Full-Text Articles in Health and Medical Physics

Compensation Cycle Consistent Generative Adversarial Networks (Comp-Gan) For Synthetic Ct Generation From Mr Scans With Truncated Anatomy, Yao Zhao, He Wang, Cenji Yu, Laurence E Court, Xin Wang, Qianxia Wang, Tinsu Pan, Yao Ding, Jack Phan, Jinzhong Yang Jul 2023

Compensation Cycle Consistent Generative Adversarial Networks (Comp-Gan) For Synthetic Ct Generation From Mr Scans With Truncated Anatomy, Yao Zhao, He Wang, Cenji Yu, Laurence E Court, Xin Wang, Qianxia Wang, Tinsu Pan, Yao Ding, Jack Phan, Jinzhong Yang

Faculty, Staff and Student Publications

BACKGROUND: MR scans used in radiotherapy can be partially truncated due to the limited field of view (FOV), affecting dose calculation accuracy in MR-based radiation treatment planning.

PURPOSE: We proposed a novel Compensation-cycleGAN (Comp-cycleGAN) by modifying the cycle-consistent generative adversarial network (cycleGAN), to simultaneously create synthetic CT (sCT) images and compensate the missing anatomy from the truncated MR images.

METHODS: Computed tomography (CT) and T1 MR images with complete anatomy of 79 head-and-neck patients were used for this study. The original MR images were manually cropped 10-25 mm off at the posterior head to simulate clinically truncated MR images. Fifteen …


Ai-Enabled Online Plan Adaptation For Mr-Guided Stereotactic Ablative Radiotherapy (Sabr) Of Head And Neck Cancer, Yao Zhao Jun 2023

Ai-Enabled Online Plan Adaptation For Mr-Guided Stereotactic Ablative Radiotherapy (Sabr) Of Head And Neck Cancer, Yao Zhao

Dissertations and Theses (Open Access)

Head and neck cancer (HNC) is a prevalent cancer type worldwide. Stereotactic ablative radiotherapy (SABR) has emerged as an effective treatment for HNC, delivering highly conformal doses to the tumor target while sparing surrounding normal tissues with a sharp dose gradient. However, the accuracy of the treatment delivery is limited by setup errors, anatomical changes, and intra-/inter-fraction organ motion. The emergence of MR-guided adaptive radiotherapy (ART) has the potential to further improve the SABR of HNC, by providing superior visualization of soft tissue and enabling real-time plan adaptation based on the daily anatomical changes of patients. This novel technology has …


A Virtual Audit System For Intensity-Modulated Radiation Therapy Credentialing In Japan Clinical Oncology Group Clinical Trials: A Pilot Study, Mitsuhiro Nakamura, Dejun Zhou, Toshiyuki Minemura, Satoshi Kito, Hiroyuki Okamoto, Naoki Tohyama, Masahiko Kurooka, Yu Kumazaki, Masayori Ishikawa, Catharine H Clark, Elizabeth Miles, Joerg Lehmann, Nicolaus Andratschke, Stephen Kry, Satoshi Ishikura, Takashi Mizowaki, Teiji Nishio Jun 2023

A Virtual Audit System For Intensity-Modulated Radiation Therapy Credentialing In Japan Clinical Oncology Group Clinical Trials: A Pilot Study, Mitsuhiro Nakamura, Dejun Zhou, Toshiyuki Minemura, Satoshi Kito, Hiroyuki Okamoto, Naoki Tohyama, Masahiko Kurooka, Yu Kumazaki, Masayori Ishikawa, Catharine H Clark, Elizabeth Miles, Joerg Lehmann, Nicolaus Andratschke, Stephen Kry, Satoshi Ishikura, Takashi Mizowaki, Teiji Nishio

Faculty, Staff and Student Publications

Purpose: The Medical Physics Working Group of the Radiation Therapy Study Group at the Japan Clinical Oncology Group is currently developing a virtual audit system for intensity-modulated radiation therapy dosimetry credentialing. The target dosimeters include films and array detectors, such as ArcCHECK (Sun Nuclear Corporation, Melbourne, Florida, USA) and Delta4 (ScandiDos, Uppsala, Sweden). This pilot study investigated the feasibility of our virtual audit system using previously acquired data.

