Investigation Of Microstructure Of Cementitious Materials Exposed To High Temperature By Non-Destructive Integrated Ct-Xrd Method,
2019
Hokkaido University
Investigation Of Microstructure Of Cementitious Materials Exposed To High Temperature By Non-Destructive Integrated Ct-Xrd Method, Takuya Mikami, H Takahashi, T Sugiyama
International Conference on Durability of Concrete Structures
Severe accident occurred in 2011 at the Fukushima Daiichi nuclear power plant and it can be assumed that the concrete building was exposed to high temperatures environment for a long time due to loss of the cooling function of the nuclear reactor. In order to prepare for the best scenario in the decommission plan, it should be first needed to clarify and evaluate the level of damage and deterioration of the contaminated concrete. To solve this problem, experiments were conducted for cementitious materials with the maximum temperature of 400 or 1000 degrees Celsius with durations of up to 2 hours. …
Influence Of Pore Structure On Relative Chloride Diffusion Coefficient In Unsaturated Cementitious Materials,
2019
Delft University of Technology
Influence Of Pore Structure On Relative Chloride Diffusion Coefficient In Unsaturated Cementitious Materials, Yong Zhang, Guang Ye
International Conference on Durability of Concrete Structures
Chloride-induced corrosion of reinforcement in concrete structures is a serious issue in engineering practice. This paper investigates the influence of pore structure on the relative chloride diffusion coefficient Drc in unsaturated cementitious materials. The effects of various pore features, including porosity, pore size, and pore connectivity, on the continuity of water-filled pores in unsaturated porous systems are analyzed based on the Kelvin law and water desorption process. In the experimental program, different cementitious materials (OPC, slag, fly ash, and limestone powder) were used to prepare paste and mortar samples. The Drc of the mortar samples (one year old) at various …
Development Of Engineered Cementitious Composites With Conductive Inclusions For Use In Self-Sensing Applications,
2019
Heriot-Watt University
Development Of Engineered Cementitious Composites With Conductive Inclusions For Use In Self-Sensing Applications, Benny Suryanto Dr, Danah Saraireh Ms, Steven Walls Mr, Jaehwan Kim Dr, W John Mccarter Prof
International Conference on Durability of Concrete Structures
The mechanical and a.c. electrical properties of a new varietal of engineered cementitious composite (ECC) incorporating conductive inclusions are presented. Electrical measurements were undertaken over a wide frequency range while curing and when under uniaxial tensile loading to study the influence of ongoing hydration and multiple microcrack formation on the composite electrical impedance. When presented in Nyquist format, the work shows that conductive inclusions reduce the bulk resistance of the composite while enhancing its polarizability, transforming the classic, single-arc bulk response of typical cement-based materials to a two-arc response. The bulk resistance was shown to increase with time and damage, …
Diagnosis On Expansion Of Heat-Cured Precast Concrete Blocks Due To Delayed Ettringite Formation In Japan,
2019
Purdue University
Diagnosis On Expansion Of Heat-Cured Precast Concrete Blocks Due To Delayed Ettringite Formation In Japan, Yuichiro Kawabata
International Conference on Durability of Concrete Structures
Delayed ettringite formation (DEF) in concrete causes internal swelling, which reduces the mechanical properties of concrete and can lead to issues with concrete structures due to potentially large expansive deformation. In order to address the issues of DEF-affected structures, proper assessment of the structures affected is important. However, petrographic diagnosis of concrete affected by DEF remains a controversial issue. In this paper, as case studies, diagnosis on precast concrete blocks suspected of experiencing DEF was carried out. The concrete blocks were made of white Portland cement, limestone gravel, and limestone sand mixed with copper slag. The blocks were excessively heat-cured …
Rehabilitation Of Low Rise Rcc Structure Along 9m High Retaining Wall,
2019
Aniruddha Nakhawa Structural Consultants, Mumbai India.
