Cuda Implementation Of A Navier-Stokes Solver On Multi-Gpu Desktop Platforms For Incompressible Flows, Julien C. Thibault, Inanc Senocak Jan 2009

Cuda Implementation Of A Navier-Stokes Solver On Multi-Gpu Desktop Platforms For Incompressible Flows, Julien C. Thibault, Inanc Senocak

Mechanical and Biomedical Engineering Faculty Publications and Presentations

Graphics processor units (GPU) that are traditionally designed for graphics rendering have emerged as massively-parallel "co-processors" to the central processing unit (CPU). Small-footprint desktop supercomputers with hundreds of cores that can deliver teraflops peak performance at the price of conventional workstations have been realized. A computational fluid dynamics (CFD) simulation capability with rapid computational turnaround time has the potential to transform engineering analysis and design optimization procedures. We describe the implementation of a Navier-Stokes solver for incompressible fluid flow using desktop platforms equipped with multi-GPUs. Specifically, NVIDIA’s Compute Unified Device Architecture (CUDA) programming model is used to implement the discretized …


Therapeutic Ultrasound Angioplasty: The Risk Of Arterial Perforation. An In Vitro Study, Mark Wylie, Garrett Mcguinness, Graham Gavin Jan 2009

Therapeutic Ultrasound Angioplasty: The Risk Of Arterial Perforation. An In Vitro Study, Mark Wylie, Garrett Mcguinness, Graham Gavin

Conference Papers

The use of therapeutic ultrasound delivered via small diameter wire waveguides may represent an emerging minimally invasive approach in the treatment of chronic total occlusions (CTOs), calcified and fibrous plaques. The distal-tip mechanical vibrations (typically 0-210 μm peak-to-peak) have been reported to debulk rigid calcified and fibrous tissues while healthy elastic arterial tissue remains largely unaffected. The risk of arterial (healthy tissue) perforation with energized waveguides is not fully understood. An ultrasonic apparatus capable of delivering a range of wire waveguide distal-tip displacements, up to 80 μm peak-to-peak (p-p), at an operational frequency of 22.5 KHz (+/- 6%) has been …


Design And Characterization Of A Shock And Vibration Mitigation Seat System, George Samaan Ladkany Jan 2009

Design And Characterization Of A Shock And Vibration Mitigation Seat System, George Samaan Ladkany

UNLV Theses, Dissertations, Professional Papers, and Capstones

Extensive research has been conducted into the development of pneumatic seatbladder systems for shock and vibration mitigation for use in current U.S military vehicle envelopes. This research expands on the previous work through an elaborate experimental characterization of four prototype air bladder seat cushion systems. The experimental characterization conducted included shock testing, continuous vibration, and internal dynamic pressure measured during the shock event.

The shock testing was conducted both at the Army Research Lab as well at UNLV. The shock testing conducted at UNLV was performed on a drop tower designed and constructed during the time of this research. The …


Stochastic Event Reconstruction Of Atmospheric Contaminant Dispersion Using Bayesian Inference, Inanc Senocak, Nicolas W. Hengartner, Margaret B. Short, W. Brent Daniel Oct 2008

Stochastic Event Reconstruction Of Atmospheric Contaminant Dispersion Using Bayesian Inference, Inanc Senocak, Nicolas W. Hengartner, Margaret B. Short, W. Brent Daniel

Mechanical and Biomedical Engineering Faculty Publications and Presentations

Environmental sensors have been deployed in various cities for early detection of contaminant releases into the atmosphere. Event reconstruction and improved dispersion modeling capabilities are needed to estimate the extent of contamination, which is required to implement effective strategies in emergency management. To this end, a stochastic event reconstruction capability that can process information from an environmental sensor network is developed. A probability model is proposed to take into account both zero and non-zero concentration measurements that can be available from a sensor network because of a sensor’s specified limit of detection. The inference is based on the Bayesian paradigm …