Methods: We analyzed 46 films (32 and 14 in the axial and coronal planes, respectively) from 29 institutions. Global gamma analysis between measured and planned dose distributions used the following settings: 3%/3 …


Aapm Task Group Report 305: Guidance For Standardization Of Vendor-Neutral Reject Analysis In Radiography, Kevin Little, Ingrid Reiser, Bruce Apgar, Poonam Dalal, Jaydev Dave, Ryan Fisher, Katie Hulme, Mary Ellen Jafari, Emily Marshall, Stephen Meyer, Quentin Moore, Nicole Murphy, Thomas Nishino, Katelyn Nye, Kevin O'Donnell, John Sabol, Adrian Sanchez, William Sensakovic, Lawrence Tarbox, Robert Uzenoff, Alisa Walz-Flannigan, Charles Willis, Jie Zhang May 2023

Aapm Task Group Report 305: Guidance For Standardization Of Vendor-Neutral Reject Analysis In Radiography, Kevin Little, Ingrid Reiser, Bruce Apgar, Poonam Dalal, Jaydev Dave, Ryan Fisher, Katie Hulme, Mary Ellen Jafari, Emily Marshall, Stephen Meyer, Quentin Moore, Nicole Murphy, Thomas Nishino, Katelyn Nye, Kevin O'Donnell, John Sabol, Adrian Sanchez, William Sensakovic, Lawrence Tarbox, Robert Uzenoff, Alisa Walz-Flannigan, Charles Willis, Jie Zhang

Faculty, Staff and Student Publications

Reject rate analysis is considered an integral part of a diagnostic radiography quality control (QC) program. A rejected image is a patient radiograph that was not presented to a radiologist for diagnosis and that contributes unnecessary radiation dose to the patient. Reject rates that are either too high or too low may suggest systemic department shortcomings in QC mechanisms. Due to the lack of standardization, reject data often cannot be easily compared between radiography systems from different vendors. The purpose of this report is to provide guidance to help standardize data elements that are required for comprehensive reject analysis and …


Monte Carlo-Derived 99m Tc Uptake Quantification With Commercial Planar Mbi: Absolute Tumor Activity, Benjamin P Lopez, Srinivas Cheenu Kappadath May 2023

Monte Carlo-Derived 99m Tc Uptake Quantification With Commercial Planar Mbi: Absolute Tumor Activity, Benjamin P Lopez, Srinivas Cheenu Kappadath

Faculty, Staff and Student Publications

BACKGROUND: Molecular breast imaging (MBI) of 99mTc-sestamibi is an emerging adjunct qualitative tool in the detection and diagnosis of breast cancer.

PURPOSE: This work outlines the development and performance evaluation of a methodology to absolutely quantify tumor 99mTc activity uptake using a commercially available dual-headed MBI system by implementing corrections for background, scatter, attenuation, and detector characteristics.

METHODS: A validated Monte Carlo application of a commercial MBI system was used to simulate over 7000 unique acquisitions of spherical and ellipsoidal tumors in breast tissue. Tumor absolute activity was calculated following background, scatter, and attenuation corrections of tumor region of interest …


Treatment Planning Automation For Rectal Cancer Radiotherapy, Kai Huang May 2023

Treatment Planning Automation For Rectal Cancer Radiotherapy, Kai Huang

Dissertations and Theses (Open Access)

Background

Rectal cancer is a common type of cancer. There is an acute health disparity across the globe where a significant population of the world lack adequate access to radiotherapy treatments which is a part of the standard of care for rectal cancers. Safe radiotherapy treatments require specialized planning expertise and are time-consuming and labor-intensive to produce.

Purpose:

To alleviate the health disparity and promote the safe and quality use of radiotherapy in treating rectal cancers, the entire treatment planning process needs to be automated. The purpose of this project is to develop automated solutions for the treatment planning process …


A Model For Gastrointestinal Tract Motility In A 4d Imaging Phantom Of Human Anatomy, Ergys Subashi, Paul Segars, Harini Veeraraghavan, Joseph Deasy, Neelam Tyagi May 2023

A Model For Gastrointestinal Tract Motility In A 4d Imaging Phantom Of Human Anatomy, Ergys Subashi, Paul Segars, Harini Veeraraghavan, Joseph Deasy, Neelam Tyagi

Faculty, Staff and Student Publications

BACKGROUND: Gastrointestinal (GI) tract motility is one of the main sources for intra/inter-fraction variability and uncertainty in radiation therapy for abdominal targets. Models for GI motility can improve the assessment of delivered dose and contribute to the development, testing, and validation of deformable image registration (DIR) and dose-accumulation algorithms.

PURPOSE: To implement GI tract motion in the 4D extended cardiac-torso (XCAT) digital phantom of human anatomy.

MATERIALS AND METHODS: Motility modes that exhibit large amplitude changes in the diameter of the GI tract and may persist over timescales comparable to online adaptive planning and radiotherapy delivery were identified based on …


Combining Physics-Based Models With Deep Learning Image Synthesis And Uncertainty In Intraoperative Cone-Beam Ct Of The Brain, Xiaoxuan Zhang, Alejandro Sisniega, Wojciech B Zbijewski, Junghoon Lee, Craig K Jones, Pengwei Wu, Runze Han, Ali Uneri, Prasad Vagdargi, Patrick A Helm, Mark Luciano, William S Anderson, Jeffrey H Siewerdsen May 2023

Combining Physics-Based Models With Deep Learning Image Synthesis And Uncertainty In Intraoperative Cone-Beam Ct Of The Brain, Xiaoxuan Zhang, Alejandro Sisniega, Wojciech B Zbijewski, Junghoon Lee, Craig K Jones, Pengwei Wu, Runze Han, Ali Uneri, Prasad Vagdargi, Patrick A Helm, Mark Luciano, William S Anderson, Jeffrey H Siewerdsen

Faculty, Staff and Student Publications

BACKGROUND: Image-guided neurosurgery requires high localization and registration accuracy to enable effective treatment and avoid complications. However, accurate neuronavigation based on preoperative magnetic resonance (MR) or computed tomography (CT) images is challenged by brain deformation occurring during the surgical intervention.

