Open Access. Powered by Scholars. Published by Universities.®

Structural Engineering Commons™

Open Access. Powered by Scholars. Published by Universities.®

4,024 Full-Text Articles 5,476 Authors 4,392,718 Downloads 98 Institutions

All Articles in Structural Engineering

Faceted Search

4,024 full-text articles. Page 90 of 126.

Maneuverability Of Ships With Small Draught In Steady Wind, Daeng Paroka, Andi Haris Muhammad, Syamsul Asri 2016 Department of Naval Architect, Faculty of Engineering, Universitas Hasanuddin, Makassar 90245, Indonesia

Maneuverability Of Ships With Small Draught In Steady Wind, Daeng Paroka, Andi Haris Muhammad, Syamsul Asri

Makara Journal of Technology

Wind force and moment may force a ship to drastically decrease its speed and use a large drift angle as well as a large rudder angle in order to maintain its course. Ships with a small draught might have more risk in maneuvering to its point of view compared with a ship with a larger draught. This paper discusses maneuverability of a ship with a small draught in steady wind. The effect of wind on ship speed, drift angle, and rudder angle are investigated in a steady state condition. Five different ratios of wind velocity to ship speed from 1.0 …


Cyclic Behavior Of A Hybrid Light Gauge And Hss Mezzanine Structural System, Michael John Kren 2016 Marquette University

Cyclic Behavior Of A Hybrid Light Gauge And Hss Mezzanine Structural System, Michael John Kren

Master's Theses (2009 -)

Cold-formed steel is emerging as an alternative material in the building industry to hot-rolled steel for smaller buildings and indoor structures also called mezzanines. Cyclic testing of a full-scale mezzanine structures composed of cold-formed structural channel beams connected to hollow structural steel (HSS) columns cap plates using wedge expansion anchors at the base plate to generate rotation restraint, is performed in this research. The characteristics of the structure will be explained by displaying full experimental results of structural testing. Unfortunately, limited experimental data outlining the behavior of these structures is available and design criteria is very limited. Thus, there is …


A Comparison Of American, Norwegian, And Russian Standards In Calculating The Wall Thickness Of Submarine Gas Pipeline, Cindy Dianita, Tatyana Vladimirovna Dmitrieva 2016 Department of Chemical Engineering, Faculty of Engineering, Universitas Indonesia, Depok 16424, Indonesia

A Comparison Of American, Norwegian, And Russian Standards In Calculating The Wall Thickness Of Submarine Gas Pipeline, Cindy Dianita, Tatyana Vladimirovna Dmitrieva

Makara Journal of Technology

One of the key issues in the pipeline design is wall thickness calculation. This paper highlights a comparison of wall thickness calculation methods of submarine gas pipeline based on Norwegian Standard (DNV-OS-F101), Indonesian Standard SNI 3474 which refers to American Standard (ASME B31.8), and Russian Standard (VN39-1.9-005-98). A calculation of wall thickness for a submarine gas pipeline in Indonesia (pressure 12 MPa, external diameter 668 mm) gives the results of 18.2 mm (VN39-1.9-005-98), 16 mm (ASME B31.8), and 13.5 mm (DNV-OS-F101).The design formula of hoop stress due to internal pressure is interpreted in different ways for every standard. Only Norwegian …


Post-Repair Seismic Assessment Of Rc Bridges Damaged With Fractured Column Bars - A Numerical Approach, Ruili He, Yang Yang, Lesley H. Sneed 2016 Missouri University of Science and Technology

Post-Repair Seismic Assessment Of Rc Bridges Damaged With Fractured Column Bars - A Numerical Approach, Ruili He, Yang Yang, Lesley H. Sneed

Civil, Architectural and Environmental Engineering Faculty Research & Creative Works

Seismic repair of reinforced concrete (RC) bridge columns has been studied extensively during the past several decades; however, few studies have been conducted on the influence of the column repair (member level) on the post-repair performance of bridge structures (system level). In a previous experimental study by the authors, a method was developed to rapidly repair severely damaged RC bridge columns to enable the quick reopening of the bridge to emergency traffic. Thus, a lower limit state was used for the repair design, so that the lateral strength and drift capacity of a repaired RC column with fractured longitudinal bars …


Behavior Of Prestressed Concrete Beams With Cfrp Strands, Yasir Matloob Saeed 2016 Portland State University

Behavior Of Prestressed Concrete Beams With Cfrp Strands, Yasir Matloob Saeed

Dissertations and Theses

The high cost of repairing reinforced or prestressed concrete structures due to steel corrosion has driven engineers to look for solutions. Much research has been conducted over the last two decades to evaluate the use of Fiber Reinforced Polymers (FRPs) in concrete structures. Structural engineering researchers have been testing FRP to determine their usability instead of steel for strengthening existing reinforced concrete structures, reinforcing new concrete members, and for prestressed concrete applications. The high strength-to-weight ratio of FRP materials, especially Carbon FRP (CFRP), and their non-corrosive nature are probably the most attractive features of FRPs.