Rehabilitation Of Low Rise Rcc Structure Along 9m High Retaining Wall, Aniruddha Nakhawa Er, Vivek Deshmukh Dr
International Conference on Durability of Concrete Structures
Mumbai is the financial, commercial and entertainment capital of India, facing bigger challenges in accommodating its over growing population day by day. The Mumbai City has population of 18.4 million over its 634 km2 area, ie. Almost 350 ft2/person. This enormous rise in population density has restricted the development to expand vertically. This also, results in growth of major slums, which is almost 62% of the population dwelling in slums. Subsequently, the authorities is in need of a large scaled Slum Sanitation Program, which utilize the scarcely available land for construction of Community Toilet Blocks with involvement of NGO’s and …
A “Double-Multi” Model For Electromigration Of Lithiums And Chlorides In Asr Affected Concrete,
2019
State Key Laboratory of Ocean Engineering, Shanghai Jiao Tong University
A “Double-Multi” Model For Electromigration Of Lithiums And Chlorides In Asr Affected Concrete, Qing-Feng Liu, Li-Xuan Mao, Zhi Hu, Jin Xia, Gan-Lin Feng, Long-Yuan Li
International Conference on Durability of Concrete Structures
Existing reinforced concrete structures experience severe durability degradation when subjected to alkali– silica reaction (ASR) and chloride attack. A special electrochemical rehabilitation treatment, containing lithium compound anolyte, has been developed to drive lithium ions into concrete as well as remove chlorides simultaneously, for mitigating both the ASR-induced cracks and the chloride-induced corrosion. Good performance of introduced lithiums in controlling ASR-induced expansion has already been proved. Unfortunately, the migration mechanism of lithium in concrete under an external electric field is seldom investigated in existing literature. In this study, with help of the “double-multi” model, the efficiency of impregnation of lithium ions …
Distribution Of Lithium Nitrite Injected Into Concrete And Its Asr Suppression Effect,
2019
Gifu University
Distribution Of Lithium Nitrite Injected Into Concrete And Its Asr Suppression Effect, Koichi Kobayashi, K Rokugo, Y Takagi, T Otani
International Conference on Durability of Concrete Structures
In this research, lithium nitrite was injected into ASR-deteriorated concrete specimens made with reactive aggregates in order to suppress further deterioration. The amount of injected lithium nitrite was set to three different levels, and the subsequent expansion behavior and area of lithium permeation were investigated. The area of permeation was checked using the coloring reagent TDI. It was found that the prescribed amount of lithium cannot be injected fully into the non-deteriorated specimens. When the lithium was injected at an early stage of deterioration, the area of permeation was small and the ASR suppression effect was small regardless of the …
Mortar Quality Assessment For An Iconic Building Repair In Sydney Australia,
2019
Boral, Australia
Mortar Quality Assessment For An Iconic Building Repair In Sydney Australia, Ion Dumitru, Tony Song, John Sury, Tom Wenzel
International Conference on Durability of Concrete Structures
Remedial work for an iconic building in Sydney, Australia is currently being carried out. Two façade mortars, capable of matching the current exposed quartz aggregate finish and achieving a 40 years design life, are required. In order to ensure the quality of the imported quartz aggregates for this project, test have been carried out for particle size distribution, density, wet/dry strength variation, sodium sulphate soundness and Los Angeles Abrasion value. The two mortar mixes employed for repair work (Form & Pour and Hand Applied mixes) were comprehensively assessed for mix workability, compressive strength in warm and cold conditions, drying shrinkage, …
Efficiency Of Electrochemical Chloride Removal From Concrete At Different Environmental Temperatures,
2019
Institute of Structural Engineering, Zhejiang University, Hangzhou, China
Efficiency Of Electrochemical Chloride Removal From Concrete At Different Environmental Temperatures, Shijie Jin, Jin Xia, Weiliang Jin, Zhi-Yong Yu, Jia-Yuan Hu, Qingfang Lyu, Xiaoping Zhong
International Conference on Durability of Concrete Structures
Electrochemical chloride removal (ECR) is an effective and curative method to treat existed reinforced concrete structures about to suffer or already suffering from chloride attack, however, its application is still limited due to its side effect and efficiency, including the velocity and maximum capacity of chloride removal. This paper presents a temperature related numerical transport model to study the effect of temperature on efficiency of electrochemical chloride removal from concrete. Based on Fick’s law and Nernst-Planck equation with Gauss’ Law, temperature effect, chloride binding, multi-species coupling, electrochemical reactions were taken into account in this model. Temperature effect was considered on …
Comparison Data Between Hybrid And Galvanic Anode Installation In The Arousa Island Bridge,
2019
Neto Ingenieria
Comparison Data Between Hybrid And Galvanic Anode Installation In The Arousa Island Bridge, José Antonio Becerra Mosquera, Diego Carro López, José Enrique Pardo Landrove, José Manuel Millán Pérez
International Conference on Durability of Concrete Structures