PURPOSE: To facilitate intraoperative visualization of brain tissues and deformable registration with preoperative images, a 3D deep learning (DL) reconstruction framework (termed DL-Recon) was proposed for improved intraoperative cone-beam CT (CBCT) image quality.

METHODS: The DL-Recon framework combines physics-based models with deep learning CT synthesis and leverages uncertainty information to promote robustness to unseen features. A 3D generative adversarial network …


Dose Calculation And Prediction Methods For Gamma Knife Stereotactic Radiosurgery, Payton Hayes Stone Apr 2023

Dose Calculation And Prediction Methods For Gamma Knife Stereotactic Radiosurgery, Payton Hayes Stone

LSU Doctoral Dissertations

Implementation of automation routines leveraging deep learning (DL) methods has been a growing topic of interest. The focus of this work is on the Gamma Knife (GK) workflow, specifically the approximation of dose distributions from GK plan parameters and the prediction of dose distributions using DL. These works contribute towards the larger goal of treatment plan prediction and are seen as intermediate steps towards that end. The approximation of dose distributions was motivated by the closed nature of the GK system, which causes complications with the evaluation of the predictions made by the DL models. The approximation utilizes a superposition …


Quality Assurance Assessment Of Intra-Acquisition Diffusion-Weighted And T2-Weighted Magnetic Resonance Imaging Registration And Contour Propagation For Head And Neck Cancer Radiotherapy, Mohamed A Naser, Kareem A Wahid, Sara Ahmed, Vivian Salama, Cem Dede, Benjamin W Edwards, Ruitao Lin, Brigid Mcdonald, Travis C Salzillo, Renjie He, Yao Ding, Moamen Abobakr Abdelaal, Daniel Thill, Nicolette O'Connell, Virgil Willcut, John P Christodouleas, Stephen Y Lai, Clifton D Fuller, Abdallah S R Mohamed Apr 2023

Quality Assurance Assessment Of Intra-Acquisition Diffusion-Weighted And T2-Weighted Magnetic Resonance Imaging Registration And Contour Propagation For Head And Neck Cancer Radiotherapy, Mohamed A Naser, Kareem A Wahid, Sara Ahmed, Vivian Salama, Cem Dede, Benjamin W Edwards, Ruitao Lin, Brigid Mcdonald, Travis C Salzillo, Renjie He, Yao Ding, Moamen Abobakr Abdelaal, Daniel Thill, Nicolette O'Connell, Virgil Willcut, John P Christodouleas, Stephen Y Lai, Clifton D Fuller, Abdallah S R Mohamed

Faculty, Staff and Student Publications

BACKGROUND/PURPOSE: Adequate image registration of anatomical and functional magnetic resonance imaging (MRI) scans is necessary for MR-guided head and neck cancer (HNC) adaptive radiotherapy planning. Despite the quantitative capabilities of diffusion-weighted imaging (DWI) MRI for treatment plan adaptation, geometric distortion remains a considerable limitation. Therefore, we systematically investigated various deformable image registration (DIR) methods to co-register DWI and T2-weighted (T2W) images.

MATERIALS/METHODS: We compared three commercial (ADMIRE, Velocity, Raystation) and three open-source (Elastix with default settings [Elastix Default], Elastix with parameter set 23 [Elastix 23], Demons) post-acquisition DIR methods applied to T2W and DWI MRI images acquired during the same …


Quantification Of The Role Of Lead Foil In Flattening Filter Free Beam Reference Dosimetry, Song Gao, Christopher Nelson, Congjun Wang, Vindu Kathriarachchi, Michael Choi, Rishik Saxena, Robin Kendall, Peter Balter Apr 2023

Quantification Of The Role Of Lead Foil In Flattening Filter Free Beam Reference Dosimetry, Song Gao, Christopher Nelson, Congjun Wang, Vindu Kathriarachchi, Michael Choi, Rishik Saxena, Robin Kendall, Peter Balter

Faculty, Staff and Student Publications

PURPOSE: To quantify the potential error in outputs for flattening filter free (FFF) beams associated with use of a lead foil in beam quality determination per the addendum protocol for TG-51, we examined differences in measurements of the beam quality conversion factor k

METHODS: Two FFF beams, a 6 MV FFF and a 10 MV FFF, were calibrated on eight Varian TrueBeams and two Elekta Versa HD linear accelerators (linacs) according to the TG-51 addendum protocol by using Farmer ionization chambers [TN 30013 (PTW) and SNC600c (Sun Nuclear)] with traceable absorbed dose-to-water calibrations. In determining k

