Open Access. Powered by Scholars. Published by Universities.®

Mechanical Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering

Institution
Keyword
Publication Year
Publication
Publication Type
File Type

Articles 751 - 780 of 989

Full-Text Articles in Mechanical Engineering

Anisotropy Evolution Due To Surface Treatment On 3d-Printed Fused Deposition Modeling (Fdm) Of Acrylonitrile Butadiene Styrene (Abs), Blake E. Lozinski Jan 2017

Anisotropy Evolution Due To Surface Treatment On 3d-Printed Fused Deposition Modeling (Fdm) Of Acrylonitrile Butadiene Styrene (Abs), Blake E. Lozinski

Honors Undergraduate Theses

Purpose: This paper will present insight to the methodology and results of the experimental characterization of Acrylonitrile Butadiene Styrene (ABS) using Fused Deposition Modeling (FDM). The work in this research explored the effects of print orientation, surface treatment, and ultraviolet (UV) light degradation with the utilization of Digital Image Correlation (DIC) on ABS tensile specimens.

Design/methodology: ABS specimens were printed at three build orientations (flat (0 degrees), 45 degrees, and up-right (90 degrees)). Each of these specimens were treated with three different surface treatments including a control (acrylic paint, Cyanoacrylate, and Diglycidyl Bisphenol A) followed by exposure to UV light …


Development Of A Finite Element Pelvis And Lower Extremity Model With Growth Plates For Pediatric Pedestrian Protection, Ming Shen Jan 2017

Development Of A Finite Element Pelvis And Lower Extremity Model With Growth Plates For Pediatric Pedestrian Protection, Ming Shen

Wayne State University Dissertations

Finite element (FE) model is a useful tool frequently used for investigating the injury mechanisms and designing protection countermeasures. At present, no 10 years old (YO) pedestrian FE model has been developed from appropriate anthropometries and validated against limitedly available impact response data. A 10 YO child FE pelvis and lower extremities (PLEX) model was established to fill the gap of lacking such models in this age group. The baseline model was validated against available pediatric postmortem human subjects (PMHS) test data and additional scaled adult data, then the PLEX model was integrated to build a whole-body FE model representing …


Age-Related Differences In The Lumbopelvic Kinematics During The Trunk Motions In The Anatomical Planes, Milad Vazirian Jan 2017

Age-Related Differences In The Lumbopelvic Kinematics During The Trunk Motions In The Anatomical Planes, Milad Vazirian

Theses and Dissertations--Biomedical Engineering

Management and control of the low back pain as an important health problem in the industrial societies necessitates to investigate how the risk of this disease is affected by aging. Since the abnormalities of the lumbopelvic kinematics are related to the existence or risk of low back injuries, the objective of this dissertation was set to find the age-related differences in lumbopelvic kinematics when performing basic trunk motions reaching to range of motion in different anatomical planes.

A cross-sectional study was designed where sixty asymptomatic individuals between 20–70 years old with no confounding health condition, no current or previous highly …


Shape Memory Behavior Of Dense And Porous Niti Alloys Fabricated By Selective Laser Melting, Soheil Saedi Jan 2017

Shape Memory Behavior Of Dense And Porous Niti Alloys Fabricated By Selective Laser Melting, Soheil Saedi

Theses and Dissertations--Mechanical and Aerospace Engineering

Selective Laser Melting (SLM) of Additive Manufacturing is an attractive fabrication method that employs CAD data to selectively melt the metal powder layer by layer via a laser beam and produce a 3D part. This method not only opens a new window in overcoming traditional NiTi fabrication problems but also for producing porous or complex shaped structures. The combination of SLM fabrication advantages with the unique properties of NiTi alloys, such as shape memory effect, superelasticity, high ductility, work output, corrosion, biocompatibility, etc. makes SLM NiTi alloys extremely promising for numerous applications.

