Open Access. Powered by Scholars. Published by Universities.®

Biochemical and Biomolecular Engineering

Institution
Keyword
Publication Year
Publication
Publication Type

Articles 91 - 120 of 147

Full-Text Articles in Biomedical Devices and Instrumentation

The Effect Of Adding Organic Polymers To Ca-Sr-Zn-Si Glass Polyalkenoate Cement, A. Coughlan, N. M. Cummins, A. W. Wren, Mark R. Towler Jun 2011

The Effect Of Adding Organic Polymers To Ca-Sr-Zn-Si Glass Polyalkenoate Cement, A. Coughlan, N. M. Cummins, A. W. Wren, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

To conclude, the addition of polymers to GPCs resulted in little change to the Tw and Ts, however the compressive strength was found to decrease slightly. ASAP tests revealed that the cements may undergo some structural changes as a result of these additions. In the future perhaps the addition of organic polymers suspended in the liquid phase as part of the cement may yield improved results in this type of study. © 2011 IEEE.


Aluminium-Free Glass Polyalkenoate Spinal Cements, A. W. Wren, N. M. Cummins, Mark R. Towler Jun 2011

Aluminium-Free Glass Polyalkenoate Spinal Cements, A. W. Wren, N. M. Cummins, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

Addition of Yitanium increased the Wt & St and the sf strength of these cements compared to the control (BT 101). © 2011 IEEE.


Leaching Of Potential Hazardous Elements Of Coal Cleaning Rejects, Luis F.O. Silva, Maria Izquierdo, Xavier Querol, Robert B. Finkelman, Marcos L.S. Oliveira, Marcus Wollenschlager, Mark R. Towler, Rafael Pérez-López, Felipe Macias Apr 2011

Leaching Of Potential Hazardous Elements Of Coal Cleaning Rejects, Luis F.O. Silva, Maria Izquierdo, Xavier Querol, Robert B. Finkelman, Marcos L.S. Oliveira, Marcus Wollenschlager, Mark R. Towler, Rafael Pérez-López, Felipe Macias

Chemical and Biochemical Engineering Faculty Research & Creative Works

The geochemical characteristics of coal cleaning rejects (CCR) in Santa Catarina State, Brazil, were investigated. Around 3.5 million ton/ year of coal waste are dumped in Santa Catarina State. Coal beneficiation by froth flotation results in large amounts of CCR composed of coaly and mineral matter, the latter characterized by the occurrence of sulphide minerals and a broad array of leachable elements. The total and leachable contents of more than 60 elements were analyzed. Atmospheric exposure promotes sulphide oxidation that releases substantial sulphate loads as well as Ca2+, K+, Mg2+, Cl- and Al3+ …


The Structural Role Of Titanium In Ca-Sr-Zn-Si/Ti Glasses For Medical Applications, A. W. Wren, F. R. Laffir, A. Kidari, Mark R. Towler Feb 2011

The Structural Role Of Titanium In Ca-Sr-Zn-Si/Ti Glasses For Medical Applications, A. W. Wren, F. R. Laffir, A. Kidari, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

Glasses for medical applications are used in particulate form or as a cement component. This work was undertaken to determine structural changes in 0.48SiO2-0.36ZnO-0.12CaO-0.04SrO glass when the SiO2 is substituted with 5 mol% increments of TiO2. X-ray Diffraction (XRD) was used to determine the presence of crystallinity. This occurred after additions of 20 mol% TiO2. Differential Thermal Analysis (DTA) and Network connectivity (NC) calculations determined that by increasing the TiO2 content, the Tg and NC reduced (Tg 670 °C to 632 °C, NC 1.83 to -1.14) suggesting that TiO2 acts as …


The Bioactivity And Ion Release Of Titanium-Containing Glass Polyalkenoate Cements For Medical Applications, A. W. Wren, N. M. Cummins, F. R. Laffir, S. P. Hudson, Mark R. Towler Jan 2011