RESULTS: Differences in %dd(10)x …


Impact Of Dose Calculation Accuracy On Inverse Linear Energy Transfer Optimization For Intensity-Modulated Proton Therapy, Mei Chen, Wenhua Cao, Pablo Yepes, Fada Guan, Falk Poenisch, Cheng Xu, Jiayi Chen, Yupeng Li, Ivan Vazquez, Ming Yang, X Ronald Zhu, Xiaodong Zhang Mar 2023

Impact Of Dose Calculation Accuracy On Inverse Linear Energy Transfer Optimization For Intensity-Modulated Proton Therapy, Mei Chen, Wenhua Cao, Pablo Yepes, Fada Guan, Falk Poenisch, Cheng Xu, Jiayi Chen, Yupeng Li, Ivan Vazquez, Ming Yang, X Ronald Zhu, Xiaodong Zhang

Faculty, Staff and Student Publications

Objective: To determine the effect of dose calculation accuracy on inverse linear energy transfer (LET) optimization for intensity-modulated proton therapy, and to determine whether adding more beams would improve the plan robustness to different dose calculation engines.

Methods: Two sets of intensity-modulated proton therapy plans using two, four, six, and nine beams were created for 10 prostate cancer patients: one set was optimized with dose constraints (DoseOpt) using the pencil beam (PB) algorithm, and the other set was optimized with additional LET constraints (LETOpt) using the Monte Carlo (MC) algorithm. Dose distributions of DoseOpt plans were then recalculated using the …


Aapm Medical Physics Practice Guideline 13a: Hdr Brachytherapy, Part A, Susan L Richardson, Ivan M Buzurovic, Gil'ad N Cohen, Wesley S Culberson, Claire Dempsey, Bruce Libby, Christopher S Melhus, Robin A Miller, Daniel J Scanderbeg, Samantha J Simiele Mar 2023

Aapm Medical Physics Practice Guideline 13a: Hdr Brachytherapy, Part A, Susan L Richardson, Ivan M Buzurovic, Gil'ad N Cohen, Wesley S Culberson, Claire Dempsey, Bruce Libby, Christopher S Melhus, Robin A Miller, Daniel J Scanderbeg, Samantha J Simiele

Faculty, Staff and Student Publications

The American Association of Physicists in Medicine (AAPM) is a nonprofit professional society whose primary purposes are to advance the science, education, and professional practice of medical physics. The AAPM has more than 8000 members and is the principal organization of medical physicists in the United States. The AAPM will periodically define new practice guidelines for medical physics practice to help advance the science of medical physics and to improve the quality of service to patients throughout the United States. Existing medical physics practice guidelines (MPPGs) will be reviewed for the purpose of revision or renewal, as appropriate, on their …


Risk Analysis Of The Unity 15 T Mr-Linac Adapt-To-Position Workflow, Jiayi Liang, Paola Godoy Scripes, Neelam Tyagi, Ergys Subashi, Theresa Wunner, Nicolas Cote, Ching-Yun Chan, Angela Ng, Victoria Brennan, Kaveh Zakeri, Cassandra Wildberger, James Mechalakos Mar 2023

Risk Analysis Of The Unity 15 T Mr-Linac Adapt-To-Position Workflow, Jiayi Liang, Paola Godoy Scripes, Neelam Tyagi, Ergys Subashi, Theresa Wunner, Nicolas Cote, Ching-Yun Chan, Angela Ng, Victoria Brennan, Kaveh Zakeri, Cassandra Wildberger, James Mechalakos

Faculty, Staff and Student Publications

BACKGROUND AND PURPOSE: Newer technologies allow for daily treatment adaptation, providing the ability to account for setup variations and organ motion but comes at the cost of increasing the treatment workflow complexity. One such technology is the adapt-to-position (ATP) workflow on the Unity MR-Linac. Prospective risk assessment of a new workflow allows clinics to catch errors before they occur, especially for processes that include novel and unfamiliar steps.

METHODS: As part of a quality management program, failure modes and effects analysis was performed on the ATP treatment workflow following the recommendations of AAPM's Task Group 100. A multidisciplinary team was …


Customizable Landmark-Based Field Aperture Design For Automated Whole-Brain Radiotherapy Treatment Planning, Yao Xiao, Carlos Cardenas, Dong Joo Rhee, Tucker Netherton, Lifei Zhang, Callistus Nguyen, Raphael Douglas, Raymond Mumme, Stephen Skett, Tina Patel, Chris Trauernicht, Caroline Chung, Hannah Simonds, Ajay Aggarwal, Laurence Court Mar 2023

Customizable Landmark-Based Field Aperture Design For Automated Whole-Brain Radiotherapy Treatment Planning, Yao Xiao, Carlos Cardenas, Dong Joo Rhee, Tucker Netherton, Lifei Zhang, Callistus Nguyen, Raphael Douglas, Raymond Mumme, Stephen Skett, Tina Patel, Chris Trauernicht, Caroline Chung, Hannah Simonds, Ajay Aggarwal, Laurence Court

Faculty, Staff and Student Publications

Purpose: To develop and evaluate an automated whole-brain radiotherapy (WBRT) treatment planning pipeline with a deep learning-based auto-contouring and customizable landmark-based field aperture design.

