Open Access. Powered by Scholars. Published by Universities.®

Dentistry Commons™

Open Access. Powered by Scholars. Published by Universities.®

13,191 Full-Text Articles 16,035 Authors 4,501,231 Downloads 184 Institutions

All Articles in Dentistry

Faceted Search

13,191 full-text articles. Page 359 of 415.

In- Vitro Wear Of Four Cad-Cam Materials In The Uab Wear Simulating Device, Ritika Bansal 2015 University of Alabama at Birmingham

In- Vitro Wear Of Four Cad-Cam Materials In The Uab Wear Simulating Device, Ritika Bansal

All ETDs from UAB

In- vitro Wear of Four CAD- CAM Materials in the UAB Wear Simulating Device RITIKA BANSAL MS IN CLINICAL DENTISTRY ABSTRACT Hybrid ceramic/polymer blocks represent a new category of CAD/CAM materials that do not require heat treatment following milled fabrication and limited clinically relevant mechanical properties of these materials are available. Purpose: This study measures the hardness, flexural strength, modulus, and wear of 3 ceramic/polymer hybrid materials (LAVA Ultimate, Enamic, and Cerasmart), 2 reference glass ceramics (IPS e.max and Celtra Duo), and 1 reference composite material (Paradigm MZ100). Methods: Flexural strength specimens (n=10) (2.5 × 2.5 × 16 mm) were …


The Effect Of Bone-Implant Contact And Elastic Modulus In The Biomechanical Stability Of Temporary Anchorage Devices, Ghada Nimeri 2015 University of Alabama at Birmingham

The Effect Of Bone-Implant Contact And Elastic Modulus In The Biomechanical Stability Of Temporary Anchorage Devices, Ghada Nimeri

All ETDs from UAB

ABSTRACT The purpose of this study was to analyze the microstrains of compact and trabecular bone caused by loading of different miniscrews at different healing times, and to compare these results to the limits of bone stability maintenance based on the Frost Mechanostat Theory. Materials and Methods: Theoretical calculations of microstrains of bone surrounding 10 different miniscrews were done. These miniscrews were considered under loading forces of 500 gm., and the microstains of both trabecular and compact bone were calculated separately when the thickness of the compact bone was at 1mm or 2mm. The microstrains were calculated at 4 different …


Long-Term Stability Of Lefort I Maxillary Downdraft With Rigid Internal Fixation, Stephen Leonard Strickland 2015 University of Alabama at Birmingham

Long-Term Stability Of Lefort I Maxillary Downdraft With Rigid Internal Fixation, Stephen Leonard Strickland

All ETDs from UAB

ABSTRACT Objective: The objective of this study is to evaluate the skeletal and dental stability of a Le Fort I maxillary downgraft after a minimum 4year follow up period. Methods: This retrospective cohort study evaluated 18 patients' post-surgical stability after Le Fort I maxillary downgraft performed by a Z-osteotomy. Pre-surgical (T1), post-surgical (T2), post-orthodontic (T3), and long-term follow-up (T4) cephalometric radiographs were digitized and analyzed with Dolphin Imagining via a custom analysis to evaluate linear and angular skeletal and dental relapse. Results - The average Le Fort I maxillary down graft was 3.6mm. The average post-surgical orthodontic phase was 7.4 …


Three-Dimensional Age-Related Changes Of The Adult Face; African American Female Population, Christina Theresa Sutherland 2015 University of Alabama at Birmingham

Three-Dimensional Age-Related Changes Of The Adult Face; African American Female Population, Christina Theresa Sutherland

All ETDs from UAB

Objectives: Treatment of older adults is one of the fastest growing areas in orthodontic practice. The objectives of this study are to: 1. Investigate the aging of the female African American face using three-dimensional surface imaging to understand how the soft tissue of the face matures in relation to the teeth and 2.) Compare the effects of aging on African American female faces to aging of Caucasian female faces. Methods: This is a cross-sectional study of 100 African American females with balanced faces. Five age groups (in years) were included: [20-30], [31-40], [41-50], [51-60], [61-70]. Three-dimensional (3D) surface images of …


Aadej Comm 46 3 2015, 2015 American Dental Association

Aadej Comm 46 3 2015

AADEJ - The Communicator

The Communicator is the official journal of the American Association of Dental Editors and Journalists (AADEJ). It is published quarterly, distributed digitally via email to members, and posted on the Association's website, AADEJ.org. Each issue includes regular updates from the editorial team and AADEJ board, as well as feature articles on current issues in the field.