The Bioactivity And Ion Release Of Titanium-Containing Glass Polyalkenoate Cements For Medical Applications, A. W. Wren, N. M. Cummins, F. R. Laffir, S. P. Hudson, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

The ion release profiles and bioactivity of a series of Ti containing glass polyalkenoate cements. Characterization revealed each material to be amorphous with a Tg in the region of 650-660°C. The network connectivity decreased (1.83-1.35) with the addition of TiO2 which was also evident with analysis by X-ray photoelectron spectroscopy. Ion release from cements were determined using atomic absorption spectroscopy for zinc (Zn2+), calcium (Ca2+), strontium (Sr2+), Silica (Si4+) and titanium (Ti4+). Ions such as Zn2+ (0.1-2.0 mg/l), Ca2+ (2.0-8.3 mg/l,) Sr2+ (0.1-3.9 mg/l), and Si4+ …


The Response Of Pseudomonas Aeruginosa Biofilm To The Presence Of A Glass Polyalkenoate Cement Formulated From A Silver Containing Glass, A. Coughlan, M. P. Ryan, N. M. Cummins, Mark R. Towler Jan 2011

The Response Of Pseudomonas Aeruginosa Biofilm To The Presence Of A Glass Polyalkenoate Cement Formulated From A Silver Containing Glass, A. Coughlan, M. P. Ryan, N. M. Cummins, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

No abstract provided.


The Effect Of Ionic Dissolution Products Of Ca-Sr-Na-Zn-Si Bioactive Glass On In Vitro Cytocompatibility, S. Murphy, A. W. Wren, Mark R. Towler, D. Boyd Oct 2010

The Effect Of Ionic Dissolution Products Of Ca-Sr-Na-Zn-Si Bioactive Glass On In Vitro Cytocompatibility, S. Murphy, A. W. Wren, Mark R. Towler, D. Boyd

Chemical and Biochemical Engineering Faculty Research & Creative Works

Many commercial bone grafts cannot regenerate healthy bone in place of diseased bone. Bioactive glasses have received much attention in this regard due to the ability of their ionic dissolution products to promote cell proliferation, cell differentiation and activate gene expression. Through the incorporation of certain ions, bioactive glasses can become therapeutic for specific pathological situations. Calcium-strontium-sodium-zinc-silicate glass bone grafts have been shown to release therapeutic levels of zinc and strontium, however the in vitro compatibility of these materials is yet to be reported. In this study, the in vitro cytocompatibility of three different calcium-strontium-sodium-zinc-silicate glasses was examined as a …


Comparison Of Antibacterial Properties Of Commercial Bone Cements And Fillers With A Zinc-Based Glass Polyalkenoate Cement, A. W. Wren, N. M. Cummins, Mark R. Towler Oct 2010

Comparison Of Antibacterial Properties Of Commercial Bone Cements And Fillers With A Zinc-Based Glass Polyalkenoate Cement, A. W. Wren, N. M. Cummins, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

Postoperative infection following invasive surgical procedures is a significant cause for concern, particularly in spinal reconstructive surgery. The objective of this study is to compare the antibacterial efficacy of a novel zinc-based glass polyalkenoate cement (Zn-GPC) based on 0.04SrO-0.12CaO-0.36ZnO- 0.48SiO2 glass, to a number of commercially available bone cements and fillers including Simplex P + Tobramycin (STob), Spineplex (Spine) and Novabone Putty (NPut). The agar diffusion test was performed on each material against Escherichia coli, Staphlococcus epidermidis, Pseudomonas aeruginosa and Staphlococcus Aureus. STob was found to produce large inhibition zones in each …


A Spectroscopic Investigation Into The Setting And Mechanical Properties Of Titanium Containing Glass Polyalkenoate Cements, A. W. Wren, A. Kidari, N. M. Cummins, Mark R. Towler Aug 2010