Methods: The pipeline consisted of the following steps: (1) Auto-contour normal structures on computed tomography scans and digitally reconstructed radiographs using deep learning techniques, (2) locate the landmark structures using the beam's-eye-view, (3) generate field apertures based on eight different landmark rules addressing different clinical purposes and physician preferences. Two parallel approaches for generating field apertures were developed for quality control. The performance of the generated field shapes and dose distributions were compared with the original …


Dual Beam-Current Transformer Design For Monitoring And Reporting Of Electron Ultra-High Dose Rate (Flash) Beam Parameters, Kevin Liu, Allison Palmiero, Nitish Chopra, Brett Velasquez, Ziyi Li, Sam Beddar, Emil Schüler Feb 2023

Dual Beam-Current Transformer Design For Monitoring And Reporting Of Electron Ultra-High Dose Rate (Flash) Beam Parameters, Kevin Liu, Allison Palmiero, Nitish Chopra, Brett Velasquez, Ziyi Li, Sam Beddar, Emil Schüler

Faculty, Staff and Student Publications

PURPOSE: To investigate the usefulness and effectiveness of a dual beam-current transformer (BCTs) design to monitor and record the beam dosimetry output and energy of pulsed electron FLASH (eFLASH) beams in real-time, and to inform on the usefulness of this design for future eFLASH beam control.

METHODS: Two BCTs are integrated into the head of a FLASH Mobetron system, one located after the primary scattering foil and the other downstream of the secondary scattering foil. The response of the BCTs was evaluated individually to monitor beam output as a function of dose, scattering conditions, and ability to capture physical beam …


Aapm Btsc Report 377: Physicist Brachytherapy Training In 2021-A Survey Of Therapeutic Medical Physics Residency Program Directors, Manik Aima, Samantha J Simiele, Susan L Richardson, Christopher S Melhus Feb 2023

Aapm Btsc Report 377: Physicist Brachytherapy Training In 2021-A Survey Of Therapeutic Medical Physics Residency Program Directors, Manik Aima, Samantha J Simiele, Susan L Richardson, Christopher S Melhus

Faculty, Staff and Student Publications

BACKGROUND: Brachytherapy (BT) was the first radiotherapeutic technique used to treat human disease and remains an essential modality in radiation oncology. A decline in the utilization of BT as a treatment modality has been observed and reported, which may impact training opportunities for medical physics residents. A survey of therapeutic medical physics residency program directors was performed as part of an assessment of the current state of BT training during residency.

METHODS: In March 2021, a survey consisting of 23 questions was designed by a working unit of the Brachytherapy Subcommittee of the American Association of Physicists in Medicine (AAPM) …


4d Lung Mri With High-Isotropic-Resolution Using Half-Spoke (Ute) And Full-Spoke 3d Radial Acquisition And Temporal Compressed Sensing Reconstruction, Can Wu, Guruprasad Krishnamoorthy, Victoria Yu, Ergys Subashi, Andreas Rimner, Ricardo Otazo Jan 2023

4d Lung Mri With High-Isotropic-Resolution Using Half-Spoke (Ute) And Full-Spoke 3d Radial Acquisition And Temporal Compressed Sensing Reconstruction, Can Wu, Guruprasad Krishnamoorthy, Victoria Yu, Ergys Subashi, Andreas Rimner, Ricardo Otazo

Faculty, Staff and Student Publications

Objective:

To develop a respiratory motion-resolved 4D MRI technique with high-isotropic-resolution (1.1 mm) using 3D radial sampling, camera-based respiratory motion sensing, and temporal compressed sensing reconstruction for lung cancer imaging.

Approach:

Free-breathing half- and full-spoke 3D golden-angle radial acquisitions were performed on eight healthy volunteers and eight patients with lung tumors of varying size. A back-and-forth k-space ordering between consecutive interleaves of the 3D radial acquisition was performed to minimize eddy current-related artifacts. Data were sorted into respiratory motion states using camera-based motion navigation and 4D images were reconstructed using temporal compressed sensing to reduce scan time. Normalized sharpness indices …


Development Of A Qa Plan For A 3.0t Cannon Galan Mr-Sim, Nathaniel D. Teague Jan 2023

Development Of A Qa Plan For A 3.0t Cannon Galan Mr-Sim, Nathaniel D. Teague

Theses and Dissertations

Purpose: To develop and incorporate a QA (quality assurance) program for a Canon Galan 3 tesla MR Simulator for applications in radiation therapy.