In this study, an experimental …


Wildcat Bridge - I-65 Artesion Well/Geotechnical/Structural, Anne Rearick, Jeremy Hunter, Silas Nichols, Mir Zaheer 2016 Indiana Department of Transportation

Wildcat Bridge - I-65 Artesion Well/Geotechnical/Structural, Anne Rearick, Jeremy Hunter, Silas Nichols, Mir Zaheer

Purdue Road School

In this session we will discuss the emergency design and repair of the I-65 bridge over Wildcat Creek in Tippecanoe County during the summer of 2015 that closed I-65 northbound.


Storm Damage - Floating Culverts, Dale Sedler, Mark Bailey 2016 Indiana Department of Transportation

Storm Damage - Floating Culverts, Dale Sedler, Mark Bailey

Purdue Road School

A review of buoyancy issues culverts experience due to blockage. Includes discussion of blockage due to floating debris and issues with multiple culverts. Provides information on characteristics that help to determine if a culvert has "floated."


Evaluation Of Strength Reduction Factor For Concentrically Braced Frames Based On Nonlinear Single Degree-Of-Freedom Systems, Ryan Michael Slein 2016 California Polytechnic State University, San Luis Obispo

Evaluation Of Strength Reduction Factor For Concentrically Braced Frames Based On Nonlinear Single Degree-Of-Freedom Systems, Ryan Michael Slein

Master's Theses

Strength Reduction Factor (R-Factor), often referred to as Response Modification Factor, is commonly used in the design of lateral force resisting systems under seismic loading. R-Factors allow for a reduction in design base shear demands, leading to more economical designs. The reduction of strength is remedied with ductile behavior in members of proper detailing. Modern seismic codes and provisions recommend R-Factors for many types of lateral force resisting systems. However these factors are independent of the system fundamental frequency and many other important system properties, resulting in factors that may result in an unfavorable seismic response. To evaluate the validity …


Thermal Mass Behaviour Of Concrete Panels Incorporating Phase Change Materials, Dervilla Niall, Roger West, Sarah McCormack, Oliver Kinnane 2016 Technological University Dublin

Thermal Mass Behaviour Of Concrete Panels Incorporating Phase Change Materials, Dervilla Niall, Roger West, Sarah Mccormack, Oliver Kinnane

Conference papers

Phase Change Materials (PCM) have been incorporated into a range of building envelope materials with varied success. This study investigates two different methods of combining concrete and phase change materials to form PCM/concrete composite panels. The first method involves adding microencapsulated paraffin to fresh concrete during the mixing process. The second method involves vacuum impregnating butyl stearate into lightweight aggregate which is then included in the concrete mix design. The primary aim of the study is to determine which method is the most effective way to improve the thermal mass characteristics of a concrete panel in the context of a …


Resistance Of Arc Spot Welds -- Update To Provisions, American Iron and Steel Institute 2016 Missouri University of Science and Technology

Resistance Of Arc Spot Welds -- Update To Provisions, American Iron And Steel Institute

American Iron and Steel Institute (AISI) Specifications, Standards, Manuals and Research Reports (1946 - present)

The provisions of the AISI S100-12 standard for strength of arc spot welds loaded in shear and tension have not been revised since the 1999 standard. Since then, four new research studies have created and tested arc spot welded connections, expanding the database of available tests. Therefore, a reconsideration of both the resistance equations and the resistance and safety factors using the enlarged data base was undertaken. This study performed a comprehensive analysis of the entire arc spot weld data base, where 450 specimens were categorized by their respective failure modes to assess current AISI S100-12 resistance equations. Performance of …


Resistance Of Arc Spot Welds – Update To Provisions, B. Paige Blackburn, Thomas Sputo, Cevyn Meyer 2016 Missouri University of Science and Technology

Resistance Of Arc Spot Welds – Update To Provisions, B. Paige Blackburn, Thomas Sputo, Cevyn Meyer

