Open Access. Powered by Scholars. Published by Universities.®

Health and Medical Physics Commons™

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 3 of 3

Full-Text Articles in Health and Medical Physics

Investigating The Uncertainties In Ct Non-Small Cell Lung Cancer Radiomics, Gary Ge Jan 2022

Investigating The Uncertainties In Ct Non-Small Cell Lung Cancer Radiomics, Gary Ge

Theses and Dissertations--Radiation Medicine

Radiomics is a technique that extracts quantitative features, termed radiomic features, from medical images using data-characterization algorithms. These radiomic features can be used to identify tissue characteristics and radiologic phenotyping that are not observable by clinicians in a non-invasive, low-cost manner, potentially generating image biomarkers for clinical decision. To date, there are still many uncertainties involved in radiomics which limit its clinical implementation. Herein, we propose to explore the impact of each component in the radiomics pipeline on predicting clinical outcomes. In Chapter II, we conduct a thorough review of CT lung cancer radiomics studies to examine the typical feature …


Potential Reduction Of Lung Dose Via Vmat With Jaw Tracking In The Treatment Of Single-Isocenter/Two-Lesion Lung Sbrt, Damodar Pokhrel, Lana Sanford, Matthew Halfman, Janelle A. Molloy May 2019

Potential Reduction Of Lung Dose Via Vmat With Jaw Tracking In The Treatment Of Single-Isocenter/Two-Lesion Lung Sbrt, Damodar Pokhrel, Lana Sanford, Matthew Halfman, Janelle A. Molloy

Radiation Medicine Faculty Publications

Purpose/objectives: Due to higher radiosensitivity, non‐target normal tissue dose is a major concern in stereotactic body radiation therapy (SBRT) treatment. The aim of this report was to estimate the dosimetric impact, specifically the reduction of normal lung dose in the treatment of single‐isocenter/two‐lesion lung SBRT via volumetric modulated arc therapy with jaw tracking (JT‐VMAT).

Materials/methods: Twelve patients with two peripherally located early‐stage non‐small‐cell‐lung cancer (NSCLC) lung lesions underwent single‐isocenter highly conformal non‐coplanar JT‐VMAT SBRT treatment in our institution. The mean isocenter to tumors distance was 5.6 ± 1.9 (range 4.3–9.5) cm. The mean combined planning target volume (PTV) was 38.7 …


Evaluation Of Plan Quality And Treatment Efficiency For Single-Isocenter/Two-Lesion Lung Stereotactic Body Radiation Therapy, Lana Sanford, Janelle A. Molloy, Sameera S. Kumar, Marcus Randall, Ronald C. Mcgarry, Damodar Pokhrel Jan 2019

Evaluation Of Plan Quality And Treatment Efficiency For Single-Isocenter/Two-Lesion Lung Stereotactic Body Radiation Therapy, Lana Sanford, Janelle A. Molloy, Sameera S. Kumar, Marcus Randall, Ronald C. Mcgarry, Damodar Pokhrel

Radiation Medicine Faculty Publications

Purpose/objectives: To evaluate the plan quality and treatment delivery efficiency of single‐isocenter/two‐lesions volumetric modulated arc therapy (VMAT) lung stereotactic body radiation therapy (SBRT).

Materials/methods: Eight consecutive patients with two peripherally located early stage nonsmall‐cell‐lung cancer (NSCLC) lung lesions underwent single‐isocenter highly conformal noncoplanar VMAT SBRT treatment in our institution. A single‐isocenter was placed between the two lesions. Doses were 54 or 50 Gy in 3 and 5 fractions respectively. Patients were treated every other day. Plans were calculated in Eclipse with AcurosXB algorithm and normalized to at least 95% of the planning target volume (PTV) receiving 100% of the prescribed …