Methods and materials: The QA program was centered around tests performed with three separate levels of frequency. The daily QA procedure consisted of scanning a vendor provided daily QA cube phantom that measures basic performance parameters. Additionally, a series of basic safety check were performed. The monthly QA procedure consisted of several tests, including scanning the ACR MRI large accreditation phantom and manually performing its corresponding image quality tests. Scanning the MagPhan RT for its detailed geometric …


Optimization Of Mesh Generation For Geometric Accuracy, Robustness, And Efficiency Of Biomechanical-Model-Based Deformable Image Registration, Yulun He, Brian M Anderson, Guillaume Cazoulat, Bastien Rigaud, Lusmeralis Almodovar-Abreu, Julianne Pollard-Larkin, Peter Balter, Zhongxing Liao, Radhe Mohan, Bruno Odisio, Stina Svensson, Kristy K Brock Jan 2023

Optimization Of Mesh Generation For Geometric Accuracy, Robustness, And Efficiency Of Biomechanical-Model-Based Deformable Image Registration, Yulun He, Brian M Anderson, Guillaume Cazoulat, Bastien Rigaud, Lusmeralis Almodovar-Abreu, Julianne Pollard-Larkin, Peter Balter, Zhongxing Liao, Radhe Mohan, Bruno Odisio, Stina Svensson, Kristy K Brock

Faculty, Staff and Student Publications

BACKGROUND: Successful generation of biomechanical-model-based deformable image registration (BM-DIR) relies on user-defined parameters that dictate surface mesh quality. The trial-and-error process to determine the optimal parameters can be labor-intensive and hinder DIR efficiency and clinical workflow.

PURPOSE: To identify optimal parameters in surface mesh generation as boundary conditions for a BM-DIR in longitudinal liver and lung CT images to facilitate streamlined image registration processes.

METHODS: Contrast-enhanced CT images of 29 colorectal liver cancer patients and end-exhale four-dimensional CT images of 26 locally advanced non-small cell lung cancer patients were collected. Different combinations of parameters that determine the triangle mesh quality …


View-Sharing For 4d Magnetic Resonance Imaging With Randomized Projection-Encoding Enables Improvements Of Respiratory Motion Imaging For Treatment Planning In Abdominothoracic Radiotherapy, Ergys Subashi, Li Feng, Yilin Liu, Scott Robertson, Paul Segars, Bastiaan Driehuys, Christopher R Kelsey, Fang-Fang Yin, Ricardo Otazo, Jing Cai Jan 2023

View-Sharing For 4d Magnetic Resonance Imaging With Randomized Projection-Encoding Enables Improvements Of Respiratory Motion Imaging For Treatment Planning In Abdominothoracic Radiotherapy, Ergys Subashi, Li Feng, Yilin Liu, Scott Robertson, Paul Segars, Bastiaan Driehuys, Christopher R Kelsey, Fang-Fang Yin, Ricardo Otazo, Jing Cai

Faculty, Staff and Student Publications

BACKGROUND AND PURPOSE: The accuracy and precision of radiation therapy are dependent on the characterization of organ-at-risk and target motion. This work aims to demonstrate a 4D magnetic resonance imaging (MRI) method for improving spatial and temporal resolution in respiratory motion imaging for treatment planning in abdominothoracic radiotherapy.

MATERIALS AND METHODS: The spatial and temporal resolution of phase-resolved respiratory imaging is improved by considering a novel sampling function based on quasi-random projection-encoding and peripheral k-space view-sharing. The respiratory signal is determined directly from k-space, obviating the need for an external surrogate marker. The average breathing curve is used to optimize …


Factors Modulating 99mtc-Maa Planar Lung Dosimetry For 90y Radioembolization, Benjamin P Lopez, Armeen Mahvash, James P Long, Marnix G E H Lam, S Cheenu Kappadath Dec 2022

Factors Modulating 99mtc-Maa Planar Lung Dosimetry For 90y Radioembolization, Benjamin P Lopez, Armeen Mahvash, James P Long, Marnix G E H Lam, S Cheenu Kappadath

Faculty, Staff and Student Publications

Purpose: To investigate the accuracy and biases of predicted lung shunt fraction (LSF) and lung dose (LD) calculations via 99m Tc-macro-aggregated albumin (99m Tc-MAA) planar imaging for treatment planning of 90 Y-microsphere radioembolization.

