Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Physical Sciences and Mathematics (6)
- Physics (5)
- Other Physics (4)
- Medical Specialties (2)
- Anthropology (1)
-
- Biological and Physical Anthropology (1)
- Ecology and Evolutionary Biology (1)
- Interprofessional Education (1)
- Life Sciences (1)
- Medical Education (1)
- Oncology (1)
- Other Anthropology (1)
- Other Ecology and Evolutionary Biology (1)
- Patient Safety (1)
- Radiation Medicine (1)
- Radiology (1)
- Social Statistics (1)
- Social and Behavioral Sciences (1)
- Keyword
-
- Prostate cancer (2)
- Radiation therapy (2)
- Analytical Model (1)
- Beamline hutches (1)
- Biomechanic evolution (1)
-
- Blood Flow (1)
- Bolus (1)
- Conformal (1)
- Correlation (1)
- Cranium (1)
- Deep learning (1)
- Dose Calculation (1)
- Dose prediction (1)
- Electron (1)
- Electrons (1)
- Energy (1)
- Feline (1)
- Gamma passing rate (GPR) (1)
- High-resolution imaging (1)
- Human obstetrics (1)
- Hyperthyroidism (1)
- Intensity (1)
- Iodine-131 (1)
- Knowledge-based planning (1)
- Linac (1)
- Lung Imaging (1)
- Machine learning (1)
- MapCHECK3 diode array (1)
- Mary Bird Perkins Cancer Center (MBPCC) (1)
- Medical Physics (1)
Articles 1 - 15 of 15
Full-Text Articles in Health and Medical Physics
Theory, Experiments, And Image Recovery Algorithms For X-Ray Interferometry, Hunter C. Meyer
Theory, Experiments, And Image Recovery Algorithms For X-Ray Interferometry, Hunter C. Meyer
LSU Doctoral Dissertations
Purpose: X-ray grating interferometry is a form of X-ray phase contrast imaging capable of simultaneously measuring attenuation, differential-phase, and dark-field images arising from X-ray absorption, refraction, and small-angle scattering, respectively. These additional contrast mechanisms have potential clinical and industrial applications, particularly for lung tissue characterization and disease identification. As grating interferometers approach clinical viability, key challenges include reducing X-ray dose, mitigating mechanical instability, and correcting spectral artifacts resulting from beam hardening.
Methods: The modulated phase grating interferometer (MPGI) is a potential solution for reducing X-ray dose by eliminating the analyzer grating used in alternative interferometer designs, including the Talbot-Lau interferometer …
Post-Modeling Adjustments And Delivered Dose Verification Of The 6fff Beam Model Commissioned For The Monaco Treatment Planning System, Grant C. Debevec
Post-Modeling Adjustments And Delivered Dose Verification Of The 6fff Beam Model Commissioned For The Monaco Treatment Planning System, Grant C. Debevec
LSU Master's Theses
External beam radiation therapy has been shown to be an effective treatment method for tumors and abnormalities of the spine and vertebral region. Treating the spine using a stereotactic body radiation therapy (SBRT) technique can reduce toxicity to the spinal cord. The 6 MV flattening filter free (6FFF) beam model is currently used to plan and calculate dose for SBRT treatment plans, and the treatment plans are delivered using a linear accelerator (LINAC).
The commissioned beam model represents an invariant component of a LINAC. For volumetric modulated arc therapy (VMAT) treatment plans, the multileaf collimator (MLC) positions are changing throughout …
The Theory Of X-Ray And Neutron Interferometry Using A Modulated Phase Grating, Hunter C. Meyer
The Theory Of X-Ray And Neutron Interferometry Using A Modulated Phase Grating, Hunter C. Meyer
LSU Master's Theses
Grating interferometry exploits wave interference to simultaneously image multiple physical properties of an object and can be performed using X-rays or neutrons. The modulated phase grating interferometer (MPGI) is a recently developed interferometry system that allows for the simultaneous acquisition of attenuation, differential-phase contrast, and dark-field images, which highlight X-ray or neutron absorption, refraction, and small angle scatter, respectively. This interferometry system uses a single grating, with a relatively high period envelope function, to produce interference fringes that can be directly resolved by standard high resolution detectors. The grating is sampled at a relatively low pitch, to meet coherence requirements …
Patient Specific Normalized Glandular Dose Range Estimate For Mammography, Lacey Medlock
Patient Specific Normalized Glandular Dose Range Estimate For Mammography, Lacey Medlock
LSU Master's Theses
Breast cancer is the most common type of cancer among women in the United States. It is also the second leading cause of death by cancer among women in the United States. Early detection is key to preventing fatalities. There are over 39 million mammography screening procedures performed yearly [3]. We know that exposure to radiation, including in routine mammography, may induce secondary cancers [4]. Thus, it is important to be able to accurately estimate the dose delivered to a patient during breast cancer screening. The dose delivered to a patient is regulated in the US and in many other …
Dose Calculation And Prediction Methods For Gamma Knife Stereotactic Radiosurgery, Payton Hayes Stone
