Full-Text Articles in Biomedical Devices and Instrumentation

Design And Development Of A Stair Ascension Assistive Device For Transfemoral Amputees, Casey Michael Barbarino Jun 2013

Design And Development Of A Stair Ascension Assistive Device For Transfemoral Amputees, Casey Michael Barbarino

Master's Theses

Transfemoral amputees around the world experience increased difficulty in climbing stairs due to lack of muscle, balance, and other factors. The loss of a lower limb greatly diminishes the amount of natural force generation provided that is necessary to propel oneself up stairs. This study investigated possible solutions to the problem of stair ascension for transfemoral amputees by the means of designing and developing an externally attachable device to a prosthesis. The number of amputations from military service has greatly increased since 2008, which shows there is a clear need for assistive devices (Wenke, Krueger, & Ficke, 2012). With the …


Modeling The Zimmer Fitmore And Ml Taper Implantation, Tyler Kazuo Franklin May 2013

Modeling The Zimmer Fitmore And Ml Taper Implantation, Tyler Kazuo Franklin

Master's Theses

With more young adults requiring total hip

arthroplasties the need for bone saving implants becomes

more important. The Zimmer Fitmore is a new bone saving

implant that utilizes an implantation technique that

reduces the damage to the muscle tissue allowing for

patients to have a short recovery time as well as a new

design that allows it to rest on the medial cortex. There

has been anecdotal evidence that this device leads to early

revision within six months of implantation due to failures

occurring in the medial cortex. The main goal of this

study was to computationally model the Zimmer …


Novel Approach To Junctional Bleeding: Tourniquet Device Proposal For Battlefield Hemorrhage Control, Kyle W. Cabaniss Mar 2013

Novel Approach To Junctional Bleeding: Tourniquet Device Proposal For Battlefield Hemorrhage Control, Kyle W. Cabaniss

Master's Theses

This study investigated possible solutions to the current wartime problem of junctional hemorrhaging, or massive traumatic hemorrhaging in non-tourinquetable areas such as the neck, groin, or armpit. Junctional hemorrhaging has been identified as a major contributor to potentially survivable deaths seen on the battlefield today and therefore is a priority for the U.S. armed and coalition forces (Kragh et al., 2011a; Bozeman, 2011). Common tourniquets today are standard issue and carried by soldiers in the military, but are limited to distal extremity trauma. As the battlefield has changes however, trauma has transformed from commonly seen gunshot wounds to more extreme …


Automated Point-Of-Care Image Processing Methodology For The Diagnosis Of Malaria, Michael B. Jorgensen Jan 2013

Automated Point-Of-Care Image Processing Methodology For The Diagnosis Of Malaria, Michael B. Jorgensen

Master's Theses

Malaria has profoundly influenced human history for over four thousand years and despite numerous attempts at eradication, the prevention, diagnosis, and treatment of malaria have been largely ineffective. More than five hundred million people are affected by malaria every year resulting in over one million deaths. Drug resistance development by the parasite has diminished the effectiveness of numerous treatment options due, in part, to overtreatment of negative patients based on insufficient clinical algorithms and diagnostic methods. The goal of this research was to develop an image analysis algorithm to diagnose malaria with a high degree of sensitivity and specificity in …


Measuring Impedance Of Tissues Using A Microfabricated Microelectrode Array, Ashwini Bhat Dec 2012

Measuring Impedance Of Tissues Using A Microfabricated Microelectrode Array, Ashwini Bhat

Master's Theses

MEASURING IMPEDANCE OF TISSUES USING A MICROFABRICATED MICROELECTRODE ARRAY By Ashwini Bhat

This thesis looks at the possibility of using impedance spectroscopy for differentiating tissue, using a microelectrode array (MEA). The thesis first discusses the background and the motivation for this thesis. It covers the certain basic concepts of the human skin starting from the top epidermis layer all the way to the deep dermis layers of the skin. Then it discusses different types of skin cancer and how they occur, in humans. It also discusses various microfabrication techniques such as oxidation, wet etching, sputtering and photolithography for the creation …


Development Of Simulation Platform For Oropharyngeal Airway Placement And Design Evaluation Of The Bardo Airway, Lewis On Hang Lee Dec 2012

