The Impact Of Dubai’S Architectural Wonders On The Daily Indigenous Performance In Light Of Cultural Modernity: A Comparative Case Study Between Burj Khalifa And Burj Al-Arab,
2016
United Arab Emirates University
The Impact Of Dubai’S Architectural Wonders On The Daily Indigenous Performance In Light Of Cultural Modernity: A Comparative Case Study Between Burj Khalifa And Burj Al-Arab, Zulfat S. Al Kassim
Theses
In order to decrease the reliance on oil and create more economic opportunities, the UAE has witnessed a development boom over the last few decades in an effort to promote tourism. Dubai specifically has purposefully undergone dramatic architectural evolutions with the aim of transforming the city into a tourist hub and a global attraction. Over the last few years, iconic buildings including Burj Al Arab and Burj Khalifa have been built at different times to become prominent landmarks that promote the city’s global image and combine traditional/local elements in such a way as to form completely new unrecognizable forms i.e. …
Post-Repair Seismic Assessment Of Rc Bridges Damaged With Fractured Column Bars - A Numerical Approach,
2016
Missouri University of Science and Technology
Post-Repair Seismic Assessment Of Rc Bridges Damaged With Fractured Column Bars - A Numerical Approach, Ruili He, Yang Yang, Lesley H. Sneed
Civil, Architectural and Environmental Engineering Faculty Research & Creative Works
Seismic repair of reinforced concrete (RC) bridge columns has been studied extensively during the past several decades; however, few studies have been conducted on the influence of the column repair (member level) on the post-repair performance of bridge structures (system level). In a previous experimental study by the authors, a method was developed to rapidly repair severely damaged RC bridge columns to enable the quick reopening of the bridge to emergency traffic. Thus, a lower limit state was used for the repair design, so that the lateral strength and drift capacity of a repaired RC column with fractured longitudinal bars …
Model For Coupled Large Strain Consolidation And Solute Transport In Layered Soils,
2016
Missouri University of Science and Technology
Model For Coupled Large Strain Consolidation And Solute Transport In Layered Soils, Hefu Pu, Patrick J. Fox
Civil, Architectural and Environmental Engineering Faculty Research & Creative Works
A numerical model, called CST3 (Consolidation and Solute Transport 3), is presented for coupled one-dimensional large strain consolidation and solute transport in layered soils. The consolidation algorithm accounts for vertical strain, soil self-weight, general constitutive relationships, relative velocity of fluid and solid phases, changing compressibility and hydraulic conductivity during consolidation, unload/reload, time-dependent loading and boundary conditions, external hydraulic gradient, variable preconsolidation stress profiles, and multiple soil layers with different material properties. The solute transport algorithm accounts for advection, diffusion, mechanical dispersion, linear and nonlinear sorption, equilibrium and nonequilibrium sorption, porosity-dependent effective diffusion coefficient, and first-order decay reactions. CST3 is based …
Evaluation Of Carbonation Resistance Of Paint Coated Concrete For Buildings,
2016
Missouri University of Science and Technology
Evaluation Of Carbonation Resistance Of Paint Coated Concrete For Buildings, Tommy Y. Lo, Wenyu Liao, C. K. Wong, Waiching Tang
Civil, Architectural and Environmental Engineering Faculty Research & Creative Works
When evaluating the carbonation resistance of paint coated concrete, the effects of both the strength grade and the curing conditions (standard curing and accelerated curing) of concrete substrate on carbonation resistance of paint coated concrete were investigated. The concept of the carbonation suppression ratio of paint was presented for evaluation of the anti-carbonation performance of the two types of paints (exterior and interior paints) when applied to a reference concrete substrate. The test results showed a good linear relationship between the carbonation depths of the paint coated concrete and the square root of exposure times. Concrete with higher strength grade …
The Function And Format Of Bills Of Quantities:An Irish Context,
2016
Technological University Dublin
The Function And Format Of Bills Of Quantities:An Irish Context, Tony Cunningham
Other Resources
The production of bills of quantities as a means of obtaining tenders has traditionally been viewed as a primary function of the quantity surveying profession.
This study investigates the function and format of bills of quantities in the Irish context. It explains the nature of bills, how they are compiled, and identifies the situations in which they may be used. The primary functions of the bill as a means of obtaining tenders and its status as a contract document are explored. The study also addresses particular aspects of the bill which may aid the effective management of construction projects for …
Ua66 Ogden College Of Science & Engineering Newsletter,
2016
Western Kentucky University
Ua66 Ogden College Of Science & Engineering Newsletter, Cheryl Stevens, Dean
Ogden College of Science & Engineering Publications
No abstract provided.