A Spectroscopic Investigation Into The Setting And Mechanical Properties Of Titanium Containing Glass Polyalkenoate Cements, A. W. Wren, A. Kidari, N. M. Cummins, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

Titanium (Ti) implants are extensively used in a number of biomedical and dental applications. This work introduces Ti into the glass phase of a zinc-based glass polyalkenoate cement (GPC) and investigates changes in handling and mechanical properties considering two molecular weight polyacrylic acids (PAA), E9 and E11. Considering the handling properties, the working time (Tw) increased from 50 sE9, 32 sE11 (BT 101, Ti-free) to 169 sE9, 74 sE11 with TW-Z (highest Ti content), respectively. The setting time (Ts) increased from 76 sE9, 47 sE11 (BT 101) …


The Effect Of Adding Organic Polymers On The Handling Properties, Strengths And Bioactivity Of A Ca-Sr-Zn-Si Glass Polyalkenoate Cement, A. W. Wren, N. M. Cummins, A. Coughlan, Mark R. Towler Jul 2010

The Effect Of Adding Organic Polymers On The Handling Properties, Strengths And Bioactivity Of A Ca-Sr-Zn-Si Glass Polyalkenoate Cement, A. W. Wren, N. M. Cummins, A. Coughlan, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

This work demonstrates the addition of a number of naturally occurring proteins/polymers to a zinc-based glass polyalkenoate cements (GPCs). Chitin (Chi.), collagen (Col.), cysteine (Cys.) and keratin (Ker.) were added with the intention of improving the bioactivity of this cement. Initial testing involved characterization of the glass with X-ray diffraction (XRD) and differential thermal analysis (DTA) before and after sterilization with γ-irradiation. No significant changes occurred as a result of sterilization. Handling properties of the modified cements were not significantly different from those of the control, BT 101 (Working Tw-36s, and setting time Ts-70 …


Influence Of Morphology And Processing On Xps Characterisation Of Sro-Ca-Zno-Sio2 Glass, F. R. Laffir, A. W. Wren, Mark R. Towler Jun 2010

Influence Of Morphology And Processing On Xps Characterisation Of Sro-Ca-Zno-Sio2 Glass, F. R. Laffir, A. W. Wren, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

A study was conducted to demonstrate the influence of morphology and processing on X-ray photoelectron spectroscopic (XPS) characterization SrO-Ca-ZnO-SiO2 glass. The glass formulation being investigated was originally synthesized for developing a novel glass polyalkenoate cement (GPC). High resolution photoelectron spectra of Zn 2p, Ca 2p, Sr 3d, Si 2p, O 1s, and C 1s were recorded for the different forms of glass. It was observed that there was preferential enrichment of Zn2+ with an increase in the proportion of NBO for the investigated BT101 glass. The relative atomic concentration of Zn in BT101 glass was high and resulted …


Mechanical Properties Of Hydroxyapatite-Zirconia Compacts Sintered By Two Different Sintering Methods, Declan J. Curran, Thomas J. Fleming, Mark R. Towler, Stuart Hampshire Apr 2010

Mechanical Properties Of Hydroxyapatite-Zirconia Compacts Sintered By Two Different Sintering Methods, Declan J. Curran, Thomas J. Fleming, Mark R. Towler, Stuart Hampshire

Chemical and Biochemical Engineering Faculty Research & Creative Works

Microwave sintering is traditionally employed to reduce the sintering temperature required to densify powder compacts. The effect of microwave heating on hydroxyapatite (HA)-zirconia (ZrO2) green bodies has been investigated in order to understand how microwave energy may affect the physical and mechanical properties of the resultant densified composites. Laboratory synthesised nano-sized HA and a commercial nano-sized ZrO2 powder have been ball milled to create mixtures containing 0-5 wt% ZrO2 loadings. Compacts were microwave sintered at either 700, 1000 or 1200°C with a 1 h hold time. Comparative firings were also performed in a resistive element furnace …