Development Of Simulation Platform For Oropharyngeal Airway Placement And Design Evaluation Of The Bardo Airway, Lewis On Hang Lee

Master's Theses

Off-label use of traditional Oropharyngeal Airway (OPA) as a bite-block, and the subsequential procedure of force exertion of the device by physician has caused many cases of patient’s teeth damage and monetary loss, as the patient’s incisors were damaged while clenching on the OPA during an adverse scenario called “Emergency Clenching”. To remedy this harmful situation, Bardo OPA was developed by Dr. Theodore Burdumy. The Bardo airway has unique design to transfer the clenching force from incisor to the molar. However, the Bardo OPA is one-sized, and cannot fit most of the patients like the commonly-used OPAs, such as the …


Hydrodynamic Focused Passive Separation Under Continuous Flow In A Microfluidic Chip, Jad Kanbar Sep 2012

Hydrodynamic Focused Passive Separation Under Continuous Flow In A Microfluidic Chip, Jad Kanbar

Master's Theses

A continuous flow, passive separation device was designed using an equivalent circuit to create variable flow rates for hydrodynamic focusing to drain channels and collection outlets. By varying the diameter of the sample inlet connection into the reservoir, the particle position was influenced significantly, which enabled desired separations. Additionally it was noted that the relative, horizontal position of the inlet also had a significant influence on particle position within the device. A dimensionless number, the Characteristic Sample Inlet, was developed to relate geometric properties of the inlet reservoir to downstream particle distribution. It was found that a 2:1 ratio between …


Responding To Dangerous Accidents Among The Elderly: A Fall Detection Device With Zigbee-Based Positioning, Michael R. Putnam Sep 2012

Responding To Dangerous Accidents Among The Elderly: A Fall Detection Device With Zigbee-Based Positioning, Michael R. Putnam

Master's Theses

The following paper describes a fall detection and activity monitoring system with position detection based on Zigbee transceivers.The main objective is to reduce the time taken for emergency personnel to respond to falls among the elderly. Especially when the victim is unconscious or delirious, position tracking reduces location determination time within a busy hospital or nursing home environment and facilitates immediate treatment. Reduced response times correlate to decreased morbidity and mortality rates. Background is provided on the major wireless network advances currently deployed in a healthcare setting for asset and personnel tracking, etiology of falls, and several methods of detecting …


Development And Characterization Of An In-House Custom Bioreactor For The Cultivation Of A Tissue Engineered Blood-Brain Barrier, Amin Hadi Mirzaaghaeian Jul 2012

Development And Characterization Of An In-House Custom Bioreactor For The Cultivation Of A Tissue Engineered Blood-Brain Barrier, Amin Hadi Mirzaaghaeian

Master's Theses

The development of treatments for neurological disorders such as Alzheimer’s and Parkinson’s disease begins by understanding what these diseases affect and the consequences of further manifestation. One particular region where these diseases can produce substantial problems is the blood-brain barrier (BBB). The BBB is the selective diffusion barrier between the circulating blood and the brain. The barrier’s main function is to maintain CNS homeostasis and protect the brain from the extracellular environment. The progression of BBB research has advanced to the point where many have modeled the BBB in vitro with aims of further characterizing and testing the barrier. Particularly, …


A Kinetic Study Of Anti-Vegf-A Polyclonal Antibodies And Anti-Vegf-A Ssdna Aptamers, Heather A. Hedeen Jun 2012

A Kinetic Study Of Anti-Vegf-A Polyclonal Antibodies And Anti-Vegf-A Ssdna Aptamers, Heather A. Hedeen

Master's Theses

A new detection reagent that could possibly augment or replace antibodies research and diagnosis methods are aptamers. Aptamers are ssDNA, RNA or polypeptide constructs that function like active antibodies. Antibodies and aptamers both specifically bind to selected target molecules, and as such they enable the detection or targeting of the presence or absence of a specific antigen.