Structural Damage Detection By Comparison Of Experimental And Theoretical Mode Shapes,
2016
California Polytechnic State University, San Luis Obispo
Structural Damage Detection By Comparison Of Experimental And Theoretical Mode Shapes, William George Rosenblatt
Master's Theses
Existing methods of evaluating the structural system of a building after a seismic event consist of removing architectural elements such as drywall, cladding, insulation, and fireproofing. This method is destructive and costly in terms of downtime and repairs. This research focuses on removing the guesswork by using forced vibration testing (FVT) to experimentally determine the health of a building. The experimental structure is a one-story, steel, bridge-like structure with removable braces. An engaged brace represents a nominal and undamaged condition; a dis-engaged brace represents a brace that has ruptured thus changing the stiffness of the building. By testing a variety …
Experimental Study On The Thermal Characteristics Of Micro Channel Separate Heat Pipe Respect To Different Filling Ratio,
2016
Hunan University
Experimental Study On The Thermal Characteristics Of Micro Channel Separate Heat Pipe Respect To Different Filling Ratio, Li Ling, Quan Zhang, Yuebin Yu, Shuguang Liao, Zhengyong Sha
Durham School of Architectural Engineering and Construction: Faculty Publications
A micro channel separate heat pipe (MCSHP) that can use natural cold energy was developed to reduce the cooling energy consumptions of telecommunications stations (TSs). Experimental investigations of exploring the optimal refrigerant filling ratio of MCSHP under different outdoor conditions and flow rates were presented. R22 was used as the working fluid. Various refrigerant filling ratios were tested in an enthalpy difference laboratory (EDL) in order to determine the optimal thermal performance for the exterior space temperature range from 8 °C to 23 °C and the air volume flow rate range from 1712 m3/h to 2980 m3/h. In addition, transient …
Thermal Mass Behaviour Of Concrete Panels Incorporating Phase Change Materials,
2016
Technological University Dublin
Thermal Mass Behaviour Of Concrete Panels Incorporating Phase Change Materials, Dervilla Niall, Roger West, Sarah Mccormack, Oliver Kinnane
Conference papers
Phase Change Materials (PCM) have been incorporated into a range of building envelope materials with varied success. This study investigates two different methods of combining concrete and phase change materials to form PCM/concrete composite panels. The first method involves adding microencapsulated paraffin to fresh concrete during the mixing process. The second method involves vacuum impregnating butyl stearate into lightweight aggregate which is then included in the concrete mix design. The primary aim of the study is to determine which method is the most effective way to improve the thermal mass characteristics of a concrete panel in the context of a …
Engineering Behavior And Characteristics Of Water-Soluble Polymers: Implication On Soil Remediation And Enhanced Oil Recovery,
2016
Missouri University of Science and Technology
Engineering Behavior And Characteristics Of Water-Soluble Polymers: Implication On Soil Remediation And Enhanced Oil Recovery, Shuang Cindy Cao, Bate Bate, Jong Wan Hu, Jongwon Jung
Civil, Architectural and Environmental Engineering Faculty Research & Creative Works
Biopolymers have shown a great effect in enhanced oil recovery because of the improvement of water-flood performance by mobility control, as well as having been considered for oil contaminated-soil remediation thanks to their mobility control and water-flood performance. This study focused on the wettability analysis of biopolymers such as chitosan (85% deacetylated power), PEO (polyethylene oxide), Xanthan (xanthan gum), SA (Alginic Acid Sodium Salt), and PAA (polyacrylic acid), including the measurements of contact angles, interfacial tension, and viscosity. Furthermore, a micromodel study was conducted to explore pore-scale displacement phenomena during biopolymer injection into the pores. The contact angles of biopolymer …
The Bridge Newsletter Spring 2016,
2016
Missouri University of Science and Technology
The Bridge Newsletter Spring 2016, Missouri University Of Science And Technology
The Bridge Newsletter
-Steel Bridge Team qualifies for nationals
-Concrete, reimagined
-Going with the flow
-Remembering Vernon T. Jones
Case Study Of Quantifying Energy Loss Through Ceiling-Attic Recessed Lighting Fixtures Through 3d Numerical Simulation,
2016
University of Nebraska - Lincoln
Case Study Of Quantifying Energy Loss Through Ceiling-Attic Recessed Lighting Fixtures Through 3d Numerical Simulation, Ri Na, Shengmao Lin, Zhigang Shen, Linxia Gu
Durham School of Architectural Engineering and Construction: Faculty Publications
Air leakage through improperly installed recessed lighting fixtures has been identified as a common issue causing extra energy consumption of residential buildings. However, little quantitative study was found in this area. In this paper, a preliminary evaluation of the magnitude of such energy loss was conducted by numerical simulations using 3 dimensional transient computational fluid dynamics (CFD) model. A typical layout of recessed lighting fixtures was used in this case study with boundary conditions in four different seasons, which were obtained from past measured roof/attic temperature data sets. The results of the numerical simulations indicate that leakage of recessed lighting …
Designing A Residence In Sweden,
2016
Stephen F Austin State University
Designing A Residence In Sweden, Umeki Earl, Olivia Bufalini
School of Human Sciences Research Showcase
The project was to design a home for the Nordstroms, a family who lived in Sweden. The challenge was to design a home for the family of four with a maximum square footage of 1100 square feet using the codes and space allocations required for another country. Meeting the needs of the client required much research. RESEARCH included studying the regional climate, the municipal building codes, and city regulations. Thorough research of building construction framing methods, insulation types and installation methods, site planning, materials and finishes were also essential for completing the project.