Dose Calculation And Prediction Methods For Gamma Knife Stereotactic Radiosurgery, Payton Hayes Stone
LSU Doctoral Dissertations
Implementation of automation routines leveraging deep learning (DL) methods has been a growing topic of interest. The focus of this work is on the Gamma Knife (GK) workflow, specifically the approximation of dose distributions from GK plan parameters and the prediction of dose distributions using DL. These works contribute towards the larger goal of treatment plan prediction and are seen as intermediate steps towards that end. The approximation of dose distributions was motivated by the closed nature of the GK system, which causes complications with the evaluation of the predictions made by the DL models. The approximation utilizes a superposition …
Modeling Of Island Block Scatter For Intensity Modulated Bolus Electron Conformal Therapy, Joseph G. Scotto
Modeling Of Island Block Scatter For Intensity Modulated Bolus Electron Conformal Therapy, Joseph G. Scotto
LSU Master's Theses
Purpose: Bolus electron conformal therapy (BECT) benefits treatment of the post-mastectomy chest wall, head and neck, paraspinal muscles, and extremities. Patient dose heterogeneities caused by bolus can be reduced through intensity modulation (IM) across the incident electron beam. This requires passive radiotherapy intensity modulation for electrons (PRIME) devices, which utilize tungsten pins (island blocks) imbedded in machinable foam. IM-BECT treatment planning requires accurate dose calculation using the pencil beam redefinition dose algorithm (PBRA). Currently, the PBRA models island blocks as perfect collimators. This work explores models to account for electrons scattering into and out of the sides of island blocks. …
Reconsidering The Obstetrical Dilemma: Correlations Between Head And Pelvic Size, Kelsey Catrice Fox
Reconsidering The Obstetrical Dilemma: Correlations Between Head And Pelvic Size, Kelsey Catrice Fox
LSU Master's Theses
The Obstetrical Dilemma (OD) theory has become canon in biological anthropology. The OD posits that i] dystocia results from bipedal mothers and encephalized infants, ii] contrasting selection for bipedality and obstetrics hinders locomotive efficiency, and iii] the contradicting requirement of the fetus being small enough to pass through the birth canal yet being cognitively advanced enough to cling to its mother after birth. Females, theoretically, exhibit deficient gait efficiency for the sake of successful childbirth. An obstetric advantage theory has been posited where taller individuals with a larger head size have larger pelves. If the distance between the acetabulae increases …
Towards Optimizing Quality Assurance Outcomes Of Knowledge-Based Radiation Therapy Treatment Plans Using Machine Learning, Phillip Douglas Hardenbergh Wall
Towards Optimizing Quality Assurance Outcomes Of Knowledge-Based Radiation Therapy Treatment Plans Using Machine Learning, Phillip Douglas Hardenbergh Wall
LSU Doctoral Dissertations
Knowledge-based planning (KBP) techniques have been shown to provide improvements in plan quality, consistency, and efficiency for advanced radiation therapies such as volumetric modulated arc therapy (VMAT). While the potential clinical benefits of KBP methods are generally well known, comparatively less is understood regarding the impact of using these systems on resulting plan complexity and pre-treatment quality assurance (QA) measurements, especially for in-house KBP systems. Therefore, the overarching purpose of this work was to assess QA implications with using an in-house KBP system and explore data-driven methods for mitigating increased plan complexity and QA error rates without compromising dosimetric plan …
Evaluating Feline Release Criteria Following Iodine-131 Therapy For Hyperthyroidism, Anthony Davila
Evaluating Feline Release Criteria Following Iodine-131 Therapy For Hyperthyroidism, Anthony Davila
LSU Master's Theses
Hyperthyroidism is a very common endocrine disorder in both humans and cats. Radioactive iodine ablation therapy is considered the gold standard; however, the patient becomes a radiation source and poses a potential radiological risk to others. The regulations governing when the patient can be released differ between human medicine and veterinary medicine. A human patient can receive up to 33 mCi of I-131 and be discharged the same day; yet a feline patient can receive a dose as low as 2 mCi and require multiple days of hospitalization. This discrepancy has not been satisfactorily addressed; and overly restrictive release criteria …
Stray Radiation Dose From X-Ray And Proton Beam Radiation Therapies, Christopher William Schneider
Stray Radiation Dose From X-Ray And Proton Beam Radiation Therapies, Christopher William Schneider
LSU Doctoral Dissertations
The growing population of cancer survivors at risk of radiation induced side-effects is a public health concern. These side-effects include serious conditions such as second cancers, the majority of which occur outside of the primary treatment volume. Radiotherapy treatment planning systems systematically underestimate the dose to tissues out-of-field. Attempts to predict and reduce the risks of radiogenic side effects require accurate and personalized knowledge of the out-of-field radiation dose to patients. The long-term goal of this research is to provide clinical and research tools necessary to reduce the risk of radiotherapy side effects and improve the health outcomes of radiotherapy …
