Assistive Utensil: A Spork For Hand Tremors And Spatial Awareness,
2018
City University of New York (CUNY)
Assistive Utensil: A Spork For Hand Tremors And Spatial Awareness, Ana Font Hernandez, Jacob Kabariti, Troy Taylor
Publications and Research
In this poster, we present a 3D printed solution for hand tremors and special awareness. Our spork is an assistive device designed and 3D printed for patients suffering from scleroderma, systemic sclerosis, Parkinson's, multiple sclerosis, drug withdrawal, etc. The scale-based handle will act as a counterweight to offset the contents on the other end and reduce shakiness. The larger grip allows an easy and comfortable hold. The product will be 3D printed for a customizable fit and at an affordable price. Lastly, the product will include a haptic feedback sensor to assist the visually impaired in locating food contents on …
In-Home Delivery Of Constraint-Induced Movement Therapy Via Virtual Reality Gaming,
2018
College of St. Scholastica
In-Home Delivery Of Constraint-Induced Movement Therapy Via Virtual Reality Gaming, Alexandra L. Borstad, Roger Crawfis, Kala Phillips, Linda Pax Lowes, David Maung, Ryan Mcpherson, Amelia Siles, Lise Worthen-Chaudhari, Lynne V. Gauthier
Journal of Patient-Centered Research and Reviews
Purpose: People with chronic hemiparesis are frequently dissatisfied with the recovery of their hand and arm, yet many lack access to effective treatments. Constraint-induced movement therapy (CI therapy) effectively increases arm function and spontaneous use in persons with chronic hemiparesis. The purpose of this study was to determine the feasibility and measure safety and outcomes of an in-home model of delivering CI therapy using a custom, avatar-based virtual reality game.
Methods: Seventeen individuals with chronic hemiparesis participated in this pretest/posttest quasi-experimental design study. The 10-day intervention had three components: 1) high-repetition motor practice using virtual reality gaming; 2) constraint of …
The Effectiveness Of Interventions And Bundles For Central Line-Associated Bloodstream Infections In The Neonatal Intensive Care Unit,
2018
University of Central Florida
The Effectiveness Of Interventions And Bundles For Central Line-Associated Bloodstream Infections In The Neonatal Intensive Care Unit, Mohamad Alhamwi
Honors Undergraduate Theses
Introduction: Central Line-Associated Bloodstream Infections (CLABSIs) are a major cause of increased mortality, morbidity and healthcare costs in neonatal intensive care units (NICUs) patients. Despite CDC's efforts to reduce infection rates, patients often suffer consequences. The objective of this study is to perform a systematic review of strategies utilized in the neonatal population and evaluate them with the current CDC's guidelines to assess the effectiveness of bundles in preventing CLABSI in NICUs.
Methods: A systematic literature search was conducted using CINAHL Plus with Text, Cochrane Database of Systematic Reviews and MEDLINE from January 2008 up to 2018. There were multiple …
Evaluation Of Individual And Combined Markers Of Urine Dipstick Parameters And Total Lymphocyte Count As A Substitute For Cd4 Count In Low-Resource Communities In Ghana,
2018
Edith Cowan University
Evaluation Of Individual And Combined Markers Of Urine Dipstick Parameters And Total Lymphocyte Count As A Substitute For Cd4 Count In Low-Resource Communities In Ghana, Enoch Odame Anto, Christian Obirikorang, Emmanuel Acheampong, Bright Amankwaa, Bright Oppong Afranie, Sampson Donkor, Isaac Hope, Juliana Jommo, Esther Osaah
Research outputs 2014 to 2021
We evaluated the individual and combined levels of urine dipstick and total lymphocyte count (TLC) as surrogate markers for CD4 count in a low-resource community in Ghana. This cross-sectional study recruited 200 HIV-infected patients from the Saint Francis Xavier Hospital, Assin Fosu, Ghana. Complete blood count, CD4 count, and urine dipstick analysis were measured for participants. The threshold values were determined as/
Components Of The X-Ray Circuit,
2018
Parkland College
Components Of The X-Ray Circuit, Savannah Burkhalter
A with Honors Projects
This video identifies the components of an x-ray circuit.