In order to ensure that ssDNA aptamers perform similarly to antibodies, anti-VEGF-A polyclonal antibody and anti-VEGF-A ssDNA aptamer were evaluated against vascular endothelial growth factor A (VEGF-A) using Surface Plasmon Resonance (SPR). It was hypothesized that the anti-VEGF-A aptamer had the same, if …


Impedance Sensing Of N2a And Astrocytes As Grounds For A Central Nervous System Cancer Diagnostic Device, Fraser Traves Smith Grove Jun 2012

Impedance Sensing Of N2a And Astrocytes As Grounds For A Central Nervous System Cancer Diagnostic Device, Fraser Traves Smith Grove

Master's Theses

This thesis utilizes previously described manufacturing and design techniques for the creation of a PDMS-glass bonded microfluidic device, capable of electrochemical impedance spectroscopy (EIS). EIS has been used across various fields of research for different diagnostic needs. The major aim of this thesis was to capture cancerous and non-cancerous cells between micron sized electrodes within a microfluidic path, and to complete analysis on the measured impedances recorded from the two differing cell types. Two distinct ranges of impedance frequency were analyzed – the α dispersion range, which quantifies the impedance of the membranes of the cells of interest, and the …


A Comprehensive Methodology For Assessing Biomechanical Risks Associated With Hand Tool Use: Applied To Laparoscopic Surgical Instruments, Drew R. Seils May 2012

A Comprehensive Methodology For Assessing Biomechanical Risks Associated With Hand Tool Use: Applied To Laparoscopic Surgical Instruments, Drew R. Seils

Master's Theses

Biomechanical risk factors are physical stressors that act on the neuromuscular structures of the human body and are present in all occupational settings. Repetition and intensity of tasks performed can magnify the effects of the biomechanical risks that a worker is exposed to.

After reviewing the current literature on ergonomics in laparoscopic surgery it was clear that a comprehensive approach to quantitatively reporting on the biomechanical risk factors associated with surgical hand tools had never been performed. Utilizing an opto-electronic motion capture system meant the exact surgeon posture was recorded during simulated surgical tasks. Electromyography was used to evaluate muscle …


Development Of A Standardized Method For Comparing Biomechanical Properties Of Various Sternal Closure Techniques, Ramzi P. Hawit Mar 2012

Development Of A Standardized Method For Comparing Biomechanical Properties Of Various Sternal Closure Techniques, Ramzi P. Hawit

Master's Theses

Background:

33.6% of all deaths in America are caused by cardiovascular disease. An estimated 82.6 million adults (>1 in 3) in America have some form of cardiovascular disease. There were over 400,000 bypass surgeries requiring open-heart surgery. Sternal dehiscence is associated with a morbidity rate of over 47% if mediastinitis supervenes. A rigid closure is required to avoid healing complications, and wire, plates, and bands are all used in an attempt to make a better closure. The purpose of this study it to compare multiple closures and validate a new testing method.

Methods:

Polyurethane foam blocks will be used, …


Dc Dielectrophoretic Assisted Anti-Fouling Filtration System, Nathan M. Cohen Mar 2012

Dc Dielectrophoretic Assisted Anti-Fouling Filtration System, Nathan M. Cohen

Master's Theses

Filtration processes, whether on the microfluidic, clinical treatment systems, or industrial scale (e.g., point-of-care diagnostics, dialysis, and biopharmaceutical manufacturing, respectively), are often inseparable from membrane clogging (fouling). As a consequence, most, if not all, filtration systems require frequent maintenance to maintain functionality and efficiency. The thesis of this project hypothesizes that Dielectrophoresis can be combined with standard filtration to reduce filter fouling, extending membrane life, and enabling continuous operation. This project investigates a method to reduce fouling, add specificity and efficiency, and decrease the cost and challenge of filtration based biofluid separations.

To substantiate this thesis, we designed, fabricated, and …


Second Generation Data-Logging System For Long-Duration Field Measurement Of Vibration Exposure And Grip Force, Robert H. Knapp Iii Jan 2012

Second Generation Data-Logging System For Long-Duration Field Measurement Of Vibration Exposure And Grip Force, Robert H. Knapp Iii

Master's Theses

Millions of United States workers are exposed to vibration at their job, whether it is from a power tool that causes hand and arm vibration or from heavy machinery. These vibrations are known to result in physical disorders such as Hand-Arm Vibration Syndrome, which can be debilitating to the point where workers can no longer do their job effectively. Research groups have taken an interest in finding what vibration characteristics are most harmful and choose to record vibration information using data-logging devices. Often, many devices, whether they are commercial or custom-built devices, use frequency weightings and full day estimations to …


