Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Life Sciences (96)
- Medical Specialties (95)
- Medical Sciences (89)
- Oncology (82)
- Bioinformatics (75)
-
- Biomedical Informatics (75)
- Physical Sciences and Mathematics (40)
- Physics (35)
- Genetic Phenomena (33)
- Medical Genetics (33)
- Health Services Research (25)
- Clinical Epidemiology (23)
- Community Health and Preventive Medicine (23)
- Epidemiology (23)
- Patient Safety (23)
- Health Services Administration (21)
- Public Health Education and Promotion (21)
- Environmental Public Health (20)
- Other Public Health (19)
- Diseases (17)
- International Public Health (17)
- Nuclear (17)
- Dietetics and Clinical Nutrition (13)
- Occupational Health and Industrial Hygiene (13)
- Food Science (11)
- Engineering (10)
- Nutrition (10)
- Institution
-
- The Texas Medical Center Library (82)
- Virginia Commonwealth University (21)
- University of Nevada, Las Vegas (20)
- Montclair State University (19)
- Louisiana State University (15)
-
- Institut de Recherche Robert-Sauvé en santé et en sécurité du travail (6)
- College of Saint Benedict and Saint John's University (5)
- University of Arkansas, Fayetteville (4)
- University of Kentucky (3)
- University of Tennessee, Knoxville (3)
- University of Texas at Arlington (2)
- Aga Khan University (1)
- Georgia Southern University (1)
- Illinois Math and Science Academy (1)
- LSU Health New Orleans (1)
- SASTRA Deemed to be University (1)
- University of Central Florida (1)
- University of Louisville (1)
- University of Nebraska Medical Center (1)
- University of New Mexico (1)
- University of South Carolina (1)
- Wayne State University (1)
- Keyword
-
- Humans (70)
- Computer-Assisted (34)
- Radiotherapy Planning, Computer-Assisted (33)
- Radiotherapy Dosage (31)
- Radiotherapy Planning (27)
-
- Radiotherapy (22)
- Radiotherapy, Intensity-Modulated (22)
- Organs at Risk (18)
- Intensity-Modulated (17)
- Imaging (16)
- Tomography (16)
- Female (15)
- Phantoms (15)
- Accelerator-driven systems; Radiation dosimetry; Radioisotopes – Measurement; Spallation (Nuclear physics) (14)
- Algorithms (12)
- Radiometry (12)
- X-Ray Computed (12)
- Image Processing (11)
- Phantoms, Imaging (11)
- Image Processing, Computer-Assisted (10)
- Magnetic Resonance Imaging (10)
- Tomography, X-Ray Computed (10)
- Male (9)
- Quality assurance (9)
- Retrospective Studies (9)
- Deep Learning (8)
- Neoplasms (8)
- Particle Accelerators (8)
- Deep learning (7)
- Mexico (7)
- Publication Year
- Publication
-
- Faculty, Staff and Student Publications (78)
- Theses and Dissertations (22)
- Department of Public Health Scholarship and Creative Works (18)
- Transmutation Sciences Physics (TRP) (17)
- LSU Doctoral Dissertations (8)
-
- LSU Master's Theses (7)
- Études primaires (6)
- Dissertations and Theses (Open Access) (4)
- Graduate Theses and Dissertations (4)
- Physics Faculty Publications (4)
- International Journal of Nuclear Security (3)
- Radiation Medicine Faculty Publications (2)
- College of Graduate Studies: Theses & Dissertations (1)
- Department of Nutrition and Food Studies Scholarship and Creative Works (1)
- Doctor of Nursing Practice (DNP) Scholarly Projects - Archive (1)
- Electronic Theses and Dissertations (1)
- Environmental & Global Health Faculty Research (1)
- Health Physics and Diagnostic Sciences Faculty Research (1)
- Honors Theses, 1963-2015 (1)
- Honors Undergraduate Theses (1)
- Imaging & Diagnostic Radiology, East Africa (1)
- Physics & Astronomy ETDs (1)
- School of Medicine Faculty Publications (1)
- Senior Theses (1)
- Social Work Dissertations - Archive (1)
- Student Publications & Research (1)
- Theses & Dissertations (1)
- Theses and Dissertations--Radiation Medicine (1)
- UNLV Theses, Dissertations, Professional Papers, and Capstones (1)
- Wayne State University Dissertations (1)
- Publication Type
Articles 151 - 180 of 191
Full-Text Articles in Health and Medical Physics
Statistical Modeling Of Interfractional Tissue Deformation And Its Application In Radiation Therapy Planning, Douglas J. Vile
Statistical Modeling Of Interfractional Tissue Deformation And Its Application In Radiation Therapy Planning, Douglas J. Vile
Theses and Dissertations