The SLM process parameters such as laser power, …


Skintronics: Wireless, Skin-Wearable Electronics For Monitoring Of Electrocardiogram, Matthew B. Piper, Woon-Hong Yeo, Yongkuk Lee Jan 2017

Skintronics: Wireless, Skin-Wearable Electronics For Monitoring Of Electrocardiogram, Matthew B. Piper, Woon-Hong Yeo, Yongkuk Lee

Undergraduate Research Posters

The ECGs I micro-fabricate are designed to be flexible, stretchable and wireless circuits that can be applied to the skin directly. The device is encased in a conformal, silicon-like substrate, that allows the ECG to be attached with the electrodes. Each electrode has been previously measured and verified that it will be correctly placed for an accurate reading. Prototyping this ECG/electrode device allows the user to mount the prototype directly to the patient without having to attach and wire ten other electrodes. This prototype solves the issue that comes about when a doctor, nurse or emergency medical technician must attach …


Computational Studies On Biomechanics Of Concussion And On Efficacy Of Football Helmets, David Labyak Jan 2017

Computational Studies On Biomechanics Of Concussion And On Efficacy Of Football Helmets, David Labyak

Dissertations, Master's Theses and Master's Reports

Football helmets have been used for many years to prevent head injuries to players. Over the years, the helmet design has evolved from a crude leather head covering to the more recent form fitting helmets that are seen today. The one design feature that has been common in the majority of all helmets is a hard polycarbonate shell with a foam cushion padding. The main goal of the padding layer was to reduce the amount of linear acceleration during an impact event. The one feature that has been overlooked is how stiff the padding is in rotation.

The purpose of …


Statistical Shape Modeling To Quantify Variation In The Proximal Humeral Anatomy, Paul B. Sade Sr. Jan 2017

Statistical Shape Modeling To Quantify Variation In The Proximal Humeral Anatomy, Paul B. Sade Sr.

Electronic Theses and Dissertations

The fit of the humeral prosthesis to the intramedullary canal and the replication of the anatomic humeral head center are important factors in Total Shoulder Arthroplasty (TSA). The objective of this thesis was to develop a Statistical Shape Model (SSM) of the cortical and cancellous bone regions of the proximal humerus, and to assess potential shape differences with gender and ethnicity, with a goal of informing implant design. An SSM was used and Principal Component Analysis (PCA) was applied to data that represented both the cancellous and cortical humeral bone of 63 healthy subjects and cadavers. Anatomical measurements and PC …


Development & Validation Of An Improved Biomechanical Model For Motion Analysis, Darren Dawson Jan 2017

Development & Validation Of An Improved Biomechanical Model For Motion Analysis, Darren Dawson

Theses

Three dimensional motion analysis systems are utilised across a number of different disciplines, including clinical gait analysis, sports performance studies and analysis of tasks of daily living. These systems utilise biomechanical models which define body segment coordinate systems and calculate kinematic and kinetic relationships about the joints between adjacent coordinate systems. In this study, a biomechanical model for general use in motion analysis was developed and validated. It was designed to improve upon the accuracy and capability of currently available models. The newly developed model utilises state of the art techniques to accurately define body segment coordinate systems. Accurate predictive …


Shear Driven Micro-Fluidic Pump, Nihad E. Daidzic Dec 2016

Shear Driven Micro-Fluidic Pump, Nihad E. Daidzic

Aviation Department Publications

United States Patent, Patent Number US 9,528,503 B2, Date of Patent December 27, 2016.

An example includes an apparatus to pump a fluid. The apparatus includes a housing extending along a length defining an elongate interior, an actuator in the housing, conforming to the elongate interior, the actuator including a plurality of lumens, each having a length extending substantially parallel to the elongate interior, each from around 10 to 200 micrometers across and an actuator configured to oscillate the actuator in the actuator houslng along the length of the elongate interior with a rate differential between movement in a first …


Finite Element Simulation And Additive Manufacturing Of Stiffness-Matched Niti Fixation Hardware For Mandibular Reconstruction Surgery, Ahmadreza Jahadakbar, Narges Shayesteh Moghaddam, Amirhesam Amerinatanzi, David Dean, Haluk E. Karaca, Mohammad Elahinia Dec 2016

Finite Element Simulation And Additive Manufacturing Of Stiffness-Matched Niti Fixation Hardware For Mandibular Reconstruction Surgery, Ahmadreza Jahadakbar, Narges Shayesteh Moghaddam, Amirhesam Amerinatanzi, David Dean, Haluk E. Karaca, Mohammad Elahinia