Impedance-Based Detection Of Tissue Using A Multi-Electrode Device, Shane Killian Fleshman Dec 2011

Impedance-Based Detection Of Tissue Using A Multi-Electrode Device, Shane Killian Fleshman

Master's Theses

Melanoma skin cancer is the abnormal growth of the melanocytes – the pigmented cells located in the epidermis. The current gold standard diagnostic technique for determining whether a lesion is cancerous involves subjectively examining suspicious lesions and performing an invasive biopsy to confirm melanoma. This method may neglect some lesions or cause scarring from biopsies that turn out to be benign. Thus, impedance-based detection using a multi-electrode device was investigated as a noninvasive technique to diagnose melanoma skin cancer. The multi-electrode device was designed with 8 equally spaced Ag/AgCl electrodes surrounding one central electrode at a 5 mm radius. The …


Ros-Drill Automation: Visual Feedback Control And Rotational Motion Tracking, Jhon F. Diaz Aug 2011

Ros-Drill Automation: Visual Feedback Control And Rotational Motion Tracking, Jhon F. Diaz

Master's Theses

ICSI (intra-cytoplasmic sperm injection) has attracted research interest from both biological and engineering groups. The technology is constantly evolving to perform this procedure with precision and speed. One such development is the contribution of this thesis. We focus on a relatively recent procedure called Ros-Drill© (rotationally oscillating drill), of which the early versions have already been effectively utilized for the mice. In the first part, we present a procedure to automate a critical part of the operation: initiation of the rotational oscillation, Visual feedback is used to track the pipette tip. Predetermined species-specific penetration depth is successfully utilized …


A Pmma Conductivity Pretreatment Microfluidics Device For The Optimization Of Electrokinetic Manipulations, Cameron Paul Purcell Jun 2011

A Pmma Conductivity Pretreatment Microfluidics Device For The Optimization Of Electrokinetic Manipulations, Cameron Paul Purcell

Master's Theses

This project encompasses the design and development of a pretreatment microfluidic device for samples of physiological conductivity, namely a saline solution. The conductivity was reduced through the combination of dilution and ion removal using electric fields to enable downstream electro kinetic manipulations. The two major parts of this project include (1) designing a pretreatment protocol to reduce the conductivity of the sample solution to an acceptable level and (2) designing /fabricating a microchip that will effectively allow aim (1) to be performed on chip.

This project is one of the first to observe the effects of an electric field, used …


Development Of An Open Source Prosthetic Hand Platform, Scott James Garrett Jun 2011

Development Of An Open Source Prosthetic Hand Platform, Scott James Garrett

Master's Theses

Development of an Open Source Prosthetic Hand Platform

Scott Garrett

In the field of upper extremity prosthetic devices, advancements in technology drive the design of products which are becoming capable of restoring the lost functions of the native hand. While several dexterous devices have been developed to serve this purpose, they remain prohibitively expensive and thus are not a viable option for many upper extremity amputees. To address this problem a prosthetic hand platform was developed utilizing the open source Arduino microcontroller and off-the-shelf electrical components. Using these resources, a novel finger actuation mechanism was developed to show how …


Noninvasive Assessment Of Joint Motion Over Long Durations: System Evaluation And Data Analysis Methods, Maria J. Qadri May 2011

Noninvasive Assessment Of Joint Motion Over Long Durations: System Evaluation And Data Analysis Methods, Maria J. Qadri

Master's Theses

The development, progression, and treatment of degenerative musculoskeletal diseases, such as carpal tunnel and shoulder impingement syndromes, may be better characterized when joint motions are assessed over long durations outside clinical, laboratory, or rehabilitation settings that involve standardized assessment, exercise protocols, and/or regimented movements. Assessment methods for human movement capture beyond laboratory or clinical experiments are typically limited to short capture times of less than one hour. Noninvasive, long-duration measurements of joint motion in occupational settings provides more insight into movement patterns and quantitative assessments regarding joint usage, which lead to a better understanding of the cumulative effects associated with …