In radiation therapy, interfraction organ motion introduces a level of geometric uncertainty into the planning process. Plans, which are typically based upon a single instance of anatomy, must be robust against daily anatomical variations. For this problem, a model of the magnitude, direction, and likelihood of deformation is useful. In this thesis, principal component analysis (PCA) is used to statistically model the 3D organ motion for 19 prostate cancer patients, each with 8-13 fractional computed tomography (CT) images. Deformable image registration and the resultant displacement vector fields (DVFs) are used to quantify the interfraction systematic and random motion. By applying …
Hybrid Pet/Mri Nanoparticle Development And Multi-Modal Imaging, David Hoffman
Hybrid Pet/Mri Nanoparticle Development And Multi-Modal Imaging, David Hoffman
Theses and Dissertations
The development of hybrid PET/MRI imaging systems needs to be paralleled with the development of a hybrid intrinsic PET/MRI probes. The aim of this work was to develop and validate a novel radio-superparamagnetic nanoparticle (r-SPNP) for hybrid PET/MRI imaging. This was achieved with the synthesis of superparamagnetic iron oxide nanoparticles (SPIONs) that intrinsically incorporated 59Fe and manganese iron oxide nanoparticles (MIONs) that intrinsically incorporated 52Mn. Both [59Fe]-SPIONs and [52Mn]-MIONs were produced through thermal decomposition synthesis. The physiochemical characteristics of the r-SPNPs were assessed with TEM, DLS, and zeta-potential measurements, as well as in imaging phantom studies. The [59Fe]-SPIONs were evaluated …
Positron Emission Tomography For Pre-Clinical Sub-Volume Dose Escalation, Christopher Bass
Positron Emission Tomography For Pre-Clinical Sub-Volume Dose Escalation, Christopher Bass
Theses and Dissertations
Purpose: This dissertation focuses on establishment of pre-clinical methods facilitating the use of PET imaging for selective sub-volume dose escalation. Specifically the problems addressed are 1.) The difficulties associated with comparing multiple PET images, 2.) The need for further validation of novel PET tracers before their implementation in dose escalation schema and 3.) The lack of concrete pre-clinical data supporting the use of PET images for guidance of selective sub-volume dose escalations. Methods and materials: In order to compare multiple PET images the confounding effects of mispositioning and anatomical change between imaging sessions needed to be alleviated. To mitigate the …
Principled Variance Reduction Techniques For Real Time Patient-Specific Monte Carlo Applications Within Brachytherapy And Cone-Beam Computed Tomography, Andrew Sampson
Theses and Dissertations
This dissertation describes the application of two principled variance reduction strategies to increase the efficiency for two applications within medical physics. The first, called correlated Monte Carlo (CMC) applies to patient-specific, permanent-seed brachytherapy (PSB) dose calculations. The second, called adjoint-biased forward Monte Carlo (ABFMC), is used to compute cone-beam computed tomography (CBCT) scatter projections. CMC was applied for two PSB cases: a clinical post-implant prostate, and a breast with a simulated lumpectomy cavity. CMC computes the dose difference between the highly correlated dose computing homogeneous and heterogeneous geometries. The particle transport in the heterogeneous geometry assumed a purely homogeneous environment, …
Time Dependent Cone-Beam Ct Reconstruction Via A Motion Model Optimized With Forward Iterative Projection Matching, David Staub
Time Dependent Cone-Beam Ct Reconstruction Via A Motion Model Optimized With Forward Iterative Projection Matching, David Staub
Theses and Dissertations
The purpose of this work is to present the development and validation of a novel method for reconstructing time-dependent, or 4D, cone-beam CT (4DCBCT) images. 4DCBCT can have a variety of applications in the radiotherapy of moving targets, such as lung tumors, including treatment planning, dose verification, and real time treatment adaptation. However, in its current incarnation it suffers from poor reconstruction quality and limited temporal resolution that may restrict its efficacy. Our algorithm remedies these issues by deforming a previously acquired high quality reference fan-beam CT (FBCT) to match the projection data in the 4DCBCT data-set, essentially creating a …
Automatic Block-Matching Registration To Improve Lung Tumor Localization During Image-Guided Radiotherapy, Scott Robertson
Automatic Block-Matching Registration To Improve Lung Tumor Localization During Image-Guided Radiotherapy, Scott Robertson
Theses and Dissertations