Methods and materials: LSFs in 52 planning and LDs in 44 treatment procedures were retrospectively calculated, in consecutive radioembolization patients over a 2 year interval, using 99m Tc-MAA planar and SPECT/CT imaging. For each procedure, multiple planar LSFs and LDs were calculated using different: (1) contours, (2) views, (3) liver 99m Tc-MAA shine-through compensations, and (4) lung mass estimations. The accuracy of each planar-based LSF and LD …


Infrastructure Development For Personalized Risk Prediction To Reduce Cardiovascular Disease In Childhood Cancer Survivors, Suman Shrestha Dec 2022

Infrastructure Development For Personalized Risk Prediction To Reduce Cardiovascular Disease In Childhood Cancer Survivors, Suman Shrestha

Dissertations and Theses (Open Access)

Although childhood cancer survivors have lengthy life expectancies, they run the risk of experiencing long-term health issues as a result of their treatment. The most frequent non-cancerous cause of morbidity and mortality for these survivors is cardiac disease. Radiation therapy (RT) has been linked in numerous cohort studies to a higher chance of developing a late cardiac disease in these survivors, and this risk rises with higher mean heart doses and increased RT exposure to larger cardiac volumes. Since, the heart is a heterogeneous organ made up of several distinct substructures, RT dose received by the entire heart does not …


Comparison Of Setup Accuracy And Efficiency Between The Klarity System And Bodyfix System For Spine Stereotactic Body Radiation Therapy, Enzhuo Quan, Shane P Krafft, Tina M Briere, Marissa J Vaccarelli, Amol J Ghia, Andrew J Bishop, Debra N Yeboa, Todd A Swanson, Eun Young Han Nov 2022

Comparison Of Setup Accuracy And Efficiency Between The Klarity System And Bodyfix System For Spine Stereotactic Body Radiation Therapy, Enzhuo Quan, Shane P Krafft, Tina M Briere, Marissa J Vaccarelli, Amol J Ghia, Andrew J Bishop, Debra N Yeboa, Todd A Swanson, Eun Young Han

Faculty, Staff and Student Publications

BACKGROUND: Spine stereotactic body radiation therapy (SBRT) uses highly conformal dose distributions and sharp dose gradients to cover targets in proximity to the spinal cord or cauda equina, which requires precise patient positioning and immobilization to deliver safe treatments.

AIMS: Given some limitations with the BodyFIX system in our practice, we sought to evaluate the accuracy and efficiency of the Klarity SBRT patient immobilization system in comparison to the BodyFIX system.

METHODS: Twenty-three patients with 26 metastatic spinal lesions (78 fractions) were enrolled in this prospective observational study with one of two systems - BodyFIX (n = 11) or Klarity …


Anatomical Validation Of Automatic Respiratory Motion Correction For Coronary 18f-Sodium Fluoride Positron Emission Tomography By Expert Measurements From Four-Dimensional Computed Tomography, Martin Lyngby Lassen, Evangelos Tzolos, Tinsu Pan, Jacek Kwiecinski, Sebastien Cadet, Damini Dey, Daniel Berman, Piotr Slomka Nov 2022

Anatomical Validation Of Automatic Respiratory Motion Correction For Coronary 18f-Sodium Fluoride Positron Emission Tomography By Expert Measurements From Four-Dimensional Computed Tomography, Martin Lyngby Lassen, Evangelos Tzolos, Tinsu Pan, Jacek Kwiecinski, Sebastien Cadet, Damini Dey, Daniel Berman, Piotr Slomka

Faculty, Staff and Student Publications

BACKGROUND: Respiratory motion correction is of importance in studies of coronary plaques employing

PURPOSE: To investigate the accuracy of the motion correction employed in a software (FusionQuant) used for evaluation of

METHODS: This study included 23 patients who undertook thoracic PET scans for the assessment of coronary plaques using

RESULTS: In total, 19 coronary plaques were identified in 16 patients. No statistical differences were observed for the maximum respiratory motion observed in x, y, and the 3D motion fields (magnitude and direction) between the CT and PET (X direction: 4D CT = 2.5 ± 1.5 mm, PET = 2.4 ± …


Dosimetric Analysis Of Mr-Linac Treatment Plans For Salvage Spine Sbrt Re-Irradiation, Eun Young Han, Debra N Yeboa, Tina M Briere, Jinzhong Yang, He Wang Oct 2022

Dosimetric Analysis Of Mr-Linac Treatment Plans For Salvage Spine Sbrt Re-Irradiation, Eun Young Han, Debra N Yeboa, Tina M Briere, Jinzhong Yang, He Wang

Faculty, Staff and Student Publications

PURPOSE: We investigated the feasibility of thoracic spine stereotactic body radiotherapy (SBRT) using the Elekta Unity magnetic resonance-guided linear accelerator (MRL) in patients who received prior radiotherapy. We hypothesized that Monaco treatment plans can improve the gross tumor volume minimum dose (GTVmin) with spinal cord preservation and maintain consistent plan quality during daily adaptation.