Parameter Estimation Of The Arterial System, James Charles Carter Ii Oct 2008

Parameter Estimation Of The Arterial System, James Charles Carter Ii

Mechanical & Aerospace Engineering Theses & Dissertations

There are a number of disorders that originate from or involve faulty operation of the cardiovascular system. Diseases such as atherosclerosis, diabetes and hypertension can have a debilitating effect on blood flow. This makes the tools for simulating the effects of such diseases on blood flow important. Measures, such as pulse wave velocity, that are generated by models of the cardiovascular system can be important indicators of cardiac health. Although physically measurable, obtaining some parameters comes with a high cost and discomfort to the patient. Models can provide an assessment of many important parameters. The purpose of this project was …


The Party’S Over: Sustaining Support Programs When The Funding Is Done, John Gardner, Pat Pyke, Cheryl Schrader, Janet M. Callahan, Amy Moll Jun 2008

The Party’S Over: Sustaining Support Programs When The Funding Is Done, John Gardner, Pat Pyke, Cheryl Schrader, Janet M. Callahan, Amy Moll

Mechanical and Biomedical Engineering Faculty Publications and Presentations

In the lifecycle of an engineering education grant, the phase where best practices are sustained and disseminated is perhaps the most crucial stage for maximizing impact. Yet this transition phase often receives the least attention as project team enthusiasm can wane, while funding tapers off, and faculty priorities are pulled in other directions. There are numerous obstacles associated with sustaining program changes, even those perceived as very valuable. Typical challenges are: What happens when the funding runs out? What grant-developed programs should be sustained by the university? Does the institution need to internally allocate resources in an annual budget large …


An Analysis Of The Performance Of Foams Used In Hurling Helmets, Keith Norris, Stephen Tiernan May 2008

An Analysis Of The Performance Of Foams Used In Hurling Helmets, Keith Norris, Stephen Tiernan

Conference Papers

Abstract Head injuries can occur in most sporting activities. The seriousness of these injuries can vary greatly depending on the sport. Many sports such as American football, cricket, baseball and hurling try to reduce this risk by designing helmets that are suitable to be worn by the players. The National Standard Authority of Ireland (NSAI) has recently made great strides in this area with the introduction of the first comprehensive standard adopted for the sport I.S. 355:2006, which sets out new testing procedures that all new helmets must meet. The Gaelic Athletic Association (GAA) has also stated its intention to …


Caffeine Model Identification For Vigilance Performance Prediction, Chun-Hui Huang Apr 2008

Caffeine Model Identification For Vigilance Performance Prediction, Chun-Hui Huang

Mechanical & Aerospace Engineering Theses & Dissertations

The pharmacodynamics and pharmacokinetics of caffeine have been well characterized. In this study, a caffeine dynamic model is developed to describe its pharmacodynamic effects on vigilance performance. Validated biomathematical models developed to address both individual and group fatigue and alertness in a non-laboratory setting represent a tremendous commercial opportunity. First, a test data set with caffeine effects isolated from circadian and homeostatic effects is created. Then a modeling approach for input and output effects is developed and different model structures for the caffeine effects are considered. Observer/Kalman filter Identification (OKID) algorithm is proposed and developed to identify the caffeine model …


Force Measurement And Evaluation For Surgical Cutting Applications: Development Of An Effective Characterisation Testbed, Dean Callaghan Mar 2008

Force Measurement And Evaluation For Surgical Cutting Applications: Development Of An Effective Characterisation Testbed, Dean Callaghan

Conference Papers

Sensorized instruments that cater for accurate measurement of the interaction forces (between biological tissue and instrument end-effector) during surgical procedures offer surgeons a greater sense of immersion during minimally invasive robotic surgery (MIRS). There is much ongoing research into force measurement/evaluation involving surgical graspers. However, comparatively little corresponding effort has been expended in the measurement and subsequent evaluation of forces between scissor blades and tissue. This paper presents the design and development of a force/strain measurement test apparatus, which will ultimately serve as an effective sensor characterisation and evaluation platform. Data acquired from the testing platform can be used to …


Investigation Of Reynolds Stresses In A 3d Idealized Urban Area Using Large Eddy Simulation, Akshay A. Gowardhan, E. R. Pardyjak, Inanc Senocak, M. J. Brown Sep 2007

Investigation Of Reynolds Stresses In A 3d Idealized Urban Area Using Large Eddy Simulation, Akshay A. Gowardhan, E. R. Pardyjak, Inanc Senocak, M. J. Brown