To improve relatively poor outcomes for locally-advanced lung cancer patients, many current efforts are dedicated to minimizing uncertainties in radiotherapy. This enables the isotoxic delivery of escalated tumor doses, leading to better local tumor control. The current dissertation specifically addresses inter-fractional uncertainties resulting from patient setup variability. An automatic block-matching registration (BMR) algorithm is implemented and evaluated for the purpose of directly localizing advanced-stage lung tumors during image-guided radiation therapy. In this algorithm, small image sub-volumes, termed “blocks”, are automatically identified on the tumor surface in an initial planning computed tomography (CT) image. Each block is independently and automatically registered …
A Study Of Coverage Optimized Planning Incorporating Models Of Geometric Uncertainties For Prostate Cancer, Huijun Xu
Theses and Dissertations
A fundamental challenge in the treatment planning process of multi-fractional external-beam radiation therapy (EBRT) is the tradeoff between tumor control and normal tissue sparing in the presence of geometric uncertainties (GUs). To accommodate GUs, the conventional way is to use an empirical planning treatment volume (PTV) margin on the treatment target. However, it is difficult to determine a near-optimal PTV margin to ensure specified target coverage with as much normal tissue protection as achievable. Coverage optimized planning (COP) avoids this problem by optimizing dose in possible virtual treatment courses with GU models directly incorporated. A near-optimal dosimetric margin generated by …
Optimization Of Radiation Therapy In Time-Dependent Anatomy, W. Tyler Watkins
Optimization Of Radiation Therapy In Time-Dependent Anatomy, W. Tyler Watkins
Theses and Dissertations
The objective of this dissertation is to develop treatment planning techniques that have the potential to improve radiation therapy of time-dependent (4D) anatomy. Specifically, this study examines dose estimation, dose evaluation, and decision making in the context of optimizing lung cancer radiation therapy. Two methods of dose estimation are compared in patients with locally advanced and early stage lung cancer: dose computed on a single image (3D-dose) and deformably registered, accumulated dose (or 4D-dose). The results indicate that differences between 3D- and 4D- dose are not significant in organs at risk (OARs), however, 4D-dose to a moving lung cancer target …
Epid-Based Dose Verification For Adaptive Radiotherapy, Joseph Gardner
Epid-Based Dose Verification For Adaptive Radiotherapy, Joseph Gardner
Theses and Dissertations
Dose verification is a critical component of adaptive radiotherapy, as it provides a measurement of treatment delivery success. Based on the measured outcome, the plan may be adapted to account for differences between the planned dose and the delivered dose. Although placement of an EPID behind the patient during treatment allows for exit dosimetry which may be used to reconstruct the delivered patient dose via backprojection of the fluence, there have not been any studies examining the basic assumption of backprojection-based dose verification: that deviations between the expected and delivered exit fluences are totally caused by errors in the delivered …
Fabrication And Characterization Of Thinner Solid-State Nanopores, Denis Forbi Tita
Fabrication And Characterization Of Thinner Solid-State Nanopores, Denis Forbi Tita
Graduate Theses and Dissertations
Solid State nanopores that are fabricated by the ion beam sculpting process and electron beam drilling have shown great promise as a sensing device for DNA and protein molecules. Even though biological pores such as the alpha-Haemolysin have been in use for quite some time, the use of solid state Nanopores in single biomolecule detection has been on the rise since the mid 1990s. Solid State nanopores have an advantage over biological pores in that they are more robust, stable, and can be sculpted to any desired size for use in translocation experiments. One of the major challenges in Nanopore …
Validation Of 3'-Deoxy-3'-[18f]-Fluorothymidine Positron Emission Tomography For Image-Guidance In Biologically Adaptive Radiotherapy, Marian Axente
Validation Of 3'-Deoxy-3'-[18f]-Fluorothymidine Positron Emission Tomography For Image-Guidance In Biologically Adaptive Radiotherapy, Marian Axente
Theses and Dissertations