Evaluation Of Two Novel Aluminum-Free, Zinc-Based Glass Polyalkenoate Cements As Alternatives To Pmma Bone Cement For Use In Vertebroplasty And Balloon Kyphoplasty, Gladius Lewis, Mark R. Towler, Daniel Boyd, Matthew J. German, Anthony W. Wren, Owen M. Clarkin, Andrew Yates Jan 2010

Evaluation Of Two Novel Aluminum-Free, Zinc-Based Glass Polyalkenoate Cements As Alternatives To Pmma Bone Cement For Use In Vertebroplasty And Balloon Kyphoplasty, Gladius Lewis, Mark R. Towler, Daniel Boyd, Matthew J. German, Anthony W. Wren, Owen M. Clarkin, Andrew Yates

Chemical and Biochemical Engineering Faculty Research & Creative Works

Vertebroplasty (VP) and balloon kyphoplasty (BKP) are now widely used for treating patients in whom the pain due to vertebral compression fractures is severe and has proved to be refractory to conservative treatment. These procedures involve percutaneous delivery of a bolus of an injectable bone cement either directly to the fractured vertebral body, VB (VP) or to a void created in it by an inflatable bone tamp (BKP). Thus, the cement is a vital component of both procedures. In the vast majority of VPs and BKPs, a poly(methyl methacrylate) (PMMA) bone cement is used. This material has many shortcomings, notably …


Fabrication Of Spherical Cao-Sro-Zno-Sio2 Particles By Sol-Gel Processing, Ill Yong Kim, Mark R. Towler, Anthony Wren, Chikara Ohtsuki Nov 2009

Fabrication Of Spherical Cao-Sro-Zno-Sio2 Particles By Sol-Gel Processing, Ill Yong Kim, Mark R. Towler, Anthony Wren, Chikara Ohtsuki

Chemical and Biochemical Engineering Faculty Research & Creative Works

This study was concerned with the fabrication of ceramic CaO-SrO-ZnO-SiO2 spherical particles, which are novel candidates for the glass phase in glass polyalkenoate cements (GPCs). GPCs made from these glasses have potential as bone cements because, unlike conventional GPCs, they do not contain aluminum ions, which inhibit the calcification of hydroxyapatite in the body. The glass phase of GPCs require a controllable glass morphology and particle size distribution. Sol-gel processing can potentially be used to fabricate homogenous ceramic particles with controlled morphology. However, a thorough study on preparation conditions of spherical CaO-SrO-ZnO-SiO2 particles by sol-gel processing has, to …


Characterisation And Mechanical Testing Of Hydrothermally Treated Ha/Zro2 Composites, D. J. Curran, T. J. Fleming, G. Kawachi, C. Ohtsuki, Mark R. Towler Nov 2009

Characterisation And Mechanical Testing Of Hydrothermally Treated Ha/Zro2 Composites, D. J. Curran, T. J. Fleming, G. Kawachi, C. Ohtsuki, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

Hydrothermal treatment is traditionally employed to improve the sinterability of powder compacts by reducing porosity and increasing apparent density. The effect of hydrothermal treatment on green powder compacts has been assessed in order to better understand how treatment may affect the sinter ability of the bodies. Laboratory synthesized nano sized hydroxyapatite (HA) and a commercial zirconia (ZrO2) powder have been ball milled together to create composite mixtures containing 0-5 wt% ZrO2 loadings. Disc shaped bodies have been formed using uniaxial and subsequent isostatic pressure. The resultant coherent samples were subjected to hydrothermal treatment at either 120 or …


Analysis Of Γ-Irradiated Synthetic Bone Grafts By ²⁹Si Mas-Nmr Spectroscopy, Calorimetry And Xrd, D. Boyd, S. Murphy, Mark R. Towler, A. W. Wren, S. Hayakawa Nov 2009