Mechanical and Biomedical Engineering Faculty Publications and Presentations

High resolution, large eddy simulation (LES) of neutral flow through an array of cubes has been conducted with periodic boundary conditions in lateral and longitudinal directions. In this paper, we first describe the model formulation and validate the simulation by comparing the mean flow and turbulence statistics with wind-tunnel experimental data from a cube array of buildings. The LES model is then used to investigate the physical mechanisms that lead to the low turbulent stresses that have been reported in the lower half of the urban canopy layer. To do this, the urban boundary layer is conceptually broken down into …


Fabrication Of Ankle-Foot Orthoses Using Selective Laser Sintering Technology, Allison Kinney, M. C. Faustini, Richard R. Neptune, R. H. Crawford, S. J. Stanhope Jul 2007

Fabrication Of Ankle-Foot Orthoses Using Selective Laser Sintering Technology, Allison Kinney, M. C. Faustini, Richard R. Neptune, R. H. Crawford, S. J. Stanhope

Mechanical and Aerospace Engineering Faculty Publications

Passive dynamic ankle-foot orthoses (AFOs) are often prescribed to improve gait performance for those with various neuromuscular disorders. Designs and materials used for AFOs range from simple polypropylene braces to advanced custom carbon fiber dynamic AFOs that passively store and release mechanical energy during gait. AFO designs vary in the shape and length of the foot component as well as the stiffness and length of the tibial component, depending on the desired functional outcomes. However, the current fabrication technology is not ideally suited for refined customization of AFO characteristics to optimize performance, or for rapid lowcost, high volume manufacturing and …


Development And Analysis Of A Software Package To Quantify In Vivo Polyethylene Wear After Total Hip Arthroplasty, Allison Kinney, Catherine G. Ambrose Jul 2007

Development And Analysis Of A Software Package To Quantify In Vivo Polyethylene Wear After Total Hip Arthroplasty, Allison Kinney, Catherine G. Ambrose

Mechanical and Aerospace Engineering Faculty Publications

Since the first total hip arthroplasty (THA) in 1938, THA evolved and developed into one of the major concentrations of orthopaedic research. The typical hip implant device used today incorporates a femoral and an acetabular component that serve to replicate the anatomical and mechanical functions of the natural hip joint. However, several problems exist that can effect the function of the implant device. Wear in the polyethylene liner of the acetabular component of the total hip replacement device is known as one of the major factors that affects the longevity of total hip replacement devices. Both manual and computer-aided techniques …


Lower Extremity Mechanics During Cutting Tasks In Different Shoe-Turf Combinations, Rafael Garcilazo Apr 2007

Lower Extremity Mechanics During Cutting Tasks In Different Shoe-Turf Combinations, Rafael Garcilazo

McNair Scholars Research Journal

The demands placed on the lower extremity when performing jumping and cutting maneuvers are depending, in part, on the interaction between the playing surface and the athlete's footwear. Higher demands are likely to result in increased incidence of injury, so for safety reasons it is important to quantify how the shoe-turf interface affects joint loads. The purpose of this study is to compare the forces on the lower extremity while landing and side cutting (rapid direction change at approximately 45 degrees) on artificial football turf with different styles of football cleats.


Influence Of Van Der Waals Forces On Increasing The Strength And Toughness In Dynamic Fracture Of Nanofibre Networks: A Peridynamic Approach, Florin Bobaru Ph.D. Jan 2007

Influence Of Van Der Waals Forces On Increasing The Strength And Toughness In Dynamic Fracture Of Nanofibre Networks: A Peridynamic Approach, Florin Bobaru Ph.D.

Department of Engineering Mechanics: Faculty Publications

The peridynamic method is used here to analyse the effect of van der Waals forces on the mechanical behaviour and strength and toughness properties of three-dimensional nanofibre networks under imposed stretch deformation. The peridynamic formulation allows for a natural inclusion of long-range forces (such as van der Waals forces) by considering all interactions as ‘long-range’. We use van der Waals interactions only between different fibres and do not need to model individual atoms. Fracture is introduced at the microstructural (peridynamic bond) level for the microelastic type bonds, while van der Waals bonds can reform at any time. We conduct statistical …


Indentation Fracture Of Bovine Cortical Bone: Acoustic Emission Technique, Ashkan Safari, Ger Reilly, Brendan Mccormack Jan 2006

Indentation Fracture Of Bovine Cortical Bone: Acoustic Emission Technique, Ashkan Safari, Ger Reilly, Brendan Mccormack

Conference Papers

Indentation cutting may result in microcracking and main crack growth which was previously reported. In this study, we recorded the AE signals produced by cracking processes during cutting on cortical bone, measuring the cutting force and correlating between load-displacement curves and AE activities.