Accelerated tumor cell repopulation during radiation therapy is one of the leading causes for low survival rates of head-and-neck cancer patients. The therapeutic effectiveness of radiotherapy could be improved by selectively targeting proliferating tumor subvolumes with higher doses of radiation. Positron emission tomography (PET) imaging with 3´-deoxy-3´-[18F]-fluorothymidine (FLT) has shown great potential as a non-invasive approach to characterizing the proliferation status of tumors. This thesis focuses on histopathological validation of FLT PET imaging specifically for image-guidance applications in biologically adaptive radiotherapy. The lack of experimental data supporting the use of FLT PET imaging for radiotherapy guidance is addressed by developing …
A Quantitative Method For Reproducible Ionization Chamber Alignment To A Water Surface For External Beam Radiation Therapy Depth Dose Measurements, James Ververs
Theses and Dissertations
Ionization chambers (ICs) are the most commonly used detectors for radiation therapy dose measurements. Typical IC measurements use cylindrical ICs in a water phantom and therefore require initial IC alignment to the water surface. This alignment has long been ignored and only recently has a qualitative governing recommendation been made. This thesis describes a reproducible methodology for quantitative ionization chamber water surface alignment. Depth-ionization measurements are taken with twenty-eight IC designs under varying conditions including, but not limited to, changes in scan direction, speed, and resolution, radiation beam type, field size, energy, and electron contamination. Measurements are acquired using standard …
Development Of Dose Conversion Coefficients For Radionuclides Produced In Spallation Neutron Sources, Phillip W. Patton
Development Of Dose Conversion Coefficients For Radionuclides Produced In Spallation Neutron Sources, Phillip W. Patton
Transmutation Sciences Physics (TRP)
A research consortium comprised of representatives from several universities and national laboratories will be established as part of this project to generate internal and external dose conversion coefficients for radionuclides produced in spallation neutron sources. Information obtained from this multi-year study will be used to support the siting and licensing of future accelerator-driven nuclear initiatives within the U.S. Department of Energy complex, including the Spallation Neutron Source (SNS) and Accelerator Production of Tritium (APT) projects. Determination of these coefficients will also fill data gaps for several hundred radionuclides that exist in Federal Guidance Report (FGR) No. 11 and in Publications …
Statistical Image Reconstruction For Quantitative Computed Tomography, Joshua Evans
Statistical Image Reconstruction For Quantitative Computed Tomography, Joshua Evans
Theses and Dissertations
Statistical iterative reconstruction (SIR) algorithms for x-ray computed tomography (CT) have the potential to reconstruct images with less noise and systematic error than the conventional filtered backprojection (FBP) algorithm. More accurate reconstruction algorithms are important for reducing imaging dose and for a wide range of quantitative CT applications. The work presented herein investigates some potential advantages of one such statistically motivated algorithm called Alternating Minimization (AM). A simulation study is used to compare the tradeoff between noise and resolution in images reconstructed with the AM and FBP algorithms. The AM algorithm is employed with an edge-preserving penalty function, which is …
Radiation Therapy Treatment Plan Optimization Accounting For Random And Systematic Patient Setup Uncertainties, Joseph Moore
Radiation Therapy Treatment Plan Optimization Accounting For Random And Systematic Patient Setup Uncertainties, Joseph Moore
Theses and Dissertations
External-beam radiotherapy is one of the primary methods for treating cancer. Typically a radiotherapy treatment course consists of radiation delivered to the patient in multiple daily treatment fractions over 6-8 weeks. Each fraction requires the patient to be aligned with the image acquired before the treatment course used in treatment planning. Unfortunately, patient alignment is not perfect and results in residual errors in patient setup. The standard technique for dealing with errors in patient setup is to expand the volume of the target by some margin to ensure the target receives the planned dose in the presence of setup errors. …
Characterization Of A Blast Wave Device And Blast Wave Induced Traumatic Brain Injury In A Rat Model By Magnetic Resonance Imaging And Spectroscopy, Frank Corwin