Consequences Of Trps1 Deficiency On Dentinogenesis, Morgan Goss 2015 University of Alabama at Birmingham

Consequences Of Trps1 Deficiency On Dentinogenesis, Morgan Goss

All ETDs from UAB

Dentinogenesis is a complex process of dentin formation. It involves differentiation of odontoblasts, the cells that make dentin, and the formation of a unique extracellular matrix, known as dentin. Dentin is ultimately produced through the interaction of collagen fibers, non-collagenous proteins and hydroxyapatite (HA) crystals. Odontoblasts are cranial neural crest (CNC) ectomesenchymal derived cells. Trps1 is a novel transcription factor believed to play an important role in both tooth formation and the mineralization process. TRPS1 gene mutations are known to result in dental and skeletal abnormalities manifested in humans as tricho-rhino-phalangeal syndrome (TRPS) and Ambras syndrome. Trps1 expression varies throughout …


Intra-Oral Scanning Devices Compared To Traditional Digital Impressions, Terpsithea Christou 2015 University of Alabama at Birmingham

Intra-Oral Scanning Devices Compared To Traditional Digital Impressions, Terpsithea Christou

All ETDs from UAB

The aim of this study is to review the state of art concerning 3D optical acquisition techniques and devices currently used in Orthodontics, and determine whether a commercial intra-oral scanner is as accurate as traditional impressions for orthodontic purposes. Materials and Methods: Records of 30 subjects were prospectively acquired and digital models were obtained using an intra-oral scanner, LythosTM by Ormco, and an extra-oral scanner, GOM ATOS Triple Scan II by GOM. Seven parameters indicating linear measurements from predetermined landmarks were measured and analyzed. Paired t tests, plots and bars and Bland and Altman Analysis were used to compare and …


Upper Incisors Position Changes After Orthodontic Treatment In Class I, Ii And Iii Malocclusions, Konstantinos Bakos 2015 University of Alabama at Birmingham

Upper Incisors Position Changes After Orthodontic Treatment In Class I, Ii And Iii Malocclusions, Konstantinos Bakos

All ETDs from UAB

Objective: The purpose of this study was to evaluate the maxillary central incisor position changes after orthodontic treatment in Class I, II and III malocclusions. Material and Methods: This retrospective cohort study evaluated nighty non extraction orthodontic Class I, II and III cases which were collected randomly from the Orthodontic clinic at the University of Alabama at Birmingham and the Institutional Review Board of the University of Alabama at Birmingham approved the study. All the chosen cases were treated with fixed appliances and according to the standards of American Board of Orthodontics. All the lateral cephalo-metric radiographs were taken using …


Retention Of Cad/Cam Crowns Luted With Resin Cements And Rmgi, Shruti Sushilkumar Sonavane 2015 University of Alabama at Birmingham

Retention Of Cad/Cam Crowns Luted With Resin Cements And Rmgi, Shruti Sushilkumar Sonavane

All ETDs from UAB

Objectives: To measure retention of lithium disilicate (IPS e.max CAD, Ivoclar Viva-dent) and zirconia reinforced lithium disilicate (CELTRATM DUO, Dentsply) copings luted using resin cements and resin-modified glass ionomer cement. Methods: 110 Extracted human, non-carious mandibular 2nd premolars (n=10) were embedded in PVC cylinders with acrylic resin and placed into a lathe to produce a uni-form crown preparation (22°-convergence & 3mm-height). Following the orientation groove placement (69L bur), preparations were scanned and milled using a CEREC 3D/Sirona machine to produce e.max and CELTRATM DUO crowns. Preparations were imaged with a digital microscope (Keyence/VHX-600-20X) and the surface area of each crown …


Changes In The Frontal Soft Tissue Of The Lower Face By Age And Sex, Maggie Law 2015 University of Alabama at Birmingham

Changes In The Frontal Soft Tissue Of The Lower Face By Age And Sex, Maggie Law

All ETDs from UAB

The purpose of this study is to determine age-related changes of the lower face by age and by gender. The secondary purpose of this study is to stress the importance of the clin-ical exam for orthodontic patients in the frontal view, the way most patients perceive themselves. Also, individualized treatment planning with age-appropriate incisor display is crucial for esthetic outcomes. Materials and Methods: Specific dimensions of the lower face were measured at patients initial clinical exam before starting orthodontic treatment. All patients were from Dr. David Sarver's private practice in Vestavia Hills, AL collected from 1/1/2002-11/4/2014. The following parameters were …


Comparison Of Three Fluoride Dentifrice Products In The Prevention Of White Spot Lesions In Orthodontic Treatment, Anna B. Palombini 2015 University of Alabama at Birmingham