A Numerical Acoustic Fluid-Structure Simulation Of Therapeutic Ultrasound Angioplasty, Graham Gavin, Finbar Dolan, M.S J. Hashmi, Garrett Mcguinness Jan 2006

A Numerical Acoustic Fluid-Structure Simulation Of Therapeutic Ultrasound Angioplasty, Graham Gavin, Finbar Dolan, M.S J. Hashmi, Garrett Mcguinness

Conference Papers

INTRODUCTION Therapeutic ultrasound angioplasty is the delivery of high amplitude ultrasonic displacements to the distal-tip of small diameter wire waveguides with the goal of disrupting atherosclerotic plaques. This is a minimally invasive procedure that may have potential' in the treatment of complicated chronic total occlusions. The disruption of plaque is due to direct contact ablation and also cavitation, pressure waves and acoustic streaming in the fluid surrounding the vibrating waveguide distal-tip [1]. Cavitation appears to play a major role and some authors have suggested that plaque ablation is only evident above the cavitation threshold [2]. Makin and Everbach [3] performed …


A Numerical Acoustic Fluid-Structure Model Of A Therapeutic Ultrasound Angioplasty Device, Graham Gavin, M.S. J. Hashmi, Finbar Dolan, Garrett Mcguinness Jan 2006

A Numerical Acoustic Fluid-Structure Model Of A Therapeutic Ultrasound Angioplasty Device, Graham Gavin, M.S. J. Hashmi, Finbar Dolan, Garrett Mcguinness

Conference Papers

Ultrasonic angioplasty involves the use of ultrasonic vibrations delivered to the distal-tip of small diameter wire waveguides and is an emerging technology the may have potential use in the treatment of complicated atherosclerotic plaques during cardiovascular surgery. Complicated plaques, including chronic total occlusions and calcified lesions, seriously reduce success rates during standard intervention involving guidewire access, followed by balloon dilation or stent delivery. The large amplitude (0-150 μm) wire waveguide distal-tip displacements in the low-frequency ultrasonic (18-45 kHz) range have been shown to disrupt plaque material by direct contact ablation and cavitation, acoustic streaming and pressure wave components in adjacent …


Analysis Of Indentation Loading Of Cortical Bone Using Acoustic Emission Techniques, Ashkan Safari, Ger Reilly, Brendan Mccormack Dec 2005

Analysis Of Indentation Loading Of Cortical Bone Using Acoustic Emission Techniques, Ashkan Safari, Ger Reilly, Brendan Mccormack

Conference Papers

In this study, we recorded the number of Acoustic emission (AE) hits and related AE energy during indentation fracture of cortical bone using a PAC PCI-2 card and pico sensor. A threshold value of 43dB was used to filter premature trigger due to background noise. Registered AE hits had more than one count (threshold crossing). Amplifier gain was set at 40dB with a (0.1-1) MHz band pass filter. 8mm cubes of cortical bones were indented in the longitudinal direction at constant crosshead speed of 1 mm min-1 using a large 2D, 50˚ wedge indenter. We hypothesised that signals occurring as …


Experimental And Numerical Investigation Of Therapeutic Ultrasound Angioplasty, Graham Gavin, M.S. J. Hashmi, Garrett B. Mcguinness Jan 2005

Experimental And Numerical Investigation Of Therapeutic Ultrasound Angioplasty, Graham Gavin, M.S. J. Hashmi, Garrett B. Mcguinness