Mechanical Engineering Faculty Publications

Process parameters and post-processing heat treatment techniques have been developed to produce both shape memory and superelastic NiTi using Additive Manufacturing. By introducing engineered porosity, the stiffness of NiTi can be tuned to the level closely matching cortical bone. Using additively manufactured porous superelastic NiTi, we have proposed the use of patient-specific, stiffness-matched fixation hardware, for mandible skeletal reconstructive surgery. Currently, Ti-6Al-4V is the most commonly used material for skeletal fixation devices. Although this material offers more than sufficient strength for immobilization during the bone healing process, the high stiffness of Ti-6Al-4V implants can cause stress shielding. In this paper, …


Design Of A Modified Stewart Platform Manipulator For Misalignment Correction, Adekunle Ayoko Dec 2016

Design Of A Modified Stewart Platform Manipulator For Misalignment Correction, Adekunle Ayoko

Master of Technology Management Plan II Graduate Projects

This thesis work is about the design of a modified Stewart platform manipulator for misalignment correction. The common version of the Stewart platform uses six actuators. The traditional Stewart platform of this kind has a moving top plate and a fixed base plate. However, in this research, the modified design of the traditional Stewart platform is studied. It is designed to be an easy connect-disconnect platform that can wrap around different structures with different cross sections and symmetrically designed. It is able to adjust position easily by using four identical but independent linear actuators populated evenly in two parts fastened …


A Validated Software Application To Measure Fiber Organization In Soft Tissue, Erica E. Morrill, Azamat N. Tulepbergenov, Christina J. Stender, Roshani Lamichhane, Raquel J. Brown, Trevor J. Lujan Dec 2016

A Validated Software Application To Measure Fiber Organization In Soft Tissue, Erica E. Morrill, Azamat N. Tulepbergenov, Christina J. Stender, Roshani Lamichhane, Raquel J. Brown, Trevor J. Lujan

Mechanical and Biomedical Engineering Faculty Publications and Presentations

The mechanical behavior of soft connective tissue is governed by a dense network of fibrillar proteins in the extracellular matrix. Characterization of this fibrous network requires the accurate extraction of descriptive structural parameters from imaging data, including fiber dispersion and mean fiber orientation. Common methods to quantify fiber parameters include fast Fourier transforms (FFT) and structure tensors, however, information is limited on the accuracy of these methods. In this study, we compared these two methods using test images of fiber networks with varying topology. The FFT method with a band-pass filter was the most accurate, with an error of 0.71 …


Final Design Report: Polymer Fatigue Characterization Test Method, Wyatt Ayling, Tyler Price, Brandon Stell, Michela Upson Dec 2016

Final Design Report: Polymer Fatigue Characterization Test Method, Wyatt Ayling, Tyler Price, Brandon Stell, Michela Upson

Mechanical Engineering

Polylogix is a team dedicated to the design, build, and testing of a fatigue machine to simulate cyclic loading on a biomedical polymer. This project is sponsored by Endologix, Inc. to provide test data characterizing mechanical material properties of various formulations of polymer used in abdominal aortic aneurysm surgeries. With this project goal, the machine must be able to test the polymer at body conditions; these include a testing temperature of 37°C and a cycling frequency ranging from 1 Hz to 10 Hz. This report proposes the following solution to this design challenge: an AC motor-driven mechanism utilizing a planetary …


Concurrent Detection And Isolation Of Cellular And Molecular Biomarkers, Wanfeng Huang Dec 2016

Concurrent Detection And Isolation Of Cellular And Molecular Biomarkers, Wanfeng Huang

Open Access Dissertations

Detection of cancer markers such as protein biomolecules and cancer cells in bodily fluids is of great importance in early diagnosis, prognosis as well as evaluation of therapy efficacy. Numerous devices have been developed for detecting either cellular or molecular targets, however there has not yet been a system that can simultaneously detect both cellular and molecular targets effectively. Molecule and cell-based assays are important because each type of target can tell a different story about the state of the disease and the two types of information can potentially be combined and/or compared for more accurate biological or clinical assessments. …


Knee Joint Internal Forces During Squat Jump Exercise, Ricardo Moreno Dec 2016

Knee Joint Internal Forces During Squat Jump Exercise, Ricardo Moreno

Theses and Dissertations

The purpose of this research is to investigate muscular ligament and joint contact forces produced during squat jump exercise. An inverse dynamics, two dimensional, leg model is used to describe the motion in the sagittal plane. The lower extremity model includes two bones, tibia and femur, tibio-femoral ligaments, and muscles such as quadriceps, hamstrings, and gastrocnemius. The ligaments are anatomically modeled as nonlinear strings, but the femoral condyle is modeled as a circle and the tibial plateau as a straight line. Experimental squat jump exercises are conducted to obtain the ground reaction forces, the angular accelerations, and centroid linear acceleration …


