 614: Case 301 Diesel, Nebraska Tractor Test Lab Apr 1957

Test 614: Case 301 Diesel, Nebraska Tractor Test Lab

Nebraska Tractor Tests

EXPLANATION OF TEST REPORT TEST A: The manufacturer's representative operates the tractor for a minimum of 12 hours using light to heavy drawbar loads in each gear. This serves as a period for limber up, general observation and adjustments. Adjustments that are permissible include valve tappet clearance, breaker ,point gap, spark plug gaps, clutch and others of a similar nature. No new parts or accessories can be installed without having mention made of it in the report. No data' are recorded during this preliminary run except the time that the engine is operated. BELT HORSEPOWER TESTS TEST B: The throttle …


Test 613: Case 311 Gasoline, Nebraska Tractor Test Lab Apr 1957

Test 613: Case 311 Gasoline, Nebraska Tractor Test Lab

Nebraska Tractor Tests

EXPLANATION OF TEST REPORT: CASE 311 GASOLINE TEST A: The manufacturer's representative operates the tractor for a minimum of 12 hours using light to heavy drawbar loads in each gear. This serves as a period for limber up, general observation and adjustments. Adjustments that are permissible include valve tappet clearance, breaker ,point gap, spark plug gaps, clutch and others of a similar nature. No new parts or accessories can be installed without having mention made of it in the report. No data' are recorded during this preliminary run except the time that the engine is operated. BELT HORSEPOWER TESTS TEST …


Test 610: International 350 Utility, Nebraska Tractor Test Lab Apr 1957

Test 610: International 350 Utility, Nebraska Tractor Test Lab

Nebraska Tractor Tests

EXPLANATION OF TEST REPORT TEST A: The manufacturer's representative operates the tractor for a minimum of 12 hours using light to heavy drawbar loads in each gear. This serves as a period for limber up, general observation and adjustments. Adjustments that are permissible include valve tappet clearance, breaker ,point gap, spark plug gaps, clutch and others of a similar nature. No new parts or accessories can be installed without having mention made of it in the report. No data' are recorded during this preliminary run except the time that the engine is operated. BELT HORSEPOWER TESTS TEST B: The throttle …


Test 612: Mccormick Farmall 450 Gasoline, Nebraska Tractor Test Lab Apr 1957

Test 612: Mccormick Farmall 450 Gasoline, Nebraska Tractor Test Lab

Nebraska Tractor Tests

EXPLANATION OF TEST REPORT TEST A: The manufacturer's representative operates the tractor for a minimum of 12 hours using light to heavy drawbar loads in each gear. This serves as a period for limber up, general observation and adjustments. Adjustments that are permissible include valve tappet clearance, breaker ,point gap, spark plug gaps, clutch and others of a similar nature. No new parts or accessories can be installed without having mention made of it in the report. No data' are recorded during this preliminary run except the time that the engine is operated. BELT HORSEPOWER TESTS TEST B: The throttle …


Test 611: Mccormick Farmall 350 Gasoline, Nebraska Tractor Test Lab Apr 1957

Test 611: Mccormick Farmall 350 Gasoline, Nebraska Tractor Test Lab

Nebraska Tractor Tests

EXPLANATION OF TEST REPORT TEST A: The manufacturer's representative operates the tractor for a minimum of 12 hours using light to heavy drawbar loads in each gear. This serves as a period for limber up, general observation and adjustments. Adjustments that are permissible include valve tappet clearance, breaker ,point gap, spark plug gaps, clutch and others of a similar nature. No new parts or accessories can be installed without having mention made of it in the report. No data' are recorded during this preliminary run except the time that the engine is operated. BELT HORSEPOWER TESTS TEST B: The throttle …


Test 609: Mccormick Farmall 350 Diesel, Nebraska Tractor Test Lab Apr 1957

Test 609: Mccormick Farmall 350 Diesel, Nebraska Tractor Test Lab

Nebraska Tractor Tests

EXPLANATION OF TEST REPORT TEST A: The manufacturer's representative operates the tractor for a minimum of 12 hours using light to heavy drawbar loads in each gear. This serves as a period for limber up, general observation and adjustments. Adjustments that are permissible include valve tappet clearance, breaker ,point gap, spark plug gaps, clutch and others of a similar nature. No new parts or accessories can be installed without having mention made of it in the report. No data' are recorded during this preliminary run except the time that the engine is operated. BELT HORSEPOWER TESTS TEST B: The throttle …


Letters Between Us Army Assistant Chief Of Staff For Intelligence And The Surgeon General About Technical Service Intelligence Agencies, 1957, Robert L. Bolin , Depositor Apr 1957

Letters Between Us Army Assistant Chief Of Staff For Intelligence And The Surgeon General About Technical Service Intelligence Agencies, 1957, Robert L. Bolin , Depositor

United States Department of Defense Military Intelligence

This is two in a series of letters between the Army Assistant Chief of Staff for Intelligence (ACSI) and The Surgeon General (TSG) concerning the concentration of the Technical Service (TS) intelligence agencies at Arlington Hall Station. At that time the TS intelligence agencies were housed in 5 different temporary buildings around Washington, DC. In anticipation of the approval, ACSI stated that he had requested that 176,000 sq. ft. of office space be reserved at AHS.