Other resources

Therapeutic ultrasound angioplasty is an emerging minimally invasive cardiovascular surgical procedure that involves the delivery of ultrasonic displacements to the distal-tip of small diameter wire waveguides. The ultrasonic distal-tip displacements affect atherosclerotic plaque and thrombus by direct contact ablation, pressure wave components and cavitation, in addition to an acoustic streaming event around the distal-tip. This study uses experimental and numerical methods to investigate ultrasonic displacements in wire waveguides and the effect the distal-tip displacements have on the surrounding fluid. An experimental therapeutic ultrasound wire waveguide apparatus is described that delivers displacements to the distal-tip of 1.0 mm and tapered 0.35 …


Development And Performance Characteristics Of An Ultrasound Angioplasty Device, Graham Gavin, Garrett Mcguinness, Finbar Dolan, M.S. J. Hashmi Jan 2005

Development And Performance Characteristics Of An Ultrasound Angioplasty Device, Graham Gavin, Garrett Mcguinness, Finbar Dolan, M.S. J. Hashmi

Conference Papers

INTRODUCTION The effect of atherosclerosis is well documented and many procedures such as balloon angioplasty and stentimplantation have been developed to reopen occluded arteries. However, there are considerable differences in the material properties of various atherosclerotic lesions as they develop. Many authors have suggested that rigid calcified plaques may require specific procedures that target this rigid material through de-bulking or complete removal (Salunke et al, 1997). Ultrasound angioplasty is the delivery of high power low frequency ultrasound via a wire waveguide to the lesion location. This results in distal tip wire displacements of up to 100um peak-to-peak (p-p) at frequencies …


Distal Placement Of An End-To-Side Bypass Graft Anastomosis A 3-D Computational Study, John Robert Di Cicco Oct 2004

Distal Placement Of An End-To-Side Bypass Graft Anastomosis A 3-D Computational Study, John Robert Di Cicco

Mechanical & Aerospace Engineering Theses & Dissertations

A three-dimensional computational fluid dynamics study of blood flow through stenotic arteries has been conducted. Flow phenomena, such as separation regions and turbulence, can be found distal to an arterial stenosis. Frequently, a bypass graft using an end-to-side technique is attached to a stenotic artery to restore adequate blood flow. However, a significant percentage of these grafts fail after thirty postoperative days due to intimal hyperplasia development around the distal anastomosis. Moreover, aberrant wall shear rates have been implicated as a factor in the development of intimal hyperplasia. Thus, the present study examines whether placement of the distal end of …


Pressure Distribution Around Spherical Distal Ball-Tip In Ultrasound Angioplasty, Graham Gavin, Garrett B. Mcguinness, Finbar Dolan, M.S. J. Hashmi Jul 2004

Pressure Distribution Around Spherical Distal Ball-Tip In Ultrasound Angioplasty, Graham Gavin, Garrett B. Mcguinness, Finbar Dolan, M.S. J. Hashmi

Conference Papers

INTRODUCTION Ultrasound Angioplasty has been shown to be effective in the removal and re-canalising of blockages in arteries (Siegel RJ, 1993). By delivering therapeutic ultrasound to the blockage, via a wire waveguide to a ball-tip, the lesion or thrombus is affected by pressure waves, micro streaming, cavitation and direct contact with the oscillating ball-tip. Most work to date has concentrated on a spherical ball-tip geometry at the distal end of the wire waveguide (Steffen, 1994 and Rosenschein, 1996). Tip displacements usually lie between 10 - 100m (peak-to peak) and ball tip diameters between 1 - 2mm (Atar, 1999 and Yock, …


Field Effect Control Of Electrokinetic Transport Phenomena In Nanofluidics, Song Xue Jul 2004

Field Effect Control Of Electrokinetic Transport Phenomena In Nanofluidics, Song Xue

Mechanical & Aerospace Engineering Theses & Dissertations

Naturally nanofluidics has applications demanding the samples to be handled in exceedingly small quantities due to the small size of the fluidic channels in nanofluidic devices, such as characterization of single biomolecules. Fluids confined in channels of nanometer characteristic dimensions exhibit physical behaviors not observed in large conduits. Charge properties of the nanochannel wall in contact with an aqueous solution play essential roles in the involved electrokinetic transport phenomena occurring in nanofluidic devices. In addition to tuning the charge properties of the nanofluidic channel wall by adjusting the solution properties such as pH and background salt concentration, field effect transistor …