Analysis Of Γ-Irradiated Synthetic Bone Grafts By ²⁹Si Mas-Nmr Spectroscopy, Calorimetry And Xrd, D. Boyd, S. Murphy, Mark R. Towler, A. W. Wren, S. Hayakawa

Chemical and Biochemical Engineering Faculty Research & Creative Works

Ca-Sr-Zn-Si glasses have demonstrated excellent biocompatibility both in vitro using the MTT assay with L929 mouse fibroblast cells, and in vivo using healthy and ovariectomized female Wistar rats. However, the biological evaluation of the materials was performed on glass granules that were autoclaved, rather than γ-irradiated; the sterilisation procedure required prior to implantation of these materials in the human body. Given the fact that when a glass is exposed to ionizing radiation changes in its physical properties can take place, it is imperative to determine whether the structure of such glasses will be altered as a result of exposure to …


The Effect Of Glass Synthesis Route On Mechanical And Physical Properties Of Resultant Glass Ionomer Cements, A. Wren, O. M. Clarkin, F. R. Laffir, C. Ohtsuki, I. Y. Kim, Mark R. Towler Oct 2009

The Effect Of Glass Synthesis Route On Mechanical And Physical Properties Of Resultant Glass Ionomer Cements, A. Wren, O. M. Clarkin, F. R. Laffir, C. Ohtsuki, I. Y. Kim, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

Glass ionomer cements (GICs) have potential orthopaedic applications. Solgel processing is reported as having advantages over the traditional melt-quench route for synthesizing the glass phase of GICs, including far lower processing temperatures and higher levels of glass purity and homogeneity. This work investigates a novel glass formulation, BT 101 (0.48 SiO2-0.36 ZnO-0.12 CaO-0.04 SrO) produced by both the melt-quench and the solgel route. The glass phase was characterized by X-ray diffraction (XRD) to determine whether the material was amorphous and differential thermal analysis (DTA) to measure the glass transition temperature (Tg). Particle size analysis (PSA) was …


Comparison Of Failure Mechanisms For Cements Used In Skeletal Luting Applications, O. Clarkin, D. Boyd, Mark R. Towler Aug 2009

Comparison Of Failure Mechanisms For Cements Used In Skeletal Luting Applications, O. Clarkin, D. Boyd, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

Glass Polyalkenoate Cements (GPCs) based on strontium calcium zinc silicate (Sr-Ca-Zn-SiO2) glasses and low molecular weight poly (acrylic acid) (PAA) have been shown to exhibit suitable compressive strength (65 MPa) and flexural strength (14 MPa) for orthopaedic luting applications. In this study, two such GPC formulations, alongside two commercial cements (Simplex ® P and Hydroset™) were examined. Fracture toughness and tensile bond strength to sintered hydroxyapatite and a biomedical titanium alloy were examined. Fracture toughness of the commercial Poly(methyl methacrylate) cement, Simplex® P, (3.02 MPa m1/2) was superior to that of the novel GPC (0.36 MPa …


Comparison Of An Experimental Bone Cement With A Commercial Control, Hydroset™, O. M. Clarkin, D. Boyd, S. Madigan, Mark R. Towler Jul 2009

Comparison Of An Experimental Bone Cement With A Commercial Control, Hydroset™, O. M. Clarkin, D. Boyd, S. Madigan, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

Glass polyalkenoate cements based on strontium calcium zinc silicate glasses (Zn-GPCs) and high molecular weight polyacrylic acids (PAA) (MW; 52,000-210,000) have been shown to exhibit mechanical properties and in vitro bioactivity suitable for arthroplasty applications. Unfortunately, these formulations exhibit working times and setting times which are too short for invasive surgical applications such as bone void filling and fracture fixation. In this study, Zn-GPCs were formulated using a low molecular weight PAA (MW; 12,700) and a modifying agent, trisodium citrate dihydrate (TSC), with the aim of improving the rheological properties of Zn-GPCs. These novel formulations were then compared with commercial …