Device Therapies Among Patients Receiving Primary Prevention Implantable Cardioverter-Defibrillators In The Cardiovascular Research Network,
2018
Touro College
Device Therapies Among Patients Receiving Primary Prevention Implantable Cardioverter-Defibrillators In The Cardiovascular Research Network, Robert T. Greenlee, Alan S. Go, Pamela N. Peterson, Andrea E. Cassidy-Bushrow, Charles Gaber, Romel Garcia-Montilla, Alan H. Kadish
Office of the President Publications and Research
BACKGROUND: Primary prevention implantable cardioverter-defibrillators (ICDs) reduce mortality in selected patients with left ventricular systolic dysfunction by delivering therapies (antitachycardia pacing or shocks) to terminate potentially lethal arrhythmias; inappropriate therapies also occur. We assessed device therapies among adults receiving primary prevention ICDs in 7 healthcare systems.
METHODS AND RESULTS: We linked medical record data, adjudicated device therapies, and the National Cardiovascular Data Registry ICD Registry. Survival analysis evaluated therapy probability and predictors after ICD implant from 2006 to 2009, with attention to Centers for Medicare and Medicaid Services Coverage With Evidence Development subgroups: left ventricular ejection fraction, 31% to 35%; …
Assessment Of Falls On A Medical-Telemetry Unit,
2017
The University of San Francisco
Assessment Of Falls On A Medical-Telemetry Unit, Andie Reed
Master's Projects and Capstones
The purpose of this quality improvement project aimed at reducing falls on a medical-telemetry unit in a large metropolitan Magnet hospital. It was important for the MSN/CNL students to focus on falls because it is not just a concern for this institution, it is a national dilemma that needs to be addressed. Due to the complexities and intricate details of the IRB process, the MSN/CNL students were unable to collect data or further advance their project into the microsystem. Instead, information was attained from the University of San Francisco database to allow the MSN/CNL students to continue with the steps …
The Development Of A Wayfinding Smart Phone Application As A Large Healthcare Facility Investment Opportunity,
2017
University of Southern Mississippi
The Development Of A Wayfinding Smart Phone Application As A Large Healthcare Facility Investment Opportunity, Jessie Fortson Marshall
Doctoral Projects
Health care is a continually growing field. New hospitals are constantly being built, while older facilities are experiencing renovation and expansion. With this growth comes a set of difficulties for patients as they try to navigate through large, multi-building facilities. Most large facilities have multiple parking garages, numerous buildings, and medical towers with an unending number of floors. Patients are forced to rely on directional signage to find their destination that is often insufficient. Attempting to navigate through large facilities is often overwhelming for visitors leading to frustration and stress.
New technology has allowed a convenient solution to this problem …
Effects Of Revision Surgery On Grade Of Adverse Local Tissue Reaction Following Recall Of A Modular Hip Implant,
2017
Aurora Advanced Orthopedics
Effects Of Revision Surgery On Grade Of Adverse Local Tissue Reaction Following Recall Of A Modular Hip Implant, Joseph F. Davies, Danielle M. Greer, Susan Truchan
Journal of Patient-Centered Research and Reviews
Background: The Stryker Rejuvenate modular hip implant device allows for greater versatility in matching a patient’s anatomy than conventional implants. Device recalls and in vivo metal hypersensitivity after total hip arthroplasty (THA) are common. However, recall of the Rejuvenate implant represents one of the largest recall volumes to date, highlighting our uncertainty regarding causes of device metal fretting/corrosion and adverse local tissue reaction (ALTR). While devices with metal-on-metal bearings historically were culprits for release of metal debris, more recently developed modular-neck devices add opportunity for adjacent metal components to rub together. With the Rejuvenate device, corrosion or fretting likely occurs …
Asia: Is High-End Innovation In Medical Technology A Blessing Or A Curse?,
2017
Singapore Management University
Asia: Is High-End Innovation In Medical Technology A Blessing Or A Curse?, Elisabeth Staudinger
Asian Management Insights
Is high-end innovation in medical technology a blessing or a curse?