Microscale Investigation Of Thermo-Fluid Transport In The Transition Fil, Region Of An Evaporating Capillary Meniscus Using A Microgravity Environment, Kenneth D. Kihm, Jeffrey S. Allen, Kevin P. Hallinan, David M. Pratt Jan 2004

Microscale Investigation Of Thermo-Fluid Transport In The Transition Fil, Region Of An Evaporating Capillary Meniscus Using A Microgravity Environment, Kenneth D. Kihm, Jeffrey S. Allen, Kevin P. Hallinan, David M. Pratt

Mechanical and Aerospace Engineering Faculty Publications

In order to enhance the fundamental understanding of thin film evaporation and thereby improve the critical design concept for two-phase heat transfer devices, microscale heat and mass transport is to be investigated for the transition film region using state-of-the-art optical diagnostic techniques. By utilizing a microgravity environment, the length scales of the transition film region can be extended sufficiently, from submicron to micron, to probe and measure the microscale transport fields which are affected by intermolecular forces. Extension of the thin film dimensions under microgravity will be achieved by using a conical evaporator made of a thin silicon substrate under …


Comment On "Quadriceps Protects The Anterior Cruciate Ligament", Antonie J. Van Den Bogert Sep 2002

Comment On "Quadriceps Protects The Anterior Cruciate Ligament", Antonie J. Van Den Bogert

Mechanical Engineering Faculty Publications

No abstract provided.


Multifield Spectral Analysis Of Human Respiratory Sounds, John William Ray Jr. Apr 1999

Multifield Spectral Analysis Of Human Respiratory Sounds, John William Ray Jr.

Doctoral Dissertations

Computer analysis of human respiratory sounds (phonopneumography) has been attempted since the 1960s with poor results. Steady research efforts by numerous researchers have failed to yield a practical diagnostic tool to replace the physician and the stethoscope. This has been the result of the high degree of variability in proposed analysis parameters from subject to subject.

The purpose of this research is to examine a new approach to phonopneumography by comparing multiple lung fields of the same subject for the same breath in order to develop the diagnostic parameters. This approach has the advantage of allowing the subject to provide …


The Effects Of Machining On Structure And Tribological Properties Of Ultra High Molecular Weight Polyethylene For Artificial Joint Prostheses, Jinshan Song Jan 1997

The Effects Of Machining On Structure And Tribological Properties Of Ultra High Molecular Weight Polyethylene For Artificial Joint Prostheses, Jinshan Song

Masters Theses

Understanding the effect of machining on the structure and property of subsurface layer of ultra high molecular weight polyethylene (UHMWPE) can significantly facilitate the increase in longevity of artificial joints. This study was performed to investigate the machining effects on the polymeric structure and tribological properties. Machining parameters include cutting speed, tool feed rate and depth of cut. Temperature rise was studied during machining to assess the extent of thermal degradation due to machining. Polymeric structure of the semicrystalline polymer was characterized using differential scanning calorimetry (DSC) in terms of melting enthalpy, crystallinity and melting temperature. Surface texture and hardness …


Investigation Of Blood Pressure Measurement Using A Hydraulic Occlusive Cuff, Kusha R. Bhattarai May 1982

Investigation Of Blood Pressure Measurement Using A Hydraulic Occlusive Cuff, Kusha R. Bhattarai

Dissertations and Theses

This thesis presents an improved oscillotonometric system for the measurement of human blood pressure. The study included:

1. The design of a hydraulic occlusive cuff,

2. The investigation of the wave forms taken from the blood pressure measurements, and

3. The design of a mechanism for the simulation of human blood pressure pulse.

In this study, an experimental system consisting of a rigid shell occlusive cuff, a constant volume displacement pump, a transducer, and a chart recorder was designed and used for data collection.


Milking Machine Efficiency And Shed Husbandry Practices, G R. Olney Jan 1965

Milking Machine Efficiency And Shed Husbandry Practices, G R. Olney

Journal of the Department of Agriculture, Western Australia, Series 4

MILKING machine efficiency on dairy farms in the Bridgetown, Greenbushes, Balingup, Boyup Brook and Nannup areas was the subject of a recent testing survey.

During the survey 106 machines were tested and the results assessed statistically to gauge the general level of machine efficiency in these districts.