2016 Scholarly Productivity Report,
2016
Missouri University of Science and Technology
2016 Scholarly Productivity Report, Missouri University Of Science And Technology
Civil, Architectural and Environmental Engineering Scholarly Productivity Reports
No abstract provided.
A Need For Evidence-Based And Multidisciplinary Research
To Study The Effects Of The Interaction Of School Environmental
Conditions On Student Achievement,
2016
University of Nebraska-Lincoln
A Need For Evidence-Based And Multidisciplinary Research To Study The Effects Of The Interaction Of School Environmental Conditions On Student Achievement, Josephine Lau, Lily M. Wang, Clarence E. Waters, James A. Bovaird
Durham School of Architectural Engineering and Construction: Faculty Publications
With funding from the U.S. Environmental Protection Agency’s (EPA) Healthy Schools initiative, a research team from the University of Nebraska– Lincoln (UNL) is currently working on establishing how environmental conditions in K-12 school buildings impact student scholastic achievement. The objectives of the research project are: (1) to study comprehensively the impacts of a wide set of indoor environmental factors (including indoor air quality, thermal, lighting and acoustic conditions) on student achievement; (2) to investigate how these environmental conditions interact with each other to impact student achievement; (3) to rank order the environmental variables in terms of their relative impact on …
Cognitive Radio For Smart Grid With Security Considerations,
2016
United Arab Emirates University
Cognitive Radio For Smart Grid With Security Considerations, Khaled Shuaib, Ezedin Barka, Nedaa Al Hussien, Mohammed Abdel-Hafez, Mahmoud Alahmad
Durham School of Architectural Engineering and Construction: Faculty Publications
In this paper, we investigate how Cognitive Radio as a means of communication can be utilized to serve a smart grid deployment end to end, from a home area network to power generation. We show how Cognitive Radio can be mapped to integrate the possible different communication networks within a smart grid large scale deployment. In addition, various applications in smart grid are defined and discussed showing how Cognitive Radio can be used to fulfill their communication requirements. Moreover, information security issues pertained to the use of Cognitive Radio in a smart grid environment at different levels and layers are …
Normalized Effect Of Condenser Fouling And
Refrigerant Charge On Performance Of Vapor
Compression Air Conditioning Systems,
2016
University of Nebraska - Lincoln
Normalized Effect Of Condenser Fouling And Refrigerant Charge On Performance Of Vapor Compression Air Conditioning Systems, Mehdi Mehrabi, David Yuill
Durham School of Architectural Engineering and Construction: Faculty Publications
Several laboratory experiments have studied the effect of faults on vapor compression cycle air-conditioning systems. There has been a particular focus on refrigerant charge variation, which is believed to be quite common in air conditioners, and a lesser focus on heat exchanger fouling. The majority of the published results evaluate the fault effects on particular system operating parameters in one unit. For example, the effect on capacity and efficiency are typically evaluated. The results differ from one study to the next. The current paper summarizes the effects for all of the results available in the literature for condenser fouling and …
Divisible Cities,
2016
Technological University Dublin
No Reduction By Propane Over Monolithic Cordierite-Based Fe/Al2o3 Catalyst: Reaction Mechanism And Effect Of H2o/So2,
2016
Missouri University of Science and Technology
No Reduction By Propane Over Monolithic Cordierite-Based Fe/Al2o3 Catalyst: Reaction Mechanism And Effect Of H2o/So2, Hao Zhou, Yaxin Su, Wenyu Liao, Wenyi Deng, Fangchuan Zhong
Civil, Architectural and Environmental Engineering Faculty Research & Creative Works
The selective reduction of NO by C3H8and the sensitivity to H2O and SO2have been studied over monolithic cordierite-based Fe/Al2O3catalysts, which were prepared by the sol–gel and impregnation method. The catalysts were investigated by N2 adsorption, X-ray diffraction (XRD), scanning electron microscope (SEM), X-ray photoelectron spectroscopy (XPS) and in situ diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) techniques. Results showed that NO reduction was more than 90% in the absence of oxygen at 500 °C and in the presence of oxygen at 600 °C respectively. In a continues …
Development Of Coordination Control For Multiple Rooftop Units,
2016
Sripatum University
Development Of Coordination Control For Multiple Rooftop Units, Denchai Woradechjumroen, Haorong Li, Akekachai Deesiri
Durham School of Architectural Engineering and Construction: Faculty Publications
Rooftop Units (RTUs) have been widely applied in providing space heating and cooling for commercial buildings. In total, they serve over 60% of the commercial building floor space in the U.S. Even through the current control approaches of a RTU can maintain the zone temperature corresponding to a set point temperature, it performs inefficiently due to several factors such as limited sensing capability, non- coordinated local control, inherent oversizing effects and so on. In addition to unnecessary power consumptions, the current control and operation technology on RTUs also lead to the space humidity problem, equipment efficiency degradation, and premature failure. …