Biofilm Inhibitory Coatings Formulated From Glass Polyalkenoate Cement Chemistry: An Evaluation Of Their Adhesive Nature, A. Coughlan, D. Boyd, Mark R. Towler Mar 2009

Biofilm Inhibitory Coatings Formulated From Glass Polyalkenoate Cement Chemistry: An Evaluation Of Their Adhesive Nature, A. Coughlan, D. Boyd, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

Researchers evaluated the adhesive nature of the biofilm inhibitory coatings formulated from glass polyalkenoate cement (GPC) chemistry with the aim to establish the novel testing modality by modifying the conventional T-peel tests. Special consideration was given to determine the resistance of a bonded assembly of two adherents having at least one adherent flexible to quantify the bond between tape and a surgical metal substrate bonded by a luting GPC. The delaminated tape surface was examined by scanning electron microscopy (SEM) with an accelerating voltage of 20 K V to determine whether failure of the bond was adhesive of cohesive in …


Antibacterial Properties Of A Tri-Sodium Citrate Modified Glass Polyalkenoate Cement, A. W. Wren, D. Boyd, R. Thornton, J. C. Cooney, Mark R. Towler Jan 2009

Antibacterial Properties Of A Tri-Sodium Citrate Modified Glass Polyalkenoate Cement, A. W. Wren, D. Boyd, R. Thornton, J. C. Cooney, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

Primary deep infection following joint replacement surgery accounts for 7% of all revisions. Glass polyalkenoate cements (GPCs) have previously been shown to exhibit antibacterial properties. The present study had two objectives. The first was to determine if addition of tri-sodium citrate (TSC) to the powder phase of an Al-free GPC (0.04 SrO-0.12 CaO-0.36 ZnO-0.48 SiO2, by mole fraction) enhanced the resultant cement's antibacterial properties against three strains of bacteria that are commonly found in periprosthetic sites following total joint replacements (TJRs); namely, E. coli, B. fragilis, and S. epidermidis. Four cement sets were prepared, which contained 0 wt% TSC (control), …


Preliminary Investigation Of Novel Bone Graft Substitutes Based On Strontium-Calcium-Zinc-Silicate Glasses, D. Boyd, G. Carroll, Mark R. Towler, C. Freeman, P. Farthing, I. M. Brook Jan 2009

Preliminary Investigation Of Novel Bone Graft Substitutes Based On Strontium-Calcium-Zinc-Silicate Glasses, D. Boyd, G. Carroll, Mark R. Towler, C. Freeman, P. Farthing, I. M. Brook

Chemical and Biochemical Engineering Faculty Research & Creative Works

Bone graft procedures typically require surgeons to harvest bone from a second site on a given patient (Autograft) before repairing a bone defect. However, this results in increased surgical time, excessive blood loss and a significant increase in pain. In this context a synthetic bone graft with excellent histocompatibility, built in antibacterial efficacy and the ability to regenerate healthy tissue in place of diseased tissue would be a significant step forward relative to current state of the art philosophies. We developed a range of calcium-strontium-zinc-silicate glass-based bone grafts and characterized their structure and physical properties, then evaluated their in vitro …


Antibacterial Coatings For Medical Devices Based On Glass Polyalkenoate Cement Chemistry, A. Coughlan, D. Boyd, C. W.I. Douglas, Mark R. Towler Dec 2008

Antibacterial Coatings For Medical Devices Based On Glass Polyalkenoate Cement Chemistry, A. Coughlan, D. Boyd, C. W.I. Douglas, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

A biofilm is an accumulation of micro-organisms and their extracellular products forming a structured community on a surface. Biofilm formation on medical devices has severe health consequences as bacteria growing in this lifestyle are tolerant to both host defense mechanisms and antibiotic therapies. However, silver and zinc ions inhibit the attachment and proliferation of immature biofilms. The objective of this study is to evaluate whether it is possible to produce silver and zinc-containing glass polyalkenoate cement (GPC) coatings for medical devices that have antibacterial activity and which may therefore inhibit biofilm formation on a material surface. Two silver and zinc-containing …