Computational Feasibility Of Simulating Whole-Organ Vascular Networks And Their Response To Injury, William Patrick Donahue
Computational Feasibility Of Simulating Whole-Organ Vascular Networks And Their Response To Injury, William Patrick Donahue
LSU Doctoral Dissertations
Healthy vasculature is critical to sustaining the function of normal tissues in the human body. Radiation therapy for cancer causes injury of the vasculature of non-cancerous tissues. These changes have been associated with potentially deadly conditions such as necrosis of the brain tissue. There are currently no computational methods to study the effects of radiation vascular injury in whole-organ vasculatures because of the large number of vessels involved. The goal of this work was to test the feasibility of simulating radiation damage to whole-brain vascular networks and calculate the resulting change in blood flow. To accomplish this, we developed algorithms …
Determination Of Scatter Fractions, Albedos, And Tenth Value Layers For Shielding Of Synchrotron Beamline Hutches, Bethany Lynn Broekhoven
Determination Of Scatter Fractions, Albedos, And Tenth Value Layers For Shielding Of Synchrotron Beamline Hutches, Bethany Lynn Broekhoven
LSU Master's Theses
Synchrotron facilities require substantial amounts of shielding to protect facility staff and researchers. To meet mandatory exposure limits, the traditional combination of time, distance, and shielding of the radiation source are utilized. Because of continuous 24-7 operation of most synchrotrons, time is the least useful tool. The experimental stations for synchrotron x-ray beamlines, called hutches, enforce a minimum distance from the source, but shielding provided by hutch walls is still the principal tool for a synchrotron facility. Currently there is no single resource for synchrotron beamline hutch shielding design in the literature; most hutch shielding is designed through either over-simplified …
Framework For Algorithmically Optimizing Longitudinal Health Outcomes: Examples In Cancer Radiotherapy And Occupational Radiation Protection, Lydia Joyce Wilson
Framework For Algorithmically Optimizing Longitudinal Health Outcomes: Examples In Cancer Radiotherapy And Occupational Radiation Protection, Lydia Joyce Wilson
LSU Doctoral Dissertations
Background: Advancements in the treatment of non-infectious disease have enabled survival rates to steadily increase in recent decades (e.g., diabetes, heart disease, and cancer). Epidemiological studies have revealed that the treatments for these diseases can have life-threatening and/or life–altering effects. Thus, realizing the full beneficial potential of advanced treatments necessitates new tools to algorithmically consider all major components of the health outcome, including benefit and detriment. The goal of this dissertation was to develop a framework for improving projected health outcomes following planned radiation exposures in consideration of all beneficial and detrimental, early and late, and fatal and non-fatal …
Endorectal Digital Prostate Tomosynthesis, Joseph Robert Steiner
Endorectal Digital Prostate Tomosynthesis, Joseph Robert Steiner
LSU Doctoral Dissertations
Several areas of prostate cancer (PCa) management, such as imaging permanent brachytherapy implants or small, aggressive lesions, benefit from high image resolution. Current PCa imaging methods can have inadequate resolution for imaging these areas. Endorectal digital prostate tomosynthesis (endoDPT), an imaging method that combines an external x-ray source and an endorectal x-ray sensor, can produce three-dimensional images of the prostate region that have high image resolution compared to typical methods. This high resolution may improve PCa management and increase positive outcomes in affected men.
This dissertation presents the initial development of endoDPT, including system design, image quality assessment, and examples …
Development And Applications Of A Real-Time Magnetic Electron Energy Spectrometer For Use With Medical Linear Accelerators, Paul Ethan Maggi
Development And Applications Of A Real-Time Magnetic Electron Energy Spectrometer For Use With Medical Linear Accelerators, Paul Ethan Maggi
LSU Doctoral Dissertations
Purpose – This work presents a design for a real-time electron energy spectrometer, and provides data analysis methods and characterization of the real-time system. This system is intended for use with medical linear accelerators (linacs). The goal is 1 Hz acquisition of the energy range 4-25 MeV, reconstructed in 0.1 MeV increments.
Methods – Our spectrometer uses a nominal 0.54 T permanent magnet block as the dispersive element and scintillating fibers coupled to a CCD camera as the position sensitive detector. A broad electron beam produced by a linac is collimated by a 6.35 mm dimeter aperture at the entrance …