Comparison Of Three Fluoride Dentifrice Products In The Prevention Of White Spot Lesions In Orthodontic Treatment, Anna B. Palombini

All ETDs from UAB

Introduction:. During the course of orthodontic treatment, enamel decalcification is a common problem. Demineralized enamel, the precursor to caries formation, can be attributed to fixed orthodontic appliances and prolonged exposure to bacterial plaque. Progression to clinically detectable white spot lesions may occur as early as one month following the placement of orthodontic appliances. Such problems have influenced clinicians to search for a solution. Because fluoride treatment immediately upon debonding is not advocated, clinicians have proposed fluoride treatment and fluoride-releasing materials at the commencement of the therapy. The two new anti-cavity toothpastes, ClinproTM 5000 with 1.1% Sodium Fluoride and ClinproTM Tooth …


Bond Of Dual Cure Resin Cements To Enamel And Dentin In Self Cure Mode, Rashmi Radhakrishnan 2015 University of Alabama at Birmingham

Bond Of Dual Cure Resin Cements To Enamel And Dentin In Self Cure Mode, Rashmi Radhakrishnan

All ETDs from UAB

Dual cured resin cements are frequently used to cement all ceramic restorations. The increased thickness and /or opacity of restorations block light transmission. In these situations, where little or no light can be transmitted through the restorations, the polymerization of the cement is in the self-cure mode. Purpose: This study measures the bond strength and mode of failure of dual cure resin cements to enamel and dentin in a self-cure mode using e.max rods. Methods: 160 extracted human molars were ground to mid-coronal dentin (N=80) or superficial enamel (N=80) and finished to 320 grit disks. Four adhesive/cement combinations - Multilink …


A Prospective Randomized Clinical Trial To Assess The Performance Of Microtextured Dental Implants With Or Without A Machined Collar- 1 Year Results, Elizabeth Felts Randall 2015 University of Alabama at Birmingham

A Prospective Randomized Clinical Trial To Assess The Performance Of Microtextured Dental Implants With Or Without A Machined Collar- 1 Year Results, Elizabeth Felts Randall

All ETDs from UAB

Aim: To assess the performance of microtextured dental implants with or without a machined collar at one year after placement. Material and Methods: Fifty-eight patients received dental implant therapy to restore missing teeth in one area of the maxilla or man-dible at the UAB Department of Graduate Periodontology. Residents in the program placed microtextured implants with a microtextured collar with microgrooves (test group) and microtextured implants with a machined collar (control group). Sites were randomized to the test group or control group. Study visit protocol was followed and implants were restored by off-site dentists. Sixty-nine (69) implants were assessed at …


Perceptions Of Facial Attractiveness: Outcomes Of Orthognathic Surgery, Brittany Bross Reid 2015 University of Alabama at Birmingham

Perceptions Of Facial Attractiveness: Outcomes Of Orthognathic Surgery, Brittany Bross Reid

All ETDs from UAB

PERCEPTIONS OF FACIAL ATTRACTIVENESS: OUTCOMES OF ORTHOGNATHIC SURGERY BRITTANY REID DEPARTMENT OF ORTHODONTICS ABSTRACT Perceptions of physical attractiveness contribute to generalized assumptions that can create significant bias in social decision-making. Because these biases exist, patients often seek ways to improve facial harmony and overall appearance. Orthodontics and orthognathic surgery are treatment modalities that may be considered as a means to achieve facial balance. Orthodontists and oral surgeons must have an understanding of facial beauty and how to properly carry out techniques in order to preserve or improve facial balance. More importantly, the treatment goals of the patient and clinician(s) must …


Characterization Of Oral Microbiota In Xerostomic Versus Non-Xerostomic Volunteers And In Daily Samples Following Standard Oral Hygiene Practices, Chelsea Myers 2015 Wayne State University

Characterization Of Oral Microbiota In Xerostomic Versus Non-Xerostomic Volunteers And In Daily Samples Following Standard Oral Hygiene Practices, Chelsea Myers

Wayne State University Theses

A thesis presented on the characterization of oral microbiota in xerostomic versus non-xerostomic volunteers and in daily samples following standard oral hygiene practices. Xerostomia is a difficult and burdensome disease that can be very difficult to diagnose. Understanding the oral microbiota between these diseased and healthy (non-xerostomic) can give us great insight on new treatments and/or prevention. Goals of the study included determining whether there substantial differences in oral microbial populations between the two groups, and whether varying nightly oral hygiene practices had an impact on next-morning oral microbiota titers or composition. Microbial loads were determined by qPCR using broad-spectrum …


Esthetic Preferences Of Maxillary Incisor Labiolingual Inclination Across Races, Elvi M. Barcoma 2015 Department of Orthodontics

Esthetic Preferences Of Maxillary Incisor Labiolingual Inclination Across Races, Elvi M. Barcoma

Theses and Dissertations

Abstract

ESTHETIC PREFERENCES FOR MAXILLARY INCISOR LABIOLINGUAL INCLINATION ACROSS RACES

by Elvi Marie Barcoma, D.D.S.