A Preliminary Study Of A Spanish Graphic Novella Targeting Hearing Loss Prevention,
2017
University of Wyoming
A Preliminary Study Of A Spanish Graphic Novella Targeting Hearing Loss Prevention, Mark Guiberson, Emily Wakefield
Department of Special Education and Communication Disorders: Faculty Publications
Purpose: This preliminary study developed a digital graphic novella targeting hearing protection beliefs of Spanish-speaking agricultural workers. Researchers used pretest–posttest interview surveys to establish if the novella had an immediate influence on the participants’ beliefs about noise-induced hearing loss and usage of hearing protection devices.
Method: Researchers developed a digital graphic novella directed to increase knowledge about noise-induced hearing loss and increase the proper use of hearing protection devices. The novella was tailored to meet the specific linguistic and literacy needs of Spanish-speaking agricultural workers. Thirty-one Spanish-speaking farmworkers of Mexican nationality participated. This study included an interview survey with specific …
Higher Medication Administration Errors Associated With Automated Dispensing System Usage,
2017
DePaul University
Higher Medication Administration Errors Associated With Automated Dispensing System Usage, Jillian Cramer
Grace Peterson Nursing Research Colloquium
According to a report by The Institute of Medicine, medical errors were associated with up to 98,000 deaths and more than 1 million injuries each year in the United States. These errors can result in poor outcomes, which increase harm or death. According to the Pennsylvania Patient Safety Reporting System, up to 15% of errors reported cite automated dispensing cabinets as the source of the drug involved in the error.Nearly 58% to 70% of hospitals nationwide use automated dispensing cabinets. Nurses play a critical role in promoting patient safety by surveilling and intercepting any possible errors that could occur during …
The Motor Cortical Representation Of A Muscle Is Not Homogeneous In Brain Connectivity,
2017
Chapman University
The Motor Cortical Representation Of A Muscle Is Not Homogeneous In Brain Connectivity, Jo Armour Smith, Alaa Albishi, Sarine Babikian, Skulpan Asavasopon, Beth E. Fisher, Jason Kutch
Physical Therapy Faculty Articles and Research
Functional connectivity patterns of the motor cortical representational area of single muscles have not been extensively mapped in humans, particularly for the axial musculature. Functional connectivity may provide a neural substrate for adaptation of muscle activity in axial muscles that have both voluntary and postural functions. The purpose of this study was to combine brain stimulation and neuroimaging to both map the cortical representation of the external oblique (EO) in primary motor cortex (M1) and supplementary motor area (SMA), and to establish the resting-state functional connectivity associated with this representation. Motor evoked potentials were elicited from the EO muscle in …
Design, Validation, And Clinical Testing Of A Novel Fastening Device For A Scoliosis Brace,
2017
University of Tennessee Health Science Center
Design, Validation, And Clinical Testing Of A Novel Fastening Device For A Scoliosis Brace, Cody Keith Bateman
Theses and Dissertations (ETD)
Each year, thirty thousand children in the US were put into a scoliosis brace. The primary function of scoliosis braces was to reduce and prevent progression of the spinal deformity as the patient grew by application of corrective forces to the spine. Straps, often made of Velcro, were attached to the back of the brace that applied forces to the spine when the straps were tightened. Braces were prescribed to be worn up to 23 hours a day. Studies have concluded that discomfort increased with increasing strap tension and pad pressure. They have also shown an increase in strap tension …
Needs Assessment Of Pediatric Radiological Equipment And Cross-Cultural Investigation Into Parental Empowerment In Pediatric Radiology Program Development In The Kingdom Of Bhutan,
2017
George Washington University
Needs Assessment Of Pediatric Radiological Equipment And Cross-Cultural Investigation Into Parental Empowerment In Pediatric Radiology Program Development In The Kingdom Of Bhutan, Danielle Canter
GW Research Days 2016 - 2020
Background:
Bhutan is a magnificent mountainous country hugged by India to the east and west and by China to the North and South. This peaceful nestled country faces challenges in combating non-communicable diseases due to the lack of radiological equipment necessary for early diagnosis. Prior to implementation of these medical devices, it is imperative to investigate the cultural attitudes, beliefs, and infrastructure, to ensure successful integration. Bhutan is beginning to implement a pediatric radiology program for the nation with the assistance of ABAH Foundation and RAD-AID International, both of whom partnered with graduate students at George Washington University School of …
A Novel Hybrid Imaging System To Aid In Surgical Decision Making,
2017
Western University
A Novel Hybrid Imaging System To Aid In Surgical Decision Making, Lawrence Yip, Madeleine Van De Kleut, Ivan Kosik, Astrid Chamson-Reig, Jeffrey Jl Carson
Western Research Forum
Background:
Breast cancer accounts for 25% of all cancer cases among women. In breast-conserving surgery, a common treatment, the tumour is excised with a healthy tissue margin. However, detection of the margin can be difficult. Current techniques to guide excision are often insufficient, and re-excision can occur up to 25% of the time.