The Arousa Island Bridge, with its 1980 m is the only road access to the Arousa Island. Built in 1985, this single-cell box girder divided in 40 spans runs entirely on the sea. The deck is between 2 to 12 m above sea level, so after 25 years in a marine environment, the structure showed reinforcement corrosion, especially in piles and deck bottom. Attending to the corrosion damages, caused simply from a chloride attack, the local government decided to intervene with an ambitious repair project. This decision has been taken only after an exhaustive cost analysis to determine the feasibility …
Monitoring Historic Concrete And Associated Cementitious Repair- A Case Study Of Boathouse 4, Portsmouth Historic Dockyard, Uk,
2019
university of Portsmouth, uk
Monitoring Historic Concrete And Associated Cementitious Repair- A Case Study Of Boathouse 4, Portsmouth Historic Dockyard, Uk, Ahmed Alwaal, Stepanie Barnett, Robert Inkpen, Linley Hastewell
International Conference on Durability of Concrete Structures
This study presents a method of monitoring historic concrete and associated repairs. A case study of Boathouse 4, Portsmouth Historic Dockyard, UK is presented. Boathouse 4 is an iconic building within Portsmouth Historic Dockyard which was constructed during the 1930’s rearmament period. It was used during World War ll to construct the three-man midget X-Craft submarine. The building was restored and converted into a Boatbuilding Skills Training Centre in 2015. A field investigation was conducted to analyse the concrete damage and to monitor microscale changes to the surface of the original concrete and repairs over a period of three years. …
Improvements Of The Carbonation Resistance Of Concrete After Steam Autoclave Curing,
2019
China University of Mining Technology - Xuzhou
Improvements Of The Carbonation Resistance Of Concrete After Steam Autoclave Curing, Guo Li, Jiang Yue, Feng Yao
International Conference on Durability of Concrete Structures
Incorporation of mineral admixtures, secondary water curing, and surface treatments were performed to improve the carbonation resistance of concrete after steam autoclave curing. The mineral admixtures used were fly ash, slag, and a mixture of both, and the surface treatments applied were those of organic silicone (OS) water repellent and epoxy resin (ER) coating. Accelerated carbonation experiments were performed on specimens at 28, 90, 180, and 360 d. Experimental results indicated that steam autoclave curing significantly reduces concrete carbonation resistance compared with standard curing. Secondary water curing for one week can replenish water in concrete and further hydrate …
Transport Properties Of Steam Curing Concrete Using Mineral Admixtures,
2019
Nagasaki University, Nagasaki, Japan
Transport Properties Of Steam Curing Concrete Using Mineral Admixtures, Kenji Sasaki, Tetsuo Harada, Tsuyoshi Katayama
International Conference on Durability of Concrete Structures
Steam curing has been used widely in the precast concrete industry. However, investigations on steam curing concrete focused mainly on their strength development. Research on durability of steam curing concrete, particularly on mixes using mineral admixtures, is somewhat limited.
In this study, transport properties and mechanical properties of concretes using mineral admixtures under different steam curing conditions were measured. Normal Portland cement, high early strength Portland cement, ground granulated blast-furnace slag and fly ash were used. Steam curing conditions were varied by changing the preliminary curing time, temperature drop rate and curing method after steam curing. Transport properties, such as …
Characterization Of Vibration Effects On The Internal Structure And Strength Of Regular And High Strength Recycled Concrete,
2019
Department of Civil and Environmental Engineering, University of the West Indies
Characterization Of Vibration Effects On The Internal Structure And Strength Of Regular And High Strength Recycled Concrete, Jovanca Smith, Rekha Rampit, R. Parey
International Conference on Durability of Concrete Structures
There is a need for more in depth understanding of the consolidation effect of concrete on its durability, especially in tropical climates. During placement of fresh concrete in molds vibration is required to prevent quality problems such as honeycombs and desegregation. Nevertheless, precise monitoring of concrete vibration time has been avoided by construction professionals. This results in concrete durability reduction of appropriately designed concrete due to variation in aggregate settlement, air void content and change in water to cement ratio. In this study, the effects of vibration time on concrete strength, aggregate segregation, and physical properties were experimentally investigated on …
A Novel Methodology Of Powder-Based Cementitious Materials In 3d Inkjet Printing For Construction Applications,
2019
University of Technology Sydney
A Novel Methodology Of Powder-Based Cementitious Materials In 3d Inkjet Printing For Construction Applications, Pshtiwan Shakor, Shami Nejadi, Gavin Paul, Jay Sanjayan
International Conference on Durability of Concrete Structures