American Iron and Steel Institute (AISI) Specifications, Standards, Manuals and Research Reports (1946 - present)

The American Iron and Steel Institute (AISI) Standards Council selected this project as one of four winning research proposals for its 2015 Small Project Fellowship Program. Project selections were based on several factors, including the potential for long-term impact on the industry; steel industry engagement and co-funding; and results for the AISI standards development committee, the student, and the academic institution. The objective of this project was to evaluate the provisions for determining the strength of arc spot welds in light of recent research studies. It is anticipated that the results of this study will impact the provisions in future …


Design Live Load Factor Calibration For Michigan Highway Bridges, Christopher D. Eamon, Valid Kamjoo, Kazuhiko Shinki 2016 Wayne State University

Design Live Load Factor Calibration For Michigan Highway Bridges, Christopher D. Eamon, Valid Kamjoo, Kazuhiko Shinki

Civil and Environmental Engineering Faculty Research Publications

In this study, a reliability-based calibration of live load factors for bridge design specific to the State of Michigan was conducted. Two years of high frequency WIM data from 20 representative state-wide sites were analyzed, and load effects were generated for bridge spans from 6 to 122 m (20 to 400 ft), considering simple and continuous moments and shears, as well as single lane and two lane effects. Seventy-five year statistics for maximum live load were then estimated with probabilistic projection. Bridge girders considered for the calibration included composite steel, prestressed concrete, side-by-side and spread box beams, as well as …


Daylighting And Thermo-Electrical Performance Of An Autonomous Suspended Particle Device Evacuated Glazing, Aritra Ghosh 2016 Technological University Dublin

Daylighting And Thermo-Electrical Performance Of An Autonomous Suspended Particle Device Evacuated Glazing, Aritra Ghosh

Doctoral

Suspended particle device (SPD) glazing is an AC powered switchable glazing. PV powered SPD evacuated (vacuum) glazing was proposed with the potential of reducing the heating demand, cooling demand and artificial lighting demand of a building. To achieve an autonomous SPD vacuum glazing, semi empirical simulation and outdoor characterisation was explored in this thesis. Transmission of SPD glazing (area 0.058 m2) varied from 5% when opaque to 55% when transparent in the presence of 110 V, 0.07 W AC supply was characterised in outdoor test cell in Dublin. The SPD glazing has variable spectral transmission in the presence of variable …


Late Morning Concurrent Sessions: Innovations In Aviation Technologies: Presentation: Relative Material Loss: A Methodology For Assessing Island Airport Steel Marine Bulkheads, Robert Ernsting, Constantine M. Koursaris 2016 Embry-Riddle Aeronautical University - Worldwide

Late Morning Concurrent Sessions: Innovations In Aviation Technologies: Presentation: Relative Material Loss: A Methodology For Assessing Island Airport Steel Marine Bulkheads, Robert Ernsting, Constantine M. Koursaris

Aviation / Aeronautics / Aerospace International Research Conference

A July 2015 report from the Airports Council International – North America (ACI-NA) states “U.S. airports are long overdue for [a] major structural improvement projects. Most U.S. airports are aging, … and because of budgetary restrictions, they’re not aging well.”(Garcia and Clampet, 2015). The average US age is 40 years old with the youngest (Denver International) recently turning 20 years old. As airports continue to age, airport commissioners will struggle to find creative ways to either fund airport replacements or extend the service life of existing airport facilities (commonly referred to as service life extension projects or SLEP). Due to …


Field Tests Of Two Prestressed Concrete Girder Bridges For Live Load Distribution And Moment Continuity, Christopher D. Eamon, Alaa Chehab, Gustavo Parra-Montesinos 2016 Wayne State University

Field Tests Of Two Prestressed Concrete Girder Bridges For Live Load Distribution And Moment Continuity, Christopher D. Eamon, Alaa Chehab, Gustavo Parra-Montesinos

Civil and Environmental Engineering Faculty Research Publications

Two similar bridges constructed with a live load continuous connection were tested for live load distribution and joint continuity. Girder distribution factors (GDFs) were compared to AASHTO equivalent values. For positive moments on all girders as for negative moments on interior girders, results using AASHTO equivalent GDFs were found to be generally conservative. However, for negative moments on exterior girders, test results exceeded AASHTO values, with 2-lane results significantly so. GDF results were verified with a FEA model, which produced similar behavior to the field tests. With respect to joint continuity, it is estimated that a simple span would produce …


