Open Access. Powered by Scholars. Published by Universities.®
- Discipline
- Keyword
-
- Beamline hutches (1)
- Biomechanic evolution (1)
- Bolus (1)
- Conformal (1)
- Correlation (1)
-
- Cranium (1)
- Electron (1)
- Feline (1)
- Gamma passing rate (GPR) (1)
- Human obstetrics (1)
- Hyperthyroidism (1)
- Intensity (1)
- Iodine-131 (1)
- MapCHECK3 diode array (1)
- Mary Bird Perkins Cancer Center (MBPCC) (1)
- Modulation (1)
- Obstetric Dilemma (1)
- Patient specific quality assurance (PSQA) (1)
- Pelvis (1)
- Radiation protection (1)
- Radiation therapy (1)
- Shielding (1)
- Stereotactic body radiation therapy (SBRT) (1)
- Synchrotron (1)
- Therapy (1)
- X-ray Neutron Interferometry Diffraction Grating Optics (1)
Articles 1 - 7 of 7
Full-Text Articles in Health and Medical Physics
Post-Modeling Adjustments And Delivered Dose Verification Of The 6fff Beam Model Commissioned For The Monaco Treatment Planning System, Grant C. Debevec
Post-Modeling Adjustments And Delivered Dose Verification Of The 6fff Beam Model Commissioned For The Monaco Treatment Planning System, Grant C. Debevec
LSU Master's Theses
External beam radiation therapy has been shown to be an effective treatment method for tumors and abnormalities of the spine and vertebral region. Treating the spine using a stereotactic body radiation therapy (SBRT) technique can reduce toxicity to the spinal cord. The 6 MV flattening filter free (6FFF) beam model is currently used to plan and calculate dose for SBRT treatment plans, and the treatment plans are delivered using a linear accelerator (LINAC).
The commissioned beam model represents an invariant component of a LINAC. For volumetric modulated arc therapy (VMAT) treatment plans, the multileaf collimator (MLC) positions are changing throughout …
The Theory Of X-Ray And Neutron Interferometry Using A Modulated Phase Grating, Hunter C. Meyer
The Theory Of X-Ray And Neutron Interferometry Using A Modulated Phase Grating, Hunter C. Meyer
LSU Master's Theses
Grating interferometry exploits wave interference to simultaneously image multiple physical properties of an object and can be performed using X-rays or neutrons. The modulated phase grating interferometer (MPGI) is a recently developed interferometry system that allows for the simultaneous acquisition of attenuation, differential-phase contrast, and dark-field images, which highlight X-ray or neutron absorption, refraction, and small angle scatter, respectively. This interferometry system uses a single grating, with a relatively high period envelope function, to produce interference fringes that can be directly resolved by standard high resolution detectors. The grating is sampled at a relatively low pitch, to meet coherence requirements …
Patient Specific Normalized Glandular Dose Range Estimate For Mammography, Lacey Medlock
Patient Specific Normalized Glandular Dose Range Estimate For Mammography, Lacey Medlock
LSU Master's Theses
Breast cancer is the most common type of cancer among women in the United States. It is also the second leading cause of death by cancer among women in the United States. Early detection is key to preventing fatalities. There are over 39 million mammography screening procedures performed yearly [3]. We know that exposure to radiation, including in routine mammography, may induce secondary cancers [4]. Thus, it is important to be able to accurately estimate the dose delivered to a patient during breast cancer screening. The dose delivered to a patient is regulated in the US and in many other …
Modeling Of Island Block Scatter For Intensity Modulated Bolus Electron Conformal Therapy, Joseph G. Scotto
Modeling Of Island Block Scatter For Intensity Modulated Bolus Electron Conformal Therapy, Joseph G. Scotto
LSU Master's Theses
Purpose: Bolus electron conformal therapy (BECT) benefits treatment of the post-mastectomy chest wall, head and neck, paraspinal muscles, and extremities. Patient dose heterogeneities caused by bolus can be reduced through intensity modulation (IM) across the incident electron beam. This requires passive radiotherapy intensity modulation for electrons (PRIME) devices, which utilize tungsten pins (island blocks) imbedded in machinable foam. IM-BECT treatment planning requires accurate dose calculation using the pencil beam redefinition dose algorithm (PBRA). Currently, the PBRA models island blocks as perfect collimators. This work explores models to account for electrons scattering into and out of the sides of island blocks. …
Reconsidering The Obstetrical Dilemma: Correlations Between Head And Pelvic Size, Kelsey Catrice Fox
Reconsidering The Obstetrical Dilemma: Correlations Between Head And Pelvic Size, Kelsey Catrice Fox
LSU Master's Theses
The Obstetrical Dilemma (OD) theory has become canon in biological anthropology. The OD posits that i] dystocia results from bipedal mothers and encephalized infants, ii] contrasting selection for bipedality and obstetrics hinders locomotive efficiency, and iii] the contradicting requirement of the fetus being small enough to pass through the birth canal yet being cognitively advanced enough to cling to its mother after birth. Females, theoretically, exhibit deficient gait efficiency for the sake of successful childbirth. An obstetric advantage theory has been posited where taller individuals with a larger head size have larger pelves. If the distance between the acetabulae increases …
Evaluating Feline Release Criteria Following Iodine-131 Therapy For Hyperthyroidism, Anthony Davila
Evaluating Feline Release Criteria Following Iodine-131 Therapy For Hyperthyroidism, Anthony Davila
LSU Master's Theses
Hyperthyroidism is a very common endocrine disorder in both humans and cats. Radioactive iodine ablation therapy is considered the gold standard; however, the patient becomes a radiation source and poses a potential radiological risk to others. The regulations governing when the patient can be released differ between human medicine and veterinary medicine. A human patient can receive up to 33 mCi of I-131 and be discharged the same day; yet a feline patient can receive a dose as low as 2 mCi and require multiple days of hospitalization. This discrepancy has not been satisfactorily addressed; and overly restrictive release criteria …
Determination Of Scatter Fractions, Albedos, And Tenth Value Layers For Shielding Of Synchrotron Beamline Hutches, Bethany Lynn Broekhoven
Determination Of Scatter Fractions, Albedos, And Tenth Value Layers For Shielding Of Synchrotron Beamline Hutches, Bethany Lynn Broekhoven
LSU Master's Theses
Synchrotron facilities require substantial amounts of shielding to protect facility staff and researchers. To meet mandatory exposure limits, the traditional combination of time, distance, and shielding of the radiation source are utilized. Because of continuous 24-7 operation of most synchrotrons, time is the least useful tool. The experimental stations for synchrotron x-ray beamlines, called hutches, enforce a minimum distance from the source, but shielding provided by hutch walls is still the principal tool for a synchrotron facility. Currently there is no single resource for synchrotron beamline hutch shielding design in the literature; most hutch shielding is designed through either over-simplified …