Comparison Of An Experimental Bone Cement With Surgical Simplex® P, Spineplex® And Cortoss®, D. Boyd, Mark R. Towler, A. Wren, O. M. Clarkin Apr 2008

Comparison Of An Experimental Bone Cement With Surgical Simplex® P, Spineplex® And Cortoss®, D. Boyd, Mark R. Towler, A. Wren, O. M. Clarkin

Chemical and Biochemical Engineering Faculty Research & Creative Works

Conventional polymethylmethacrylate (PMMA) cements and more recently Bisphenol-a-glycidyl dimethacrylate (BIS-GMA) composite cements are employed in procedures such as vertebroplasty. Unfortunately, such materials have inherent drawbacks including, a high curing exotherm, the incorporation of toxic components in their formulations, and critically, exhibit a modulus mismatch between cement and bone. The literature suggests that aluminum free, zinc-based glass polyalkenoate cements (Zn-GPC) may be suitable alternative materials for consideration in such applications as vertebroplasty. This paper examines one formulation of Zn-GPC and compares its strengths, modulus, and biocompatibility with three commercially available bone cements, Spineplex®, Simplex® P and Cortoss®. The setting times indicate …


The Processing, Mechanical Properties And Bioactivity Of Strontium Based Glass Polyalkenoate Cements, Anthony Wren, Daniel Boyd, Mark R. Towler Apr 2008

The Processing, Mechanical Properties And Bioactivity Of Strontium Based Glass Polyalkenoate Cements, Anthony Wren, Daniel Boyd, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

The suitability of zinc-based glass polyalkenoate cements (GPCs) for use in orthopaedics can be improved by the substitution of strontium into the glass phase which should impart improved radiopacity and bone forming properties to the cements without retarding strength. The purpose of this research was to produce novel GPCs based on calcium-strontium-zinc-silicate glasses and to evaluate their mechanical properties and biocompatibility with the ultimate objective of developing a new range of cements for skeletal applications. Three glass compositions, based on incremental substitutions of strontium for calcium, were synthesized; BT100 (0.16CaO, 0.36ZnO, 0.48SiO2), BT101 (0.04SrO, 0.12CaO, 0.36ZnO, 0.48SiO2 …


The Role Of Sr²⁺ On The Structure And Reactivity Of Sro-Cao-Zno-Sio2 Ionomer Glasses, Daniel Boyd, Mark R. Towler, Sally Watts, Robert G. Hill, Anthony W. Wren, Owen M. Clarkin Feb 2008

The Role Of Sr²⁺ On The Structure And Reactivity Of Sro-Cao-Zno-Sio2 Ionomer Glasses, Daniel Boyd, Mark R. Towler, Sally Watts, Robert G. Hill, Anthony W. Wren, Owen M. Clarkin

Chemical and Biochemical Engineering Faculty Research & Creative Works

The suitability of Glass Polyalkenoate Cements (GPCs) for use in orthopaedics is retarded by the presence in the glass phase of aluminum, a neurotoxin. Unfortunately, the aluminum ion plays an integral role in the setting process of GPCs and its absence is likely to hinder cement formation. However, the authors have previously shown that aluminum free GPCs may be formulated based on calcium zinc silicate glasses and these novel materials exhibit significant potential as hard tissue biomaterials. To further improve their potential and given that Strontium (Sr) based drugs have had success in the treatment of osteoporosis, the authors have …


Tem Analysis Of Apatite Surface Layers Observed On Zinc Based Glass Polyalkenoate Cements, D. Boyd, Mark R. Towler, A. W. Wren, O. M. Clarkin, D. A. Tanner Feb 2008

Tem Analysis Of Apatite Surface Layers Observed On Zinc Based Glass Polyalkenoate Cements, D. Boyd, Mark R. Towler, A. W. Wren, O. M. Clarkin, D. A. Tanner