A thesis submitted in partial fulfillment of the requirements for the degree of Master of Science in Dentistry at Virginia Commonwealth University

Virginia Commonwealth University, 2015

Major Director: Bhavna Shroff, D.M.D., M.Dent.Sc, Program Director, Orthodontics

Objective: To determine if people of different racial backgrounds prefer different amounts of

maxillary incisor labiolingual inclination from a smiling profile view.

Materials and Methods: An electronic survey was created with smiling profile images of an African-American female and a White female with varying degrees of maxillary incisor labiolingual inclination. …


Restorative Characteristics Of Intrapulpally Cracked Teeth, Charles M. Beavers 2015 VCU

Restorative Characteristics Of Intrapulpally Cracked Teeth, Charles M. Beavers

Theses and Dissertations

Cracked teeth have long presented a diagnostic challenge. Previous investigators have considered possible predictive factors, many of which revolve around the tooth’s restorative characteristics. Few have investigated the restorative status of teeth with cracks extending into the pulp chamber. The purpose of this investigation was to determine the prevalence of the different types of restorations present in intrapulpally cracked teeth and determine any other restorative factors that may aid in predicting the presence or extent of an intrapulpal crack. Intrapulpally cracked molars requiring endodontic therapy at the VCU Graduate Endodontic Practice were included in this study. For each tooth, the …


In-Vitro Assessment Of A Novel Bracket's Effect On Resistance To Sliding, James Blackburn 2015 Virginia Commonwealth University

In-Vitro Assessment Of A Novel Bracket's Effect On Resistance To Sliding, James Blackburn

Theses and Dissertations

Friction, binding and notching are the factors that contribute to resistance to sliding during orthodontic tooth movement. However, most attempts at reducing resistance aim only to reduce the archwire/ligature friction. In this study, a novel bracket with a unique design aimed to reduce all three components of resistance to sliding. Four types of brackets (passive and active self-ligating, traditionally ligated and the novel bracket, (n=5, each) were tested at 0, 2, 4, 6, and 8ᵒ of tip on a 0.019 x 0.025”archwire. The resistance to sliding values were recorded. At 0ᵒ, the passive self-ligating and novel bracket showed reduced resistance …


Treatment Decisions Involving Teeth With Intrapulpal Cracks: A Survey Of Endodontists, Sheldon M. Sealey 2015 Virginia Commonwealth University

Treatment Decisions Involving Teeth With Intrapulpal Cracks: A Survey Of Endodontists, Sheldon M. Sealey

Theses and Dissertations

There is no universal protocol for diagnosing, treating and managing cracked teeth. The purpose of this survey was to investigate the use of traditional methods of crack detection and to explore how treatment decisions were made using an intrapulpal crack classification. The electronic survey was sent to 1115 active members of the American Association of Endodontists (AAE) and The Digital Office (TDO™) community. Comparisons were assessed using logistic or repeated-measures regression. The most often used diagnostic method was probing. When the crack involved one wall, 85% of respondents would complete root canal therapy > 50% of the time or …


Peracetic Acid: A Practical Agent For Sterilizing Heat-Labile Polymeric Tissue-Engineering Scaffolds, William R. Trahan 2015 Virginia Commonwealth University

Peracetic Acid: A Practical Agent For Sterilizing Heat-Labile Polymeric Tissue-Engineering Scaffolds, William R. Trahan

Theses and Dissertations

Advanced biomaterials and sophisticated processing technologies aim to fabricate tissue-engineering scaffolds that can predictably interact within a biological environment at a cellular level. Sterilization of such scaffolds is at the core of patient safety and is an important regulatory issue that needs to be addressed prior to clinical translation. In addition, it is crucial that meticulously engineered micro- and nano- structures are preserved after sterilization. Conventional sterilization methods involving heat, steam and radiation are not compatible with engineered polymeric systems because of scaffold degradation and loss of architecture. Using electrospun scaffolds made from polycaprolactone (PCL), a low melting polymer, and …


Digital Commons powered by bepress