A Comparative Study Of Total Hemoglobin Measurement Technology: Noninvasive Pulse Co-Oximetry And Conventional Methods, Jared S. Ruckman May 2011

A Comparative Study Of Total Hemoglobin Measurement Technology: Noninvasive Pulse Co-Oximetry And Conventional Methods, Jared S. Ruckman

Master's Theses

Hemoglobin can be measured on a variety of devices using different principles of operation. Noninvasive pulse CO-oximetry represents the latest development in hemoglobin measuring technology. The technology uses principles similar to pulse oximetry to measure total hemoglobin, oxyhemoglobin, reduced oxyhemoglobin, carboxyhemoglobin and methemoglobin. Similar to the introduction of pulse oximetry to the medical field, pulse CO-oximetry has been met with skepticism. Since the technology is noninvasive and provides continuous monitoring in comparison to invasive and discrete techniques used in other methods, CO-oximetry purportedly provides an advantage in patient care. The purpose of this research is threefold: (a) to review the …


Design Of A Pragmatic Test Lab For Evaluating And Testing Wireless Medical Devices For Deployment On An Integrated It Wireless Network, Allie Paquette May 2011

Design Of A Pragmatic Test Lab For Evaluating And Testing Wireless Medical Devices For Deployment On An Integrated It Wireless Network, Allie Paquette

Master's Theses

In today’s healthcare environment, networking of medical devices is becoming more and more prevalent. There is an increasing need for mobile technology to meet clinical needs. Wireless communication is essential for allowing medical devices to be able to move with the patient, while continuing to record and communicate patient data. A traditional example is telemetry monitoring, but other examples of wireless utilization include sending ECG test results to the EMR or remotely updating the drug library on numerous IV pumps. Each wireless application has varying demands on the connectivity infrastructure and will share radio frequency (RF) spectrum resources with a …


Universal Engineering Programmer – An In-House Development Tool For Developing And Testing Implantable Medical Devices In St. Jude Medical, Khoa Tat Do Mar 2011

Universal Engineering Programmer – An In-House Development Tool For Developing And Testing Implantable Medical Devices In St. Jude Medical, Khoa Tat Do

Master's Theses

During development and testing of the functionality of the pacemaker and defibrillator device, engineers in the St. Jude Medical Cardiac Rhythm Management Division use an in-house development tool called Universal Engineering Programmer (UEP) to ensure the device functions as expected, before it can be used to test on an animal or a human during the implantation process.  In addition, some applications of UEP are incorporated into the official releases of the device product.  UEP has been developed and used by engineers across departments in the St. Jude Medical Cardiac Rhythm Management Division (CRMD).  This thesis covers the flexible and reusable …


Sar Map Of Gel Phantom In A 64mhz Mri Birdcage By Fiber-Optic Thermometry And Fdtd Simulation, Chirag Mukesh Patel Feb 2011

Sar Map Of Gel Phantom In A 64mhz Mri Birdcage By Fiber-Optic Thermometry And Fdtd Simulation, Chirag Mukesh Patel

Master's Theses

As implantable medical devices are being used more often to treat medical problems for which pharmaceuticals don’t suffice, it is important to understand their interactions with commonly used medical modalities. The interactions between medical implants and Magnetic Resonance Imaging machines have proven to be a risk for patients with implants.

Implanted medical devices with elongated metallic components can create harmful levels of local heating in a Magnetic Resonance Imaging (MRI) environment [1]. The heating of a biological medium under MRI is monitored via the Specific Absorption Rate (SAR). SAR, defined as power absorbed per unit mass (W/kg), can be calculated …


Laser Etched Pmma Microfluidic Chip Design And Manufacture With Applications In Capillary Zone Electrophoresis, Evan Allen Barbre Feb 2011

Laser Etched Pmma Microfluidic Chip Design And Manufacture With Applications In Capillary Zone Electrophoresis, Evan Allen Barbre

Master's Theses

This thesis encompasses a feasibility study of using low-cost materials to manufacture microfluidic chips that can perform the same functions as chips manufactured using traditional methods within an acceptable range of efficiency of chips created with more exotic methods and materials. The major parts of the project are the selection and characterization of the fabrication methods for creating the channels for fluid flow, the methods for sealing the channels to create a usable chip and the electrophoretic separations of carboxylated microspheres of different potentials. In this work we seek to answer the question if laser-etched PMMA microfluidic chips are comparable …