Chemical and Biochemical Engineering Faculty Research & Creative Works

The amorphous nature and composition of the surface apatite layers observed on glass polyalkenoate cements based on zinc silicate glasses (Zn-GPCs) after immersion in simulated body fluid (SBF) have been analyzed by the transmission electron microscopy (TEM). TEM was conducted using a JEOL JEM-2011 electron microscope operated at an accelerating voltage of 200 kV. The composition elements of the surface layer indicated the presence of calcium, phosphorous, zinc, and strontium within the amorphous structure. This composition, in particular the inclusion of Zn in the structure, indicates the lack of crystallinity associated with the formation of the apatite layers observed on …


Phase Transformations Of Calcium Phosphates Formed In Wet Field Environments, O. M. Clarkin, Mark R. Towler, G. M. Insley, M. E. Murphy Oct 2007

Phase Transformations Of Calcium Phosphates Formed In Wet Field Environments, O. M. Clarkin, Mark R. Towler, G. M. Insley, M. E. Murphy

Chemical and Biochemical Engineering Faculty Research & Creative Works

The crystal phase and morphology of calcium phosphate salts precipitated in a wet field environment at temperatures between 30 and 70 °C and pHs between 3 and 8 were examined. Dicalcium Phosphate Dihydrate (DCPD) was the most prevalent phase precipitated. Using accelerated ageing study techniques, precipitates studied were aged, under dry conditions at 50 °C for 8 and 16 days, before being re-examined using XRD, FTIR and SEM techniques. DCPD was found to be most stable when precipitated at 40 °C and 5 pH. Considerably more phase transformation to Octacalcium Phosphate (OCP), Amorphous Calcium Phosphate (ACP) and Hydroxyapatite (HA) was …


Influence Of Acid Washing On The Surface Morphology Of Ionomer Glasses And Handling Properties Of Glass Ionomer Cements, C. M. Crowley, J. Doyle, Mark R. Towler, N. Rushe, S. Hampshire Aug 2007

Influence Of Acid Washing On The Surface Morphology Of Ionomer Glasses And Handling Properties Of Glass Ionomer Cements, C. M. Crowley, J. Doyle, Mark R. Towler, N. Rushe, S. Hampshire

Chemical and Biochemical Engineering Faculty Research & Creative Works

Acid washing is known to influence the handling properties of ionomer glasses used in glass ionomer cements due to the production of an ion depleted zone on the surface of the glass particles. The influence of acid washing on the particle size distribution and surface area of four glasses was examined by scanning electron microscopy (SEM), particle size analysis (PSA) and accelerated surface area porosimetry (ASAP) and the working and setting times of cements, produced from the glasses, correlated to changes in surface morphology. A linear relationship was found between the specific surface area of acid-washed SiO2-Al2 …


Influence Of Two Changes In The Composition Of An Acrylic Bone Cement On Its Handling, Thermal, Physical, And Mechanical Properties, G. Lewis, J. Xu, S. Madigan, Mark R. Towler Aug 2007

Influence Of Two Changes In The Composition Of An Acrylic Bone Cement On Its Handling, Thermal, Physical, And Mechanical Properties, G. Lewis, J. Xu, S. Madigan, Mark R. Towler

Chemical and Biochemical Engineering Faculty Research & Creative Works

This study is a contribution to the growing body of work on the influence of changes in the composition of an acrylic bone cement on various properties of the curing and cured material. The focus is on one commercially-available acrylic bone cement brand, Surgical Simplex®P, and three variants of it and a series of properties, namely, setting time, maximum exotherm temperature, activation energy and frequency factor for the polymerization reaction, diffusion coefficient for the uptake of phosphate buffered saline, at 37°C, ultimate compressive strength (UCS), plane-strain fracture toughness, fatigue life (under fully-reversed tension-compression stress), hardness (H) and elastic modulus (both …