An Emg-Based Patient Monitoring System Using Zynq Soc Device, Farhad Fallahlalehzari Dec 2016

An Emg-Based Patient Monitoring System Using Zynq Soc Device, Farhad Fallahlalehzari

UNLV Theses, Dissertations, Professional Papers, and Capstones

This thesis describes the design, development, and testing of an EMG-based patient monitoring system using the Zynq device. Zynq is a system on chip device designed by Xilinx which consists of an ARM dual cortex-A9 processor as well as an FPGA integrated into one chip. This work also analyzes the performance of image-processing algorithms on this system and compares that performance to more traditional PC-based systems. Image processing algorithms, such as Sobel edge detection, dilation and erosion, could be used in conjunction with a camera for the patient monitoring purposes. These algorithms often perform sub-optimally on processors because of their …


Radiation Therapy And Dosing Material Transport Methodology, Robert O'Brien Dec 2016

Radiation Therapy And Dosing Material Transport Methodology, Robert O'Brien

UNLV Theses, Dissertations, Professional Papers, and Capstones

A technique is examined here that utilizes high energy beta decays from a short lived radioisotope to treat medical conditions such as shallow cancerous lesions. A major benefit of beta particle interaction in tissue is a fixed penetration depth for the charged particle, with dose limited to the ultimate range of the beta particle. This method improves on some current techniques of radioactive brachytherapy, where "seeds" are placed inside patients through temporary or permanent implantation in order to kill cancerous cells or inhibit growth of tissue. The use of low energy gamma-rays is the most common method of treatment currently …


The Effects Of Cryopreservation On Human Dental Pulp-Derived Mesenchymal Stem Cells, Allison Elaine Tomlin Dec 2016

The Effects Of Cryopreservation On Human Dental Pulp-Derived Mesenchymal Stem Cells, Allison Elaine Tomlin

UNLV Theses, Dissertations, Professional Papers, and Capstones

Many studies have demonstrated clinical applications for the use of dental pulp stem cells (DPSC) for the treatment of various conditions. This has driven medical and scientific interest in the collection, isolation and banking of DPSC tissues for research into these potential therapies. Few studies to date have evaluated the viability of DPSC following long-term cryopreservation. The purpose of this study is to evaluate the effects of cryopreservation on dental pulp-derived stem cells (DPSC) viability over a period of three years. Dental pulp-derived stem cells were isolated and cultured from thirty-one healthy teeth. DPSC isolates were assessed for doubling-time and …


Design Of A Flexible Control Platform And Miniature In Vivo Robots For Laparo-Endoscopic Single-Site Surgeries, Lou P. Cubrich Dec 2016

Design Of A Flexible Control Platform And Miniature In Vivo Robots For Laparo-Endoscopic Single-Site Surgeries, Lou P. Cubrich

Department of Mechanical and Materials Engineering: Dissertations, Theses, and Student Research

Minimally-invasive laparoscopic procedures have proven efficacy for a wide range of surgical procedures as well as benefits such as reducing scarring, infection, recovery time, and post-operative pain. While the procedures have many advantages, there are significant shortcomings such as limited instrument motion and reduced dexterity. In recent years, robotic surgical technology has overcome some of these limitations and has become an effective tool for many types of surgeries. These robotic platforms typically have an increased workspace, greater dexterity, improved ergonomics, and finer control than traditional laparoscopic methods. This thesis presents the designs of both a four degree-of-freedom (DOF) and 5-DOF …


Mechanical Reliability Of Implantable Polyimide-Based Magnetic Microactuators For Biofouling Removal, Christian G. Figueroa-Espada, Qi Yang, Hyowon Lee Aug 2016

Mechanical Reliability Of Implantable Polyimide-Based Magnetic Microactuators For Biofouling Removal, Christian G. Figueroa-Espada, Qi Yang, Hyowon Lee