State-Of-The-Art Review Of Cathodic Protection For Reinforced Concrete Structures, Aimee Byrne, Niall Holmes, Brian Norton 2016 Technological University Dublin

State-Of-The-Art Review Of Cathodic Protection For Reinforced Concrete Structures, Aimee Byrne, Niall Holmes, Brian Norton

Articles

Cathodic protection (CP) limits the corrosion of a metal surface by making it the cathode of an electrochemical cell. This can be achieved either by using a more active sacrificial anode to create a driving current, or by using inert anodes and impressing a current onto the cathode surface using an external direct current (DC) source. Impressed current cathodic protection (ICCP) is preferred where widespread protection is required, particularly in reinforced concrete structures. ICCP needs a constant DC power supply that is usually provided through a grid connection or independent generators. This paper presents the currently available CP systems for …


Case Studies Of Cavity And External Wall Insulation Retrofitted Under The Irish Home Energy Saving Scheme: Technical Analysis And Occupant Perspectives, Aimee Byrne, Gerard Byrne, Garrett O'Donnell, Anthony Robinson 2016 Technological University Dublin

Case Studies Of Cavity And External Wall Insulation Retrofitted Under The Irish Home Energy Saving Scheme: Technical Analysis And Occupant Perspectives, Aimee Byrne, Gerard Byrne, Garrett O'Donnell, Anthony Robinson

Articles

The residential sector represents 27% of primary energy consumption in Ireland. This paper examines the case study of the Irish government’s national grant scheme to encourage energy efficiency retrofit in private housing. That is the Home Energy Saving (HES) Scheme, later rebranded the Better Energy: Homes (BEH) Scheme. The methodology involved monitoring several homes immediately before and after retrofit alongside discussions with occupants. The examination focused on specific measures commonly introduced through the HES/BEH programme − cavity and external wall insulation. It has been found that a significant decrease in heat loss through the walls was measured in all cases. …


A Comparative Life Cycle Assessment For Utilising Laminated Veneer Bamboo As A Primary Structural Material In High-Rise Residential Buildings, Philip Kavanagh 2016 Technological University Dublin

A Comparative Life Cycle Assessment For Utilising Laminated Veneer Bamboo As A Primary Structural Material In High-Rise Residential Buildings, Philip Kavanagh

Masters

In a time when construction is ranked as one of the world’s least sustainable industries consuming about half of the world’s non-renewable resources (Hinson, 2012), it is important to develop and advance the methods and means by which we select and use building materials and how we design, engineer and construct our architecture. This research aimed to evaluate a method for utilising laminated veneer bamboo (LVB) as a primary structural material in high-rise residential buildings and evaluate the environmental potential of LVB through a comparative life cycle analysis (LCA). The process of life cycle analysis was completed through the development …


Circular Rc Columns Partially Confined With Frp, Sahar Y. Ghanem 2016 University of Kentucky

Circular Rc Columns Partially Confined With Frp, Sahar Y. Ghanem

Theses and Dissertations--Civil Engineering

Wrapping reinforced concrete (RC) columns with Fiber Reinforced Polymer (FRP) composites is effective in increasing their capacity. The current state of art concentrates primarily on fully wrapped RC columns and few studies dealt with partially wrapped columns. The majority of the studies did not account for the influence of the existing steel reinforcement on the column’s behavior. Other studies estimated the total confinement pressure as the sum of the confinement pressure due to the external FRP jacketing and due to the internal transverse steel reinforcement. Few models dealt with the coupled effect of the confinement from steel and partial FRP …


Behavior Of Rc Beams Strengthened In Flexure With Spliced Cfrp Rod Panels, Akram Rasheed Jawdhari 2016 University of Kentucky

Behavior Of Rc Beams Strengthened In Flexure With Spliced Cfrp Rod Panels, Akram Rasheed Jawdhari

Theses and Dissertations--Civil Engineering

FRP laminates and fabrics, used as an externally bonded reinforcement (EBR) to strengthen or repair concrete members, have proven to be an economical retrofitting method. However, when used to strengthen long-span members or members with limited access, the labor and equipment demands may negate the benefits of using continuous EBR FRP. Recently, CFRP rod panels (CRPs) have been developed and deployed to overcome the aforementioned limitations. Each CRP is made of several small diameter CFRP rods placed at discrete spacing. To fulfill the strengthening length, CRP’s are spliced together and made continuous by means of overlaps (or finger joints).

In …


Digital Commons powered by bepress