Multi-Frequency Processing For Lumen Enhancement With Wideband Intravascular Ultrasound, Rory A. Carrillo Sep 2010

Multi-Frequency Processing For Lumen Enhancement With Wideband Intravascular Ultrasound, Rory A. Carrillo

Master's Theses

The application of high frequency ultrasound is the key to higher resolution intravascular ultrasound (IVUS) images. The need to further improve the IVUS spatial resolution may drive the transducer center frequency even higher than the current 40 MHz range. However, increasing the center frequency may be challenging as it leads to stronger scattering echoes from blood. The high level of blood scattering echoes may obscure the arterial lumen and make image interpretation difficult. Blood backscatter levels increase with transmission center frequency at a much greater rate compared to arterial tissue. These different frequency dependencies provide a potential method to distinguish …


St. Jude Medical: An Object-Oriented Software Architecture For Embedded And Real-Time Medical Devices, Atila Amiri Aug 2010

St. Jude Medical: An Object-Oriented Software Architecture For Embedded And Real-Time Medical Devices, Atila Amiri

Master's Theses

Medical devices used for surgical or therapeutic purposes require a high degree of safety and effectiveness. Software is critical component of many such medical devices. The software architecture of a system defines organizational structure and the runtime characteristic of the application used to control the operation of the system and provides a set of frameworks that are used to develop that. As such, the design of software architecture is a critical element in achieving the intended functionality, performance, and safety requirements of a medical device. This architecture uses object-oriented design techniques, which model the underlying system as a set of …


St. Jude Medical: Enhanced Mics (Emics), Devanshi Shah Aug 2010

St. Jude Medical: Enhanced Mics (Emics), Devanshi Shah

Master's Theses

Heart disease is one of the most prevalent diseases in the world. The survival chances for patients with ventricular fibrillation/ventricular tachycardia reduces significantly as time passes without treatment and even after getting timely treatment recurring episode are common. These patients can benefit from an Implantable Cardioverter Defibrillator (ICD) which can monitor heart rhythm and provide immediate treatment. Due to the ever changing physical conditions and disease progression, the ICD needs to collect diagnostic data as well as support programming by the physician. The ICD uses inductive telemetry and radio-frequency telemetry for the communication with the external devices such as a …


Implementation Of Physiologic Pressure Conditions In A Blood Vessel Mimic Bioreactor System, Kevin Mark Okarski Jul 2010

Implementation Of Physiologic Pressure Conditions In A Blood Vessel Mimic Bioreactor System, Kevin Mark Okarski

Master's Theses

ABSTRACT

Implementation of Physiologic Pressure Conditions in a Blood Vessel Mimic Bioreactor System

Kevin Mark Okarski

Tissue engineering has traditionally been pursued as a therapeutic science intended for restoring or replacing diseased or damaged biologic tissues or organs. Cal Poly’s Blood Vessel Mimic Laboratory is developing a novel application of tissue engineering as a tool for the preclinical evaluation of intravascular devices. The blood vessel mimic (BVM) system has been previously used to assess the tissue response to deployed stents, but under non-physiologic conditions. Since then, efforts have been made to improve the vessel and bioreactor’s ability to emulate in …


Effects Of Reamer-Femoral Component Offset On Cement Mantle Penetration In Hip Resurfacing Arthroplasty, Mark Lloyd Paulick May 2010

Effects Of Reamer-Femoral Component Offset On Cement Mantle Penetration In Hip Resurfacing Arthroplasty, Mark Lloyd Paulick

Master's Theses

Hip resurfacing arthroplasty has changed the treatment of end stage arthritis without severe deformity for young, active adults. Presently, there are varying clinical approaches to implant design selection and cementation techniques. The purpose of this project is to determine what amount of reamer-femoral component offset allows for the best cement penetration into the femoral head.

Rapid prototyped femoral component models were produced with reamer femoral component offsets of 0.0 mm, 0.5 mm, and 1.0 mm. After implantation onto models of reamed femoral heads made from high-density open-cell reticulated carbon foam, cement penetration was assessed from cross-sections of the foam-implant unit. …