ACSI proposed to concentrate the army Technical Service intelligence agencies at Arlington Hall Station (AHS). AHS was an army base located a few miles …


Test 608: Mccormick Farmall 450 Diesel, Nebraska Tractor Test Lab Apr 1957

Test 608: Mccormick Farmall 450 Diesel, Nebraska Tractor Test Lab

Nebraska Tractor Tests

EXPLANATION OF TEST REPORT TEST A: The manufacturer's representative operates the tractor for a minimum of 12 hours using light to heavy drawbar loads in each gear. This serves as a period for limber up, general observation and adjustments. Adjustments that are permissible include valve tappet clearance, breaker ,point gap, spark plug gaps, clutch and others of a similar nature. No new parts or accessories can be installed without having mention made of it in the report. No data' are recorded during this preliminary run except the time that the engine is operated. BELT HORSEPOWER TESTS TEST B: The throttle …


Test 607: Unimog 30 Diesel, Nebraska Tractor Test Lab Mar 1957

Test 607: Unimog 30 Diesel, Nebraska Tractor Test Lab

Nebraska Tractor Tests

EXPLANATION OF TEST REPORT TEST A: The manufacturer's representative operates the tractor for a minimum of 12 hours using light to heavy drawbar loads in each gear. This serves as a period for limber up, general observation and adjustments. Adjustments that are permissible include valve tappet clearance, breaker ,point gap, spark plug gaps, clutch and others of a similar nature. No new parts or accessories can be installed without having mention made of it in the report. No data' are recorded during this preliminary run except the time that the engine is operated. BELT HORSEPOWER TESTS TEST B: The throttle …


Initial Bibliography Of Soviet Military Medicine, 1917-1950, Medical Information And Intelligence Agency, Robert Bolin , Depositor Mar 1957

Initial Bibliography Of Soviet Military Medicine, 1917-1950, Medical Information And Intelligence Agency, Robert Bolin , Depositor

United States Department of Defense Military Intelligence

This is a author list of more than 1000 articles about Soviet military medicine with a subject index.

This compilation is an initial listing of Soviet military articles, less specialized naval and aviation topics, from the time of the Bolshevik Revolution to the outbreak of the Korean conflict as they appeared in the Quarterly Cumulative Index, Volumes 1-11 and the Quarterly Cumulative Index Medicus, Volumes 1 - 55.

The subject headings searched are listed below and constituted 20,167 entries for this thirty three year period. 887 of these entries were of Soviet origin and comprised the publications of the 1,025 …


A Survey Inspection Of Plain Corrugated Metal Pipe Arches And Multi-Plate Metal Pipe Arches In Kentucky, Eugene M. West Mar 1957

A Survey Inspection Of Plain Corrugated Metal Pipe Arches And Multi-Plate Metal Pipe Arches In Kentucky, Eugene M. West

Kentucky Transportation Center Research Report

Past observations have indicated that rusting has been rather prevalent in the large, un-paved metal drainage structures most of which have been installed since the opening of the Kentucky Rural Secondary Program in 1949. Since all of these structures are relatively new, and since rusting in any form can be considered a threat to the life of a structure, the Chief Engineer's Office, in 1954, requested that a study be made to determine the over-all frequency possible causes, and individual seriousness of this condition.

Altogether, a total of 86 of these un-paved structures were inspected. Although it would have been …


Memo On Sandstone Specifications, James H. Havens Feb 1957

Memo On Sandstone Specifications, James H. Havens

Kentucky Transportation Center Research Report

No abstract provided.


Test 632: John Deere 830 Diesel, Nebraska Tractor Test Lab Jan 1957

Test 632: John Deere 830 Diesel, Nebraska Tractor Test Lab

Nebraska Tractor Tests

No abstract provided.


Test 613: Case 311 Gasoline, Nebraska Tractor Test Lab Jan 1957

Test 613: Case 311 Gasoline, Nebraska Tractor Test Lab

Nebraska Tractor Tests

EXPLANATION OF TEST REPORT:

TEST A: The manufacturer's representative operates the tractor for a minimum of 12 hours using light to heavy drawbar loads in each gear.

This serves as a period for limber up, general observation and adjustments. Adjustments that are permissible include valve tappet clearance, breaker, point gap, spark plug gaps, clutch and others of a similar nature. No new parts or accessories can be installed without having mention made of it in the report. No data' are recorded during this preliminary run except the time that the engine is operated.

BELT HORSEPOWER TESTS