The Summer Undergraduate Research Fellowship (SURF) Symposium

Hydrocephalus is a neurological disorder that typically requires a long-term implantation of a shunt system to manage its symptoms. These shunt systems are notorious for their extremely high failure rate. More than 40% of all implanted shunt systems fail within the first year of implantation. On average, 85% of all hydrocephalus patients with shunt systems undergo at least two shunt-revision surgeries within 10 years of implantation. A large portion of this high failure rate can be attributed to biofouling-related obstructions and infections. Previously, we developed flexible polyimide-based magnetic microactuators to remove obstructions formed on hydrocephalus shunts. To test the long-term …


Automated Measurement Of Fracture Callus In Radiographs Using Portable Software, Stephen M. Porter, Hannah L. Dailey, Katharine A. Hollar, Karina Klein, James A. Harty, Trevor J. Lujan Jul 2016

Automated Measurement Of Fracture Callus In Radiographs Using Portable Software, Stephen M. Porter, Hannah L. Dailey, Katharine A. Hollar, Karina Klein, James A. Harty, Trevor J. Lujan

Mechanical and Biomedical Engineering Faculty Publications and Presentations

The development of software applications that assist the radiographic evaluation of fracture healing could advance clinical diagnosis and expedite the identification of effective treatment strategies. A radiographic feature regularly used as an outcome measure for basic and clinical fracture healing research is new bone growth, or fracture callus. In this study, we developed OrthoRead, a portable software application that uses image-processing algorithms to detect and measure fracture callus in plain radiographs. OrthoRead utilizes an optimal boundary tracking algorithm to semi-automatically segment the cortical surface, and a novel iterative thresholding selection algorithm to then automatically segment the fracture callus. The software …


The Development Of A Prosthetic Training Software For Upper Limb Amputees, Tyler Kayne Sullins Jun 2016

The Development Of A Prosthetic Training Software For Upper Limb Amputees, Tyler Kayne Sullins

USF Tampa Graduate Theses and Dissertations

The purpose of this study was to develop an intuitive software that aids in the field of prosthetic training and rehabilitation by creating an individualized visualization of joint angles. This software is titled “the prosthetic training software (PTS) for individualized joint angle representation”, and it enables the individualized portrayal of predicted or pre-recorded joint angles. The PTS is an intuitive program for clinicians and prosthesis users that produces an animation of a virtual avatar reflecting the user’s segment lengths and amputation for rehabilitation and training purposes.

The PTS consists of a graphical user interface (GUI) and a 3D visualization of …


Microfluidic E. Coli Detection, Kyle Pietrzyk, Scott Fukuoka, Andres Maldonado-Liu, Andy Ly Jun 2016

Microfluidic E. Coli Detection, Kyle Pietrzyk, Scott Fukuoka, Andres Maldonado-Liu, Andy Ly

Interdisciplinary Design Senior Theses

In both developed and developing countries, there is a need for a fast diagnostic system to detect pathogens within a fluid sample. In developing a microfluidic platform, which utilizes a microfluidic chip and an optical detection method, doors may be opened for new methods of determining pathogen concentration in fluid. Most biological reactions are not instantaneous. A flow-controlling mechanism with no power requirement may be implemented in the microfluidic platform. As a proof-of-concept, our device uses a microfluidic chip, smartphone, and microlens to detect E. coli concentrations in water. The detection method is based on the latex agglutination assay which …


Prosthetic Socket Cooling System, Benjamin K. Kraw, Kathy Ha, Derek Piastrelli, Cuong Lai Jun 2016

Prosthetic Socket Cooling System, Benjamin K. Kraw, Kathy Ha, Derek Piastrelli, Cuong Lai

Mechanical Engineering

A team of four senior-level undergraduate students in the Interdisciplinary Senior Project Design course in the Engineering Department of California Polytechnic State University: San Luis Obispo have worked to develop a prosthetic socket cooling system, namely for veteran Taylor Morris and exclusively for a transfemoral prosthetic socket, under the Quality of Life+ Laboratory. This cooling system will utilize the thermoelectric effect known as the Peltier effect to transmit heat generated from the residual limb to the surrounding environment by means of forced convection over small aluminum heat sinks. Two measurement devices have also been developed to, one, measure the heat …


Portable Sensory Room For The West Orange County Consortium For Special Education, Lindsey Chase, Emma Eskildsen, Alex Fox, Claire Francis, Nate Hoffman, Kaylee Keck, Sarah Sullivan Jun 2016