Theses and Dissertations
Blast wave induced traumatic brain injury (bTBI) is a modality of injury that has come into prominence at the current time due to the large number of military and civilian personnel who have experienced the localized shock wave produced by explosive devices. The shock wave will travel concentrically outward from the explosive center, being absorbed and transmitted thru soft objects, such as tissue, and reflecting off stationary obstructions. Transmission and absorption in tissues can result in a number of physiological measureable injuries, the most common of which being what is frequently called “blast lung”. Blast lung involves the spalling effect …
Brachytherapy Seed And Applicator Localization Via Iterative Forward Projection Matching Algorithm Using Digital X-Ray Projections, Damodar Pokhrel
Brachytherapy Seed And Applicator Localization Via Iterative Forward Projection Matching Algorithm Using Digital X-Ray Projections, Damodar Pokhrel
Theses and Dissertations
Interstitial and intracavitary brachytherapy plays an essential role in management of several malignancies. However, the achievable accuracy of brachytherapy treatment for prostate and cervical cancer is limited due to the lack of intraoperative planning and adaptive replanning. A major problem in implementing TRUS-based intraoperative planning is an inability of TRUS to accurately localize individual seed poses (positions and orientations) relative to the prostate volume during or after the implantation. For the locally advanced cervical cancer patient, manual drawing of the source positions on orthogonal films can not localize the full 3D intracavitary brachytherapy (ICB) applicator geometry. A new iterative forward …
Adaptive Radiation Therapy Of Prostate Cancer, Ning Wen
Adaptive Radiation Therapy Of Prostate Cancer, Ning Wen
Wayne State University Dissertations
ART is a close-loop feedback algorithm which evaluates the organ deformation and motion right before the treatment and takes into account dose delivery variation daily to compensate for the difference between planned and delivered dose. It also has potential to allow further dose escalation and margin reduction to improve the clinical outcome. This retrospective study evaluated ART for prostate cancer treatment and radiobiological consequences. An IRB approved protocol has been used to evaluate actual dose delivery of patients with prostate cancer undergoing treatment with daily CBCT.
The dose from CBCT was measured in phantom using TLD and ion chamber techniques …
Need For Cognition And Message Complexity In Motivating Fruit And Vegetable Intake Among Callers To The Cancer Information Service, Pamela Williams-Piehota, Judith Pizarro, Stephanie A. Navarro Silvera, Linda Mowad, Peter Salovey
Need For Cognition And Message Complexity In Motivating Fruit And Vegetable Intake Among Callers To The Cancer Information Service, Pamela Williams-Piehota, Judith Pizarro, Stephanie A. Navarro Silvera, Linda Mowad, Peter Salovey
Department of Public Health Scholarship and Creative Works
This field experiment examined the impact of an individual's need for cognition (NFC; the tendency to enjoy thinking deeply about issues), complex versus simple messages, and the interaction of NFC and message type on encouraging fruit and vegetable consumption. Callers to the Cancer Information Service of the National Cancer Institute (N = 517) were asked to participate in the experiment at the end of their call. Individual NFC was assessed, and participants were assigned randomly to receive a telephone message promoting fruit and vegetable consumption that was either complex and multifaceted or simple and straightforward. Similarly constructed brochures were mailed …
Development Of Dose Coefficients For Radionuclides Produced In Spallation Targets, Phillip W. Patton, Mark Rudin
Development Of Dose Coefficients For Radionuclides Produced In Spallation Targets, Phillip W. Patton, Mark Rudin
Transmutation Sciences Physics (TRP)
Dose coefficients permit simple determination of radiation dose associated with various exposure scenarios, and ultimately permit radiation safety personnel to assess the health risks to workers in a nuclear facility. Specifically, radiation safety personnel use dose coefficients to determine the radiation dose incurred to a tissue or organ system from a given exposure. These parameters are often expressed in terms of Annual Limits on Intake (ALIs) and Derived Air Concentrations (DACs).