Methods:
Photoacoustic imaging is a hybrid imaging modality that combines the advantages of optical imaging and ultrasound while using safe non-ionizing light. This project involves the development of a novel imaging system with a new scanner design to overcome common limitations and provide images to aid in …
Validity And Reliability Of The Balance Tracking System™ During Static Stance,
2017
Georgia Southern University
Validity And Reliability Of The Balance Tracking System™ During Static Stance, Cody L. Grotewold
College of Graduate Studies: Theses & Dissertations
Introduction: The Balance Tracking System™ (BTrackS™) is a balance board designed to quickly analyze postural control through center of pressure (COP) analysis.
Purpose: Examine concurrent validity and test-retest reliability of the BTrackS™ during static stance.
Methods: A convenience sample of 51 healthy collegiate students between 18 - 25 years old (21.8 ± 3.1 years) completed four, 20 second (s) trials of feet together static stance during both eyes open and closed trials. Data was simultaneously collected on the BTrackS™ and a laboratory force plate to establish concurrent validity. A second testing session was administered 48 - 72 …
Comparison Of Inappropriate Shocks And Other Health Outcomes Between Single- And Dual-Chamber Implantable Cardioverter-Defibrillators For Primary Prevention Of Sudden Cardiac Death: Results From The Cardiovascular Research Network Longitudinal Study Of Implantable Cardioverter-Defibrillators, Pamela N. Peterson, Robert T. Greenlee, Alan S. Go, David J. Magid, Andrea Cassidy-Bushrow, Romel Garcia-Montilla, Alan H. Kadish
Office of the President Publications and Research
Background In US clinical practice, many patients who undergo placement of an implantable cardioverter‐defibrillator (ICD) for primary prevention of sudden cardiac death receive dual‐chamber devices. The superiority of dual‐chamber over single‐chamber devices in reducing the risk of inappropriate ICD shocks in clinical practice has not been established. The objective of this study was to compare risk of adverse outcomes, including inappropriate shocks, between single‐ and dual‐chamber ICDs for primary prevention.
Methods and Results We identified patients receiving a single‐ or dual‐chamber ICD for primary prevention who did not have an indication for pacing from 15 hospitals within 7 integrated health …
Pediatric Emergency Medicine Point-Of-Care Ultrasound: Summary Of The Evidence.,
2016
George Washington University
Pediatric Emergency Medicine Point-Of-Care Ultrasound: Summary Of The Evidence., Jennifer R Marin, Alyssa M. Abo, Alexander C Arroyo, Stephanie J Doniger, Jason W Fischer, Rachel Rempell, +21 Additional Authors
Pediatrics Faculty Publications
The utility of point-of-care ultrasound is well supported by the medical literature. Consequently, pediatric emergency medicine providers have embraced this technology in everyday practice. Recently, the American Academy of Pediatrics published a policy statement endorsing the use of point-of-care ultrasound by pediatric emergency medicine providers. To date, there is no standard guideline for the practice of point-of-care ultrasound for this specialty. This document serves as an initial step in the detailed "how to" and description of individual point-of-care ultrasound examinations. Pediatric emergency medicine providers should refer to this paper as reference for published research, objectives for learners, and standardized reporting …
Letter To The Editor Regarding “Clinical Effectiveness And Safety Of Powered Exoskeleton-Assisted Walking In Patients With Spinal Cord Injury: Systematic Review With Meta-Analysis”,
2016
Wayne State University
Letter To The Editor Regarding “Clinical Effectiveness And Safety Of Powered Exoskeleton-Assisted Walking In Patients With Spinal Cord Injury: Systematic Review With Meta-Analysis”, Marcel P. Dijkers, Katherine G. Akers, Sujay S. Galen, Diane E. Patzer, Phuong T. Vu
Library Scholarly Publications
No abstract provided.