Portable Sensory Room For The West Orange County Consortium For Special Education, Lindsey Chase, Emma Eskildsen, Alex Fox, Claire Francis, Nate Hoffman, Kaylee Keck, Sarah Sullivan

Biomedical Engineering

This report discusses the development of a Portable Sensory Room to be used at Newland Elementary School in Huntington Beach. Newland Elementary has an exceptional Special Needs program that teaches the children with the most severe cases of autism in its school district. People with autism typically also have sensory processing disorders, which can be extremely disruptive for a child’s development and can make it difficult for a child to be able to concentrate long enough to gain necessary life skills. The idea behind a Sensory Rooms is to create a place to calm the students and to expose them …


Improvement Of Mounting Techniques For Accelerated Wear Testing Of Artificial Heart Valves, Kyle Koon, Clay Bougher, Lawrence Yang Jun 2016

Improvement Of Mounting Techniques For Accelerated Wear Testing Of Artificial Heart Valves, Kyle Koon, Clay Bougher, Lawrence Yang

Mechanical Engineering

Confidential


The Effects Of Obesity On Resultant Knee Joint Loads For Gait And Cycling, Juan Gutierrez-Franco Jun 2016

The Effects Of Obesity On Resultant Knee Joint Loads For Gait And Cycling, Juan Gutierrez-Franco

Master's Theses

Osteoarthritis (OA) is a degenerative disease of cartilage and bone tissue and the most common form of arthritis, accounting for US$ 10.5 billion in hospital charges in 2006. Obesity (OB) has been linked to increased risk of developing knee OA due to increased knee joint loads and varus-valgus misalignment. Walking is recommended as a weight-loss activity but it may increase risk of knee OA as OB gait increases knee loads. Cycling has been proposed as an alternative weight-loss measure, however, lack of studies comparing normal weight (NW) and OB subjects in cycling and gait hinder identification of exercises that may …


Agricultural Field Robotics For Plant Data Acquisition, Jeremy S. Blackford, Jared Werner, Tyler A. Troyer, Ethan Nutter May 2016

Agricultural Field Robotics For Plant Data Acquisition, Jeremy S. Blackford, Jared Werner, Tyler A. Troyer, Ethan Nutter

UCARE: Research Products

As the demand for food increases, we are presented with the challenge of producing food more efficiently. With the help of agricultural robots it will be possible to achieve greater yields by the application of seeds, fertilizers and chemicals in the most efficient way possible. With more advanced robotic systems accurate crop data can be obtained to improve farming products and techniques.

Flex-Row is a medium sized agricultural robotic platform built for autonomously traversing through rough fields during multiple crop growing stages. This platform consisting of a flexible frame with the ability to vary both width and height will initially …


Atomic Force Microscopy Based Dna Analysis, Drew Creighton May 2016

Atomic Force Microscopy Based Dna Analysis, Drew Creighton

Mechanical Engineering Undergraduate Honors Theses

This report explores dry and wet scanning of a surface and DNA pickup using an AFM, as well as fluorescent staining of DNA. Dry and wet scans of DNA were obtained using a cantilever AFM tip in tapping mode. Dry scans were found to be clearer than wet scans; however, the drying process was found to decrease the thickness of DNA 2–4 times less than its original thickness. Alternately, wet scans were found to be less clear than dry scans and introduced more noise into the images obtained. Additionally, DNA kept its initial thickness during wet scanning. DNA was capable …


Portable High Throughput Digital Microfluidics And On-Chip Bacteria Cultures, Yiyan Li May 2016

Portable High Throughput Digital Microfluidics And On-Chip Bacteria Cultures, Yiyan Li

UNLV Theses, Dissertations, Professional Papers, and Capstones

An intelligent, portable, and high throughput digital microfluidic (DMF) system is developed. Chapter 1 introduces microfluidics and DMF systems. In Chapter 2, a low-cost and high resolution capacitive-to-digital converter integrated circuit is used for droplet position detection. A field-programmable gate array FPGA is used as the integrated logic hub of the system for highly reliable and efficient control of the circuit. In this chapter a fast-fabricating PCB (printed circuit board) substrate microfluidic system is proposed. Smaller actuation threshold voltages than those previously reported are obtained. Droplets (3 µL) are actuated using 200 V, 500 Hz DC pulses. Droplet positions can …