The research consortium comprised of representatives from several universities and national laboratories has successfully generated internal and external dose conversion coefficients for twenty radionuclides produced in spallation neutron sources. …
Development Of Dose Conversion Coefficients For Radionuclides Produced In Spallation Neutron Sources Quarterly Progress Report 4/01/05 – 6/30/05, Phillip W. Patton, Mark Rudin
Development Of Dose Conversion Coefficients For Radionuclides Produced In Spallation Neutron Sources Quarterly Progress Report 4/01/05 – 6/30/05, Phillip W. Patton, Mark Rudin
Transmutation Sciences Physics (TRP)
The research consortium comprised of representatives from several universities and national laboratories has successfully generated internal and external dose conversion coefficients for twenty radionuclides produced in spallation neutron sources. These dose coefficients fill data gaps exist in Federal Guide Report No. 11 and in Publications 68 and 72 of the International Commission on Radiological Protection (ICRP), and two articles containing the data have been accepted for publication in the Journal of Health Physics. Currently, more nuclear data is needed for the rare radionuclides produced from a mercury target. While attempting to develop a workable plan to acquire this missing data, …
Development Of Dose Conversion Coefficients For Radionuclides Produced In Spallation Neutron Sources Quarterly Progress Report 1/1/05 – 3/31/05, Phillip W. Patton, Mark Rudin
Development Of Dose Conversion Coefficients For Radionuclides Produced In Spallation Neutron Sources Quarterly Progress Report 1/1/05 – 3/31/05, Phillip W. Patton, Mark Rudin
Transmutation Sciences Physics (TRP)
The research consortium comprised of representatives from several universities and national laboratories has successfully generated internal and external dose conversion coefficients for twenty radionuclides produced in spallation neutron sources. In addition, the group has identified twenty radionuclide that are missing electron capture files and eighteen additional radionuclides missing substantial physical data. The goal for the current year is to develop a methodology that will allow for producing the dose coefficients for these radionuclides with missing data. Methods to obtain these data are being investigated.
Development Of Dose Coefficients For Radionuclides Produced In Spallation Targets, Phillip W. Patton, Mark Rudin
Development Of Dose Coefficients For Radionuclides Produced In Spallation Targets, Phillip W. Patton, Mark Rudin
Transmutation Sciences Physics (TRP)
Dose coefficients permit simple determination of radiation dose associated with various exposure scenarios, and ultimately permit radiation safety personnel to assess the health risks to workers in a nuclear facility. Specifically, radiation safety personnel use dose coefficients to determine the radiation dose incurred to a tissue or organ system from a given exposure. These parameters are often expressed in terms of Annual Limits on Intake (ALIs) and Derived Air Concentrations (DACs).
The research consortium comprised of representatives from several universities and national laboratories has successfully generated internal and external dose conversion coefficients for twenty radionuclides produced in spallation neutron sources. …
Development Of Dose Conversion Coefficients For Radionuclides Produced In Spallation Neutron Sources: Quarterly Progress Report 9/1/04 – 12/31/04, Phillip W. Patton, Mark Rudin
Development Of Dose Conversion Coefficients For Radionuclides Produced In Spallation Neutron Sources: Quarterly Progress Report 9/1/04 – 12/31/04, Phillip W. Patton, Mark Rudin
Transmutation Sciences Physics (TRP)
The research consortium comprised of representatives from several universities and national laboratories has successfully generated internal and external dose conversion coefficients for twenty radionuclides produced in spallation neutron sources. In addition, the group has identified twenty radionuclide that are missing electron capture files and eighteen additional radionuclides missing substantial physical data.
Development Of Dose Conversion Coefficients For Radionuclides Produced In Spallation Neutron Sources: Quarterly Progress Report 5/1/04 – 8/31/04, Phillip W. Patton, Mark Rudin
Development Of Dose Conversion Coefficients For Radionuclides Produced In Spallation Neutron Sources: Quarterly Progress Report 5/1/04 – 8/31/04, Phillip W. Patton, Mark Rudin
Transmutation Sciences Physics (TRP)
The research consortium comprised of representatives from several universities and national laboratories has successfully generated internal and external dose conversion coefficients for twenty radionuclides produced in spallation neutron sources. These dose coefficients fill data gaps exist in Federal Guide Report No. 11 and in Publications 68 and 72 of the International Commission on Radiological Protection (ICRP). Currently, more nuclear data is needed for the rare radionuclides produced from a mercury target.