METHODS: Pinnacle clinical plans for 10 patients who underwent thoracic spine SBRT (after prior radiotherapy) were regenerated in the Monaco treatment planning system for the Elekta Unity MRL using 9 and 13 intensity-modulated radiotherapy (IMRT) beams. Monaco adapt-to-position (ATP) and adapt-to-shape (ATS) workflow plans were generated …


Aapm Report 373: The Content, Structure, And Value Of The Professional Doctorate In Medical Physics (Dmp), Jay W Burmeister, Charles W Coffey, John D Hazle, Neil Kirby, Yu Kuang, Michael A Lamba, Brian Loughery, Niko Papanikolaou Oct 2022

Aapm Report 373: The Content, Structure, And Value Of The Professional Doctorate In Medical Physics (Dmp), Jay W Burmeister, Charles W Coffey, John D Hazle, Neil Kirby, Yu Kuang, Michael A Lamba, Brian Loughery, Niko Papanikolaou

Faculty, Staff and Student Publications

The Professional Doctorate in Medical Physics (DMP) was originally conceived as a solution to the shortage of medical physics residency training positions. While this shortage has now been largely satisfied through conventional residency training positions, the DMP has expanded to multiple institutions and grown into an educational pathway that provides specialized clinical training and extends well beyond the creation of additional training spots. As such, it is important to reevaluate the purpose and the value of the DMP. Additionally, it is important to outline the defining characteristics of the DMP to assure that all existing and future programs provide this …


An Empirical Model Of Proton Rbe Based On The Linear Correlation Between X-Ray And Proton Radiosensitivity, David B Flint, Chase E Ruff, Scott J Bright, Pablo Yepes, Qianxia Wang, Mandira Manandhar, Mariam Ben Kacem, Broderick X Turner, David K J Martinus, Simona F Shaitelman, Gabriel O Sawakuchi Sep 2022

An Empirical Model Of Proton Rbe Based On The Linear Correlation Between X-Ray And Proton Radiosensitivity, David B Flint, Chase E Ruff, Scott J Bright, Pablo Yepes, Qianxia Wang, Mandira Manandhar, Mariam Ben Kacem, Broderick X Turner, David K J Martinus, Simona F Shaitelman, Gabriel O Sawakuchi

Faculty, Staff and Student Publications

Background: Proton relative biological effectiveness (RBE) is known to depend on physical factors of the proton beam, such as its linear energy transfer (LET), as well as on cell-line specific biological factors, such as their ability to repair DNA damage. However, in a clinical setting, proton RBE is still considered to have a fixed value of 1.1 despite the existence of several empirical models that can predict proton RBE based on how a cell's survival curve (linear-quadratic model [LQM]) parameters α and β vary with the LET of the proton beam. Part of the hesitation to incorporate variable RBE models …


Clinical Acceptability Of Fully Automated External Beam Radiotherapy For Cervical Cancer With Three Different Beam Delivery Techniques, Dong Joo Rhee, Anuja Jhingran, Kai Huang, Tucker J Netherton, Nazia Fakie, Ingrid White, Alicia Sherriff, Carlos E Cardenas, Lifei Zhang, Surendra Prajapati, Stephen F Kry, Beth M Beadle, William Shaw, Frederika O'Reilly, Jeannette Parkes, Hester Burger, Chris Trauernicht, Hannah Simonds, Laurence E Court Sep 2022

Clinical Acceptability Of Fully Automated External Beam Radiotherapy For Cervical Cancer With Three Different Beam Delivery Techniques, Dong Joo Rhee, Anuja Jhingran, Kai Huang, Tucker J Netherton, Nazia Fakie, Ingrid White, Alicia Sherriff, Carlos E Cardenas, Lifei Zhang, Surendra Prajapati, Stephen F Kry, Beth M Beadle, William Shaw, Frederika O'Reilly, Jeannette Parkes, Hester Burger, Chris Trauernicht, Hannah Simonds, Laurence E Court

Faculty, Staff and Student Publications

Purpose: To fully automate CT-based cervical cancer radiotherapy by automating contouring and planning for three different treatment techniques.

Methods: We automated three different radiotherapy planning techniques for locally advanced cervical cancer: 2D 4-field-box (4-field-box), 3D conformal radiotherapy (3D-CRT), and volumetric modulated arc therapy (VMAT). These auto-planning algorithms were combined with a previously developed auto-contouring system. To improve the quality of the 4-field-box and 3D-CRT plans, we used an in-house, field-in-field (FIF) automation program. Thirty-five plans were generated for each technique on CT scans from multiple institutions and evaluated by five experienced radiation oncologists from three different countries. Every plan was …


Development And Validation Of A Checklist For Use With Automatically Generated Radiotherapy Plans, Kelly A Nealon, Laurence E Court, Raphael J Douglas, Lifei Zhang, Eun Young Han Sep 2022

Development And Validation Of A Checklist For Use With Automatically Generated Radiotherapy Plans, Kelly A Nealon, Laurence E Court, Raphael J Douglas, Lifei Zhang, Eun Young Han

Faculty, Staff and Student Publications

Purpose: To develop a checklist that improves the rate of error detection during the plan review of automatically generated radiotherapy plans.

Methods: A custom checklist was developed using guidance from American Association of Physicists in Medicine task groups 275 and 315 and the results of a failure modes and effects analysis of the Radiation Planning Assistant (RPA), an automated contouring and treatment planning tool. The preliminary checklist contained 90 review items for each automatically generated plan. In the first study, eight physicists were recruited from our institution who were familiar with the RPA. Each physicist reviewed 10 artificial intelligence-generated resident …