Recently, additive manufacturing techniques such as 3D printing are becoming increasingly popular and widely used in a variety of applications. Inkjet 3D printing (i.e. powder-based printing) is one of the most reliable frequently-implemented techniques in 3D printers. This paper discusses a novel methodology to replace the currently used typical powders in 3D printing to make it possible to use the printed specimens in construction applications. The printed cubic (20Í20Í20mm) and prism (60Í5Í5mm) specimens with different saturation levels are printed to investigate the relative strength of the 3D printed specimens. Curing in different …
Improving The Spacer-Concrete Interface For Bond Strength And Durability,
2019
Imperial College London
Improving The Spacer-Concrete Interface For Bond Strength And Durability, Fadhilah Muslim, H. S. Wong, N. R. Buenfeld
International Conference on Durability of Concrete Structures
Spacers are important devices in reinforced concrete that are used to support reinforcing steel during concreting in order to achieve the required concrete cover. They are placed at every meter length or less of steel reinforcement and left permanently in the structure. However, it has been shown that the weak interface between spacer and concrete is highly porous and microcracked. This lowers the resistance of the concrete cover to ingress of aggressive agents causing degradation. This study aims to address this problem by improving spacer design to enhance bond strength and durability of the spacer-concrete interface. Cementitious spacers with a …
Performance Oriented Functionalisation Of Concrete: An Integrated Approach For Prevention In Construction,
2019
Karlsruhe Institute of Technology (KIT)
Performance Oriented Functionalisation Of Concrete: An Integrated Approach For Prevention In Construction, Andreas Gerdes, Matthias Schwotzer, Julia Süßmuth
International Conference on Durability of Concrete Structures
The long-term preservation and the future-oriented development of the infrastructure are of utmost importance for every country in the world. An increasing failure of infrastructure underpins a tremendous need for action. The reasons for this unsatisfactory situation are various, but certainly among them is often an insufficient performance of the building materials. This holds particularly true for reinforced concrete and its additives, which are nowadays commonly developed by empirical research. Almost all shortcomings of concrete durability are related to the transport of detrimental substances into the pore system. In this regard, a promising approach to prevent chemical deterioration processes is …
Development Of A New Method To Reduce Drying Shrinkage Of Concrete By Applying Urea,
2019
Utsunomiya University, Utsunomiya City, Japan
Development Of A New Method To Reduce Drying Shrinkage Of Concrete By Applying Urea, Kosuke Shirayama, H. Fujiwara, M. Maruoka, L Lingling
International Conference on Durability of Concrete Structures
Cracking of concrete caused by drying shrinkage adversely affects the durability of the structure. In the past research results, it is effective to add urea to concrete as a way to reduce drying shrinkage. However, in ready mixed concrete factory in Japan, adding various admixture materials to concrete will increase equipment costs and labor costs because of the increase in the number of input items, the management problem and putting problem when mixing.
In this research, in consideration of the above problems, we attempted to develop a cheaper and simpler method to apply or infiltrate the urea solution on the …
Surface Treatments For Concrete Under Physical Salt Attack,
2019
University of Manitoba
Surface Treatments For Concrete Under Physical Salt Attack, Mohamed Sakr, Mohamed T. Bassuoni
International Conference on Durability of Concrete Structures
Physical salt attack (PSA) is a key deterioration mechanism for concrete structures in contact with salt-rich media. Yet, procedures and techniques for protecting and repairing concrete affected by PSA are not adequately addressed in the technical literature. Therefore, in this study, three surface coatings of concrete were tested to determine their ability to withstand conditions stimulating to PSA. The treatments were selected to achieve either a single function such as acting as a membrane layer or hydrophobic agent, or combined pore blocking and water repelling functions. Coatings were applied on a concrete mixture typically used for residential foundations in Canada. …
Social Dimensions In Sustainability Evaluation Of Deteriorating Reinforced Concrete Bridges,
2019
Zhejiang University
Social Dimensions In Sustainability Evaluation Of Deteriorating Reinforced Concrete Bridges, Zhujun Wang, Weiliang Jin, Wu Kexian, Dan M. Frangopol
International Conference on Durability of Concrete Structures
Structural sustainability requires that structural engineering activities should find ways to design and maintain structures that perform as required during their life-cycle considering intergenerational needs. Massive attention has been paid to the economic and environmental evaluation of structures. However, being a completely different discipline from structural engineering, the social dimensions associated with structures were rarely considered in previous studies due to the difficulty in determination and quantification, unavoidable subjectivity and controversy, as well as the lack of historical data. This paper identifies the social impacts induced by engineering activities associated with the deterioration of reinforced concrete structures, and proposes corresponding …