Development Of Dose Coefficients For Radionuclides Produced In Spallation Targets, Phillip W. Patton, Mark Rudin
Development Of Dose Coefficients For Radionuclides Produced In Spallation Targets, Phillip W. Patton, Mark Rudin
Transmutation Sciences Physics (TRP)
Dose coefficients permit simple determination of radiation dose associated with various exposure scenarios, and ultimately permit radiation safety personnel to assess the health risks to workers in a nuclear facility. Specifically, radiation safety personnel use dose coefficients to determine the radiation dose incurred to a tissue or organ system from a given exposure. These parameters are often expressed in terms of Annual Limits on Intake (ALIs) and Derived Air Concentrations (DACs).
Results from this study will be used to produce ALIs and DACs for these rare radionuclides created by spallation target systems that are not included in Federal Guidance Report …
Development Of Dose Conversion Coefficients For Radionuclides Produced In Spallation Neutron Sources: Quarterly Progress Report 8/20/03 – 12/01/03, Phillip W. Patton, Mark Rudin
Development Of Dose Conversion Coefficients For Radionuclides Produced In Spallation Neutron Sources: Quarterly Progress Report 8/20/03 – 12/01/03, Phillip W. Patton, Mark Rudin
Transmutation Sciences Physics (TRP)
A research consortium comprised of representatives from several universities and national laboratories has been established as part of this project to generate internal and external dose conversion coefficients for radionuclides produced in spallation neutron sources. Information obtained from this multi-year study will be used to support the siting and licensing of future accelerator-driven nuclear initiatives within the U.S. Department of Energy complex, including the Spallation Neutron Source (SNS) and Accelerator Production of Tritium (APT) Projects. Determination of these coefficients will also fill data gaps for several hundred radionuclides that exist in Federal Guide Report No. 11 and in Publications 68 …
Decreasing Barriers For Teens: Evaluation Of A New Teenage Pregnancy Prevention Strategy In School-Based Clinics, Abbey C. Sidebottom, Amanda Birnbaum, Sarah S. Nafstad
Decreasing Barriers For Teens: Evaluation Of A New Teenage Pregnancy Prevention Strategy In School-Based Clinics, Abbey C. Sidebottom, Amanda Birnbaum, Sarah S. Nafstad
Department of Public Health Scholarship and Creative Works
Sidebottom et al seek to evaluate the effects of the change in distribution systems on students' receipt of requested contraceptives and demand for contraceptive school-based clinics (SBC). The result of the study reveals that the average number of requests per student was higher under the voucher system, possibly as a consequence of expires vouchers resulting in repeated requests. The findings also suggest that SBCs could go a step further in reducing adolescents' barriers to accessing contraceptives by adopting an on-site direct delivery system..
Dose Coefficients For Radionuclides Produced In A Spallation Neutron Source, John P. Shanahan
Dose Coefficients For Radionuclides Produced In A Spallation Neutron Source, John P. Shanahan
Transmutation Sciences Physics (TRP)
Internal and external dose coefficient values have been calculated for 14 anthropogenic radionuclides which are not currently presented in Federal Guidance Reports No. 11, 12, and 13 or Publications 68 and 72 of the International Commission on Radiological Protection. Internal dose coefficient values are reported for inhalation and ingestion of 1 μm and 5 μm particulates along with the f1 values and absorption types for the adult worker. Internal dose coefficient values are also reported for inhalation and ingestion of 1 μm particulates as well as the f1 values and absorption types for members of the public. Additionally, external dose …
Development Of Dose Coefficients For Radionuclides Produced In Spallation Neutron Sources, Phillip W. Patton
Development Of Dose Coefficients For Radionuclides Produced In Spallation Neutron Sources, Phillip W. Patton
Transmutation Sciences Physics (TRP)
A research consortium comprised of representatives from several universities and national laboratories has been established as part of this on-going project to generate internal and external dose conversion coefficients for radionuclides produced in spallation neutron sources. Information obtained from this multi-year study will be used to support the siting and licensing of future accelerator-driven nuclear initiatives within the U.S. Department of Energy complex, including the Spallation Neutron Source (SNS) and the Advanced Fuel Cycle Initiative (AFCI) Projects. Determination of these coefficients will also fill data gaps for several hundred radionuclides that exist in Federal Guide Report No. 11 and in …